Changes for page Mitsubishi

Last modified by Joe on 2024/05/21 10:53

From version 61.1
edited by Theodore Xu
on 2023/09/15 11:40
Change comment: There is no comment for this version
To version 49.1
edited by Theodore Xu
on 2023/09/15 10:41
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -1,3 +1,49 @@
1 +== **FX1S,1N,2N Serial ** ==
2 +
3 +Supported Series: Mitsubishi FX1S, FX1N, FX2N series
4 +
5 +**V-BOX Settings**
6 +
7 +|**Item**|**Settings**|**Note**
8 +|Protocol|Mitsubishi FX1S/FX1N/FX2N|
9 +|Connection|RS422/RS485/RS232|
10 +|Baud rate|9600~~115200|
11 +|Data bit|7/8|
12 +|Parity|EVEN/Odd/None|
13 +|Stop bit|1/2|
14 +|PLC station No.|1~~255|
15 +
16 +**Address List**
17 +
18 +|**Type**|**Device registers**|**V-Box registers**|**Format**|**Range**|**Note**
19 +|(% rowspan="7" %)Bit|X|X|Xo|0~~303237|
20 +|Y|Y|Y o|0~~303237|
21 +|M|M|M d|0~~99999|
22 +|T|T|T d|0~~99999|
23 +|C|C|C d|0~~99999|
24 +|S|S|S d|0~~99999|
25 +|SM|SM|SM d|8000~~9999|
26 +|(% rowspan="8" %)Word|X|X|Xo|0~~303237|
27 +|Y|Y|Y o|0~~303237|
28 +|M|M|M d|0~~99999|
29 +|T|T|T d|0~~99999|
30 +|C|C|C d|0~~199|
31 +|D|D|D d|0~~7999|
32 +|S|S|S d|0~~99999|
33 +|SD|SD|SD d|8000~~9999|
34 +
35 +**Configure the communication protocol**
36 +
37 +{{id name="Iimage-20220825102844-3.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_dc262f14b14cf564.png||alt="image-20220825102844-3.png" height="1011" width="1920"]]
38 +
39 +**Cable Wiring**
40 +
41 +**RS422**
42 +
43 +[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_9294a40c62eb99be.png||alt="image-20220825103350-4.png" height="284" width="723"]]
44 +
45 +[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_860bcf87f6ca7b98.png||alt="image-20220825100845-4.png" height="246" width="419"]]
46 +
1 1  == **FX3U,3G,3GA Serial ** ==
2 2  
3 3  Supported Series: Mitsubishi FX3U, FX3G, FX3GA series
... ... @@ -13,9 +13,6 @@
13 13  |Stop bit|1/2|
14 14  |PLC station No.|1~~255|
15 15  
16 -(% style="text-align:center" %)
17 -[[image:三菱 FX3U 串口协议配置.png]]
18 -
19 19  **Address List**
20 20  
21 21  |**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note**
... ... @@ -35,6 +35,10 @@
35 35  |S|S|S d|0~~99999|
36 36  |SD|SD|SD d|8000~~9999|
37 37  
81 +**Configure the communication protocol**
82 +
83 +[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_4d2a4921240d23c6.png||alt="image-20220825102649-2.png" height="1009" width="1920"]]
84 +
38 38  **PLC Setting**
39 39  
40 40  Open GX Works2, create a new PLC project or open the project that has been created.
... ... @@ -121,9 +121,6 @@
121 121  |Port No.|5009|Must be the same as the PLC setting
122 122  |PLC station No.|0|
123 123  
124 -(% style="text-align:center" %)
125 -[[image:三菱 FX3U 以太网协议配置.png]]
126 -
127 127  **Address List**
128 128  
129 129  |**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note**
... ... @@ -203,6 +203,10 @@
203 203  
204 204  [[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_7f29923ebcb670d1.png||alt="image-20221116111727-5.png" height="416" width="697"]]
205 205  
250 +**Configure the communication protocol**
251 +
252 +[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_b2cdc33b6eb92b67.png||alt="image-20221119101946-2.png" height="395" width="695"]]
253 +
206 206  == **FX5U Serial ** ==
207 207  
208 208  Mitsubishi FX5U series PLC
... ... @@ -218,9 +218,6 @@
218 218  |Stop bit|1|
219 219  |PLC station No.|1~~255|Need to be the same as PLC settings
220 220  
221 -(% style="text-align:center" %)
222 -[[image:三菱 FX5U 串口协议配置.png]]
223 -
224 224  **Address List**
225 225  
226 226  |**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note**
... ... @@ -275,6 +275,10 @@
275 275  
276 276  Done.
