Changes for page Mitsubishi
Last modified by Joe on 2024/05/21 10:53
From version 75.1
edited by Theodore Xu
on 2023/09/15 11:57
on 2023/09/15 11:57
Change comment:
There is no comment for this version
To version 75.2
edited by Theodore Xu
on 2023/09/15 18:15
on 2023/09/15 18:15
Change comment:
There is no comment for this version
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 2 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -327,34 +327,16 @@ 327 327 |SD|SD d|0~~11999| 328 328 329 329 **PLC Settings (GX Works 3)** 330 +[Navigation]→[Parameter]→[FX5UCPU]→[Module Parameter]→[Ethernet Port]:[Basic Settings]→ [Own node settings]:[IP Address]192.168.40.11, [Subnet Mask]255.255.255.0, [Default Gateway]192.168.40.1,[ Communication Data Code] Binary. 330 330 331 -Find the [Ethernet port] in the navigation area. 332 +(% style="text-align:center" %) 333 +[[image:1.3.1.png]] 332 332 333 -[ [image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_8e8f85ace087346c.png?width=300&height=593&rev=1.1||alt="12.PLCProtocol_html_8e8f85ace087346c.png"height="593"width="300"]]335 +[External Device Configuration]→[Detailed Settings]→[Ethernet Configuration(Built-in Ethernet Port)]→[Ethernet Device (General)]→[SLMP Connection Module] Drag under Host for Connection No.1→[Port No.]5002→[Close with Reflecting the Setting] 334 334 335 -Select [Own Node Settings] in the [Setting Item List]; 337 +(% style="text-align:center" %) 338 +[[image:1.3.2.png]] 336 336 337 -Set [IP Address], [Subnet Mask], [Default Gateway]; 338 - 339 -Click [Detailed Settings] into [Ethernet Configuration (Built-in Ethernet Port)] windows; 340 - 341 -[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_5d98495052c8c10e.png?width=600&height=339&rev=1.1||alt="12.PLC Protocol_html_5d98495052c8c10e.png" height="339" width="600"]] 342 - 343 -Select [SLMP Connection Module] and add into host station as below picture shows; 344 - 345 -Set Port number as 5002 (this is necessary settings); 346 - 347 -Click [Close with Reflecting the Setting] to save and close window; 348 - 349 -[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_14b489fdc6c6589d.png?width=600&height=350&rev=1.1||alt="12.PLC Protocol_html_14b489fdc6c6589d.png" height="350" width="600"]] 350 - 351 -Click [Apply] to completed Etherenet settings; 352 - 353 -Switch to the [On line data operation] interface as below, check the item and click [Execute] to download. 354 - 355 -[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_c93025a968a8a9e7.png?width=600&height=434&rev=1.1||alt="12.PLC Protocol_html_c93025a968a8a9e7.png" height="434" width="600"]] 356 - 357 - 358 358 **Cable Wiring** 359 359 360 360 [[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_2297240b57346b2a.png?width=401&height=170&rev=1.1||alt="12.可编程逻辑控制器Protocol_html_2297240b57346b2a.png" height="170" width="401"]]
- 1.3.1.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.AiXia - Size
-
... ... @@ -1,0 +1,1 @@ 1 +107.7 KB - Content
- 1.3.2.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.AiXia - Size
-
... ... @@ -1,0 +1,1 @@ 1 +131.6 KB - Content