2
3 == {{id name="HFX1SFF0C1NFF0C2NSerial"/}}**FX1S,1N,2N Serial ** ==
4
5 Supported Series: Mitsubishi FX1S, FX1N, FX2N series
6
7 **1)V-BOX Settings**
8
9 |**Item**|**Settings**|**Note**
10 |Protocol|Mitsubishi FX1S/FX1N/FX2N|
11 |Connection|RS422/RS485/RS232|
12 |Baud rate|9600~~115200|
13 |Data bit|7/8|
14 |Parity|EVEN/Odd/None|
15 |Stop bit|1/2|
16 |PLC station No.|1~~255|
17
18 **2)Address List**
19
20 |**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note**
21 |(% rowspan="7" %)Bit|X|X|Xo|0~~303237|
22 |Y|Y|Y o|0~~303237|
23 |M|M|M d|0~~99999|
24 |T|T|T d|0~~99999|
25 |C|C|C d|0~~99999|
26 |S|S|S d|0~~99999|
27 |SM|SM|SM d|8000~~9999|
28 |(% rowspan="8" %)Word|X|X|Xo|0~~303237|
29 |Y|Y|Y o|0~~303237|
30 |M|M|M d|0~~99999|
31 |T|T|T d|0~~99999|
32 |C|C|C d|0~~199|
33 |D|D|D d|0~~7999|
34 |S|S|S d|0~~99999|
35 |SD|SD|SD d|8000~~9999|
36
37 **3)Configure the communication protocol**
38
39 {{id name="Iimage-20220825102844-3.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_dc262f14b14cf564.png||alt="image-20220825102844-3.png" height="1011" width="1920"]]
40
41 **4)Cable Wiring**
42
43 * **RS422**
44
45 {{id name="Iimage-20220825103350-4.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_9294a40c62eb99be.png||alt="image-20220825103350-4.png" height="284" width="723"]]
46
47 {{id name="Iimage-20220825100845-4.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_860bcf87f6ca7b98.png||alt="image-20220825100845-4.png" height="246" width="419"]]
48
49 == {{id name="HFX3UFF0C3GFF0C3GASerial"/}}**FX3U,3G,3GA Serial ** ==
50
51 Supported Series: Mitsubishi FX3U, FX3G, FX3GA series
52
53 **1)V-BOX Settings**
54
55 |**Item**|**Settings**|**Note**
56 |Protocol|Mitsubishi FX3U/3G/3GA|
57 |Connection|RS422/RS485/RS232|
58 |Baud rate|9600~~115200|
59 |Data bit|7/8|
60 |Parity|EVEN/Odd/None|
61 |Stop bit|1/2|
62 |PLC station No.|1~~255|
63
64 **2)Address List**
65
66 |**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note**
67 |(% rowspan="7" %)Bit|X|X|Xo|0~~303237|
68 |Y|Y|Y o|0~~303237|
69 |M|M|M d|0~~99999|
70 |T|T|T d|0~~99999|
71 |C|C|C d|0~~99999|
72 |S|S|S d|0~~99999|
73 |SM|SM|SM d|8000~~9999|
74 |(% rowspan="8" %)Word|X|X|Xo|0~~303237|
75 |Y|Y|Y o|0~~303237|
76 |M|M|M d|0~~99999|
77 |T|T|T d|0~~99999|
78 |C|C|C d|0~~199|
79 |D|D|D d|0~~7999|
80 |S|S|S d|0~~99999|
81 |SD|SD|SD d|8000~~9999|
82
83 **3)Configure the communication protocol**
84
85 {{id name="Iimage-20220825102649-2.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_4d2a4921240d23c6.png||alt="image-20220825102649-2.png" height="1009" width="1920"]]
86
87 **4)Cable Wiring**
88
89 * **RS422**
90
91 {{id name="Iimage-20220825103421-5.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_1e904556bb758dfe.png||alt="image-20220825103421-5.png" height="296" width="715"]]
92
93 {{id name="Iimage-20220825100845-4.png-1"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_860bcf87f6ca7b98.png||alt="image-20220825100845-4.png" height="246" width="419"]]