277 277  
323 +**Configure the communication protocol**
324 +
325 +{{id name="Iimage-20220825104904-1.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_dbaddd53e9951a17.png||alt="image-20220825104904-1.png" height="1033" width="1920"]]
326 +
278 278  **Cable Wiring**
279 279  
280 280  **RS422**
... ... @@ -287,7 +287,7 @@
287 287  
288 288  Mitsubishi FX5U series PLC
289 289  
290 -**V-BOX Settings**
339 +**1)V-BOX Settings**
291 291  
292 292  |**Items**|**Settings**|**Note**
293 293  |Protocol|Mitsubishi FX5U|
... ... @@ -295,11 +295,8 @@
295 295  |Port No.|5002|Must be the same as the PLC setting
296 296  |PLC station No.|0|
297 297  
298 -(% style="text-align:center" %)
299 -[[image:三菱 FX5U 以太网协议配置.png]]
347 +**2)Address List**
300 300  
301 -**Address List**
302 -
303 303  |**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note**
304 304  |(% rowspan="15" %)Bit|X|X|X o|0~~303237|
305 305  |Y|Y|Y o|0~~303237|
... ... @@ -326,11 +326,11 @@
326 326  |D|D|D d|0~~7999|
327 327  |SD|SD|SD d|0~~11999|
328 328  
329 -**PLC Settings (GX Works 3)**
375 +**3)PLC Settings (GX Works 3)**
330 330  
331 331  Find the [Ethernet port] in the navigation area.
332 332  
333 -[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_8e8f85ace087346c.png?width=300&height=593&rev=1.1||alt="12.PLC Protocol_html_8e8f85ace087346c.png" height="593" width="300"]]
379 +{{id name="Ihttps:2F2Fdocs.we-con.com.cn2Fbin2Fdownload2FPIStudio2F12.PLC2520protocols2FWebHome2F12.PLC2520Protocol_html_8e8f85ace087346c.png3Fwidth3D30026height3D59326rev3D1.1"/}}[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_8e8f85ace087346c.png?width=300&height=593&rev=1.1||alt="12.PLC Protocol_html_8e8f85ace087346c.png" height="593" width="300"]]
334 334  
335 335  Select [Own Node Settings] in the [Setting Item List];
336 336  
... ... @@ -338,7 +338,7 @@
338 338  
339 339  Click [Detailed Settings] into [Ethernet Configuration (Built-in Ethernet Port)] windows;
340 340  
341 -[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_5d98495052c8c10e.png?width=600&height=339&rev=1.1||alt="12.PLC Protocol_html_5d98495052c8c10e.png" height="339" width="600"]]
387 +{{id name="Ihttps:2F2Fdocs.we-con.com.cn2Fbin2Fdownload2FPIStudio2F12.PLC2520protocols2FWebHome2F12.PLC2520Protocol_html_5d98495052c8c10e.png3Fwidth3D60026height3D33926rev3D1.1"/}}[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_5d98495052c8c10e.png?width=600&height=339&rev=1.1||alt="12.PLC Protocol_html_5d98495052c8c10e.png" height="339" width="600"]]
342 342  
343 343  Select [SLMP Connection Module] and add into host station as below picture shows;
344 344  
... ... @@ -346,17 +346,20 @@
346 346  
347 347  Click [Close with Reflecting the Setting] to save and close window;
348 348  
349 -[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_14b489fdc6c6589d.png?width=600&height=350&rev=1.1||alt="12.PLC Protocol_html_14b489fdc6c6589d.png" height="350" width="600"]]
395 +{{id name="Ihttps:2F2Fdocs.we-con.com.cn2Fbin2Fdownload2FPIStudio2F12.PLC2520protocols2FWebHome2F12.PLC2520Protocol_html_14b489fdc6c6589d.png3Fwidth3D60026height3D35026rev3D1.1"/}}[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_14b489fdc6c6589d.png?width=600&height=350&rev=1.1||alt="12.PLC Protocol_html_14b489fdc6c6589d.png" height="350" width="600"]]
350 350  
351 351  Click [Apply] to completed Etherenet settings;
352 352  
353 353  Switch to the [On line data operation] interface as below, check the item and click [Execute] to download.
