... ... @@ -327,34 +327,16 @@
327 327  |SD|SD d|0~~11999|
328 328  
329 329  **PLC Settings (GX Works 3)**
330 +[Navigation]→[Parameter]→[FX5UCPU]→[Module Parameter]→[Ethernet Port]:[Basic Settings]→ [Own node settings]:[IP Address]192.168.40.11, [Subnet Mask]255.255.255.0, [Default Gateway]192.168.40.1,[ Communication Data Code] Binary.
330 330  
331 -Find the [Ethernet port] in the navigation area.
332 +(% style="text-align:center" %)
333 +[[image:1.3.1.png]]
332 332  
333 -[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_8e8f85ace087346c.png?width=300&height=593&rev=1.1||alt="12.PLC Protocol_html_8e8f85ace087346c.png" height="593" width="300"]]
335 +[External Device Configuration]→[Detailed Settings]→[Ethernet Configuration(Built-in Ethernet Port)]→[Ethernet Device (General)]→[SLMP Connection Module] Drag under Host for Connection No.1→[Port No.]5002→[Close with Reflecting the Setting]
334 334  
335 -Select [Own Node Settings] in the [Setting Item List];
337 +(% style="text-align:center" %)
338 +[[image:1.3.2.png]]
336 336  
337 -Set [IP Address], [Subnet Mask], [Default Gateway];
338 -
339 -Click [Detailed Settings] into [Ethernet Configuration (Built-in Ethernet Port)] windows;
340 -
341 -[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_5d98495052c8c10e.png?width=600&height=339&rev=1.1||alt="12.PLC Protocol_html_5d98495052c8c10e.png" height="339" width="600"]]
342 -
343 -Select [SLMP Connection Module] and add into host station as below picture shows;
344 -
345 -Set Port number as 5002 (this is necessary settings);
346 -
347 -Click [Close with Reflecting the Setting] to save and close window;
348 -
349 -[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_14b489fdc6c6589d.png?width=600&height=350&rev=1.1||alt="12.PLC Protocol_html_14b489fdc6c6589d.png" height="350" width="600"]]
350 -
351 -Click [Apply] to completed Etherenet settings;
352 -
353 -Switch to the [On line data operation] interface as below, check the item and click [Execute] to download.
354 -
355 -[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_c93025a968a8a9e7.png?width=600&height=434&rev=1.1||alt="12.PLC Protocol_html_c93025a968a8a9e7.png" height="434" width="600"]]
356 -
357 -
358 358  **Cable Wiring**
359 359  
360 360  [[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_2297240b57346b2a.png?width=401&height=170&rev=1.1||alt="12.可编程逻辑控制器Protocol_html_2297240b57346b2a.png" height="170" width="401"]]
1.3.1.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.AiXia
Size
... ... @@ -1,0 +1,1 @@
1 +107.7 KB
Content
1.3.2.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.AiXia
Size
... ... @@ -1,0 +1,1 @@
1 +131.6 KB
Content