Changes for page Mitsubishi

Last modified by Joe on 2024/05/21 10:53

From version 57.1
edited by Theodore Xu
on 2023/09/15 11:13
Change comment: There is no comment for this version
To version 39.1
edited by Theodore Xu
on 2023/09/15 09:38
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -1,11 +1,11 @@
1 -== **FX3U,3G,3GA Serial ** ==
1 +== **FX1S,1N,2N Serial ** ==
2 2  
3 -Supported Series: Mitsubishi FX3U, FX3G, FX3GA series
3 +Supported Series: Mitsubishi FX1S, FX1N, FX2N series
4 4  
5 5  **V-BOX Settings**
6 6  
7 7  |**Item**|**Settings**|**Note**
8 -|Protocol|Mitsubishi FX3U/3G/3GA|
8 +|Protocol|Mitsubishi FX1S/FX1N/FX2N|
9 9  |Connection|RS422/RS485/RS232|
10 10  |Baud rate|9600~~115200|
11 11  |Data bit|7/8|
... ... @@ -15,7 +15,7 @@
15 15  
16 16  **Address List**
17 17  
18 -|**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note**
18 +|**Type**|**Device registers**|**V-Box registers**|**Format**|**Range**|**Note**
19 19  |(% rowspan="7" %)Bit|X|X|Xo|0~~303237|
20 20  |Y|Y|Y o|0~~303237|
21 21  |M|M|M d|0~~99999|
... ... @@ -34,62 +34,35 @@
34 34  
35 35  **Configure the communication protocol**
36 36  
37 -[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_4d2a4921240d23c6.png||alt="image-20220825102649-2.png" height="1009" width="1920"]]
37 +{{id name="Iimage-20220825102844-3.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_dc262f14b14cf564.png||alt="image-20220825102844-3.png" height="1011" width="1920"]]
38 38  
39 -**PLC Setting**
40 -
41 -Open GX Works2, create a new PLC project or open the project that has been created.
42 -Create new project: [Project]→[New]→[Series] FXCPU→[Type] FX3G/FX3GC→[OK].
43 -
44 -(% style="text-align:center" %)
45 -[[image:1.2.png]]
46 -
47 -PLC Default Parameters:
48 -[Connection type]RS422;[Baud rate]9600, [Data bit]7, [Stop bit]1,[Parity]EVEN; [Station number]0
49 -Note:The serial port parameters should be set depending on field requirements
50 -
51 -PC and PLC connection:
52 -
53 -[All connection]→[Connection 1]→[Transfer Setup Connection1]→[Serial USB]→RS-232C: PC and PLC are connected by USB to RS232 adapter,choose corresponding [COM Port]COM 5 →[Transmission speed]9.6Kbps→[setup] →[Parity]EVEN→[Data bits]7→[Stop bits]1→[OK]
54 -
55 -(% style="text-align:center" %)
56 -[[image:1.5.1.png]]
57 -
58 -Connection test:when connection is OK,the GX Works2 prompts “Successfully connected with the FX3G/FX3GCCPU.”
