Changes for page Mitsubishi

Last modified by Joe on 2024/05/21 10:53

From version 83.14
edited by Joe
on 2024/03/13 19:54
Change comment: There is no comment for this version
To version 86.2
edited by Joe
on 2024/05/21 10:52
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -19,7 +19,7 @@
19 19  **Address List**
20 20  
21 21  |**Type**|**Device registers**|**Format**|**Range**|**Note**
22 -|(% rowspan="7" %)Bit|X|Xo|0~~303237|
22 +|(% rowspan="7" %)Bit|X|X o|0~~303237|
23 23  |Y|Y o|0~~303237|
24 24  |M|M d|0~~99999|
25 25  |T|T d|0~~99999|
... ... @@ -26,7 +26,7 @@
26 26  |C|C d|0~~99999|
27 27  |S|S d|0~~99999|
28 28  |SM|SM d|8000~~9999|
29 -|(% rowspan="8" %)Word|X|Xo|0~~303237|
29 +|(% rowspan="8" %)Word|X|X o|0~~303237|
30 30  |Y|Y o|0~~303237|
31 31  |M|M d|0~~99999|
32 32  |T|T d|0~~99999|
... ... @@ -159,8 +159,10 @@
159 159  Select "Operational setting" to enter the following screen.
160 160  
161 161  The Ethernet module IP is set to 192.168.39.254 in this document, and other options are default.
162 +
162 162  
163 -[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_dfbfdd586c855c47.png||alt="image-20221116105947-1.png" height="573" width="706"]]
164 +(% style="text-align:center" %)
165 +[[image:Inku25HyY8.png]]
164 164  
165 165  Select "Open setting" to enter the setting interface, the settings are as follows.
166 166  
... ... @@ -170,22 +170,26 @@
170 170  
171 171  [[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_7c01ac15090fcc5b.png||alt="image-20221116110802-1.png" height="549" width="706"]]
172 172  
175 +(% class="box infomessage" %)
176 +(((
177 +Note: If you can't communicate PLC to box normally, changing ''No confirm" to "confirm"
178 +)))
179 +
173 173  Click on "transter setup" - "PC side I/F setting", see the following figure.
174 174  
175 175  After setting, the first download must use the programming cable, as shown in the figure; after that, can
176 176  
177 177  use the IP set in the "Ethernet board" to communicate directly with the network cable.
185 +
178 178  
179 -[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_d6fd9ce3b96f99e2.png||alt="image-20221116110832-2.png" height="423" width="708"]]
187 +(% style="text-align:center" %)
188 +[[image:WstTyoGrxG.png]]
180 180  
181 -Read and write data from the Ethernet module
190 +(% style="text-align:center" %)
191 +[[image:aak9XC8xDH.png]]
182 182  
183 -[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_690b3e57b29cfd4b.png||alt="image-20221116110907-3.png" height="549" width="706"]]
184 184  
185 -Set "Transter setup" to COM communication, and read or write operation as shown below
186 186  
187 -[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_b317253742f7151.png||alt="image-20221116110917-4.png" height="549" width="706"]]
188 -
189 189  **PLC Settings (GX Works 2)**
190 190  
191 191  Create a blank FX5U project
... ... @@ -608,38 +608,37 @@
608 608  (% class="wikigeneratedid" %)
609 609  PC and PLC connection:
610 610  
611 -(% class="wikigeneratedid" %)
612 -Online→Read from PLC
617 +* Online→Read from PLC
613 613  
614 614  (% style="text-align:center" %)
615 615  [[image:1.png]]
616 616  
617 -choose PLC Series→OK
622 +* choose PLC Series→OK
618 618  
619 619  (% style="text-align:center" %)
620 620  [[image:StqCG53paq.png]]
621 621  
622 -serial USB→OK
627 +* serial USB→OK
623 623  
624 624  (% style="text-align:center" %)
625 625  [[image:Y7H80eq2Eb.png]]
626 626  
627 -Choose Parameter、Global Device Comment and Device Memory→Execute
632 +* Choose Parameter、Global Device Comment and Device Memory→Execute
628 628  
629 629  (% style="text-align:center" %)
630 630  [[image:6PAsdFz58I.png]]
631 631  
632 -OK→wait loading successfully→Close
637 +* OK→wait loading successfully→Close
633 633  
634 634  (% style="text-align:center" %)
635 635  [[image:0GBGUNn4hQ.png]]
636 636  
637 - Navigation→Parameter→PLC Parameter→IP Address Setting→Built-in Ethernet Port Setting→Host Station(Same as the port on  V-box)→End
642 +* Navigation→Parameter→PLC Parameter→IP Address Setting→Built-in Ethernet Port Setting→Host Station(Same as the port on  V-box)→End
638 638  
639 639  (% style="text-align:center" %)
640 640  [[image:Ypyl4SUHcf.png]]
641 641  
642 -Debug→Start/ Stop Simulation→wait loading successfully→Close
647 +* Debug→Start/ Stop Simulation→wait loading successfully→Close
643 643  
644 644  (% style="text-align:center" %)
645 645  [[image:ZmUzFbS39y.png]]
... ... @@ -647,4 +647,6 @@
647 647  (% style="text-align:center" %)
648 648  [[image:ehoO3C6bry.png]]
649 649  
650 -
655 +(% id="cke_bm_1296534S" style="display:none" %)** **(%%)**Cable Wiring**
656 +
657 +[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_2297240b57346b2a.png?width=401&height=170&rev=1.1||alt="12.可编程逻辑控制器Protocol_html_2297240b57346b2a.png" height="170" width="401"]]
894qM2hnau.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.joe
Size
... ... @@ -1,0 +1,1 @@
1 +20.4 KB
Content
Inku25HyY8.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.joe
Size
... ... @@ -1,0 +1,1 @@
1 +19.6 KB
Content
WstTyoGrxG.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.joe
Size
... ... @@ -1,0 +1,1 @@
1 +99.1 KB
Content
aak9XC8xDH.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.joe
Size
... ... @@ -1,0 +1,1 @@
1 +48.4 KB
Content
aoZAhFYHA4.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.joe
Size
... ... @@ -1,0 +1,1 @@
1 +20.4 KB
Content
qoQNWSBoEQ.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.joe
Size
... ... @@ -1,0 +1,1 @@
1 +98.4 KB
Content
xzZboZHffh.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.joe
Size
... ... @@ -1,0 +1,1 @@
1 +100.3 KB
Content