Changes for page Mitsubishi
Last modified by Joe on 2024/05/21 10:53
From version 60.1
edited by Theodore Xu
on 2023/09/15 11:34
on 2023/09/15 11:34
Change comment:
There is no comment for this version
To version 40.1
edited by Theodore Xu
on 2023/09/15 09:39
on 2023/09/15 09:39
Change comment:
There is no comment for this version
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 0 added, 13 removed)
Details
- Page properties
-
- Content
-
... ... @@ -1,11 +1,11 @@ 1 -== **FX 3U,3G,3GASerial ** ==1 +== **FX1S,1N,2N Serial ** == 2 2 3 -Supported Series: Mitsubishi FX 3U, FX3G, FX3GAseries3 +Supported Series: Mitsubishi FX1S, FX1N, FX2N series 4 4 5 5 **V-BOX Settings** 6 6 7 7 |**Item**|**Settings**|**Note** 8 -|Protocol|Mitsubishi FX 3U/3G/3GA|8 +|Protocol|Mitsubishi FX1S/FX1N/FX2N| 9 9 |Connection|RS422/RS485/RS232| 10 10 |Baud rate|9600~~115200| 11 11 |Data bit|7/8| ... ... @@ -13,12 +13,9 @@ 13 13 |Stop bit|1/2| 14 14 |PLC station No.|1~~255| 15 15 16 -(% style="text-align:center" %) 17 -[[image:三菱 FX3U 串口协议配置.png]] 18 - 19 19 **Address List** 20 20 21 -|**Type**|**Device registers**|** HMIregisters**|**Format**|**Range**|**Note**18 +|**Type**|**Device registers**|**V-Box registers**|**Format**|**Range**|**Note** 22 22 |(% rowspan="7" %)Bit|X|X|Xo|0~~303237| 23 23 |Y|Y|Y o|0~~303237| 24 24 |M|M|M d|0~~99999| ... ... @@ -35,60 +35,37 @@ 35 35 |S|S|S d|0~~99999| 36 36 |SD|SD|SD d|8000~~9999| 37 37 38 -** PLCSetting**35 +**Configure the communication protocol** 39 39 40 -Open GX Works2, create a new PLC project or open the project that has been created. 41 -Create new project: [Project]→[New]→[Series] FXCPU→[Type] FX3G/FX3GC→[OK]. 37 +{{id name="Iimage-20220825102844-3.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_dc262f14b14cf564.png||alt="image-20220825102844-3.png" height="1011" width="1920"]] 42 42 43 -(% style="text-align:center" %) 44 -[[image:1.2.png]] 45 - 46 -PLC Default Parameters: 47 -[Connection type]RS422;[Baud rate]9600, [Data bit]7, [Stop bit]1,[Parity]EVEN; [Station number]0 48 -Note:The serial port parameters should be set depending on field requirements 49 - 50 -PC and PLC connection: 51 - 52 -[All connection]→[Connection 1]→[Transfer Setup Connection1]→[Serial USB]→RS-232C: PC and PLC are connected by USB to RS232 adapter,choose corresponding [COM Port]COM 5 →[Transmission speed]9.6Kbps→[setup] →[Parity]EVEN→[Data bits]7→[Stop bits]1→[OK] 53 - 54 -(% style="text-align:center" %) 55 -[[image:1.5.1.png]] 56 - 57 -Connection test:when connection is OK,the GX Works2 prompts “Successfully connected with the FX3G/FX3GCCPU.” 58 - 59 -(% style="text-align:center" %) 60 -[[image:1.5.2.png]] 61 - 62 62 **Cable Wiring** 63 63 64 64 **RS422** 65 65 66 -[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_ 1e904556bb758dfe.png||alt="image-20220825103421-5.png" height="296" width="715"]]43 +[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_9294a40c62eb99be.png||alt="image-20220825103350-4.png" height="284" width="723"]] 67 67 68 68 [[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_860bcf87f6ca7b98.png||alt="image-20220825100845-4.png" height="246" width="419"]] 69 69 70 -== **FX NOPROTOCOL** ==47 +== **FX3U,3G,3GA Serial ** == 71 71 72 -Mitsubishi FX3G -RS232-BD49 +Supported Series: Mitsubishi FX3U, FX3G, FX3GA series 73 73 74 -**V-B oxSettings**51 +**V-BOX Settings** 75 75 76 -| =**Item**|=**Settings**|=**Note**77 -|Protocol|Mitsubishi FX NOPROTOCOL|78 -|Connection|RS232| 79 -|Baud rate|9600| 80 -|Data bit|7| 81 -|Parity|EVEN| 82 -|Stop bit|1| 83 -|PLC station No.| 0|53 +|**Item**|**Settings**|**Note** 54 +|Protocol|Mitsubishi FX3U/3G/3GA| 55 +|Connection|RS422/RS485/RS232| 56 +|Baud rate|9600~~115200| 57 +|Data bit|7/8| 58 +|Parity|EVEN/Odd/None| 59 +|Stop bit|1/2| 60 +|PLC station No.