Changes for page Mitsubishi
Last modified by Joe on 2024/05/21 10:53
From version 58.1
edited by Theodore Xu
on 2023/09/15 11:18
on 2023/09/15 11:18
Change comment:
There is no comment for this version
To version 38.1
edited by Theodore Xu
on 2023/09/15 09:38
on 2023/09/15 09:38
Change comment:
There is no comment for this version
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 0 added, 11 removed)
Details
- Page properties
-
- Content
-
... ... @@ -1,11 +1,11 @@ 1 -= =**FX3U,3G,3GASerial ** ==1 += **FX1S,1N,2N Serial ** = 2 2 3 -Supported Series: Mitsubishi FX 3U, FX3G, FX3GAseries3 +Supported Series: Mitsubishi FX1S, FX1N, FX2N series 4 4 5 5 **V-BOX Settings** 6 6 7 7 |**Item**|**Settings**|**Note** 8 -|Protocol|Mitsubishi FX 3U/3G/3GA|8 +|Protocol|Mitsubishi FX1S/FX1N/FX2N| 9 9 |Connection|RS422/RS485/RS232| 10 10 |Baud rate|9600~~115200| 11 11 |Data bit|7/8| ... ... @@ -13,12 +13,9 @@ 13 13 |Stop bit|1/2| 14 14 |PLC station No.|1~~255| 15 15 16 -(% style="text-align:center" %) 17 -[[image:三菱 FX3U 串口协议配置.png]] 18 - 19 19 **Address List** 20 20 21 -|**Type**|**Device registers**|** HMIregisters**|**Format**|**Range**|**Note**18 +|**Type**|**Device registers**|**V-Box registers**|**Format**|**Range**|**Note** 22 22 |(% rowspan="7" %)Bit|X|X|Xo|0~~303237| 23 23 |Y|Y|Y o|0~~303237| 24 24 |M|M|M d|0~~99999| ... ... @@ -35,60 +35,37 @@ 35 35 |S|S|S d|0~~99999| 36 36 |SD|SD|SD d|8000~~9999| 37 37 38 -** PLCSetting**35 +**Configure the communication protocol** 39 39 40 -Open GX Works2, create a new PLC project or open the project that has been created. 41 -Create new project: [Project]→[New]→[Series] FXCPU→[Type] FX3G/FX3GC→[OK]. 37 +{{id name="Iimage-20220825102844-3.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_dc262f14b14cf564.png||alt="image-20220825102844-3.png" height="1011" width="1920"]] 42 42 43 -(% style="text-align:center" %) 44 -[[image:1.2.png]] 45 - 46 -PLC Default Parameters: 47 -[Connection type]RS422;[Baud rate]9600, [Data bit]7, [Stop bit]1,[Parity]EVEN; [Station number]0 48 -Note:The serial port parameters should be set depending on field requirements 49 - 50 -PC and PLC connection: 51 - 52 -[All connection]→[Connection 1]→[Transfer Setup Connection1]→[Serial USB]→RS-232C: PC and PLC are connected by USB to RS232 adapter,choose corresponding [COM Port]COM 5 →[Transmission speed]9.6Kbps→[setup] →[Parity]EVEN→[Data bits]7→[Stop bits]1→[OK] 53 - 54 -(% style="text-align:center" %) 55 -[[image:1.5.1.png]] 56 - 57 -Connection test:when connection is OK,the GX Works2 prompts “Successfully connected with the FX3G/FX3GCCPU.” 58 - 59 -(% style="text-align:center" %) 60 -[[image:1.5.2.png]] 61 - 62 62 **Cable Wiring** 63 63 64 64 **RS422** 65 65 66 -[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_ 1e904556bb758dfe.png||alt="image-20220825103421-5.png" height="296" width="715"]]43 +[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_9294a40c62eb99be.png||alt="image-20220825103350-4.png" height="284" width="723"]] 67 67 68 68 [[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_860bcf87f6ca7b98.png||alt="image-20220825100845-4.png" height="246" width="419"]] 69 69 70 -== **FX NOPROTOCOL** ==47 +== **FX3U,3G,3GA Serial ** == 71 71 72 -Mitsubishi FX3G -RS232-BD49 +Supported Series: Mitsubishi FX3U, FX3G, FX3GA series 73 73 74 -**V-B oxSettings**51 +**V-BOX Settings** 75 75 76 -| =**Item**|=**Settings**|=**Note**77 -|Protocol|Mitsubishi FX NOPROTOCOL|78 -|Connection|RS232| 79 -|Baud rate|9600| 80 -|Data bit|7| 81 -|Parity|EVEN| 82 -|Stop bit|1| 83 -|PLC station No.