Changes for page Mitsubishi

Last modified by Joe on 2024/05/21 10:53

From version 59.1
edited by Theodore Xu
on 2023/09/15 11:25
Change comment: There is no comment for this version
To version 57.1
edited by Theodore Xu
on 2023/09/15 11:13
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -13,9 +13,6 @@
13 13  |Stop bit|1/2|
14 14  |PLC station No.|1~~255|
15 15  
16 -(% style="text-align:center" %)
17 -[[image:三菱 FX3U 串口协议配置.png]]
18 -
19 19  **Address List**
20 20  
21 21  |**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note**
... ... @@ -35,6 +35,10 @@
35 35  |S|S|S d|0~~99999|
36 36  |SD|SD|SD d|8000~~9999|
37 37  
35 +**Configure the communication protocol**
36 +
37 +[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_4d2a4921240d23c6.png||alt="image-20220825102649-2.png" height="1009" width="1920"]]
38 +
38 38  **PLC Setting**
39 39  
40 40  Open GX Works2, create a new PLC project or open the project that has been created.
... ... @@ -286,7 +286,7 @@
286 286  
287 287  Mitsubishi FX5U series PLC
288 288  
289 -**V-BOX Settings**
290 +**1)V-BOX Settings**
290 290  
291 291  |**Items**|**Settings**|**Note**
292 292  |Protocol|Mitsubishi FX5U|
... ... @@ -294,11 +294,8 @@
294 294  |Port No.|5002|Must be the same as the PLC setting
295 295  |PLC station No.|0|
296 296  
297 -(% style="text-align:center" %)
298 -[[image:三菱 FX5U 以太网协议配置.png]]
298 +**2)Address List**
299 299  
300 -**Address List**
301 -
302 302  |**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note**
303 303  |(% rowspan="15" %)Bit|X|X|X o|0~~303237|
304 304  |Y|Y|Y o|0~~303237|
... ... @@ -325,11 +325,11 @@
325 325  |D|D|D d|0~~7999|
326 326  |SD|SD|SD d|0~~11999|
327 327  
328 -**PLC Settings (GX Works 3)**
326 +**3)PLC Settings (GX Works 3)**
329 329  
330 330  Find the [Ethernet port] in the navigation area.
331 331  
332 -[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_8e8f85ace087346c.png?width=300&height=593&rev=1.1||alt="12.PLC Protocol_html_8e8f85ace087346c.png" height="593" width="300"]]
330 +{{id name="Ihttps:2F2Fdocs.we-con.com.cn2Fbin2Fdownload2FPIStudio2F12.PLC2520protocols2FWebHome2F12.PLC2520Protocol_html_8e8f85ace087346c.png3Fwidth3D30026height3D59326rev3D1.1"/}}[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_8e8f85ace087346c.png?width=300&height=593&rev=1.1||alt="12.PLC Protocol_html_8e8f85ace087346c.png" height="593" width="300"]]
333 333  
334 334  Select [Own Node Settings] in the [Setting Item List];
335 335  
... ... @@ -337,7 +337,7 @@
337 337  
338 338  Click [Detailed Settings] into [Ethernet Configuration (Built-in Ethernet Port)] windows;
339 339  
340 -[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_5d98495052c8c10e.png?width=600&height=339&rev=1.1||alt="12.PLC Protocol_html_5d98495052c8c10e.png" height="339" width="600"]]
338 +{{id name="Ihttps:2F2Fdocs.we-con.com.cn2Fbin2Fdownload2FPIStudio2F12.PLC2520protocols2FWebHome2F12.PLC2520Protocol_html_5d98495052c8c10e.png3Fwidth3D60026height3D33926rev3D1.1"/}}[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_5d98495052c8c10e.png?width=600&height=339&rev=1.1||alt="12.PLC Protocol_html_5d98495052c8c10e.png" height="339" width="600"]]
341 341  
342 342  Select [SLMP Connection Module] and add into host station as below picture shows;
343 343  
... ... @@ -345,17 +345,20 @@
345 345  
346 346  Click [Close with Reflecting the Setting] to save and close window;
347 347  
348 -[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_14b489fdc6c6589d.png?width=600&height=350&rev=1.1||alt="12.PLC Protocol_html_14b489fdc6c6589d.png" height="350" width="600"]]
346 +{{id name="Ihttps:2F2Fdocs.we-con.com.cn2Fbin2Fdownload2FPIStudio2F12.PLC2520protocols2FWebHome2F12.PLC2520Protocol_html_14b489fdc6c6589d.png3Fwidth3D60026height3D35026rev3D1.1"/}}[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_14b489fdc6c6589d.png?width=600&height=350&rev=1.1||alt="12.PLC Protocol_html_14b489fdc6c6589d.png" height="350" width="600"]]
349 349  
350 350  Click [Apply] to completed Etherenet settings;
351 351  
352 352  Switch to the [On line data operation] interface as below, check the item and click [Execute] to download.
353 353  
354 -[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_c93025a968a8a9e7.png?width=600&height=434&rev=1.1||alt="12.PLC Protocol_html_c93025a968a8a9e7.png" height="434" width="600"]]
352 +{{id name="Ihttps:2F2Fdocs.we-con.com.cn2Fbin2Fdownload2FPIStudio2F12.PLC2520protocols2FWebHome2F12.PLC2520Protocol_html_c93025a968a8a9e7.png3Fwidth3D60026height3D43426rev3D1.1"/}}[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_c93025a968a8a9e7.png?width=600&height=434&rev=1.1||alt="12.PLC Protocol_html_c93025a968a8a9e7.png" height="434" width="600"]]
355 355  
354 +**4)Configure the communication protocol**
356 356  
357 -**Cable Wiring**
356 +{{id name="Iimage-20220825112403-1.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_caa9bf4d8cc6de0f.png||alt="图片-20220825112403-1.png" height="1033" width="1920"]]
358 358  
358 +**5)Cable Wiring**
359 +
359 359  [[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_2297240b57346b2a.png?width=401&height=170&rev=1.1||alt="12.可编程逻辑控制器Protocol_html_2297240b57346b2a.png" height="170" width="401"]]
360 360  
361 361  == **L02 Serial ** ==
三菱 FX3U 串口协议配置.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.AiXia
Size
... ... @@ -1,1 +1,0 @@
1 -65.5 KB
Content
三菱 FX5U 以太网协议配置.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.AiXia
Size
... ... @@ -1,1 +1,0 @@
1 -64.2 KB
Content