59 -
60 -(% style="text-align:center" %)
61 -[[image:1.5.2.png]]
62 -
63 63  **Cable Wiring**
64 64  
65 65  **RS422**
66 66  
67 -[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_1e904556bb758dfe.png||alt="image-20220825103421-5.png" height="296" width="715"]]
43 +[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_9294a40c62eb99be.png||alt="image-20220825103350-4.png" height="284" width="723"]]
68 68  
69 69  [[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_860bcf87f6ca7b98.png||alt="image-20220825100845-4.png" height="246" width="419"]]
70 70  
71 -== **FX NOPROTOCOL** ==
47 +== **FX3U,3G,3GA Serial ** ==
72 72  
73 -Mitsubishi FX3G-RS232-BD
49 +Supported Series: Mitsubishi FX3U, FX3G, FX3GA series
74 74  
75 -**V-Box Settings**
51 +**V-BOX Settings**
76 76  
77 -|=**Item**|=**Settings**|=**Note**
78 -|Protocol|Mitsubishi FX NOPROTOCOL|
79 -|Connection|RS232|
80 -|Baud rate|9600|
81 -|Data bit|7|
82 -|Parity|EVEN|
83 -|Stop bit|1|
84 -|PLC station No.|0|
53 +|**Item**|**Settings**|**Note**
54 +|Protocol|Mitsubishi FX3U/3G/3GA|
55 +|Connection|RS422/RS485/RS232|
56 +|Baud rate|9600~~115200|
57 +|Data bit|7/8|
58 +|Parity|EVEN/Odd/None|
59 +|Stop bit|1/2|
60 +|PLC station No.|1~~255|
85 85  
86 -(% style="text-align:center" %)
87 -[[image:三菱 FN盒子通讯配置.png]]
88 -
89 89  **Address List**
90 90  
91 -|=**Type**|=**Device registers**|=**HMI registers**|=**Format**|=**Range**|=**Note**
92 -|(% rowspan="8" %)Bit|X|X|X o|0~~303237|
64 +|**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note**
65 +|(% rowspan="7" %)Bit|X|X|Xo|0~~303237|
93 93  |Y|Y|Y o|0~~303237|
94 94  |M|M|M d|0~~99999|
95 95  |T|T|T d|0~~99999|
... ... @@ -96,8 +96,7 @@
96 96  |C|C|C d|0~~99999|
97 97  |S|S|S d|0~~99999|
98 98  |SM|SM|SM d|8000~~9999|
99 -|Lamp|Lamp|Lamp d|0~~0|
100 -|(% rowspan="8" %)Word|X|X|X o|0~~303237|
72 +|(% rowspan="8" %)Word|X|X|Xo|0~~303237|
101 101  |Y|Y|Y o|0~~303237|
102 102  |M|M|M d|0~~99999|
103 103  |T|T|T d|0~~99999|
... ... @@ -106,15 +106,23 @@
106 106  |S|S|S d|0~~99999|
107 107  |SD|SD|SD d|8000~~9999|
108 108  
109 -**Cable Wiring**
81 +**Configure the communication protocol**
110 110  
111 -[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_1717efe8d969a43c.png]]
83 +[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_4d2a4921240d23c6.png||alt="image-20220825102649-2.png" height="1009" width="1920"]]
112 112  
113 -== **FX3U Ethernet ** ==
85 +**4)Cable Wiring**
114 114  
87 +**RS422**
88 +
89 +[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_1e904556bb758dfe.png||alt="image-20220825103421-5.png" height="296" width="715"]]
90 +
91 +[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_860bcf87f6ca7b98.png||alt="image-20220825100845-4.png" height="246" width="419"]]
92 +
93 +== {{id name="HFX3UEthernet"/}}**FX3U Ethernet ** ==
94 +
115 115  Supported Modules: FX3U-ENET-ADP, FX3U-ENET-L
116 116  
117 -**V-BOX Settings**
97 +**1)V-BOX Settings**
118 118  
119 119  |Items|Settings|Note
120 120  |Protocol|Mitsubishi FX3U|
... ... @@ -122,10 +122,8 @@
122 122  |Port No.|5009|Must be the same as the PLC setting
123 123  |PLC station No.|0|
124 124  
125 -[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_b2cdc33b6eb92b67.png||alt="image-20221119101946-2.png" height="395" width="695"]]
105 +**2)Address List**
126 126  
127 -**Address List**
128 -
129 129  |**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note**
130 130  |(% rowspan="7" %)Bit|X|X|X OOO|0~~377|
131 131  |Y|Y|Y OOO|0~~377|
... ... @@ -140,19 +140,19 @@
140 140  |SD|SD|SD DDDD|8000~~8511|
141 141  |R|R|R DDDDD|0~~32767|
142 142  
143 -**Ethernet Module Settings**
121 +**3)Ethernet Module Settings**
144 144  
145 145  FX3U-ENET-L module configuration
146 146   Set up the FX3U-ENET-L Ethernet module settings as follows.
147 147   Select the module location, which in this document is Module 0.
148 148  
149 -[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_949d5d77c1d9cf1e.png||alt="image-20221116105850-1.png" height="573" width="706"]]
127 +{{id name="Iimage-20221116105850-1.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_949d5d77c1d9cf1e.png||alt="image-20221116105850-1.png" height="573" width="706"]]
150 150  
151 151  Select "Operational setting" to enter the following screen.