| 0|53 +|**Item**|**Settings**|**Note** 54 +|Protocol|Mitsubishi FX3U/3G/3GA| 55 +|Connection|RS422/RS485/RS232| 56 +|Baud rate|9600~~115200| 57 +|Data bit|7/8| 58 +|Parity|EVEN/Odd/None| 59 +|Stop bit|1/2| 60 +|PLC station No.|1~~255| 84 84 85 -(% style="text-align:center" %) 86 -[[image:三菱 FN盒子通讯配置.png]] 87 - 88 88 **Address List** 89 89 90 -| =**Type**|=**Device registers**|=**HMI registers**|=**Format**|=**Range**|=**Note**91 -|(% rowspan=" 8" %)Bit|X|X|X64 +|**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note** 65 +|(% rowspan="7" %)Bit|X|X|Xo|0~~303237| 92 92 |Y|Y|Y o|0~~303237| 93 93 |M|M|M d|0~~99999| 94 94 |T|T|T d|0~~99999| ... ... @@ -95,8 +95,7 @@ 95 95 |C|C|C d|0~~99999| 96 96 |S|S|S d|0~~99999| 97 97 |SM|SM|SM d|8000~~9999| 98 -|Lamp|Lamp|Lamp d|0~~0| 99 -|(% rowspan="8" %)Word|X|X|X o|0~~303237| 72 +|(% rowspan="8" %)Word|X|X|Xo|0~~303237| 100 100 |Y|Y|Y o|0~~303237| 101 101 |M|M|M d|0~~99999| 102 102 |T|T|T d|0~~99999| ... ... @@ -105,15 +105,23 @@ 105 105 |S|S|S d|0~~99999| 106 106 |SD|SD|SD d|8000~~9999| 107 107 108 -**C ableWiring**81 +**Configure the communication protocol** 109 109 110 -[[image:xwiki_ PIStudio_12.PLC+protocols_WebHome_1717efe8d969a43c.png]]83 +[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_4d2a4921240d23c6.png||alt="image-20220825102649-2.png" height="1009" width="1920"]] 111 111 112 - ==**FX3U Ethernet**==85 +**4)Cable Wiring** 113 113 87 +**RS422** 88 + 89 +[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_1e904556bb758dfe.png||alt="image-20220825103421-5.png" height="296" width="715"]] 90 + 91 +[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_860bcf87f6ca7b98.png||alt="image-20220825100845-4.png" height="246" width="419"]] 92 + 93 +== {{id name="HFX3UEthernet"/}}**FX3U Ethernet ** == 94 + 114 114 Supported Modules: FX3U-ENET-ADP, FX3U-ENET-L 115 115 116 -**V-BOX Settings** 97 +**1)V-BOX Settings** 117 117 118 118 |Items|Settings|Note 119 119 |Protocol|Mitsubishi FX3U| ... ... @@ -121,10 +121,8 @@ 121 121 |Port No.|5009|Must be the same as the PLC setting 122 122 |PLC station No.|0| 123 123 124 - [[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_b2cdc33b6eb92b67.png||alt="image-20221119101946-2.png"height="395" width="695"]]105 +**2)Address List** 125 125 126 -**Address List** 127 - 128 128 |**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note** 129 129 |(% rowspan="7" %)Bit|X|X|X OOO|0~~377| 130 130 |Y|Y|Y OOO|0~~377| ... ... @@ -139,19 +139,19 @@ 139 139 |SD|SD|SD DDDD|8000~~8511| 140 140 |R|R|R DDDDD|0~~32767| 141 141 142 -**Ethernet Module Settings** 121 +**3)Ethernet Module Settings** 143 143 144 144 FX3U-ENET-L module configuration 145 145 Set up the FX3U-ENET-L Ethernet module settings as follows. 146 146 Select the module location, which in this document is Module 0. 147 147 148 -[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_949d5d77c1d9cf1e.png||alt="image-20221116105850-1.png" height="573" width="706"]] 127 +{{id name="Iimage-20221116105850-1.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_949d5d77c1d9cf1e.png||alt="image-20221116105850-1.png" height="573" width="706"]] 149 149 150 150 Select "Operational setting" to enter the following screen. 151 151 152 152 The Ethernet module IP is set to 192.168.39.254 in this document, and other options are default. 