|1~~255| 84 84 85 -(% style="text-align:center" %) 86 -[[image:三菱 FN盒子通讯配置.png]] 87 - 88 88 **Address List** 89 89 90 -| =**Type**|=**Device registers**|=**HMI registers**|=**Format**|=**Range**|=**Note**91 -|(% rowspan=" 8" %)Bit|X|X|X64 +|**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note** 65 +|(% rowspan="7" %)Bit|X|X|Xo|0~~303237| 92 92 |Y|Y|Y o|0~~303237| 93 93 |M|M|M d|0~~99999| 94 94 |T|T|T d|0~~99999| ... ... @@ -95,8 +95,7 @@ 95 95 |C|C|C d|0~~99999| 96 96 |S|S|S d|0~~99999| 97 97 |SM|SM|SM d|8000~~9999| 98 -|Lamp|Lamp|Lamp d|0~~0| 99 -|(% rowspan="8" %)Word|X|X|X o|0~~303237| 72 +|(% rowspan="8" %)Word|X|X|Xo|0~~303237| 100 100 |Y|Y|Y o|0~~303237| 101 101 |M|M|M d|0~~99999| 102 102 |T|T|T d|0~~99999| ... ... @@ -105,15 +105,23 @@ 105 105 |S|S|S d|0~~99999| 106 106 |SD|SD|SD d|8000~~9999| 107 107 108 -**C ableWiring**81 +**Configure the communication protocol** 109 109 110 -[[image:xwiki_ PIStudio_12.PLC+protocols_WebHome_1717efe8d969a43c.png]]83 +[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_4d2a4921240d23c6.png||alt="image-20220825102649-2.png" height="1009" width="1920"]] 111 111 112 - ==**FX3U Ethernet**==85 +**4)Cable Wiring** 113 113 87 +**RS422** 88 + 89 +[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_1e904556bb758dfe.png||alt="image-20220825103421-5.png" height="296" width="715"]] 90 + 91 +[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_860bcf87f6ca7b98.png||alt="image-20220825100845-4.png" height="246" width="419"]] 92 + 93 +== {{id name="HFX3UEthernet"/}}**FX3U Ethernet ** == 94 + 114 114 Supported Modules: FX3U-ENET-ADP, FX3U-ENET-L 115 115 116 -**V-BOX Settings** 97 +**1)V-BOX Settings** 117 117 118 118 |Items|Settings|Note 119 119 |Protocol|Mitsubishi FX3U| ... ... @@ -121,11 +121,8 @@ 121 121 |Port No.|5009|Must be the same as the PLC setting 122 122 |PLC station No.|0| 123 123 124 -(% style="text-align:center" %) 125 -[[image:三菱 FX3U 以太网协议配置.png]] 105 +**2)Address List** 126 126 127 -**Address List** 128 - 129 129 |**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note** 130 130 |(% rowspan="7" %)Bit|X|X|X OOO|0~~377| 131 131 |Y|Y|Y OOO|0~~377| ... ... @@ -140,19 +140,19 @@ 140 140 |SD|SD|SD DDDD|8000~~8511| 141 141 |R|R|R DDDDD|0~~32767| 142 142 143 -**Ethernet Module Settings** 121 +**3)Ethernet Module Settings** 144 144 145 145 FX3U-ENET-L module configuration 146 146 Set up the FX3U-ENET-L Ethernet module settings as follows. 147 147 Select the module location, which in this document is Module 0. 148 148 149 -[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_949d5d77c1d9cf1e.png||alt="image-20221116105850-1.png" height="573" width="706"]] 127 +{{id name="Iimage-20221116105850-1.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_949d5d77c1d9cf1e.png||alt="image-20221116105850-1.png" height="573" width="706"]] 150 150 151 151 Select "Operational setting" to enter the following screen. 152 152 153 153 The Ethernet module IP is set to 192.168.39.254 in this document, and other options are default. 154 154 155 -[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_dfbfdd586c855c47.png||alt="image-20221116105947-1.png" height="573" width="706"]] 133 +{{id name="Iimage-20221116105947-1.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_dfbfdd586c855c47.png||alt="image-20221116105947-1.png" height="573" width="706"]] 156 156 157 157 Select "Open setting" to enter the setting interface, the settings are as follows. 158 158 ... ... @@ -160,7 +160,7 @@ 160 160 161 161 Mitsubishi programming software GX works2 to communicate with the FX3U via the Ethernet module. 162 162 163 -[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_7c01ac15090fcc5b.png||alt="image-20221116110802-1.png" height="549" width="706"]] 141 +{{id name="Iimage-20221116110802-1.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_7c01ac15090fcc5b.png||alt="image-20221116110802-1.png" height="549" width="706"]] 164 164 165 165 Click on "transter setup" - "PC side I/F setting", see the following figure. 166 166 ... ... @@ -168,46 +168,50 @@ 168 168 169 169 use the IP set in the "Ethernet board" to communicate directly with the network cable. 