152 152  
153 153  The Ethernet module IP is set to 192.168.39.254 in this document, and other options are default.
154 154  
155 -[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_dfbfdd586c855c47.png||alt="image-20221116105947-1.png" height="573" width="706"]]
133 +{{id name="Iimage-20221116105947-1.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_dfbfdd586c855c47.png||alt="image-20221116105947-1.png" height="573" width="706"]]
156 156  
157 157  Select "Open setting" to enter the setting interface, the settings are as follows.
158 158  
... ... @@ -160,7 +160,7 @@
160 160  
161 161  Mitsubishi programming software GX works2 to communicate with the FX3U via the Ethernet module.
162 162  
163 -[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_7c01ac15090fcc5b.png||alt="image-20221116110802-1.png" height="549" width="706"]]
141 +{{id name="Iimage-20221116110802-1.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_7c01ac15090fcc5b.png||alt="image-20221116110802-1.png" height="549" width="706"]]
164 164  
165 165  Click on "transter setup" - "PC side I/F setting", see the following figure.
166 166  
... ... @@ -168,46 +168,50 @@
168 168  
169 169  use the IP set in the "Ethernet board" to communicate directly with the network cable.
170 170  
171 -[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_d6fd9ce3b96f99e2.png||alt="image-20221116110832-2.png" height="423" width="708"]]
149 +{{id name="Iimage-20221116110832-2.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_d6fd9ce3b96f99e2.png||alt="image-20221116110832-2.png" height="423" width="708"]]
172 172  
173 173  Read and write data from the Ethernet module
174 174  
175 -[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_690b3e57b29cfd4b.png||alt="image-20221116110907-3.png" height="549" width="706"]]
153 +{{id name="Iimage-20221116110907-3.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_690b3e57b29cfd4b.png||alt="image-20221116110907-3.png" height="549" width="706"]]
176 176  
177 177  Set "Transter setup" to COM communication, and read or write operation as shown below
178 178  
179 -[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_b317253742f7151.png||alt="image-20221116110917-4.png" height="549" width="706"]]
157 +{{id name="Iimage-20221116110917-4.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_b317253742f7151.png||alt="image-20221116110917-4.png" height="549" width="706"]]
180 180  
181 -**PLC Settings (GX Works 2)**
159 +**4)PLC Settings (GX Works 2)**
182 182  
183 183  Create a blank FX5U project
184 184  
185 185  Find Current Connection in the navigation
186 186  
187 -[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_d2a46ba9c005cf38.png||alt="image-20221116111427-1.png" height="421" width="705"]]
165 +{{id name="Iimage-20221116111427-1.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_d2a46ba9c005cf38.png||alt="image-20221116111427-1.png" height="421" width="705"]]
188 188  
189 189  Select Connection Channel List
190 190  
191 191  Select Ethernet board communication
192 192  
193 -[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_8f49721a3e5b0ef9.png||alt="image-20221116111451-2.png" height="421" width="705"]]
171 +{{id name="Iimage-20221116111451-2.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_8f49721a3e5b0ef9.png||alt="image-20221116111451-2.png" height="421" width="705"]]
194 194  
195 195  Select Ethernet Module
196 196   Set the IP address of the PLC
197 197  
198 -[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_1e9a9e29a46a1041.png||alt="image-20221116111509-3.png" height="666" width="699"]]
176 +{{id name="Iimage-20221116111509-3.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_1e9a9e29a46a1041.png||alt="image-20221116111509-3.png" height="666" width="699"]]
199 199  
200 200  Read or write PLC data, in this document is read