354 354  
355 -[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_c93025a968a8a9e7.png?width=600&height=434&rev=1.1||alt="12.PLC Protocol_html_c93025a968a8a9e7.png" height="434" width="600"]]
401 +{{id name="Ihttps:2F2Fdocs.we-con.com.cn2Fbin2Fdownload2FPIStudio2F12.PLC2520protocols2FWebHome2F12.PLC2520Protocol_html_c93025a968a8a9e7.png3Fwidth3D60026height3D43426rev3D1.1"/}}[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_c93025a968a8a9e7.png?width=600&height=434&rev=1.1||alt="12.PLC Protocol_html_c93025a968a8a9e7.png" height="434" width="600"]]
356 356  
403 +**4)Configure the communication protocol**
357 357  
358 -**Cable Wiring**
405 +{{id name="Iimage-20220825112403-1.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_caa9bf4d8cc6de0f.png||alt="图片-20220825112403-1.png" height="1033" width="1920"]]
359 359  
407 +**5)Cable Wiring**
408 +
360 360  [[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_2297240b57346b2a.png?width=401&height=170&rev=1.1||alt="12.可编程逻辑控制器Protocol_html_2297240b57346b2a.png" height="170" width="401"]]
361 361  
362 362  == **L02 Serial ** ==
... ... @@ -374,9 +374,6 @@
374 374  |Stop bit|1|
375 375  |PLC station No.|1~~255|Need to be the same as PLC settings
376 376  
377 -(% style="text-align:center" %)
378 -[[image:三菱 L02串口协议配置.png]]
379 -
380 380  **Address List**
381 381  
382 382  |**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note**
... ... @@ -412,6 +412,10 @@
412 412  |ZR|ZR|ZR h|0~~FFFF|
413 413  |D|D|D d|0~~99999|
414 414  
461 +**Communication Settings**
462 +
463 +[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_cfed67f2ecb4ccec.png||alt="image-20220825160648-3.png" height="1009" width="1920"]]
464 +
415 415  **Cable Wiring**
416 416  
417 417  **RS422**
... ... @@ -432,9 +432,6 @@
432 432  |Port No.|1025|Must be the same as the PLC setting
433 433  |PLC station No.|0|Must be the same as the PLC setting
434 434  
435 -(% style="text-align:center" %)
436 -[[image:三菱 L02以太网协议配置1.png]]
437 -
438 438  **PLC Settings (GX Works2 )**
439 439  
440 440  Create a project
... ... @@ -455,6 +455,10 @@
455 455  
456 456  Restart PLC device;
457 457  
505 +**Configure the communication protocol**
506 +
507 +[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_fafc9b29e20178c0.png||alt="image-20220825142659-1.png" height="1010" width="1920"]]
508 +
458 458  **Cable Wiring**
459 459  
460 460  [[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_2297240b57346b2a.png?width=401&height=170&rev=1.1||alt="12.PLC Protocol_html_2297240b57346b2a.png" height="170" width="401"]]
... ... @@ -469,7 +469,7 @@
469 469  
470 470  Mitsubishi QJ71E71 Ethernet communication module;
471 471  
472 -**V-BOX Settings**
523 +**1)V-BOX Settings**
473 473  
474 474  |**Items**|**Settings**|**Note**
475 475  |Protocol|MIT QJ71E71 MELSEC|
... ... @@ -477,11 +477,8 @@
477 477  |Port No.|1025|Must be the same as the PLC setting
478 478  |PLC station No.|0|Must be the same as the PLC setting
479 479  
480 -(% style="text-align:center" %)
481 -[[image:三菱 QJ71 以太网协议配置.png]]
531 +**2)Address List**
482 482  
483 -**Address List**
484 -
485 485  |**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note**