170 170 171 -[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_d6fd9ce3b96f99e2.png||alt="image-20221116110832-2.png" height="423" width="708"]] 149 +{{id name="Iimage-20221116110832-2.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_d6fd9ce3b96f99e2.png||alt="image-20221116110832-2.png" height="423" width="708"]] 172 172 173 173 Read and write data from the Ethernet module 174 174 175 -[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_690b3e57b29cfd4b.png||alt="image-20221116110907-3.png" height="549" width="706"]] 153 +{{id name="Iimage-20221116110907-3.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_690b3e57b29cfd4b.png||alt="image-20221116110907-3.png" height="549" width="706"]] 176 176 177 177 Set "Transter setup" to COM communication, and read or write operation as shown below 178 178 179 -[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_b317253742f7151.png||alt="image-20221116110917-4.png" height="549" width="706"]] 157 +{{id name="Iimage-20221116110917-4.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_b317253742f7151.png||alt="image-20221116110917-4.png" height="549" width="706"]] 180 180 181 -**PLC Settings (GX Works 2)** 159 +**4)PLC Settings (GX Works 2)** 182 182 183 183 Create a blank FX5U project 184 184 185 185 Find Current Connection in the navigation 186 186 187 -[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_d2a46ba9c005cf38.png||alt="image-20221116111427-1.png" height="421" width="705"]] 165 +{{id name="Iimage-20221116111427-1.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_d2a46ba9c005cf38.png||alt="image-20221116111427-1.png" height="421" width="705"]] 188 188 189 189 Select Connection Channel List 190 190 191 191 Select Ethernet board communication 192 192 193 -[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_8f49721a3e5b0ef9.png||alt="image-20221116111451-2.png" height="421" width="705"]] 171 +{{id name="Iimage-20221116111451-2.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_8f49721a3e5b0ef9.png||alt="image-20221116111451-2.png" height="421" width="705"]] 194 194 195 195 Select Ethernet Module 196 196 Set the IP address of the PLC 197 197 198 -[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_1e9a9e29a46a1041.png||alt="image-20221116111509-3.png" height="666" width="699"]] 176 +{{id name="Iimage-20221116111509-3.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_1e9a9e29a46a1041.png||alt="image-20221116111509-3.png" height="666" width="699"]] 199 199 200 200 Read or write PLC data, in this document is read 201 201 202 202 {{id name="Iimage-20221116111651-4.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_e3d629103727a423.png||alt="image-20221116111651-4.png" height="416" width="697"]] 203 203 204 -[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_7f29923ebcb670d1.png||alt="image-20221116111727-5.png" height="416" width="697"]] 182 +{{id name="Iimage-20221116111727-5.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_7f29923ebcb670d1.png||alt="image-20221116111727-5.png" height="416" width="697"]] 205 205 206 - ==**FX5USerial**==184 +**4)Configure the communication protocol** 207 207 186 +{{id name="Iimage-20221119101946-2.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_b2cdc33b6eb92b67.png||alt="image-20221119101946-2.png" height="395" width="695"]] 187 + 188 +== {{id name="HFX5USerial"/}}**FX5U Serial ** == 189 + 208 208 Mitsubishi FX5U series PLC 209 209 210 -**V-BOX Settings** 192 +**1)V-BOX Settings** 211 211 212 212 |**Item**|**Settings**|**Note** 213 213 |Protocol|Mitsubishi FX5U| ... ... @@ -218,11 +218,8 @@ 218 218 |Stop bit|1| 219 219 |PLC station No.