94
95 == {{id name="HFX3UEthernet"/}}**FX3U Ethernet ** ==
96
97 Supported Modules: FX3U-ENET-ADP, FX3U-ENET-L
98
99 **1)V-BOX Settings**
100
101 |Items|Settings|Note
102 |Protocol|Mitsubishi FX3U|
103 |Connection|Ethernet|
104 |Port No.|5009|Must be the same as the PLC setting
105 |PLC station No.|0|
106
107 **2)Address List**
108
109 |**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note**
110 |(% rowspan="7" %)Bit|X|X|X OOO|0~~377|
111 |Y|Y|Y OOO|0~~377|
112 |M|M|M DDDD|0~~7679|
113 |SM|SM|SM DDDD|8000~~8511|
114 |S|S|S DDDD|0~~4095|
115 |TS|TS|TS DDD|0~~511|
116 |CS|CS|CS DDD|0~~255|
117 |(% rowspan="5" %)Word|CN|CN|CN DDD|0~~199|
118 |TN|TN|TN DDD|0~~511|
119 |D|D|D DDDD|0~~7999|
120 |SD|SD|SD DDDD|8000~~8511|
121 |R|R|R DDDDD|0~~32767|
122
123 **3)Ethernet Module Settings**
124
125 FX3U-ENET-L module configuration
126 Set up the FX3U-ENET-L Ethernet module settings as follows.
127 Select the module location, which in this document is Module 0.
128
129 {{id name="Iimage-20221116105850-1.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_949d5d77c1d9cf1e.png||alt="image-20221116105850-1.png" height="573" width="706"]]
130
131 Select "Operational setting" to enter the following screen.
132
133 The Ethernet module IP is set to 192.168.39.254 in this document, and other options are default.
134
135 {{id name="Iimage-20221116105947-1.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_dfbfdd586c855c47.png||alt="image-20221116105947-1.png" height="573" width="706"]]
136
137 Select "Open setting" to enter the setting interface, the settings are as follows.
138
139 The third item "Protocol" selects TCP, and "Open system" selects MELSOFT connection, which allows the
140
141 Mitsubishi programming software GX works2 to communicate with the FX3U via the Ethernet module.
142
143 {{id name="Iimage-20221116110802-1.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_7c01ac15090fcc5b.png||alt="image-20221116110802-1.png" height="549" width="706"]]
144
145 Click on "transter setup" - "PC side I/F setting", see the following figure.
146
147 After setting, the first download must use the programming cable, as shown in the figure; after that, can
148
149 use the IP set in the "Ethernet board" to communicate directly with the network cable.
150
151 {{id name="Iimage-20221116110832-2.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_d6fd9ce3b96f99e2.png||alt="image-20221116110832-2.png" height="423" width="708"]]
152
153 Read and write data from the Ethernet module
154
155 {{id name="Iimage-20221116110907-3.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_690b3e57b29cfd4b.png||alt="image-20221116110907-3.png" height="549" width="706"]]
156
157 Set "Transter setup" to COM communication, and read or write operation as shown below
158
159 {{id name="Iimage-20221116110917-4.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_b317253742f7151.png||alt="image-20221116110917-4.png" height="549" width="706"]]
160
161 **4)PLC Settings (GX Works 2)**
162
163 Create a blank FX5U project
164
165 Find Current Connection in the navigation
166
167 {{id name="Iimage-20221116111427-1.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_d2a46ba9c005cf38.png||alt="image-20221116111427-1.png" height="421" width="705"]]
168
169 Select Connection Channel List
170
171 Select Ethernet board communication
172
173 {{id name="Iimage-20221116111451-2.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_8f49721a3e5b0ef9.png||alt="image-20221116111451-2.png" height="421" width="705"]]
174
175 Select Ethernet Module
176 Set the IP address of the PLC
177
178 {{id name="Iimage-20221116111509-3.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_1e9a9e29a46a1041.png||alt="image-20221116111509-3.png" height="666" width="699"]]
179
180 Read or write PLC data, in this document is read
181
182 {{id name="Iimage-20221116111651-4.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_e3d629103727a423.png||alt="image-20221116111651-4.png" height="416" width="697"]]
183
184 {{id name="Iimage-20221116111727-5.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_7f29923ebcb670d1.png||alt="image-20221116111727-5.png" height="416" width="697"]]
185
186 **4)Configure the communication protocol**
187
188 {{id name="Iimage-20221119101946-2.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_b2cdc33b6eb92b67.png||alt="image-20221119101946-2.png" height="395" width="695"]]
