Changes for page Mitsubishi
Last modified by Joe on 2024/05/21 10:53
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 7 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -19,7 +19,7 @@ 19 19 **Address List** 20 20 21 21 |**Type**|**Device registers**|**Format**|**Range**|**Note** 22 -|(% rowspan="7" %)Bit|X|Xo|0~~303237| 22 +|(% rowspan="7" %)Bit|X|X o|0~~303237| 23 23 |Y|Y o|0~~303237| 24 24 |M|M d|0~~99999| 25 25 |T|T d|0~~99999| ... ... @@ -26,7 +26,7 @@ 26 26 |C|C d|0~~99999| 27 27 |S|S d|0~~99999| 28 28 |SM|SM d|8000~~9999| 29 -|(% rowspan="8" %)Word|X|Xo|0~~303237| 29 +|(% rowspan="8" %)Word|X|X o|0~~303237| 30 30 |Y|Y o|0~~303237| 31 31 |M|M d|0~~99999| 32 32 |T|T d|0~~99999| ... ... @@ -159,8 +159,10 @@ 159 159 Select "Operational setting" to enter the following screen. 160 160 161 161 The Ethernet module IP is set to 192.168.39.254 in this document, and other options are default. 162 + 162 162 163 -[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_dfbfdd586c855c47.png||alt="image-20221116105947-1.png" height="573" width="706"]] 164 +(% style="text-align:center" %) 165 +[[image:Inku25HyY8.png]] 164 164 165 165 Select "Open setting" to enter the setting interface, the settings are as follows. 166 166 ... ... @@ -170,22 +170,26 @@ 170 170 171 171 [[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_7c01ac15090fcc5b.png||alt="image-20221116110802-1.png" height="549" width="706"]] 172 172 175 +(% class="box infomessage" %) 176 +((( 177 +Note: If you can't communicate PLC to box normally, changing ''No confirm" to "confirm" 178 +))) 179 + 173 173 Click on "transter setup" - "PC side I/F setting", see the following figure. 174 174 175 175 After setting, the first download must use the programming cable, as shown in the figure; after that, can 176 176 177 177 use the IP set in the "Ethernet board" to communicate directly with the network cable. 185 + 178 178 179 -[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_d6fd9ce3b96f99e2.png||alt="image-20221116110832-2.png" height="423" width="708"]] 187 +(% style="text-align:center" %) 188 +[[image:WstTyoGrxG.png]] 180 180 181 -Read and write data from the Ethernet module 190 +(% style="text-align:center" %) 191 +[[image:aak9XC8xDH.png]] 182 182 183 -[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_690b3e57b29cfd4b.png||alt="image-20221116110907-3.png" height="549" width="706"]] 184 184 185 -Set "Transter setup" to COM communication, and read or write operation as shown below 186 186 187 -[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_b317253742f7151.png||alt="image-20221116110917-4.png" height="549" width="706"]] 188 - 189 189 **PLC Settings (GX Works 2)** 190 190 191 191 Create a blank FX5U project
- 894qM2hnau.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.joe - Size
-
... ... @@ -1,0 +1,1 @@ 1 +20.4 KB - Content
- Inku25HyY8.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.joe - Size
-
... ... @@ -1,0 +1,1 @@ 1 +19.6 KB - Content
- WstTyoGrxG.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.joe - Size
-
... ... @@ -1,0 +1,1 @@ 1 +99.1 KB - Content
- aak9XC8xDH.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.joe - Size
-
... ... @@ -1,0 +1,1 @@ 1 +48.4 KB - Content
- aoZAhFYHA4.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.joe - Size
-
... ... @@ -1,0 +1,1 @@ 1 +20.4 KB - Content
- qoQNWSBoEQ.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.joe - Size
-
... ... @@ -1,0 +1,1 @@ 1 +98.4 KB - Content
- xzZboZHffh.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.joe - Size
-
... ... @@ -1,0 +1,1 @@ 1 +100.3 KB - Content