486 486  |(% rowspan="18" %)Bit|X|X|X h|0~~1FFF|
487 487  |Y|Y|Y h|0~~1FFF|
... ... @@ -512,16 +512,16 @@
512 512  |Z|Z|Z d|0~~15|
513 513  |ZR|ZR|ZR h|0~~FE7FF|
514 514  
515 -**PLC Settings(GX Works2)**
563 +**3)PLC Settings(GX Works2)**
516 516  
517 517  * Click [Ethernet/CC IE/MELSECNET];
518 518  * Please select [Ethernet] as network type;
519 519  * Set station I/O number according to situation (For example, 0020 means that the module is connected to PLC CPU in first order);
520 520  * Select [Online] as Mode;
521 -* [[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_d54f23688c520f78.png||alt="image-20221119171343-2.png" height="341" width="587"]]
569 +* {{id name="Iimage-20221119171343-2.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_d54f23688c520f78.png||alt="image-20221119171343-2.png" height="341" width="587"]]
522 522  * Click [Operation setting] to set IP;
523 523  * Select [Binary Code] as [Communication Data Code];
524 -* [[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_ce8e6a671b9508e0.png||alt="image-20221119171436-3.png" height="354" width="588"]]
572 +* {{id name="Iimage-20221119171436-3.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_ce8e6a671b9508e0.png||alt="image-20221119171436-3.png" height="354" width="588"]]
525 525  * Click [Open setting]
526 526  * Set protocol: TCP;
527 527  * Set [unpassive] in [Open system];
... ... @@ -534,6 +534,10 @@
534 534  * {{id name="Iimage-20221119171611-4.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_1d8e2f4fb7c72471.png||alt="image-20221119171611-4.png" height="354" width="588"]]
535 535  * Download project into PLC and restart it
536 536  
537 -**Cable Wiring**
585 +**4)Configure the communication protocol**
538 538  
587 +{{id name="Iimage-20221119171832-5.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_50990385ef491b9e.png||alt="image-20221119171832-5.png" height="354" width="625"]]
588 +
589 +**5)Cable Wiring**
590 +
539 539  [[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_2297240b57346b2a.png?width=401&height=170&rev=1.1||alt="12.可编程逻辑控制器Protocol_html_2297240b57346b2a.png" height="170" width="401"]]
三菱 FX3U 串口协议配置.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.AiXia
Size
... ... @@ -1,1 +1,0 @@
1 -65.5 KB
Content
三菱 FX3U 以太网协议配置.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.AiXia
Size
... ... @@ -1,1 +1,0 @@
1 -64.3 KB
Content
三菱 FX5U 串口协议配置.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.AiXia
Size
... ... @@ -1,1 +1,0 @@
1 -65.0 KB
Content
三菱 FX5U 以太网协议配置.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.AiXia
Size
... ... @@ -1,1 +1,0 @@
1 -64.2 KB
Content
三菱 L02 以太网盒子通讯配置.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.AiXia
Size
... ... @@ -1,1 +1,0 @@
1 -66.5 KB
Content
三菱 L02串口协议配置.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.AiXia
Size
... ... @@ -1,1 +1,0 @@
1 -64.4 KB
Content
三菱 L02以太网协议配置1.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.AiXia
Size
... ... @@ -1,1 +1,0 @@
1 -66.7 KB
Content
三菱 QJ71 以太网协议配置.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.AiXia
Size
... ... @@ -1,1 +1,0 @@
1 -66.6 KB
Content