201 201  
202 202  {{id name="Iimage-20221116111651-4.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_e3d629103727a423.png||alt="image-20221116111651-4.png" height="416" width="697"]]
203 203  
204 -[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_7f29923ebcb670d1.png||alt="image-20221116111727-5.png" height="416" width="697"]]
182 +{{id name="Iimage-20221116111727-5.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_7f29923ebcb670d1.png||alt="image-20221116111727-5.png" height="416" width="697"]]
205 205  
206 -== **FX5U Serial ** ==
184 +**4)Configure the communication protocol**
207 207  
186 +{{id name="Iimage-20221119101946-2.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_b2cdc33b6eb92b67.png||alt="image-20221119101946-2.png" height="395" width="695"]]
187 +
188 +== {{id name="HFX5USerial"/}}**FX5U Serial ** ==
189 +
208 208  Mitsubishi FX5U series PLC
209 209  
210 -**V-BOX Settings**
192 +**1)V-BOX Settings**
211 211  
212 212  |**Item**|**Settings**|**Note**
213 213  |Protocol|Mitsubishi FX5U|
... ... @@ -218,11 +218,8 @@
218 218  |Stop bit|1|
219 219  |PLC station No.|1~~255|Need to be the same as PLC settings
220 220  
221 -(% style="text-align:center" %)
222 -[[image:三菱 FX5U 串口协议配置.png]]
203 +**2)Address List**
223 223  
224 -**Address List**
225 -
226 226  |**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note**
227 227  |(% rowspan="15" %)Bit|X|X|X o|0~~303237|
228 228  |Y|Y|Y o|0~~303237|
... ... @@ -249,36 +249,40 @@
249 249  |D|D|D d|0~~7999|
250 250  |SD|SD|SD d|0~~11999|
251 251  
252 -**PLC Settings (GX Works 3)**
231 +**3)PLC Settings (GX Works 3)**
253 253  
254 254  Create a blank FX5U project
255 255  
256 256  Find the 485 serial port module in the system navigation bar and double click to enter the settings.
257 257  
258 -[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_5c9cb13fac1e6c93.png?width=200&height=462&rev=1.1||alt="12.PLC Protocol_html_5c9cb13fac1e6c93.png" height="462" width="200"]]
237 +{{id name="Ihttps:2F2Fdocs.we-con.com.cn2Fbin2Fdownload2FPIStudio2F12.PLC2520protocols2FWebHome2F12.PLC2520Protocol_html_5c9cb13fac1e6c93.png3Fwidth3D20026height3D46226rev3D1.1"/}}[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_5c9cb13fac1e6c93.png?width=200&height=462&rev=1.1||alt="12.PLC Protocol_html_5c9cb13fac1e6c93.png" height="462" width="200"]]
259 259  
260 260  Select protocol in the setting item, and set parameters.
261 261  
262 -[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_de942589ca070228.png?width=600&height=324&rev=1.1||alt="12.PLC Protocol_html_de942589ca070228.png" height="324" width="600"]]
241 +{{id name="Ihttps:2F2Fdocs.we-con.com.cn2Fbin2Fdownload2FPIStudio2F12.PLC2520protocols2FWebHome2F12.PLC2520Protocol_html_de942589ca070228.png3Fwidth3D60026height3D32426rev3D1.1"/}}[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_de942589ca070228.png?width=600&height=324&rev=1.1||alt="12.PLC Protocol_html_de942589ca070228.png" height="324" width="600"]]
263 263  
264 264  Set station number, and [Message Pattern] (Pattern 1 or Pattern 4)
265 265  
266 -[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_387ec7d00b5feb59.png?width=600&height=323&rev=1.1||alt="12.PLC Protocol_html_387ec7d00b5feb59.png" height="323" width="600"]]
245 +{{id name="Ihttps:2F2Fdocs.we-con.com.cn2Fbin2Fdownload2FPIStudio2F12.PLC2520protocols2FWebHome2F12.PLC2520Protocol_html_387ec7d00b5feb59.png3Fwidth3D60026height3D32326rev3D1.1"/}}[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_387ec7d00b5feb59.png?width=600&height=323&rev=1.1||alt="12.PLC Protocol_html_387ec7d00b5feb59.png" height="323" width="600"]]
267 267  
268 268  Click the [Apply] button to finish the setting.
269 269  
270 270  Click download and select the items as below, then click [execute] to download the configuration to PLC.