|1~~255|Need to be the same as PLC settings 220 220 221 -(% style="text-align:center" %) 222 -[[image:三菱 FX5U 串口协议配置.png]] 203 +**2)Address List** 223 223 224 -**Address List** 225 - 226 226 |**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note** 227 227 |(% rowspan="15" %)Bit|X|X|X o|0~~303237| 228 228 |Y|Y|Y o|0~~303237| ... ... @@ -249,36 +249,40 @@ 249 249 |D|D|D d|0~~7999| 250 250 |SD|SD|SD d|0~~11999| 251 251 252 -**PLC Settings (GX Works 3)** 231 +**3)PLC Settings (GX Works 3)** 253 253 254 254 Create a blank FX5U project 255 255 256 256 Find the 485 serial port module in the system navigation bar and double click to enter the settings. 257 257 258 -[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_5c9cb13fac1e6c93.png?width=200&height=462&rev=1.1||alt="12.PLC Protocol_html_5c9cb13fac1e6c93.png" height="462" width="200"]] 237 +{{id name="Ihttps:2F2Fdocs.we-con.com.cn2Fbin2Fdownload2FPIStudio2F12.PLC2520protocols2FWebHome2F12.PLC2520Protocol_html_5c9cb13fac1e6c93.png3Fwidth3D20026height3D46226rev3D1.1"/}}[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_5c9cb13fac1e6c93.png?width=200&height=462&rev=1.1||alt="12.PLC Protocol_html_5c9cb13fac1e6c93.png" height="462" width="200"]] 259 259 260 260 Select protocol in the setting item, and set parameters. 261 261 262 -[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_de942589ca070228.png?width=600&height=324&rev=1.1||alt="12.PLC Protocol_html_de942589ca070228.png" height="324" width="600"]] 241 +{{id name="Ihttps:2F2Fdocs.we-con.com.cn2Fbin2Fdownload2FPIStudio2F12.PLC2520protocols2FWebHome2F12.PLC2520Protocol_html_de942589ca070228.png3Fwidth3D60026height3D32426rev3D1.1"/}}[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_de942589ca070228.png?width=600&height=324&rev=1.1||alt="12.PLC Protocol_html_de942589ca070228.png" height="324" width="600"]] 263 263 264 264 Set station number, and [Message Pattern] (Pattern 1 or Pattern 4) 265 265 266 -[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_387ec7d00b5feb59.png?width=600&height=323&rev=1.1||alt="12.PLC Protocol_html_387ec7d00b5feb59.png" height="323" width="600"]] 245 +{{id name="Ihttps:2F2Fdocs.we-con.com.cn2Fbin2Fdownload2FPIStudio2F12.PLC2520protocols2FWebHome2F12.PLC2520Protocol_html_387ec7d00b5feb59.png3Fwidth3D60026height3D32326rev3D1.1"/}}[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_387ec7d00b5feb59.png?width=600&height=323&rev=1.1||alt="12.PLC Protocol_html_387ec7d00b5feb59.png" height="323" width="600"]] 267 267 268 268 Click the [Apply] button to finish the setting. 269 269 270 270 Click download and select the items as below, then click [execute] to download the configuration to PLC. 271 271 272 -[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_cdef1c5ec8cc2105.png?width=600&height=434&rev=1.1||alt="12.PLC Protocol_html_cdef1c5ec8cc2105.png" height="434" width="600"]] 251 +{{id name="Ihttps:2F2Fdocs.we-con.com.cn2Fbin2Fdownload2FPIStudio2F12.PLC2520protocols2FWebHome2F12.PLC2520Protocol_html_cdef1c5ec8cc2105.png3Fwidth3D60026height3D43426rev3D1.1"/}}[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_cdef1c5ec8cc2105.png?width=600&height=434&rev=1.1||alt="12.PLC Protocol_html_cdef1c5ec8cc2105.png" height="434" width="600"]] 273 273 274 274 As soon as download is completed, connect PLC with serial port, then configure it in the [Specify Connection Destination Connection]. 275 275 276 276 Done. 277 277 278 -**C ableWiring**257 +**4)Configure the communication protocol** 279 279 280 - **RS422**259 +{{id name="Iimage-20220825104904-1.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_dbaddd53e9951a17.png||alt="image-20220825104904-1.png" height="1033" width="1920"]] 281 281 261 +**5)Cable Wiring** 262 + 263 +* **RS422** 264 + 282 282 {{id name="Iimage-20220825105105-2.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_d022c5ff4cf8c68e.png||alt="image-20220825105105-2.png" height="288" width="711"]] 283 283 284 284 {{id name="Iimage-20220825105533-3.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_50e173394c73f154.png||alt="image-20220825105533-3.png" height="246" width="420"]] ... ... @@ -287,7 +287,7 @@ 287 287 288 288 Mitsubishi FX5U series PLC 289 289 290 -**V-BOX Settings** 273 +**1)V-BOX Settings** 291 291 292 292 |**Items**|**Settings**|**Note** 293 293 |Protocol|Mitsubishi FX5U| ... ... @@ -295,11 +295,8 @@ 295 295 |Port No.