153 153 154 -[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_dfbfdd586c855c47.png||alt="image-20221116105947-1.png" height="573" width="706"]] 133 +{{id name="Iimage-20221116105947-1.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_dfbfdd586c855c47.png||alt="image-20221116105947-1.png" height="573" width="706"]] 155 155 156 156 Select "Open setting" to enter the setting interface, the settings are as follows. 157 157 ... ... @@ -159,7 +159,7 @@ 159 159 160 160 Mitsubishi programming software GX works2 to communicate with the FX3U via the Ethernet module. 161 161 162 -[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_7c01ac15090fcc5b.png||alt="image-20221116110802-1.png" height="549" width="706"]] 141 +{{id name="Iimage-20221116110802-1.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_7c01ac15090fcc5b.png||alt="image-20221116110802-1.png" height="549" width="706"]] 163 163 164 164 Click on "transter setup" - "PC side I/F setting", see the following figure. 165 165 ... ... @@ -167,46 +167,50 @@ 167 167 168 168 use the IP set in the "Ethernet board" to communicate directly with the network cable. 169 169 170 -[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_d6fd9ce3b96f99e2.png||alt="image-20221116110832-2.png" height="423" width="708"]] 149 +{{id name="Iimage-20221116110832-2.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_d6fd9ce3b96f99e2.png||alt="image-20221116110832-2.png" height="423" width="708"]] 171 171 172 172 Read and write data from the Ethernet module 173 173 174 -[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_690b3e57b29cfd4b.png||alt="image-20221116110907-3.png" height="549" width="706"]] 153 +{{id name="Iimage-20221116110907-3.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_690b3e57b29cfd4b.png||alt="image-20221116110907-3.png" height="549" width="706"]] 175 175 176 176 Set "Transter setup" to COM communication, and read or write operation as shown below 177 177 178 -[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_b317253742f7151.png||alt="image-20221116110917-4.png" height="549" width="706"]] 157 +{{id name="Iimage-20221116110917-4.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_b317253742f7151.png||alt="image-20221116110917-4.png" height="549" width="706"]] 179 179 180 -**PLC Settings (GX Works 2)** 159 +**4)PLC Settings (GX Works 2)** 181 181 182 182 Create a blank FX5U project 183 183 184 184 Find Current Connection in the navigation 185 185 186 -[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_d2a46ba9c005cf38.png||alt="image-20221116111427-1.png" height="421" width="705"]] 165 +{{id name="Iimage-20221116111427-1.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_d2a46ba9c005cf38.png||alt="image-20221116111427-1.png" height="421" width="705"]] 187 187 188 188 Select Connection Channel List 189 189 190 190 Select Ethernet board communication 191 191 192 -[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_8f49721a3e5b0ef9.png||alt="image-20221116111451-2.png" height="421" width="705"]] 171 +{{id name="Iimage-20221116111451-2.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_8f49721a3e5b0ef9.png||alt="image-20221116111451-2.png" height="421" width="705"]] 193 193 194 194 Select Ethernet Module 195 195 Set the IP address of the PLC 196 196 197 -[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_1e9a9e29a46a1041.png||alt="image-20221116111509-3.png" height="666" width="699"]] 176 +{{id name="Iimage-20221116111509-3.