Changes for page Mitsubishi
Last modified by Joe on 2024/05/21 10:53
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 7 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -19,7 +19,7 @@ 19 19 **Address List** 20 20 21 21 |**Type**|**Device registers**|**Format**|**Range**|**Note** 22 -|(% rowspan="7" %)Bit|X|Xo|0~~303237| 22 +|(% rowspan="7" %)Bit|X|X o|0~~303237| 23 23 |Y|Y o|0~~303237| 24 24 |M|M d|0~~99999| 25 25 |T|T d|0~~99999| ... ... @@ -26,7 +26,7 @@ 26 26 |C|C d|0~~99999| 27 27 |S|S d|0~~99999| 28 28 |SM|SM d|8000~~9999| 29 -|(% rowspan="8" %)Word|X|Xo|0~~303237| 29 +|(% rowspan="8" %)Word|X|X o|0~~303237| 30 30 |Y|Y o|0~~303237| 31 31 |M|M d|0~~99999| 32 32 |T|T d|0~~99999| ... ... @@ -159,8 +159,10 @@ 159 159 Select "Operational setting" to enter the following screen. 160 160 161 161 The Ethernet module IP is set to 192.168.39.254 in this document, and other options are default. 162 + 162 162 163 -[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_dfbfdd586c855c47.png||alt="image-20221116105947-1.png" height="573" width="706"]] 164 +(% style="text-align:center" %) 165 +[[image:Inku25HyY8.png]] 164 164 165 165 Select "Open setting" to enter the setting interface, the settings are as follows. 166 166 ... ... @@ -170,22 +170,26 @@ 170 170 171 171 [[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_7c01ac15090fcc5b.png||alt="image-20221116110802-1.png" height="549" width="706"]] 172 172 175 +(% class="box infomessage" %) 176 +((( 177 +Note: If you can't communicate PLC to box normally, changing ''No confirm" to "confirm" 178 +))) 179 + 173 173 Click on "transter setup" - "PC side I/F setting", see the following figure. 174 174 175 175 After setting, the first download must use the programming cable, as shown in the figure; after that, can 176 176 177 177 use the IP set in the "Ethernet board" to communicate directly with the network cable. 185 + 178 178 179 -[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_d6fd9ce3b96f99e2.png||alt="image-20221116110832-2.png" height="423" width="708"]] 187 +(% style="text-align:center" %) 188 +[[image:WstTyoGrxG.png]] 180 180 181 -Read and write data from the Ethernet module 190 +(% style="text-align:center" %) 191 +[[image:aak9XC8xDH.png]] 182 182 183 -[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_690b3e57b29cfd4b.png||alt="image-20221116110907-3.png" height="549" width="706"]] 184 184 185 -Set "Transter setup" to COM communication, and read or write operation as shown below 186 186 187 -[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_b317253742f7151.png||alt="image-20221116110917-4.png" height="549" width="706"]] 188 - 189 189 **PLC Settings (GX Works 2)** 190 190 191 191 Create a blank FX5U project ... ... @@ -608,27 +608,38 @@ 608 608 (% class="wikigeneratedid" %) 609 609 PC and PLC connection: 610 610 611 -(% class="wikigeneratedid" %) 612 -Online→Read from PLC→choose PLC Series→OK→serial USB→OK→Choose Parameter、Global Device Comment and Device Memory→Execute→OK→Choose 617 +* Online→Read from PLC 613 613 614 614 (% style="text-align:center" %) 615 615 [[image:1.png]] 616 616 622 +* choose PLC Series→OK 623 + 617 617 (% style="text-align:center" %) 618 618 [[image:StqCG53paq.png]] 619 619 627 +* serial USB→OK 628 + 620 620 (% style="text-align:center" %) 621 621 [[image:Y7H80eq2Eb.png]] 622 622 632 +* Choose Parameter、Global Device Comment and Device Memory→Execute 633 + 623 623 (% style="text-align:center" %) 624 624 [[image:6PAsdFz58I.png]] 625 625 637 +* OK→wait loading successfully→Close 638 + 626 626 (% style="text-align:center" %) 627 627 [[image:0GBGUNn4hQ.png]] 628 628 642 +* Navigation→Parameter→PLC Parameter→IP Address Setting→Built-in Ethernet Port Setting→Host Station(Same as the port on V-box)→End 643 + 629 629 (% style="text-align:center" %) 630 630 [[image:Ypyl4SUHcf.png]] 631 631 647 +* Debug→Start/ Stop Simulation→wait loading successfully→Close 648 + 632 632 (% style="text-align:center" %) 633 633 [[image:ZmUzFbS39y.png]] 634 634 ... ... @@ -635,3 +635,6 @@ 635 635 (% style="text-align:center" %) 636 636 [[image:ehoO3C6bry.png]] 637 637 655 +(% id="cke_bm_1296534S" style="display:none" %)** **(%%)**Cable Wiring** 656 + 657 +[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_2297240b57346b2a.png?width=401&height=170&rev=1.1||alt="12.可编程逻辑控制器Protocol_html_2297240b57346b2a.png" height="170" width="401"]]
- 894qM2hnau.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.joe - Size
-
... ... @@ -1,0 +1,1 @@ 1 +20.4 KB - Content
- Inku25HyY8.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.joe - Size
-
... ... @@ -1,0 +1,1 @@ 1 +19.6 KB - Content
- WstTyoGrxG.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.joe - Size
-
... ... @@ -1,0 +1,1 @@ 1 +99.1 KB - Content
- aak9XC8xDH.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.joe - Size
-
... ... @@ -1,0 +1,1 @@ 1 +48.4 KB - Content
- aoZAhFYHA4.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.joe - Size
-
... ... @@ -1,0 +1,1 @@ 1 +20.4 KB - Content
- qoQNWSBoEQ.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.joe - Size
-
... ... @@ -1,0 +1,1 @@ 1 +98.4 KB - Content
- xzZboZHffh.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.joe - Size
-
... ... @@ -1,0 +1,1 @@ 1 +100.3 KB - Content