Changes for page Mitsubishi
Last modified by Joe on 2024/05/21 10:53
From version 56.1
edited by Theodore Xu
on 2023/09/15 11:12
on 2023/09/15 11:12
Change comment:
There is no comment for this version
To version 59.1
edited by Theodore Xu
on 2023/09/15 11:25
on 2023/09/15 11:25
Change comment:
There is no comment for this version
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 2 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -13,6 +13,9 @@ 13 13 |Stop bit|1/2| 14 14 |PLC station No.|1~~255| 15 15 16 +(% style="text-align:center" %) 17 +[[image:三菱 FX3U 串口协议配置.png]] 18 + 16 16 **Address List** 17 17 18 18 |**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note** ... ... @@ -32,10 +32,6 @@ 32 32 |S|S|S d|0~~99999| 33 33 |SD|SD|SD d|8000~~9999| 34 34 35 -**Configure the communication protocol** 36 - 37 -[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_4d2a4921240d23c6.png||alt="image-20220825102649-2.png" height="1009" width="1920"]] 38 - 39 39 **PLC Setting** 40 40 41 41 Open GX Works2, create a new PLC project or open the project that has been created. ... ... @@ -122,6 +122,8 @@ 122 122 |Port No.|5009|Must be the same as the PLC setting 123 123 |PLC station No.|0| 124 124 124 +[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_b2cdc33b6eb92b67.png||alt="image-20221119101946-2.png" height="395" width="695"]] 125 + 125 125 **Address List** 126 126 127 127 |**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note** ... ... @@ -201,10 +201,6 @@ 201 201 202 202 [[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_7f29923ebcb670d1.png||alt="image-20221116111727-5.png" height="416" width="697"]] 203 203 204 -**Configure the communication protocol** 205 - 206 -[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_b2cdc33b6eb92b67.png||alt="image-20221119101946-2.png" height="395" width="695"]] 207 - 208 208 == **FX5U Serial ** == 209 209 210 210 Mitsubishi FX5U series PLC ... ... @@ -289,7 +289,7 @@ 289 289 290 290 Mitsubishi FX5U series PLC 291 291 292 -** 1)V-BOX Settings**289 +**V-BOX Settings** 293 293 294 294 |**Items**|**Settings**|**Note** 295 295 |Protocol|Mitsubishi FX5U| ... ... @@ -297,8 +297,11 @@ 297 297 |Port No.|5002|Must be the same as the PLC setting 298 298 |PLC station No.|0| 299 299 300 -**2)Address List** 297 +(% style="text-align:center" %) 298 +[[image:三菱 FX5U 以太网协议配置.png]] 301 301 300 +**Address List** 301 + 302 302 |**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note** 303 303 |(% rowspan="15" %)Bit|X|X|X o|0~~303237| 304 304 |Y|Y|Y o|0~~303237| ... ... @@ -325,11 +325,11 @@ 325 325 |D|D|D d|0~~7999| 326 326 |SD|SD|SD d|0~~11999| 327 327 328 -** 3)PLC Settings (GX Works 3)**328 +**PLC Settings (GX Works 3)** 329 329 330 330 Find the [Ethernet port] in the navigation area. 331 331 332 - {{id name="Ihttps:2F2Fdocs.we-con.com.cn2Fbin2Fdownload2FPIStudio2F12.PLC2520protocols2FWebHome2F12.PLC2520Protocol_html_8e8f85ace087346c.png3Fwidth3D30026height3D59326rev3D1.1"/}}[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_8e8f85ace087346c.png?width=300&height=593&rev=1.1||alt="12.PLC Protocol_html_8e8f85ace087346c.png" height="593" width="300"]]332 +[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_8e8f85ace087346c.png?width=300&height=593&rev=1.1||alt="12.PLC Protocol_html_8e8f85ace087346c.png" height="593" width="300"]] 333 333 334 334 Select [Own Node Settings] in the [Setting Item List]; 335 335 ... ... @@ -337,7 +337,7 @@ 337 337 338 338 Click [Detailed Settings] into [Ethernet Configuration (Built-in Ethernet Port)] windows; 339 339 340 - {{id name="Ihttps:2F2Fdocs.we-con.com.cn2Fbin2Fdownload2FPIStudio2F12.PLC2520protocols2FWebHome2F12.PLC2520Protocol_html_5d98495052c8c10e.png3Fwidth3D60026height3D33926rev3D1.1"/}}[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_5d98495052c8c10e.png?width=600&height=339&rev=1.1||alt="12.PLC Protocol_html_5d98495052c8c10e.png" height="339" width="600"]]340 +[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_5d98495052c8c10e.png?width=600&height=339&rev=1.1||alt="12.PLC Protocol_html_5d98495052c8c10e.png" height="339" width="600"]] 341 341 342 342 Select [SLMP Connection Module] and add into host station as below picture shows; 343 343 ... ... @@ -345,20 +345,17 @@ 345 345 346 346 Click [Close with Reflecting the Setting] to save and close window; 347 347 348 - {{id name="Ihttps:2F2Fdocs.we-con.com.cn2Fbin2Fdownload2FPIStudio2F12.PLC2520protocols2FWebHome2F12.PLC2520Protocol_html_14b489fdc6c6589d.png3Fwidth3D60026height3D35026rev3D1.1"/}}[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_14b489fdc6c6589d.png?width=600&height=350&rev=1.1||alt="12.PLC Protocol_html_14b489fdc6c6589d.png" height="350" width="600"]]348 +[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_14b489fdc6c6589d.png?width=600&height=350&rev=1.1||alt="12.PLC Protocol_html_14b489fdc6c6589d.png" height="350" width="600"]] 349 349 350 350 Click [Apply] to completed Etherenet settings; 351 351 352 352 Switch to the [On line data operation] interface as below, check the item and click [Execute] to download. 353 353 354 - {{id name="Ihttps:2F2Fdocs.we-con.com.cn2Fbin2Fdownload2FPIStudio2F12.PLC2520protocols2FWebHome2F12.PLC2520Protocol_html_c93025a968a8a9e7.png3Fwidth3D60026height3D43426rev3D1.1"/}}[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_c93025a968a8a9e7.png?width=600&height=434&rev=1.1||alt="12.PLC Protocol_html_c93025a968a8a9e7.png" height="434" width="600"]]354 +[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_c93025a968a8a9e7.png?width=600&height=434&rev=1.1||alt="12.PLC Protocol_html_c93025a968a8a9e7.png" height="434" width="600"]] 355 355 356 -**4)Configure the communication protocol** 357 357 358 - {{id name="Iimage-20220825112403-1.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_caa9bf4d8cc6de0f.png||alt="图片-20220825112403-1.png" height="1033"width="1920"]]357 +**Cable Wiring** 359 359 360 -**5)Cable Wiring** 361 - 362 362 [[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_2297240b57346b2a.png?width=401&height=170&rev=1.1||alt="12.可编程逻辑控制器Protocol_html_2297240b57346b2a.png" height="170" width="401"]] 363 363 364 364 == **L02 Serial ** ==
- 三菱 FX3U 串口协议配置.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.AiXia - Size
-
... ... @@ -1,0 +1,1 @@ 1 +65.5 KB - Content
- 三菱 FX5U 以太网协议配置.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.AiXia - Size
-
... ... @@ -1,0 +1,1 @@ 1 +64.2 KB - Content