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_1e9a9e29a46a1041.png||alt="image-20221116111509-3.png" height="666" width="699"]] 198 198 199 199 Read or write PLC data, in this document is read 200 200 201 201 {{id name="Iimage-20221116111651-4.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_e3d629103727a423.png||alt="image-20221116111651-4.png" height="416" width="697"]] 202 202 203 -[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_7f29923ebcb670d1.png||alt="image-20221116111727-5.png" height="416" width="697"]] 182 +{{id name="Iimage-20221116111727-5.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_7f29923ebcb670d1.png||alt="image-20221116111727-5.png" height="416" width="697"]] 204 204 205 - ==**FX5USerial**==184 +**4)Configure the communication protocol** 206 206 186 +{{id name="Iimage-20221119101946-2.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_b2cdc33b6eb92b67.png||alt="image-20221119101946-2.png" height="395" width="695"]] 187 + 188 +== {{id name="HFX5USerial"/}}**FX5U Serial ** == 189 + 207 207 Mitsubishi FX5U series PLC 208 208 209 -**V-BOX Settings** 192 +**1)V-BOX Settings** 210 210 211 211 |**Item**|**Settings**|**Note** 212 212 |Protocol|Mitsubishi FX5U| ... ... @@ -217,11 +217,8 @@ 217 217 |Stop bit|1| 218 218 |PLC station No.|1~~255|Need to be the same as PLC settings 219 219 220 -(% style="text-align:center" %) 221 -[[image:三菱 FX5U 串口协议配置.png]] 203 +**2)Address List** 222 222 223 -**Address List** 224 - 225 225 |**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note** 226 226 |(% rowspan="15" %)Bit|X|X|X o|0~~303237| 227 227 |Y|Y|Y o|0~~303237| ... ... @@ -248,36 +248,40 @@ 248 248 |D|D|D d|0~~7999| 249 249 |SD|SD|SD d|0~~11999| 250 250 251 -**PLC Settings (GX Works 3)** 231 +**3)PLC Settings (GX Works 3)** 252 252 253 253 Create a blank FX5U project 254 254 255 255 Find the 485 serial port module in the system navigation bar and double click to enter the settings. 256 256 257 -[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_5c9cb13fac1e6c93.png?width=200&height=462&rev=1.1||alt="12.PLC Protocol_html_5c9cb13fac1e6c93.png" height="462" width="200"]] 237 +{{id name="Ihttps:2F2Fdocs.we-con.com.cn2Fbin2Fdownload2FPIStudio2F12.PLC2520protocols2FWebHome2F12.PLC2520Protocol_html_5c9cb13fac1e6c93.png3Fwidth3D20026height3D46226rev3D1.1"/}}[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_5c9cb13fac1e6c93.png?width=200&height=462&rev=1.1||alt="12.PLC Protocol_html_5c9cb13fac1e6c93.png" height="462" width="200"]] 258 258 259 259 Select protocol in the setting item, and set parameters. 260 260 261 -[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_de942589ca070228.png?width=600&height=324&rev=1.1||alt="12.PLC Protocol_html_de942589ca070228.png" height="324" width="600"]] 241 +{{id name="Ihttps:2F2Fdocs.we-con.com.cn2Fbin2Fdownload2FPIStudio2F12.PLC2520protocols2FWebHome2F12.PLC2520Protocol_html_de942589ca070228.png3Fwidth3D60026height3D32426rev3D1.1"/}}[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_de942589ca070228.png?width=600&height=324&rev=1.1||alt="12.PLC Protocol_html_de942589ca070228.png" height="324" width="600"]] 262 262 263 263 Set station number, and [Message Pattern] (Pattern 1 or Pattern 4) 264 264 265 -[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_387ec7d00b5feb59.png?width=600&height=323&rev=1.1||alt="12.PLC Protocol_html_387ec7d00b5feb59.png" height="323" width="600"]] 245 +{{id name="Ihttps:2F2Fdocs.we-con.com.cn2Fbin2Fdownload2FPIStudio2F12.PLC2520protocols2FWebHome2F12.PLC2520Protocol_html_387ec7d00b5feb59.png3Fwidth3D60026height3D32326rev3D1.1"/}}[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_387ec7d00b5feb59.png?width=600&height=323&rev=1.1||alt="12.PLC Protocol_html_387ec7d00b5feb59.png" height="323" width="600"]] 266 266 267 267 Click the [Apply] button to finish the setting. 