Changes for page Mitsubishi

Last modified by Joe on 2024/05/21 10:53

From version 83.14
edited by Joe
on 2024/03/13 19:54
Change comment: There is no comment for this version
To version 83.18
edited by Joe
on 2024/04/29 14:33
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -19,7 +19,7 @@
19 19  **Address List**
20 20  
21 21  |**Type**|**Device registers**|**Format**|**Range**|**Note**
22 -|(% rowspan="7" %)Bit|X|Xo|0~~303237|
22 +|(% rowspan="7" %)Bit|X|X o|0~~303237|
23 23  |Y|Y o|0~~303237|
24 24  |M|M d|0~~99999|
25 25  |T|T d|0~~99999|
... ... @@ -26,7 +26,7 @@
26 26  |C|C d|0~~99999|
27 27  |S|S d|0~~99999|
28 28  |SM|SM d|8000~~9999|
29 -|(% rowspan="8" %)Word|X|Xo|0~~303237|
29 +|(% rowspan="8" %)Word|X|X o|0~~303237|
30 30  |Y|Y o|0~~303237|
31 31  |M|M d|0~~99999|
32 32  |T|T d|0~~99999|
... ... @@ -160,7 +160,8 @@
160 160  
161 161  The Ethernet module IP is set to 192.168.39.254 in this document, and other options are default.
162 162  
163 -[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_dfbfdd586c855c47.png||alt="image-20221116105947-1.png" height="573" width="706"]]
163 +(% style="text-align:center" %)
164 +[[image:894qM2hnau.png]]
164 164  
165 165  Select "Open setting" to enter the setting interface, the settings are as follows.
166 166  
... ... @@ -176,10 +176,17 @@
176 176  
177 177  use the IP set in the "Ethernet board" to communicate directly with the network cable.
178 178  
179 -[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_d6fd9ce3b96f99e2.png||alt="image-20221116110832-2.png" height="423" width="708"]]
180 +(% style="text-align:center" %)
181 +[[image:xzZboZHffh.png]]
180 180  
181 -Read and write data from the Ethernet module
183 +(% style="text-align:center" %)
184 +[[image:ivWMdrv1Gh.png]]
182 182  
186 +(% style="text-align:center" %)
187 +[[image:qoQNWSBoEQ.png]]
188 +
189 +read and write data from the Ethernet module
190 +
183 183  [[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_690b3e57b29cfd4b.png||alt="image-20221116110907-3.png" height="549" width="706"]]
184 184  
185 185  Set "Transter setup" to COM communication, and read or write operation as shown below
... ... @@ -608,38 +608,37 @@
608 608  (% class="wikigeneratedid" %)
609 609  PC and PLC connection:
610 610  
611 -(% class="wikigeneratedid" %)
612 -Online→Read from PLC
619 +* Online→Read from PLC
613 613  
614 614  (% style="text-align:center" %)
615 615  [[image:1.png]]
616 616  
617 -choose PLC Series→OK
624 +* choose PLC Series→OK
618 618  
619 619  (% style="text-align:center" %)
620 620  [[image:StqCG53paq.png]]
621 621  
622 -serial USB→OK
629 +* serial USB→OK
623 623  
624 624  (% style="text-align:center" %)
625 625  [[image:Y7H80eq2Eb.png]]
626 626  
627 -Choose Parameter、Global Device Comment and Device Memory→Execute
634 +* Choose Parameter、Global Device Comment and Device Memory→Execute
628 628  
629 629  (% style="text-align:center" %)
630 630  [[image:6PAsdFz58I.png]]
631 631  
632 -OK→wait loading successfully→Close
639 +* OK→wait loading successfully→Close
633 633  
634 634  (% style="text-align:center" %)
635 635  [[image:0GBGUNn4hQ.png]]
636 636  
637 - Navigation→Parameter→PLC Parameter→IP Address Setting→Built-in Ethernet Port Setting→Host Station(Same as the port on  V-box)→End
644 +* Navigation→Parameter→PLC Parameter→IP Address Setting→Built-in Ethernet Port Setting→Host Station(Same as the port on  V-box)→End
638 638  
639 639  (% style="text-align:center" %)
640 640  [[image:Ypyl4SUHcf.png]]
641 641  
642 -Debug→Start/ Stop Simulation→wait loading successfully→Close
649 +* Debug→Start/ Stop Simulation→wait loading successfully→Close
643 643  
644 644  (% style="text-align:center" %)
645 645  [[image:ZmUzFbS39y.png]]
... ... @@ -647,4 +647,6 @@
647 647  (% style="text-align:center" %)
648 648  [[image:ehoO3C6bry.png]]
649 649  
650 -
657 +(% id="cke_bm_1296534S" style="display:none" %)** **(%%)**Cable Wiring**
658 +
659 +[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_2297240b57346b2a.png?width=401&height=170&rev=1.1||alt="12.可编程逻辑控制器Protocol_html_2297240b57346b2a.png" height="170" width="401"]]
894qM2hnau.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.joe
Size
... ... @@ -1,0 +1,1 @@
1 +20.4 KB
Content
qoQNWSBoEQ.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.joe
Size
... ... @@ -1,0 +1,1 @@
1 +98.4 KB
Content
xzZboZHffh.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.joe
Size
... ... @@ -1,0 +1,1 @@
1 +100.3 KB
Content