271 271  
272 -[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_cdef1c5ec8cc2105.png?width=600&height=434&rev=1.1||alt="12.PLC Protocol_html_cdef1c5ec8cc2105.png" height="434" width="600"]]
251 +{{id name="Ihttps:2F2Fdocs.we-con.com.cn2Fbin2Fdownload2FPIStudio2F12.PLC2520protocols2FWebHome2F12.PLC2520Protocol_html_cdef1c5ec8cc2105.png3Fwidth3D60026height3D43426rev3D1.1"/}}[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_cdef1c5ec8cc2105.png?width=600&height=434&rev=1.1||alt="12.PLC Protocol_html_cdef1c5ec8cc2105.png" height="434" width="600"]]
273 273  
274 274   As soon as download is completed, connect PLC with serial port, then configure it in the [Specify Connection Destination Connection].
275 275  
276 276  Done.
277 277  
278 -**Cable Wiring**
257 +**4)Configure the communication protocol**
279 279  
280 -**RS422**
259 +{{id name="Iimage-20220825104904-1.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_dbaddd53e9951a17.png||alt="image-20220825104904-1.png" height="1033" width="1920"]]
281 281  
261 +**5)Cable Wiring**
262 +
263 +* **RS422**
264 +
282 282  {{id name="Iimage-20220825105105-2.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_d022c5ff4cf8c68e.png||alt="image-20220825105105-2.png" height="288" width="711"]]
283 283  
284 284  {{id name="Iimage-20220825105533-3.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_50e173394c73f154.png||alt="image-20220825105533-3.png" height="246" width="420"]]
... ... @@ -359,11 +359,11 @@
359 359  
360 360  [[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_2297240b57346b2a.png?width=401&height=170&rev=1.1||alt="12.可编程逻辑控制器Protocol_html_2297240b57346b2a.png" height="170" width="401"]]
361 361  
362 -== **L02 Serial ** ==
345 +== {{id name="HL02Serial"/}}**L02 Serial ** ==
363 363  
364 364  Mitsubishi L02 series CPU built-in serial port.
365 365  
366 -**V-BOX Settings**
349 +**1)V-BOX Settings**
367 367  
368 368  |**Item**|**Settings**|**Note**
369 369  |Protocol|Mitsubishi L02|
... ... @@ -374,57 +374,56 @@
374 374  |Stop bit|1|
375 375  |PLC station No.|1~~255|Need to be the same as PLC settings
376 376  
377 -(% style="text-align:center" %)
378 -[[image:三菱 L02串口协议配置.png]]
360 +**2)Address List**
379 379  
380 -**Address List**
381 -
382 382  |**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note**
383 -|(% colspan="1" rowspan="20" %)Bit
384 - |X|X|X h|0~~FFFF|
385 -|Y|Y|Y h|0~~FFFF|
386 -|M|M|M d|0~~9999|
387 -|L|L|L d|0~~9999|
388 -|F|F|F d|0~~9999|
389 -|B|B|B h|0~~FFFF|
390 -|V|V|V d|0~~2047|
391 -|TC|TC|TC d|0~~9999|
392 -|SS|SS|SS d|0~~9999|
393 -|SC|SC|SC d|0~~9999|
394 -|CS|CS|CS d|0~~9999|
395 -|CC|CC|CC d|0~~9999|
396 -|SB|SB|SB h|0~~FFFF|
397 -|SM|SM|SM d|0~~2047|
398 -|STS|STS|STS d|0~~1023|
399 -|S|S|S d|0~~9999|
400 -|DX|DX|DX h|0~~FFFF|
401 -|DY|DY|DY h|0~~FFFF|
402 -|TS|TS|TS d|0~~9999|
403 -|Dbit|Dbit|Dbit d.d|0~~99999.0~~15|
404 -|(% colspan="1" rowspan="9" %)Word
405 - |W|W|W h|0~~FFFF|
406 -|TN|TN|TN d|0~~99999|
407 -|SN|SN|SN d|0~~99999|
408 -|CN|CN|CN d|0~~99999|
409 -|R|R|R d|0~~99999|
410 -|SW|SW|SW h|0~~FFFF|
411 -|Z|Z|Z d|0~~99999|
412 -|ZR|ZR|ZR h|0~~FFFF|
413 -|D|D|D d|0~~99999|
363 +|Bit|X|X|X h|0~~FFFF|
364 +|Bit|Y|Y|Y h|0~~FFFF|
365 +|Bit|M|M|M d|0~~9999|
366 +|Bit|L|L|L d|0~~9999|
367 +|Bit|F|F|F d|0~~9999|