268 268 269 269 Click download and select the items as below, then click [execute] to download the configuration to PLC. 270 270 271 -[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_cdef1c5ec8cc2105.png?width=600&height=434&rev=1.1||alt="12.PLC Protocol_html_cdef1c5ec8cc2105.png" height="434" width="600"]] 251 +{{id name="Ihttps:2F2Fdocs.we-con.com.cn2Fbin2Fdownload2FPIStudio2F12.PLC2520protocols2FWebHome2F12.PLC2520Protocol_html_cdef1c5ec8cc2105.png3Fwidth3D60026height3D43426rev3D1.1"/}}[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_cdef1c5ec8cc2105.png?width=600&height=434&rev=1.1||alt="12.PLC Protocol_html_cdef1c5ec8cc2105.png" height="434" width="600"]] 272 272 273 273 As soon as download is completed, connect PLC with serial port, then configure it in the [Specify Connection Destination Connection]. 274 274 275 275 Done. 276 276 277 -**C ableWiring**257 +**4)Configure the communication protocol** 278 278 279 - **RS422**259 +{{id name="Iimage-20220825104904-1.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_dbaddd53e9951a17.png||alt="image-20220825104904-1.png" height="1033" width="1920"]] 280 280 261 +**5)Cable Wiring** 262 + 263 +* **RS422** 264 + 281 281 {{id name="Iimage-20220825105105-2.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_d022c5ff4cf8c68e.png||alt="image-20220825105105-2.png" height="288" width="711"]] 282 282 283 283 {{id name="Iimage-20220825105533-3.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_50e173394c73f154.png||alt="image-20220825105533-3.png" height="246" width="420"]] ... ... @@ -358,11 +358,11 @@ 358 358 359 359 [[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_2297240b57346b2a.png?width=401&height=170&rev=1.1||alt="12.可编程逻辑控制器Protocol_html_2297240b57346b2a.png" height="170" width="401"]] 360 360 361 -== **L02 Serial ** == 345 +== {{id name="HL02Serial"/}}**L02 Serial ** == 362 362 363 363 Mitsubishi L02 series CPU built-in serial port. 364 364 365 -**V-BOX Settings** 349 +**1)V-BOX Settings** 366 366 367 367 |**Item**|**Settings**|**Note** 368 368 |Protocol|Mitsubishi L02| ... ... @@ -373,57 +373,56 @@ 373 373 |Stop bit|1| 374 374 |PLC station No.|1~~255|Need to be the same as PLC settings 375 375 376 -(% style="text-align:center" %) 377 -[[image:三菱 L02串口协议配置.png]] 360 +**2)Address List** 378 378 379 -**Address List** 380 - 381 381 |**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note** 382 -|(% colspan="1" rowspan="20" %)Bit 383 - |X|X|X h|0~~FFFF| 384 -|Y|Y|Y h|0~~FFFF| 385 -|M|M|M d|0~~9999| 386 -|L|L|L d|0~~9999| 387 -|F|F|F d|0~~9999| 388 -|B|B|B h|0~~FFFF| 389 -|V|V|V d|0~~2047| 390 -|TC|TC|TC d|0~~9999| 391 -|SS|SS|SS d|0~~9999| 392 -|SC|SC|SC d|0~~9999| 393 -|CS|CS|CS d|0~~9999| 394 -|CC|CC|CC d|0~~9999| 395 -|SB|SB|SB h|0~~FFFF| 396 -|SM|SM|SM d|0~~2047| 397 -|STS|STS|STS d|0~~1023| 398 -|S|S|S d|0~~9999| 399 -|DX|DX|DX h|0~~FFFF| 400 -|DY|DY|DY h|0~~FFFF| 401 -|TS|TS|TS d|0~~9999| 402 -|Dbit|Dbit|Dbit d.d|0~~99999.0~~15| 403 -|(% colspan="1" rowspan="9" %)Word 404 - |W|W|W h|0~~FFFF| 405 -|TN|TN|TN d|0~~99999| 406 -|SN|SN|SN d|0~~99999| 407 -|CN|CN|CN d|0~~99999| 408 -|R|R|R d|0~~99999| 409 -|SW|SW|SW h|0~~FFFF| 410 -|Z|Z|Z d|0~~99999| 411 -|ZR|ZR|ZR h|0~~FFFF| 412 -|D|D|D d|0~~99999| 363 +|Bit|X|X|X h|0~~FFFF| 364 +|Bit|Y|Y|Y h|0~~FFFF| 365 +|Bit|M|M|M d|0~~9999| 366 +|Bit|L|L|L d|0~~9999| 367 +|Bit|F|F|F d|0~~9999| 368 +|Bit|B|B|B h|0~~FFFF| 369 +|Bit|V|V|V d|0~~2047| 370 +|Bit|TC|TC|TC d|0~~9999| 371 +|Bit|SS|SS|SS d|0~~9999| 372 +|Bit|SC|SC|SC d|0~~9999| 373 +|Bit|CS|CS|CS d|0~~9999| 374 +|Bit|CC|CC|CC d|0~~9999| 375 +|Bit|SB|SB|SB h|0~~FFFF| 376 +|Bit|SM|SM|SM d|0~~2047| 377 +|Bit|STS|STS|STS d|0~~1023| 378 +|Bit|S|S|S d|0~~9999| 379 +|Bit|DX|DX|DX h|0~~FFFF| 380 +|Bit|DY|DY|DY h|0~~FFFF| 381 +|Bit|TS|TS|TS d|0~~9999| 382 +|Bit|Dbit|Dbit|Dbit d.d|0~~99999.0~~15| 383 +|Word|W|W|W h|0~~FFFF| 384 +|Word|TN|TN|TN d|0~~99999| 385 +|Word|SN|SN|SN d|0~~99999| 386 +|Word|CN|CN|CN d|0~~99999| 387 +|Word|R|R|R d|0~~99999| 388 +|Word|SW|SW|SW h|0~~FFFF| 389 +|Word|Z|Z|Z d|0~~99999| 390 +|Word|ZR|ZR|ZR h|0~~FFFF| 391 +|Word|D|D|D d|0~~99999| 413 413 414 -**Ca bleWiring**393 +**3)Communication Settings** 415 415 416 - **RS422**395 +{{id name="Iimage-20220825160648-3.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_cfed67f2ecb4ccec.png||alt="image-20220825160648-3.png" height="1009" width="1920"]] 417 417 418 - [[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_90e38f152d639809.png||alt="image-20220825161612-8.png"height="278" width="612"]]397 +**4)Cable Wiring** 419 419 420 - [[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_d301e675d8224725.png||alt="image-20220825160820-4.png" height="208" width="359"]]399 +* **RS422** 421 421 422 - ==**L02Ethernet**==401 +{{id name="Iimage-20220825161612-8.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_90e38f152d639809.png||alt="image-20220825161612-8.png" height="278" width="612"]] 423 423 403 +{{id name="Iimage-20220825160820-4.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_d301e675d8224725.png||alt="image-20220825160820-4.png" height="208" width="359"]] 404 + 405 +== {{id name="HL02Ethernet"/}}**L02 Ethernet ** == 406 + 424 424 Mitsubishi L series CPU built-in Ethernet port. 425 425 426 -**V-BOX Settings** 409 +**1)V-BOX Settings** 427 427 428 428 |**Items**|**Settings**|**Note** 429 429 |Protocol|MIT L02 CPU MELSEC| ... ... @@ -431,11 +431,41 @@ 431 431 |Port No.|1025|Must be the same as the PLC setting 432 432 |PLC station No.|0|Must be the same as the PLC setting 433 433 434 -(% style="text-align:center" %) 435 -[[image:三菱 L02以太网协议配置1.png]] 417 +**2)Address List** 436 436 437 -**PLC Settings (GX Works2 )** 419 +|**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note** 420 +|Bit|X|X|X h|0~~FFFF| 421 +|Bit|Y|Y|Y h|0~~FFFF| 422 +|Bit|M|M|M d|0~~9999| 423 +|Bit|L|L|L d|0~~9999| 424 +|Bit|F|F|F d|0~~9999| 425 +|Bit|B|B|B h|0~~FFFF| 426 +|Bit|V|V|V d|0~~2047| 427 +|Bit|TC|TC|TC d|0~~9999| 428 +|Bit|SS|SS|SS d|0~~9999| 429 +|Bit|SC|SC|SC d|0~~9999| 430 +|Bit|CS|CS|CS d|0~~9999| 431 +|Bit|CC|CC|CC d|0~~9999| 432 +|Bit|SB|SB|SB h|0~~FFFF| 433 +|Bit|SM|SM|SM d|0~~2047| 434 +|Bit|STS|STS|STS d|0~~1023| 435 +|Bit|S|S|S d|0~~9999| 436 +|Bit|DX|DX|DX h|0~~FFFF| 437 +|Bit|DY|DY|DY h|0~~FFFF| 438 +|Bit|TS|TS|TS d|0~~9999| 439 +|Bit|Dbit|Dbit|Dbit d.d|0~~99999.0~~15| 440 +|Word|W|W|W h|0~~FFFF| 441 +|Word|TN|TN|TN d|0~~99999| 442 +|Word|SN|SN|SN d|0~~99999| 443 +|Word|CN|CN|CN d|0~~99999| 444 +|Word|R|R|R d|0~~99999| 