Changes for page Mitsubishi
Last modified by Joe on 2024/05/21 10:53
From version 56.1
edited by Theodore Xu
on 2023/09/15 11:12
on 2023/09/15 11:12
Change comment:
There is no comment for this version
To version 48.1
edited by Theodore Xu
on 2023/09/15 10:40
on 2023/09/15 10:40
Change comment:
There is no comment for this version
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 0 added, 4 removed)
Details
- Page properties
-
- Content
-
... ... @@ -1,3 +1,49 @@ 1 +== **FX1S,1N,2N Serial ** == 2 + 3 +Supported Series: Mitsubishi FX1S, FX1N, FX2N series 4 + 5 +**V-BOX Settings** 6 + 7 +|**Item**|**Settings**|**Note** 8 +|Protocol|Mitsubishi FX1S/FX1N/FX2N| 9 +|Connection|RS422/RS485/RS232| 10 +|Baud rate|9600~~115200| 11 +|Data bit|7/8| 12 +|Parity|EVEN/Odd/None| 13 +|Stop bit|1/2| 14 +|PLC station No.|1~~255| 15 + 16 +**Address List** 17 + 18 +|**Type**|**Device registers**|**V-Box registers**|**Format**|**Range**|**Note** 19 +|(% rowspan="7" %)Bit|X|X|Xo|0~~303237| 20 +|Y|Y|Y o|0~~303237| 21 +|M|M|M d|0~~99999| 22 +|T|T|T d|0~~99999| 23 +|C|C|C d|0~~99999| 24 +|S|S|S d|0~~99999| 25 +|SM|SM|SM d|8000~~9999| 26 +|(% rowspan="8" %)Word|X|X|Xo|0~~303237| 27 +|Y|Y|Y o|0~~303237| 28 +|M|M|M d|0~~99999| 29 +|T|T|T d|0~~99999| 30 +|C|C|C d|0~~199| 31 +|D|D|D d|0~~7999| 32 +|S|S|S d|0~~99999| 33 +|SD|SD|SD d|8000~~9999| 34 + 35 +**Configure the communication protocol** 36 + 37 +{{id name="Iimage-20220825102844-3.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_dc262f14b14cf564.png||alt="image-20220825102844-3.png" height="1011" width="1920"]] 38 + 39 +**Cable Wiring** 40 + 41 +**RS422** 42 + 43 +[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_9294a40c62eb99be.png||alt="image-20220825103350-4.png" height="284" width="723"]] 44 + 45 +[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_860bcf87f6ca7b98.png||alt="image-20220825100845-4.png" height="246" width="419"]] 46 + 1 1 == **FX3U,3G,3GA Serial ** == 2 2 3 3 Supported Series: Mitsubishi FX3U, FX3G, FX3GA series ... ... @@ -220,9 +220,6 @@ 220 220 |Stop bit|1| 221 221 |PLC station No.|1~~255|Need to be the same as PLC settings 222 222 223 -(% style="text-align:center" %) 224 -[[image:三菱 FX5U 串口协议配置.png]] 225 - 226 226 **Address List** 227 227 228 228 |**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note** ... ... @@ -277,6 +277,10 @@ 277 277 278 278 Done. 279 279 323 +**Configure the communication protocol** 324 + 325 +{{id name="Iimage-20220825104904-1.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_dbaddd53e9951a17.png||alt="image-20220825104904-1.png" height="1033" width="1920"]] 326 + 280 280 **Cable Wiring** 281 281 282 282 **RS422** ... ... @@ -376,9 +376,6 @@ 376 376 |Stop bit|1| 377 377 |PLC station No.|1~~255|Need to be the same as PLC settings 378 378 379 -(% style="text-align:center" %) 380 -[[image:三菱 L02串口协议配置.png]] 381 - 382 382 **Address List** 383 383 384 384 |**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note** ... ... @@ -414,6 +414,10 @@ 414 414 |ZR|ZR|ZR h|0~~FFFF| 415 415 |D|D|D d|0~~99999| 416 416 461 +**Communication Settings** 462 + 463 +[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_cfed67f2ecb4ccec.png||alt="image-20220825160648-3.png" height="1009" width="1920"]] 464 + 417 417 **Cable Wiring** 418 418 419 419 **RS422** ... ... @@ -434,8 +434,6 @@ 434 434 |Port No.|1025|Must be the same as the PLC setting 435 435 |PLC station No.|0|Must be the same as the PLC setting 436 436 437 -(% style="text-align:center" %) 438 -[[image:三菱 L02以太网协议配置1.png]] 439 439 440 440 **PLC Settings (GX Works2 )** 441 441 ... ... @@ -445,11 +445,11 @@ 445 445 446 446 Select [Binary Code] as communication data code; 447 447 448 -[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_776e17505f3fc6c0.png?width=600&height=524&rev=1.1||alt="12.PLC Protocol_html_776e17505f3fc6c0.png" height="524" width="600"]] 494 +{{id name="Ihttps:2F2Fdocs.we-con.com.cn2Fbin2Fdownload2FPIStudio2F12.PLC2520protocols2FWebHome2F12.PLC2520Protocol_html_776e17505f3fc6c0.png3Fwidth3D60026height3D52426rev3D1.1"/}}[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_776e17505f3fc6c0.png?width=600&height=524&rev=1.1||alt="12.PLC Protocol_html_776e17505f3fc6c0.png" height="524" width="600"]] 449 449 450 450 Set PLC port number, for example 1025 451 451 452 -[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_8d0d1a22d388f70b.png?width=600&height=524&rev=1.1||alt="12.PLC Protocol_html_8d0d1a22d388f70b.png" height="524" width="600"]] 498 +{{id name="Ihttps:2F2Fdocs.we-con.com.cn2Fbin2Fdownload2FPIStudio2F12.PLC2520protocols2FWebHome2F12.PLC2520Protocol_html_8d0d1a22d388f70b.png3Fwidth3D60026height3D52426rev3D1.1"/}}[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_8d0d1a22d388f70b.png?width=600&height=524&rev=1.1||alt="12.PLC Protocol_html_8d0d1a22d388f70b.png" height="524" width="600"]] 453 453 454 454 Save settings; 455 455 ... ... @@ -457,10 +457,14 @@ 457 457 458 458 Restart PLC device; 459 459 460 -**C ableWiring**506 +**4)Configure the communication protocol** 461 461 462 -[[image: https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_2297240b57346b2a.png?width=401&height=170&rev=1.1||alt="12.PLC Protocol_html_2297240b57346b2a.png" height="170" width="401"]]508 +{{id name="Iimage-20220825142659-1.