368 +|Bit|B|B|B h|0~~FFFF|
369 +|Bit|V|V|V d|0~~2047|
370 +|Bit|TC|TC|TC d|0~~9999|
371 +|Bit|SS|SS|SS d|0~~9999|
372 +|Bit|SC|SC|SC d|0~~9999|
373 +|Bit|CS|CS|CS d|0~~9999|
374 +|Bit|CC|CC|CC d|0~~9999|
375 +|Bit|SB|SB|SB h|0~~FFFF|
376 +|Bit|SM|SM|SM d|0~~2047|
377 +|Bit|STS|STS|STS d|0~~1023|
378 +|Bit|S|S|S d|0~~9999|
379 +|Bit|DX|DX|DX h|0~~FFFF|
380 +|Bit|DY|DY|DY h|0~~FFFF|
381 +|Bit|TS|TS|TS d|0~~9999|
382 +|Bit|Dbit|Dbit|Dbit d.d|0~~99999.0~~15|
383 +|Word|W|W|W h|0~~FFFF|
384 +|Word|TN|TN|TN d|0~~99999|
385 +|Word|SN|SN|SN d|0~~99999|
386 +|Word|CN|CN|CN d|0~~99999|
387 +|Word|R|R|R d|0~~99999|
388 +|Word|SW|SW|SW h|0~~FFFF|
389 +|Word|Z|Z|Z d|0~~99999|
390 +|Word|ZR|ZR|ZR h|0~~FFFF|
391 +|Word|D|D|D d|0~~99999|
414 414  
415 -**Cable Wiring**
393 +**3)Communication Settings**
416 416  
417 -**RS422**
395 +{{id name="Iimage-20220825160648-3.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_cfed67f2ecb4ccec.png||alt="image-20220825160648-3.png" height="1009" width="1920"]]
418 418  
419 -[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_90e38f152d639809.png||alt="image-20220825161612-8.png" height="278" width="612"]]
397 +**4)Cable Wiring**
420 420  
421 -[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_d301e675d8224725.png||alt="image-20220825160820-4.png" height="208" width="359"]]
399 +* **RS422**
422 422  
423 -== **L02 Ethernet ** ==
401 +{{id name="Iimage-20220825161612-8.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_90e38f152d639809.png||alt="image-20220825161612-8.png" height="278" width="612"]]
424 424  
403 +{{id name="Iimage-20220825160820-4.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_d301e675d8224725.png||alt="image-20220825160820-4.png" height="208" width="359"]]
404 +
405 +== {{id name="HL02Ethernet"/}}**L02 Ethernet ** ==
406 +
425 425  Mitsubishi L series CPU built-in Ethernet port.
426 426  
427 -**V-BOX Settings**
409 +**1)V-BOX Settings**
428 428  
429 429  |**Items**|**Settings**|**Note**
430 430  |Protocol|MIT L02 CPU MELSEC|
... ... @@ -432,11 +432,41 @@
432 432  |Port No.|1025|Must be the same as the PLC setting
433 433  |PLC station No.|0|Must be the same as the PLC setting
434 434  
435 -(% style="text-align:center" %)
436 -[[image:三菱 L02以太网协议配置1.png]]
417 +**2)Address List**
437 437  
438 -**PLC Settings (GX Works2 )**
419 +|**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note**
420 +|Bit|X|X|X h|0~~FFFF|
421 +|Bit|Y|Y|Y h|0~~FFFF|
422 +|Bit|M|M|M d|0~~9999|
423 +|Bit|L|L|L d|0~~9999|
424 +|Bit|F|F|F d|0~~9999|
425 +|Bit|B|B|B h|0~~FFFF|
426 +|Bit|V|V|V d|0~~2047|
427 +|Bit|TC|TC|TC d|0~~9999|
428 +|Bit|SS|SS|SS d|0~~9999|
429 +|Bit|SC|SC|SC d|0~~9999|
430 +|Bit|CS|CS|CS d|0~~9999|
431 +|Bit|CC|CC|CC d|0~~9999|
432 +|Bit|SB|SB|SB h|0~~FFFF|
433 +|Bit|SM|SM|SM d|0~~2047|
434 +|Bit|STS|STS|STS d|0~~1023|
435 +|Bit|S|S|S d|0~~9999|
436 +|Bit|DX|DX|DX h|0~~FFFF|
437 +|Bit|DY|DY|DY h|0~~FFFF|
438 +|Bit|TS|TS|TS d|0~~9999|
439 +|Bit|Dbit|Dbit|Dbit d.d|0~~99999.0~~15|
440 +|Word|W|W|W h|0~~FFFF|
441 +|Word|TN|TN|TN d|0~~99999|
442 +|Word|SN|SN|SN d|0~~99999|
443 +|Word|CN|CN|CN d|0~~99999|
444 +|Word|R|R|R d|0~~99999|
445 +|Word|SW|SW|SW h|0~~FFFF|
446 +|Word|Z|Z|Z d|0~~99999|
447 +|Word|ZR|ZR|ZR h|0~~FFFF|
448 +|Word|D|D|D d|0~~99999|
439 439  
450 +**3)PLC Settings (GX Works2 )**
