Changes for page Mitsubishi

Last modified by Joe on 2024/05/21 10:53

From version 83.13
edited by Joe
on 2024/03/13 18:38
Change comment: There is no comment for this version
To version 87.1
edited by Joe
on 2024/05/21 10:53
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -19,7 +19,7 @@
19 19  **Address List**
20 20  
21 21  |**Type**|**Device registers**|**Format**|**Range**|**Note**
22 -|(% rowspan="7" %)Bit|X|Xo|0~~303237|
22 +|(% rowspan="7" %)Bit|X|X o|0~~303237|
23 23  |Y|Y o|0~~303237|
24 24  |M|M d|0~~99999|
25 25  |T|T d|0~~99999|
... ... @@ -26,7 +26,7 @@
26 26  |C|C d|0~~99999|
27 27  |S|S d|0~~99999|
28 28  |SM|SM d|8000~~9999|
29 -|(% rowspan="8" %)Word|X|Xo|0~~303237|
29 +|(% rowspan="8" %)Word|X|X o|0~~303237|
30 30  |Y|Y o|0~~303237|
31 31  |M|M d|0~~99999|
32 32  |T|T d|0~~99999|
... ... @@ -159,8 +159,10 @@
159 159  Select "Operational setting" to enter the following screen.
160 160  
161 161  The Ethernet module IP is set to 192.168.39.254 in this document, and other options are default.
162 +
162 162  
163 -[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_dfbfdd586c855c47.png||alt="image-20221116105947-1.png" height="573" width="706"]]
164 +(% style="text-align:center" %)
165 +[[image:Inku25HyY8.png]]
164 164  
165 165  Select "Open setting" to enter the setting interface, the settings are as follows.
166 166  
... ... @@ -170,22 +170,26 @@
170 170  
171 171  [[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_7c01ac15090fcc5b.png||alt="image-20221116110802-1.png" height="549" width="706"]]
172 172  
175 +(% class="box infomessage" %)
176 +(((
177 +Note: If you can't communicate PLC to box normally, changing ''No confirm" to "confirm"
178 +)))
179 +
173 173  Click on "transter setup" - "PC side I/F setting", see the following figure.
174 174  
175 175  After setting, the first download must use the programming cable, as shown in the figure; after that, can
176 176  
177 177  use the IP set in the "Ethernet board" to communicate directly with the network cable.
185 +
178 178  
179 -[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_d6fd9ce3b96f99e2.png||alt="image-20221116110832-2.png" height="423" width="708"]]
187 +(% style="text-align:center" %)
188 +[[image:WstTyoGrxG.png]]
180 180  
181 -Read and write data from the Ethernet module
190 +(% style="text-align:center" %)
191 +[[image:aak9XC8xDH.png]]
182 182  
183 -[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_690b3e57b29cfd4b.png||alt="image-20221116110907-3.png" height="549" width="706"]]
184 184  
185 -Set "Transter setup" to COM communication, and read or write operation as shown below
186 186  
187 -[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_b317253742f7151.png||alt="image-20221116110917-4.png" height="549" width="706"]]
188 -
189 189  **PLC Settings (GX Works 2)**
190 190  
191 191  Create a blank FX5U project
... ... @@ -608,27 +608,38 @@
608 608  (% class="wikigeneratedid" %)
609 609  PC and PLC connection:
610 610  
611 -(% class="wikigeneratedid" %)
612 -Online→Read from PLC→choose PLC Series→OK→serial USB→OK→Choose Parameter、Global Device Comment and Device Memory→Execute→OK→Choose
617 +* Online→Read from PLC
613 613  
614 614  (% style="text-align:center" %)
615 615  [[image:1.png]]
616 616  
622 +* choose PLC Series→OK
623 +
617 617  (% style="text-align:center" %)
618 618  [[image:StqCG53paq.png]]
619 619  
627 +* serial USB→OK
628 +
620 620  (% style="text-align:center" %)
621 621  [[image:Y7H80eq2Eb.png]]
622 622  
632 +* Choose Parameter、Global Device Comment and Device Memory→Execute
633 +
623 623  (% style="text-align:center" %)
624 624  [[image:6PAsdFz58I.png]]
625 625  
637 +* OK→wait loading successfully→Close
638 +
626 626  (% style="text-align:center" %)
627 627  [[image:0GBGUNn4hQ.png]]
628 628  
642 +* Navigation→Parameter→PLC Parameter→IP Address Setting→Built-in Ethernet Port Setting→Host Station(Same as the port on  V-box)→End
643 +
629 629  (% style="text-align:center" %)
630 630  [[image:Ypyl4SUHcf.png]]
631 631  
647 +* Debug→Start/ Stop Simulation→wait loading successfully→Close
648 +
632 632  (% style="text-align:center" %)
633 633  [[image:ZmUzFbS39y.png]]
634 634  
... ... @@ -635,3 +635,6 @@
635 635  (% style="text-align:center" %)
636 636  [[image:ehoO3C6bry.png]]
637 637  
655 +(% id="cke_bm_1296534S" style="display:none" %)** **(%%)**Cable Wiring**
656 +
657 +[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_2297240b57346b2a.png?width=401&height=170&rev=1.1||alt="12.可编程逻辑控制器Protocol_html_2297240b57346b2a.png" height="170" width="401"]]
894qM2hnau.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.joe
Size
... ... @@ -1,0 +1,1 @@
1 +20.4 KB
Content
Inku25HyY8.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.joe
Size
... ... @@ -1,0 +1,1 @@
1 +19.6 KB
Content
WstTyoGrxG.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.joe
Size
... ... @@ -1,0 +1,1 @@
1 +99.1 KB
Content
aak9XC8xDH.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.joe
Size
... ... @@ -1,0 +1,1 @@
1 +48.4 KB
Content
aoZAhFYHA4.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.joe
Size
... ... @@ -1,0 +1,1 @@
1 +20.4 KB
Content
qoQNWSBoEQ.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.joe
Size
... ... @@ -1,0 +1,1 @@
1 +98.4 KB
Content
xzZboZHffh.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.joe
Size
... ... @@ -1,0 +1,1 @@
1 +100.3 KB
Content