445 +|Word|SW|SW|SW h|0~~FFFF| 446 +|Word|Z|Z|Z d|0~~99999| 447 +|Word|ZR|ZR|ZR h|0~~FFFF| 448 +|Word|D|D|D d|0~~99999| 438 438 450 +**3)PLC Settings (GX Works2 )** 451 + 439 439 Create a project 440 440 441 441 Set PLC IP, subnet mask and gateway; ... ... @@ -442,11 +442,11 @@ 442 442 443 443 Select [Binary Code] as communication data code; 444 444 445 -[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_776e17505f3fc6c0.png?width=600&height=524&rev=1.1||alt="12.PLC Protocol_html_776e17505f3fc6c0.png" height="524" width="600"]] 458 +{{id name="Ihttps:2F2Fdocs.we-con.com.cn2Fbin2Fdownload2FPIStudio2F12.PLC2520protocols2FWebHome2F12.PLC2520Protocol_html_776e17505f3fc6c0.png3Fwidth3D60026height3D52426rev3D1.1"/}}[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_776e17505f3fc6c0.png?width=600&height=524&rev=1.1||alt="12.PLC Protocol_html_776e17505f3fc6c0.png" height="524" width="600"]] 446 446 447 447 Set PLC port number, for example 1025 448 448 449 -[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_8d0d1a22d388f70b.png?width=600&height=524&rev=1.1||alt="12.PLC Protocol_html_8d0d1a22d388f70b.png" height="524" width="600"]] 462 +{{id name="Ihttps:2F2Fdocs.we-con.com.cn2Fbin2Fdownload2FPIStudio2F12.PLC2520protocols2FWebHome2F12.PLC2520Protocol_html_8d0d1a22d388f70b.png3Fwidth3D60026height3D52426rev3D1.1"/}}[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_8d0d1a22d388f70b.png?width=600&height=524&rev=1.1||alt="12.PLC Protocol_html_8d0d1a22d388f70b.png" height="524" width="600"]] 450 450 451 451 Save settings; 452 452 ... ... @@ -454,10 +454,14 @@ 454 454 455 455 Restart PLC device; 456 456 457 -**C ableWiring**470 +**4)Configure the communication protocol** 458 458 459 -[[image: https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_2297240b57346b2a.png?width=401&height=170&rev=1.1||alt="12.PLC Protocol_html_2297240b57346b2a.png" height="170" width="401"]]472 +{{id name="Iimage-20220825142659-1.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_fafc9b29e20178c0.png||alt="image-20220825142659-1.png" height="1010" width="1920"]] 460 460 474 +**5)Cable Wiring** 475 + 476 +{{id name="Ihttps:2F2Fdocs.we-con.com.cn2Fbin2Fdownload2FPIStudio2F12.PLC2520protocols2FWebHome2F12.PLC2520Protocol_html_2297240b57346b2a.png3Fwidth3D40126height3D17026rev3D1.1-1"/}}[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_2297240b57346b2a.png?width=401&height=170&rev=1.1||alt="12.PLC Protocol_html_2297240b57346b2a.png" height="170" width="401"]] 477 + 461 461 == {{id name="HQ12HSerial"/}}**Q12H Serial ** == 462 462 463 463 This Demo shows V-BOX communicate with Q12H PLC by Q02H serial Protocol ... ... @@ -468,7 +468,7 @@ 468 468 469 469 Mitsubishi QJ71E71 Ethernet communication module; 470 470 471 -**V-BOX Settings** 488 +**1)V-BOX Settings** 472 472 473 473 |**Items**|**Settings**|**Note** 474 474 |Protocol|MIT QJ71E71 MELSEC| ... ... @@ -476,10 +476,8 @@ 476 476 |Port No.|1025|Must be the same as the PLC setting 477 477 |PLC station No.