451 +
440 440  Create a project
441 441  
442 442  Set PLC IP, subnet mask and gateway;
... ... @@ -443,11 +443,11 @@
443 443  
444 444  Select [Binary Code] as communication data code;
445 445  
446 -[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_776e17505f3fc6c0.png?width=600&height=524&rev=1.1||alt="12.PLC Protocol_html_776e17505f3fc6c0.png" height="524" width="600"]]
458 +{{id name="Ihttps:2F2Fdocs.we-con.com.cn2Fbin2Fdownload2FPIStudio2F12.PLC2520protocols2FWebHome2F12.PLC2520Protocol_html_776e17505f3fc6c0.png3Fwidth3D60026height3D52426rev3D1.1"/}}[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_776e17505f3fc6c0.png?width=600&height=524&rev=1.1||alt="12.PLC Protocol_html_776e17505f3fc6c0.png" height="524" width="600"]]
447 447  
448 448  Set PLC port number, for example 1025
449 449  
450 -[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_8d0d1a22d388f70b.png?width=600&height=524&rev=1.1||alt="12.PLC Protocol_html_8d0d1a22d388f70b.png" height="524" width="600"]]
462 +{{id name="Ihttps:2F2Fdocs.we-con.com.cn2Fbin2Fdownload2FPIStudio2F12.PLC2520protocols2FWebHome2F12.PLC2520Protocol_html_8d0d1a22d388f70b.png3Fwidth3D60026height3D52426rev3D1.1"/}}[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_8d0d1a22d388f70b.png?width=600&height=524&rev=1.1||alt="12.PLC Protocol_html_8d0d1a22d388f70b.png" height="524" width="600"]]
451 451  
452 452  Save settings;
453 453  
... ... @@ -455,10 +455,14 @@
455 455  
456 456  Restart PLC device;
457 457  
458 -**Cable Wiring**
470 +**4)Configure the communication protocol**
459 459  
460 -[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_2297240b57346b2a.png?width=401&height=170&rev=1.1||alt="12.PLC Protocol_html_2297240b57346b2a.png" height="170" width="401"]]
472 +{{id name="Iimage-20220825142659-1.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_fafc9b29e20178c0.png||alt="image-20220825142659-1.png" height="1010" width="1920"]]
461 461  
474 +**5)Cable Wiring**
475 +
476 +{{id name="Ihttps:2F2Fdocs.we-con.com.cn2Fbin2Fdownload2FPIStudio2F12.PLC2520protocols2FWebHome2F12.PLC2520Protocol_html_2297240b57346b2a.png3Fwidth3D40126height3D17026rev3D1.1-1"/}}[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_2297240b57346b2a.png?width=401&height=170&rev=1.1||alt="12.PLC Protocol_html_2297240b57346b2a.png" height="170" width="401"]]
477 +
462 462  == {{id name="HQ12HSerial"/}}**Q12H Serial ** ==
463 463  
464 464  This Demo shows V-BOX communicate with Q12H PLC by Q02H serial Protocol
... ... @@ -469,7 +469,7 @@
469 469  
470 470  Mitsubishi QJ71E71 Ethernet communication module;
471 471  
472 -**V-BOX Settings**
488 +**1)V-BOX Settings**
473 473  
474 474  |**Items**|**Settings**|**Note**
475 475  |Protocol|MIT QJ71E71 MELSEC|
... ... @@ -477,10 +477,8 @@
477 477  |Port No.|1025|Must be the same as the PLC setting
478 478  |PLC station No.|0|Must be the same as the PLC setting
479 479  
480 -[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_50990385ef491b9e.png||alt="image-20221119171832-5.png" height="354" width="625"]]
496 +**2)Address List**
481 481  
482 -**Address List**
483 -
484 484  |**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note**
485 485  |(% rowspan="18" %)Bit|X|X|X h|0~~1FFF|
486 486  |Y|Y|Y h|0~~1FFF|
... ... @@ -511,16 +511,16 @@