189
190 == {{id name="HFX5USerial"/}}**FX5U Serial ** ==
191
192 Mitsubishi FX5U series PLC
193
194 **1)V-BOX Settings**
195
196 |**Item**|**Settings**|**Note**
197 |Protocol|Mitsubishi FX5U|
198 |Connection|RS422/RS485|
199 |Baud rate|9600|
200 |Data bit|7|
201 |Parity|Odd|
202 |Stop bit|1|
203 |PLC station No.|1~~255|Need to be the same as PLC settings
204
205 **2)Address List**
206
207 |**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note**
208 |(% rowspan="15" %)Bit|X|X|X o|0~~303237|
209 |Y|Y|Y o|0~~303237|
210 |M|M|M d|0~~99999|
211 |B|B|B h|0~~7FFF|
212 |F|F|F d|0~~32767|
213 |SB|SB|SB h|0~~7FFF|
214 |TS|TS|TS d|0~~1023|
215 |TC|TC|TC d|0~~1023|
216 |STS|STS|STS d|0~~1023|
217 |STC|STC|STS d|0~~1023|
218 |CS|CS|CS d|0~~1023|
219 |CC|CC|CC d|0~~1023|
220 |SM|SM|SM d|0~~9999|
221 |L|L|L d|0~~32767|
222 |S|S|S d|0~~4095|
223 |(% rowspan="9" %)Word|W|W|W h|0~~3FF|
224 |TN|TN|TN d|0~~1023|
225 |STN|STN|STN d|0~~1023|
226 |CN|CN|CN d|0~~1023|
227 |R|R|R d|0~~32767|
228 |SW|SW|SW h|0~~7FFF|
229 |Z|Z|Z d|0~~23|
230 |D|D|D d|0~~7999|
231 |SD|SD|SD d|0~~11999|
232
233 **3)PLC Settings (GX Works 3)**
234
235 Create a blank FX5U project
236
237 Find the 485 serial port module in the system navigation bar and double click to enter the settings.
238
239 {{id name="Ihttps:2F2Fdocs.we-con.com.cn2Fbin2Fdownload2FPIStudio2F12.PLC2520protocols2FWebHome2F12.PLC2520Protocol_html_5c9cb13fac1e6c93.png3Fwidth3D20026height3D46226rev3D1.1"/}}[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_5c9cb13fac1e6c93.png?width=200&height=462&rev=1.1||alt="12.PLC Protocol_html_5c9cb13fac1e6c93.png" height="462" width="200"]]
240
241 Select protocol in the setting item, and set parameters.
242
243 {{id name="Ihttps:2F2Fdocs.we-con.com.cn2Fbin2Fdownload2FPIStudio2F12.PLC2520protocols2FWebHome2F12.PLC2520Protocol_html_de942589ca070228.png3Fwidth3D60026height3D32426rev3D1.1"/}}[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_de942589ca070228.png?width=600&height=324&rev=1.1||alt="12.PLC Protocol_html_de942589ca070228.png" height="324" width="600"]]
244
245 Set station number, and [Message Pattern] (Pattern 1 or Pattern 4)
246
247 {{id name="Ihttps:2F2Fdocs.we-con.com.cn2Fbin2Fdownload2FPIStudio2F12.PLC2520protocols2FWebHome2F12.PLC2520Protocol_html_387ec7d00b5feb59.png3Fwidth3D60026height3D32326rev3D1.1"/}}[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_387ec7d00b5feb59.png?width=600&height=323&rev=1.1||alt="12.PLC Protocol_html_387ec7d00b5feb59.png" height="323" width="600"]]
248
249 Click the [Apply] button to finish the setting.
250
251 Click download and select the items as below, then click [execute] to download the configuration to PLC.
252
253 {{id name="Ihttps:2F2Fdocs.we-con.com.cn2Fbin2Fdownload2FPIStudio2F12.PLC2520protocols2FWebHome2F12.PLC2520Protocol_html_cdef1c5ec8cc2105.png3Fwidth3D60026height3D43426rev3D1.1"/}}[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_cdef1c5ec8cc2105.png?width=600&height=434&rev=1.1||alt="12.PLC Protocol_html_cdef1c5ec8cc2105.png" height="434" width="600"]]
254
255 As soon as download is completed, connect PLC with serial port, then configure it in the [Specify Connection Destination Connection].
256
257 Done.
258
259 **4)Configure the communication protocol**
260
261 {{id name="Iimage-20220825104904-1.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_dbaddd53e9951a17.png||alt="image-20220825104904-1.png" height="1033" width="1920"]]
262
263 **5)Cable Wiring**
264
265 * **RS422**
266
267 {{id name="Iimage-20220825105105-2.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_d022c5ff4cf8c68e.png||alt="image-20220825105105-2.png" height="288" width="711"]]
268
269 {{id name="Iimage-20220825105533-3.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_50e173394c73f154.png||alt="image-20220825105533-3.png" height="246" width="420"]]