|5002|Must be the same as the PLC setting 296 296 |PLC station No.|0| 297 297 298 -(% style="text-align:center" %) 299 -[[image:三菱 FX5U 以太网协议配置.png]] 281 +**2)Address List** 300 300 301 -**Address List** 302 - 303 303 |**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note** 304 304 |(% rowspan="15" %)Bit|X|X|X o|0~~303237| 305 305 |Y|Y|Y o|0~~303237| ... ... @@ -326,11 +326,11 @@ 326 326 |D|D|D d|0~~7999| 327 327 |SD|SD|SD d|0~~11999| 328 328 329 -**PLC Settings (GX Works 3)** 309 +**3)PLC Settings (GX Works 3)** 330 330 331 331 Find the [Ethernet port] in the navigation area. 332 332 333 -[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_8e8f85ace087346c.png?width=300&height=593&rev=1.1||alt="12.PLC Protocol_html_8e8f85ace087346c.png" height="593" width="300"]] 313 +{{id name="Ihttps:2F2Fdocs.we-con.com.cn2Fbin2Fdownload2FPIStudio2F12.PLC2520protocols2FWebHome2F12.PLC2520Protocol_html_8e8f85ace087346c.png3Fwidth3D30026height3D59326rev3D1.1"/}}[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_8e8f85ace087346c.png?width=300&height=593&rev=1.1||alt="12.PLC Protocol_html_8e8f85ace087346c.png" height="593" width="300"]] 334 334 335 335 Select [Own Node Settings] in the [Setting Item List]; 336 336 ... ... @@ -338,7 +338,7 @@ 338 338 339 339 Click [Detailed Settings] into [Ethernet Configuration (Built-in Ethernet Port)] windows; 340 340 341 -[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_5d98495052c8c10e.png?width=600&height=339&rev=1.1||alt="12.PLC Protocol_html_5d98495052c8c10e.png" height="339" width="600"]] 321 +{{id name="Ihttps:2F2Fdocs.we-con.com.cn2Fbin2Fdownload2FPIStudio2F12.PLC2520protocols2FWebHome2F12.PLC2520Protocol_html_5d98495052c8c10e.png3Fwidth3D60026height3D33926rev3D1.1"/}}[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_5d98495052c8c10e.png?width=600&height=339&rev=1.1||alt="12.PLC Protocol_html_5d98495052c8c10e.png" height="339" width="600"]] 342 342 343 343 Select [SLMP Connection Module] and add into host station as below picture shows; 344 344 ... ... @@ -346,24 +346,27 @@ 346 346 347 347 Click [Close with Reflecting the Setting] to save and close window; 348 348 349 -[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_14b489fdc6c6589d.png?width=600&height=350&rev=1.1||alt="12.PLC Protocol_html_14b489fdc6c6589d.png" height="350" width="600"]] 329 +{{id name="Ihttps:2F2Fdocs.we-con.com.cn2Fbin2Fdownload2FPIStudio2F12.PLC2520protocols2FWebHome2F12.PLC2520Protocol_html_14b489fdc6c6589d.png3Fwidth3D60026height3D35026rev3D1.1"/}}[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_14b489fdc6c6589d.png?width=600&height=350&rev=1.1||alt="12.PLC Protocol_html_14b489fdc6c6589d.png" height="350" width="600"]] 350 350 351 351 Click [Apply] to completed Etherenet settings; 352 352 353 353 Switch to the [On line data operation] interface as below, check the item and click [Execute] to download. 354 354 355 -[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_c93025a968a8a9e7.png?width=600&height=434&rev=1.1||alt="12.PLC Protocol_html_c93025a968a8a9e7.png" height="434" width="600"]] 335 +{{id name="Ihttps:2F2Fdocs.we-con.com.cn2Fbin2Fdownload2FPIStudio2F12.PLC2520protocols2FWebHome2F12.PLC2520Protocol_html_c93025a968a8a9e7.png3Fwidth3D60026height3D43426rev3D1.1"/}}[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_c93025a968a8a9e7.png?width=600&height=434&rev=1.1||alt="12.PLC Protocol_html_c93025a968a8a9e7.png" height="434" width="600"]] 356 356 337 +**4)Configure the communication protocol** 357 357 358 - **CableWiring**339 +{{id name="Iimage-20220825112403-1.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_caa9bf4d8cc6de0f.png||alt="图片-20220825112403-1.png" height="1033" width="1920"]] 359 359 341 +**5)Cable Wiring** 342 + 360 360 [[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_2297240b57346b2a.png?width=401&height=170&rev=1.1||alt="12.