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_fafc9b29e20178c0.png||alt="image-20220825142659-1.png" height="1010" width="1920"]] 463 463 510 +**5)Cable Wiring** 511 + 512 +{{id name="Ihttps:2F2Fdocs.we-con.com.cn2Fbin2Fdownload2FPIStudio2F12.PLC2520protocols2FWebHome2F12.PLC2520Protocol_html_2297240b57346b2a.png3Fwidth3D40126height3D17026rev3D1.1-1"/}}[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_2297240b57346b2a.png?width=401&height=170&rev=1.1||alt="12.PLC Protocol_html_2297240b57346b2a.png" height="170" width="401"]] 513 + 464 464 == {{id name="HQ12HSerial"/}}**Q12H Serial ** == 465 465 466 466 This Demo shows V-BOX communicate with Q12H PLC by Q02H serial Protocol ... ... @@ -471,7 +471,7 @@ 471 471 472 472 Mitsubishi QJ71E71 Ethernet communication module; 473 473 474 -**V-BOX Settings** 524 +**1)V-BOX Settings** 475 475 476 476 |**Items**|**Settings**|**Note** 477 477 |Protocol|MIT QJ71E71 MELSEC| ... ... @@ -479,10 +479,8 @@ 479 479 |Port No.|1025|Must be the same as the PLC setting 480 480 |PLC station No.|0|Must be the same as the PLC setting 481 481 482 - [[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_50990385ef491b9e.png||alt="image-20221119171832-5.png"height="354" width="625"]]532 +**2)Address List** 483 483 484 -**Address List** 485 - 486 486 |**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note** 487 487 |(% rowspan="18" %)Bit|X|X|X h|0~~1FFF| 488 488 |Y|Y|Y h|0~~1FFF| ... ... @@ -513,16 +513,16 @@ 513 513 |Z|Z|Z d|0~~15| 514 514 |ZR|ZR|ZR h|0~~FE7FF| 515 515 516 -**PLC Settings(GX Works2)** 564 +**3)PLC Settings(GX Works2)** 517 517 518 518 * Click [Ethernet/CC IE/MELSECNET]; 519 519 * Please select [Ethernet] as network type; 520 520 * Set station I/O number according to situation (For example, 0020 means that the module is connected to PLC CPU in first order); 521 521 * Select [Online] as Mode; 522 -* [[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_d54f23688c520f78.png||alt="image-20221119171343-2.png" height="341" width="587"]] 570 +* {{id name="Iimage-20221119171343-2.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_d54f23688c520f78.png||alt="image-20221119171343-2.png" height="341" width="587"]] 523 523 * Click [Operation setting] to set IP; 524 524 * Select [Binary Code] as [Communication Data Code]; 525 -* [[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_ce8e6a671b9508e0.png||alt="image-20221119171436-3.png" height="354" width="588"]] 573 +* {{id name="Iimage-20221119171436-3.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_ce8e6a671b9508e0.png||alt="image-20221119171436-3.png" height="354" width="588"]] 526 526 * Click [Open setting] 527 527 * Set protocol: TCP; 528 528 * Set [unpassive] in [Open system]; ... ... @@ -535,6 +535,10 @@ 535 535 * {{id name="Iimage-20221119171611-4.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_1d8e2f4fb7c72471.png||alt="image-20221119171611-4.png" height="354" width="588"]] 536 536 * Download project into PLC and restart it 537 537 538 -**C ableWiring**586 +**4)Configure the communication protocol** 539 539 588 +{{id name="Iimage-20221119171832-5.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_50990385ef491b9e.png||alt="image-20221119171832-5.png" height="354" width="625"]] 589 + 590 +**5)Cable Wiring** 591 + 540 540 [[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_2297240b57346b2a.png?width=401&height=170&rev=1.1||alt="12.可编程逻辑控制器Protocol_html_2297240b57346b2a.png" height="170" width="401"]]
- 三菱 FX5U 串口协议配置.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.AiXia - Size
-
... ... @@ -1,1 +1,0 @@ 1 -65.0 KB - Content
- 三菱 L02 以太网盒子通讯配置.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.AiXia - Size
-
... ... @@ -1,1 +1,0 @@ 1 -66.5 KB - Content
- 三菱 L02串口协议配置.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.AiXia - Size
-
... ... @@ -1,1 +1,0 @@ 1 -64.4 KB - Content
- 三菱 L02以太网协议配置1.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.AiXia - Size
-
... ... @@ -1,1 +1,0 @@ 1 -66.7 KB - Content