511 511  |Z|Z|Z d|0~~15|
512 512  |ZR|ZR|ZR h|0~~FE7FF|
513 513  
514 -**PLC Settings(GX Works2)**
528 +**3)PLC Settings(GX Works2)**
515 515  
516 516  * Click [Ethernet/CC IE/MELSECNET];
517 517  * Please select [Ethernet] as network type;
518 518  * Set station I/O number according to situation (For example, 0020 means that the module is connected to PLC CPU in first order);
519 519  * Select [Online] as Mode;
520 -* [[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_d54f23688c520f78.png||alt="image-20221119171343-2.png" height="341" width="587"]]
534 +* {{id name="Iimage-20221119171343-2.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_d54f23688c520f78.png||alt="image-20221119171343-2.png" height="341" width="587"]]
521 521  * Click [Operation setting] to set IP;
522 522  * Select [Binary Code] as [Communication Data Code];
523 -* [[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_ce8e6a671b9508e0.png||alt="image-20221119171436-3.png" height="354" width="588"]]
537 +* {{id name="Iimage-20221119171436-3.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_ce8e6a671b9508e0.png||alt="image-20221119171436-3.png" height="354" width="588"]]
524 524  * Click [Open setting]
525 525  * Set protocol: TCP;
526 526  * Set [unpassive] in [Open system];
... ... @@ -533,6 +533,10 @@
533 533  * {{id name="Iimage-20221119171611-4.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_1d8e2f4fb7c72471.png||alt="image-20221119171611-4.png" height="354" width="588"]]
534 534  * Download project into PLC and restart it
535 535  
536 -**Cable Wiring**
550 +**4)Configure the communication protocol**
537 537  
552 +{{id name="Iimage-20221119171832-5.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_50990385ef491b9e.png||alt="image-20221119171832-5.png" height="354" width="625"]]
553 +
554 +**5)Cable Wiring**
555 +
538 538  [[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_2297240b57346b2a.png?width=401&height=170&rev=1.1||alt="12.可编程逻辑控制器Protocol_html_2297240b57346b2a.png" height="170" width="401"]]
1.2.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.AiXia
Size
... ... @@ -1,1 +1,0 @@
1 -58.0 KB
Content
1.5.1.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.AiXia
Size
... ... @@ -1,1 +1,0 @@
1 -103.4 KB
Content
1.5.2.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.AiXia
Size
... ... @@ -1,1 +1,0 @@
1 -46.6 KB
Content
1694743608503-875.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.AiXia
Size
... ... @@ -1,1 +1,0 @@
1 -98.4 KB
Content
xwiki_PIStudio_12.PLC+protocols_WebHome_1717efe8d969a43c.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.AiXia
Size
... ... @@ -1,1 +1,0 @@
1 -14.8 KB
Content
三菱 FN盒子通讯配置.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.AiXia
Size
... ... @@ -1,1 +1,0 @@
1 -65.5 KB
Content
三菱 FX5U 串口协议配置.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.AiXia
Size
... ... @@ -1,1 +1,0 @@
1 -65.0 KB
Content
三菱 L02 以太网盒子通讯配置.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.AiXia
Size
... ... @@ -1,1 +1,0 @@
1 -66.5 KB
Content
三菱 L02串口协议配置.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.AiXia
Size
... ... @@ -1,1 +1,0 @@
1 -64.4 KB
Content
三菱 L02以太网协议配置1.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.AiXia
Size
... ... @@ -1,1 +1,0 @@
1 -66.7 KB
Content