可编程逻辑控制器Protocol_html_2297240b57346b2a.png" height="170" width="401"]] 361 361 362 -== **L02 Serial ** == 345 +== {{id name="HL02Serial"/}}**L02 Serial ** == 363 363 364 364 Mitsubishi L02 series CPU built-in serial port. 365 365 366 -**V-BOX Settings** 349 +**1)V-BOX Settings** 367 367 368 368 |**Item**|**Settings**|**Note** 369 369 |Protocol|Mitsubishi L02| ... ... @@ -374,57 +374,56 @@ 374 374 |Stop bit|1| 375 375 |PLC station No.|1~~255|Need to be the same as PLC settings 376 376 377 -(% style="text-align:center" %) 378 -[[image:三菱 L02串口协议配置.png]] 360 +**2)Address List** 379 379 380 -**Address List** 381 - 382 382 |**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note** 383 -|(% colspan="1" rowspan="20" %)Bit 384 - |X|X|X h|0~~FFFF| 385 -|Y|Y|Y h|0~~FFFF| 386 -|M|M|M d|0~~9999| 387 -|L|L|L d|0~~9999| 388 -|F|F|F d|0~~9999| 389 -|B|B|B h|0~~FFFF| 390 -|V|V|V d|0~~2047| 391 -|TC|TC|TC d|0~~9999| 392 -|SS|SS|SS d|0~~9999| 393 -|SC|SC|SC d|0~~9999| 394 -|CS|CS|CS d|0~~9999| 395 -|CC|CC|CC d|0~~9999| 396 -|SB|SB|SB h|0~~FFFF| 397 -|SM|SM|SM d|0~~2047| 398 -|STS|STS|STS d|0~~1023| 399 -|S|S|S d|0~~9999| 400 -|DX|DX|DX h|0~~FFFF| 401 -|DY|DY|DY h|0~~FFFF| 402 -|TS|TS|TS d|0~~9999| 403 -|Dbit|Dbit|Dbit d.d|0~~99999.0~~15| 404 -|(% colspan="1" rowspan="9" %)Word 405 - |W|W|W h|0~~FFFF| 406 -|TN|TN|TN d|0~~99999| 407 -|SN|SN|SN d|0~~99999| 408 -|CN|CN|CN d|0~~99999| 409 -|R|R|R d|0~~99999| 410 -|SW|SW|SW h|0~~FFFF| 411 -|Z|Z|Z d|0~~99999| 412 -|ZR|ZR|ZR h|0~~FFFF| 413 -|D|D|D d|0~~99999| 363 +|Bit|X|X|X h|0~~FFFF| 364 +|Bit|Y|Y|Y h|0~~FFFF| 365 +|Bit|M|M|M d|0~~9999| 366 +|Bit|L|L|L d|0~~9999| 367 +|Bit|F|F|F d|0~~9999| 368 +|Bit|B|B|B h|0~~FFFF| 369 +|Bit|V|V|V d|0~~2047| 370 +|Bit|TC|TC|TC d|0~~9999| 371 +|Bit|SS|SS|SS d|0~~9999| 372 +|Bit|SC|SC|SC d|0~~9999| 373 +|Bit|CS|CS|CS d|0~~9999| 374 +|Bit|CC|CC|CC d|0~~9999| 375 +|Bit|SB|SB|SB h|0~~FFFF| 376 +|Bit|SM|SM|SM d|0~~2047| 377 +|Bit|STS|STS|STS d|0~~1023| 378 +|Bit|S|S|S d|0~~9999| 379 +|Bit|DX|DX|DX h|0~~FFFF| 380 +|Bit|DY|DY|DY h|0~~FFFF| 381 +|Bit|TS|TS|TS d|0~~9999| 382 +|Bit|Dbit|Dbit|Dbit d.d|0~~99999.0~~15| 383 +|Word|W|W|W h|0~~FFFF| 384 +|Word|TN|TN|TN d|0~~99999| 385 +|Word|SN|SN|SN d|0~~99999| 386 +|Word|CN|CN|CN d|0~~99999| 387 +|Word|R|R|R d|0~~99999| 388 +|Word|SW|SW|SW h|0~~FFFF| 389 +|Word|Z|Z|Z d|0~~99999| 390 +|Word|ZR|ZR|ZR h|0~~FFFF| 391 +|Word|D|D|D d|0~~99999| 414 414 415 -**Ca bleWiring**393 +**3)Communication Settings** 416 416 417 - **RS422**395 +{{id name="Iimage-20220825160648-3.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_cfed67f2ecb4ccec.png||alt="image-20220825160648-3.png" height="1009" width="1920"]] 418 418 419 - [[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_90e38f152d639809.png||alt="image-20220825161612-8.png"height="278" width="612"]]397 +**4)Cable Wiring** 420 420 421 - [[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_d301e675d8224725.png||alt="image-20220825160820-4.png" height="208" width="359"]]399 +* **RS422** 422 422 423 - ==**L02Ethernet**==401 +{{id name="Iimage-20220825161612-8.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_90e38f152d639809.png||alt="image-20220825161612-8.png" height="278" width="612"]] 424 424 403 +{{id name="Iimage-20220825160820-4.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_d301e675d8224725.png||alt="image-20220825160820-4.png" height="208" width="359"]] 404 + 405 +== {{id name="HL02Ethernet"/}}**L02 Ethernet ** == 406 + 425 425 Mitsubishi L series CPU built-in Ethernet port. 426 426 427 -**V-BOX Settings** 409 +**1)V-BOX Settings** 428 428 429 429 |**Items**|**Settings**|**Note** 430 430 |Protocol|MIT L02 CPU MELSEC| ... ... @@ -432,11 +432,41 @@ 432 432 |Port No.|1025|Must be the same as the PLC setting 433 433 |PLC station No.