|0|Must be the same as the PLC setting 478 478 479 - [[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_50990385ef491b9e.png||alt="image-20221119171832-5.png"height="354" width="625"]]496 +**2)Address List** 480 480 481 -**Address List** 482 - 483 483 |**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note** 484 484 |(% rowspan="18" %)Bit|X|X|X h|0~~1FFF| 485 485 |Y|Y|Y h|0~~1FFF| ... ... @@ -510,16 +510,16 @@ 510 510 |Z|Z|Z d|0~~15| 511 511 |ZR|ZR|ZR h|0~~FE7FF| 512 512 513 -**PLC Settings(GX Works2)** 528 +**3)PLC Settings(GX Works2)** 514 514 515 515 * Click [Ethernet/CC IE/MELSECNET]; 516 516 * Please select [Ethernet] as network type; 517 517 * Set station I/O number according to situation (For example, 0020 means that the module is connected to PLC CPU in first order); 518 518 * Select [Online] as Mode; 519 -* [[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_d54f23688c520f78.png||alt="image-20221119171343-2.png" height="341" width="587"]] 534 +* {{id name="Iimage-20221119171343-2.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_d54f23688c520f78.png||alt="image-20221119171343-2.png" height="341" width="587"]] 520 520 * Click [Operation setting] to set IP; 521 521 * Select [Binary Code] as [Communication Data Code]; 522 -* [[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_ce8e6a671b9508e0.png||alt="image-20221119171436-3.png" height="354" width="588"]] 537 +* {{id name="Iimage-20221119171436-3.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_ce8e6a671b9508e0.png||alt="image-20221119171436-3.png" height="354" width="588"]] 523 523 * Click [Open setting] 524 524 * Set protocol: TCP; 525 525 * Set [unpassive] in [Open system]; ... ... @@ -532,6 +532,10 @@ 532 532 * {{id name="Iimage-20221119171611-4.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_1d8e2f4fb7c72471.png||alt="image-20221119171611-4.png" height="354" width="588"]] 533 533 * Download project into PLC and restart it 534 534 535 -**C ableWiring**550 +**4)Configure the communication protocol** 536 536 552 +{{id name="Iimage-20221119171832-5.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_50990385ef491b9e.png||alt="image-20221119171832-5.png" height="354" width="625"]] 553 + 554 +**5)Cable Wiring** 555 + 537 537 [[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_2297240b57346b2a.png?width=401&height=170&rev=1.1||alt="12.可编程逻辑控制器Protocol_html_2297240b57346b2a.png" height="170" width="401"]]
- 1.2.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.AiXia - Size
-
... ... @@ -1,1 +1,0 @@ 1 -58.0 KB - Content
- 1.5.1.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.AiXia - Size
-
... ... @@ -1,1 +1,0 @@ 1 -103.4 KB - Content
- 1.5.2.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.AiXia - Size
-
... ... @@ -1,1 +1,0 @@ 1 -46.6 KB - Content
- 1694743608503-875.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.AiXia - Size
-
... ... @@ -1,1 +1,0 @@ 1 -98.4 KB - Content
- xwiki_PIStudio_12.PLC+protocols_WebHome_1717efe8d969a43c.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.AiXia - Size
-
... ... @@ -1,1 +1,0 @@ 1 -14.8 KB - Content
- 三菱 FN盒子通讯配置.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.AiXia - Size
-
... ... @@ -1,1 +1,0 @@ 1 -65.5 KB - Content
- 三菱 FX3U 串口协议配置.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.AiXia - Size
-
... ... @@ -1,1 +1,0 @@ 1 -65.5 KB - Content
- 三菱 FX5U 串口协议配置.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.AiXia - Size
-
... ... @@ -1,1 +1,0 @@ 1 -65.0 KB - Content
- 三菱 L02 以太网盒子通讯配置.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.AiXia - Size
-
... ... @@ -1,1 +1,0 @@ 1 -66.5 KB - Content
- 三菱 L02串口协议配置.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.AiXia - Size
-
... ... @@ -1,1 +1,0 @@ 1 -64.4 KB - Content
- 三菱 L02以太网协议配置1.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.AiXia - Size
-
... ... @@ -1,1 +1,0 @@ 1 -66.7 KB - Content