... ... @@ -19,7 +19,7 @@
19 19  **Address List**
20 20  
21 21  |**Type**|**Device registers**|**Format**|**Range**|**Note**
22 -|(% rowspan="7" %)Bit|X|X o|0~~303237|
22 +|(% rowspan="7" %)Bit|X|Xo|0~~303237|
23 23  |Y|Y o|0~~303237|
24 24  |M|M d|0~~99999|
25 25  |T|T d|0~~99999|
... ... @@ -26,7 +26,7 @@
26 26  |C|C d|0~~99999|
27 27  |S|S d|0~~99999|
28 28  |SM|SM d|8000~~9999|
29 -|(% rowspan="8" %)Word|X|X o|0~~303237|
29 +|(% rowspan="8" %)Word|X|Xo|0~~303237|
30 30  |Y|Y o|0~~303237|
31 31  |M|M d|0~~99999|
32 32  |T|T d|0~~99999|
... ... @@ -160,8 +160,7 @@
160 160  
161 161  The Ethernet module IP is set to 192.168.39.254 in this document, and other options are default.
162 162  
163 -(% style="text-align:center" %)
164 -[[image:894qM2hnau.png]]
163 +[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_dfbfdd586c855c47.png||alt="image-20221116105947-1.png" height="573" width="706"]]
165 165  
166 166  Select "Open setting" to enter the setting interface, the settings are as follows.
167 167  
... ... @@ -171,11 +171,6 @@
171 171  
172 172  [[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_7c01ac15090fcc5b.png||alt="image-20221116110802-1.png" height="549" width="706"]]
173 173  
174 -(% class="box infomessage" %)
175 -(((
176 -Note: If you can't communicate PLC to box normally, changing ''No confirm" to "confirm"
177 -)))
178 -
179 179  Click on "transter setup" - "PC side I/F setting", see the following figure.
180 180  
181 181  After setting, the first download must use the programming cable, as shown in the figure; after that, can
... ... @@ -182,16 +182,16 @@
182 182  
183 183  use the IP set in the "Ethernet board" to communicate directly with the network cable.
184 184  
185 -(% style="text-align:center" %)
186 -[[image:xzZboZHffh.png]]
179 +[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_d6fd9ce3b96f99e2.png||alt="image-20221116110832-2.png" height="423" width="708"]]
187 187  
188 -(% style="text-align:center" %)
189 -[[image:ivWMdrv1Gh.png]]
181 +Read and write data from the Ethernet module
190 190  
191 -(% style="text-align:center" %)
192 -[[image:qoQNWSBoEQ.png]]
183 +[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_690b3e57b29cfd4b.png||alt="image-20221116110907-3.png" height="549" width="706"]]
193 193  
185 +Set "Transter setup" to COM communication, and read or write operation as shown below
194 194  
187 +[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_b317253742f7151.png||alt="image-20221116110917-4.png" height="549" width="706"]]
188 +
195 195  **PLC Settings (GX Works 2)**
196 196  
197 197  Create a blank FX5U project
894qM2hnau.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.joe
Size
... ... @@ -1,1 +1,0 @@
1 -20.4 KB
Content
qoQNWSBoEQ.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.joe
Size
... ... @@ -1,1 +1,0 @@
1 -98.4 KB
Content
xzZboZHffh.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.joe
Size
... ... @@ -1,1 +1,0 @@
1 -100.3 KB
Content