|0|Must be the same as the PLC setting 434 434 435 -(% style="text-align:center" %) 436 -[[image:三菱 L02以太网协议配置1.png]] 417 +**2)Address List** 437 437 438 -**PLC Settings (GX Works2 )** 419 +|**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note** 420 +|Bit|X|X|X h|0~~FFFF| 421 +|Bit|Y|Y|Y h|0~~FFFF| 422 +|Bit|M|M|M d|0~~9999| 423 +|Bit|L|L|L d|0~~9999| 424 +|Bit|F|F|F d|0~~9999| 425 +|Bit|B|B|B h|0~~FFFF| 426 +|Bit|V|V|V d|0~~2047| 427 +|Bit|TC|TC|TC d|0~~9999| 428 +|Bit|SS|SS|SS d|0~~9999| 429 +|Bit|SC|SC|SC d|0~~9999| 430 +|Bit|CS|CS|CS d|0~~9999| 431 +|Bit|CC|CC|CC d|0~~9999| 432 +|Bit|SB|SB|SB h|0~~FFFF| 433 +|Bit|SM|SM|SM d|0~~2047| 434 +|Bit|STS|STS|STS d|0~~1023| 435 +|Bit|S|S|S d|0~~9999| 436 +|Bit|DX|DX|DX h|0~~FFFF| 437 +|Bit|DY|DY|DY h|0~~FFFF| 438 +|Bit|TS|TS|TS d|0~~9999| 439 +|Bit|Dbit|Dbit|Dbit d.d|0~~99999.0~~15| 440 +|Word|W|W|W h|0~~FFFF| 441 +|Word|TN|TN|TN d|0~~99999| 442 +|Word|SN|SN|SN d|0~~99999| 443 +|Word|CN|CN|CN d|0~~99999| 444 +|Word|R|R|R d|0~~99999| 445 +|Word|SW|SW|SW h|0~~FFFF| 446 +|Word|Z|Z|Z d|0~~99999| 447 +|Word|ZR|ZR|ZR h|0~~FFFF| 448 +|Word|D|D|D d|0~~99999| 439 439 450 +**3)PLC Settings (GX Works2 )** 451 + 440 440 Create a project 441 441 442 442 Set PLC IP, subnet mask and gateway; ... ... @@ -443,11 +443,11 @@ 443 443 444 444 Select [Binary Code] as communication data code; 445 445 446 -[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_776e17505f3fc6c0.png?width=600&height=524&rev=1.1||alt="12.PLC Protocol_html_776e17505f3fc6c0.png" height="524" width="600"]] 458 +{{id name="Ihttps:2F2Fdocs.we-con.com.cn2Fbin2Fdownload2FPIStudio2F12.PLC2520protocols2FWebHome2F12.PLC2520Protocol_html_776e17505f3fc6c0.png3Fwidth3D60026height3D52426rev3D1.1"/}}[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_776e17505f3fc6c0.png?width=600&height=524&rev=1.1||alt="12.PLC Protocol_html_776e17505f3fc6c0.png" height="524" width="600"]] 447 447 448 448 Set PLC port number, for example 1025 449 449 450 -[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_8d0d1a22d388f70b.png?width=600&height=524&rev=1.1||alt="12.PLC Protocol_html_8d0d1a22d388f70b.png" height="524" width="600"]] 462 +{{id name="Ihttps:2F2Fdocs.we-con.com.cn2Fbin2Fdownload2FPIStudio2F12.PLC2520protocols2FWebHome2F12.PLC2520Protocol_html_8d0d1a22d388f70b.png3Fwidth3D60026height3D52426rev3D1.1"/}}[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_8d0d1a22d388f70b.png?width=600&height=524&rev=1.1||alt="12.PLC Protocol_html_8d0d1a22d388f70b.png" height="524" width="600"]] 451 451 452 452 Save settings; 453 453 ... ... @@ -455,10 +455,14 @@ 455 455 456 456 Restart PLC device; 457 457 458 -**C ableWiring**470 +**4)Configure the communication protocol** 459 459 460 -[[image: https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_2297240b57346b2a.png?width=401&height=170&rev=1.1||alt="12.PLC Protocol_html_2297240b57346b2a.png" height="170" width="401"]]472 +{{id name="Iimage-20220825142659-1.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_fafc9b29e20178c0.png||alt="image-20220825142659-1.png" height="1010" width="1920"]] 461 461 474 +**5)Cable Wiring** 475 + 476 +{{id name="Ihttps:2F2Fdocs.we-con.com.cn2Fbin2Fdownload2FPIStudio2F12.PLC2520protocols2FWebHome2F12.PLC2520Protocol_html_2297240b57346b2a.png3Fwidth3D40126height3D17026rev3D1.1-1"/}}[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_2297240b57346b2a.png?width=401&height=170&rev=1.1||alt="12.PLC Protocol_html_2297240b57346b2a.png" height="170" width="401"]] 477 + 462 462 == {{id name="HQ12HSerial"/}}**Q12H Serial ** == 463 463 464 464 This Demo shows V-BOX communicate with Q12H PLC by Q02H serial Protocol ... ... @@ -469,7 +469,7 @@ 469 469 470 470 Mitsubishi QJ71E71 Ethernet communication module; 471 471 472 -**V-BOX Settings** 488 +**1)V-BOX Settings** 473 473 474 474 |**Items**|**Settings**|**Note** 475 475 |Protocol|MIT QJ71E71 MELSEC| ... ... @@ -477,10 +477,8 @@ 477 477 |Port No.|1025|Must be the same as the PLC setting 478 478 |PLC station No.|0|Must be the same as the PLC setting 479 479 480 - [[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_50990385ef491b9e.png||alt="image-20221119171832-5.png"height="354" width="625"]]496 +**2)Address List** 481 481 482 -**Address List** 483 - 484 484 |**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note** 485 485 |(% rowspan="18" %)Bit|X|X|X h|0~~1FFF| 486 486 |Y|Y|Y h|0~~1FFF| ... ... @@ -511,16 +511,16 @@ 511 511 |Z|Z|Z d|0~~15| 512 512 |ZR|ZR|ZR h|0~~FE7FF| 513 513 514 -**PLC Settings(GX Works2)** 528 +**3)PLC Settings(GX Works2)** 515 515 516 516 * Click [Ethernet/CC IE/MELSECNET]; 517 517 * Please select [Ethernet] as network type; 518 518 * Set station I/O number according to situation (For example, 0020 means that the module is connected to PLC CPU in first order); 519 519 * Select [Online] as Mode; 520 -* [[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_d54f23688c520f78.png||alt="image-20221119171343-2.png" height="341" width="587"]] 534 +* {{id name="Iimage-20221119171343-2.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_d54f23688c520f78.png||alt="image-20221119171343-2.png" height="341" width="587"]] 521 521 * Click [Operation setting] to set IP; 522 522 * Select [Binary Code] as [Communication Data Code]; 523 -* [[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_ce8e6a671b9508e0.png||alt="image-20221119171436-3.png" height="354" width="588"]] 537 +* {{id name="Iimage-20221119171436-3.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_ce8e6a671b9508e0.png||alt="image-20221119171436-3.png" height="354" width="588"]] 524 524 * Click [Open setting] 525 525 * Set protocol: TCP; 526 526 * Set [unpassive] in [Open system]; ... ... @@ -533,6 +533,10 @@ 533 533 * {{id name="Iimage-20221119171611-4.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_1d8e2f4fb7c72471.png||alt="image-20221119171611-4.png" height="354" width="588"]] 534 534 * Download project into PLC and restart it 535 535 536 -**C ableWiring**550 +**4)Configure the communication protocol** 537 537 552 +{{id name="Iimage-20221119171832-5.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_50990385ef491b9e.png||alt="image-20221119171832-5.png" height="354" width="625"]] 553 + 554 +**5)Cable Wiring** 555 + 538 538 [[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_2297240b57346b2a.png?width=401&height=170&rev=1.1||alt="12.可编程逻辑控制器Protocol_html_2297240b57346b2a.png" height="170" width="401"]]
- 1.2.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.AiXia - Size
-
... ... @@ -1,1 +1,0 @@ 1 -58.0 KB - Content
- 1.5.1.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.AiXia - Size
-
... ... @@ -1,1 +1,0 @@ 1 -103.4 KB - Content
- 1.5.2.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.AiXia - Size
-
... ... @@ -1,1 +1,0 @@ 1 -46.6 KB - Content
- 1694743608503-875.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.AiXia - Size
-
... ... @@ -1,1 +1,0 @@ 1 -98.4 KB - Content
- xwiki_PIStudio_12.PLC+protocols_WebHome_1717efe8d969a43c.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.AiXia - Size
-
... ... @@ -1,1 +1,0 @@ 1 -14.8 KB - Content
- 三菱 FN盒子通讯配置.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.AiXia - Size
-
... ... @@ -1,1 +1,0 @@ 1 -65.5 KB - Content
- 三菱 FX3U 串口协议配置.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.AiXia - Size
-
... ... @@ -1,1 +1,0 @@ 1 -65.5 KB - Content
- 三菱 FX3U 以太网协议配置.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.AiXia - Size
-
... ... @@ -1,1 +1,0 @@ 1 -64.3 KB - Content
- 三菱 FX5U 串口协议配置.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.AiXia - Size
-
... ... @@ -1,1 +1,0 @@ 1 -65.0 KB - Content
- 三菱 FX5U 以太网协议配置.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.AiXia - Size
-
... ... @@ -1,1 +1,0 @@ 1 -64.2 KB - Content
- 三菱 L02 以太网盒子通讯配置.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.AiXia - Size
-
... ... @@ -1,1 +1,0 @@ 1 -66.5 KB - Content
- 三菱 L02串口协议配置.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.AiXia - Size
-
... ... @@ -1,1 +1,0 @@ 1 -64.4 KB - Content
- 三菱 L02以太网协议配置1.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.AiXia - Size
-
... ... @@ -1,1 +1,0 @@ 1 -66.7 KB - Content