270
271 == {{id name="HFX5UEthernet"/}}**FX5U Ethernet ** ==
272
273 Mitsubishi FX5U series PLC
274
275 **1)V-BOX Settings**
276
277 |**Items**|**Settings**|**Note**
278 |Protocol|Mitsubishi FX5U|
279 |Connection|Ethernet|
280 |Port No.|5002|Must be the same as the PLC setting
281 |PLC station No.|0|
282
283 **2)Address List**
284
285 |**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note**
286 |(% rowspan="15" %)Bit|X|X|X o|0~~303237|
287 |Y|Y|Y o|0~~303237|
288 |M|M|M d|0~~99999|
289 |B|B|B h|0~~7FFF|
290 |F|F|F d|0~~32767|
291 |SB|SB|SB h|0~~7FFF|
292 |TS|TS|TS d|0~~1023|
293 |TC|TC|TC d|0~~1023|
294 |STS|STS|STS d|0~~1023|
295 |STC|STC|STS d|0~~1023|
296 |CS|CS|CS d|0~~1023|
297 |CC|CC|CC d|0~~1023|
298 |SM|SM|SM d|0~~9999|
299 |L|L|L d|0~~32767|
300 |S|S|S d|0~~4095|
301 |(% rowspan="9" %)Word|W|W|W h|0~~3FF|
302 |TN|TN|TN d|0~~1023|
303 |STN|STN|STN d|0~~1023|
304 |CN|CN|CN d|0~~1023|
305 |R|R|R d|0~~32767|
306 |SW|SW|SW h|0~~7FFF|
307 |Z|Z|Z d|0~~23|
308 |D|D|D d|0~~7999|
309 |SD|SD|SD d|0~~11999|
310
311 **3)PLC Settings (GX Works 3)**
312
313 Find the [Ethernet port] in the navigation area.
314
315 {{id name="Ihttps:2F2Fdocs.we-con.com.cn2Fbin2Fdownload2FPIStudio2F12.PLC2520protocols2FWebHome2F12.PLC2520Protocol_html_8e8f85ace087346c.png3Fwidth3D30026height3D59326rev3D1.1"/}}[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_8e8f85ace087346c.png?width=300&height=593&rev=1.1||alt="12.PLC Protocol_html_8e8f85ace087346c.png" height="593" width="300"]]
316
317 Select [Own Node Settings] in the [Setting Item List];
318
319 Set [IP Address], [Subnet Mask], [Default Gateway];
320
321 Click [Detailed Settings] into [Ethernet Configuration (Built-in Ethernet Port)] windows;
322
323 {{id name="Ihttps:2F2Fdocs.we-con.com.cn2Fbin2Fdownload2FPIStudio2F12.PLC2520protocols2FWebHome2F12.PLC2520Protocol_html_5d98495052c8c10e.png3Fwidth3D60026height3D33926rev3D1.1"/}}[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_5d98495052c8c10e.png?width=600&height=339&rev=1.1||alt="12.PLC Protocol_html_5d98495052c8c10e.png" height="339" width="600"]]
324
325 Select [SLMP Connection Module] and add into host station as below picture shows;
326
327 Set Port number as 5002 (this is necessary settings);
328
329 Click [Close with Reflecting the Setting] to save and close window;
330
331 {{id name="Ihttps:2F2Fdocs.we-con.com.cn2Fbin2Fdownload2FPIStudio2F12.PLC2520protocols2FWebHome2F12.PLC2520Protocol_html_14b489fdc6c6589d.png3Fwidth3D60026height3D35026rev3D1.1"/}}[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_14b489fdc6c6589d.png?width=600&height=350&rev=1.1||alt="12.PLC Protocol_html_14b489fdc6c6589d.png" height="350" width="600"]]
332
333 Click [Apply] to completed Etherenet settings;
334
335 Switch to the [On line data operation] interface as below, check the item and click [Execute] to download.
336
337 {{id name="Ihttps:2F2Fdocs.we-con.com.cn2Fbin2Fdownload2FPIStudio2F12.PLC2520protocols2FWebHome2F12.PLC2520Protocol_html_c93025a968a8a9e7.png3Fwidth3D60026height3D43426rev3D1.1"/}}[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_c93025a968a8a9e7.png?width=600&height=434&rev=1.1||alt="12.PLC Protocol_html_c93025a968a8a9e7.png" height="434" width="600"]]
338
339 **4)Configure the communication protocol**
340
341 {{id name="Iimage-20220825112403-1.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_caa9bf4d8cc6de0f.png||alt="图片-20220825112403-1.png" height="1033" width="1920"]]
342
343 **5)Cable Wiring**
344
345 {{id name="Ihttps:2F2Fdocs.we-con.com.cn2Fbin2Fdownload2FPIStudio2F12.PLC2520protocols2FWebHome2F12.PLC2520Protocol_html_2297240b57346b2a.png3Fwidth3D40126height3D17026rev3D1.1"/}}[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_2297240b57346b2a.png?width=401&height=170&rev=1.1||alt="12.可编程逻辑控制器Protocol_html_2297240b57346b2a.png" height="170" width="401"]]
346
347 == {{id name="HL02Serial"/}}**L02 Serial ** ==
348
349 Mitsubishi L02 series CPU built-in serial port.
350
351 **1)V-BOX Settings**
352
353 |**Item**|**Settings**|**Note**
354 |Protocol|Mitsubishi L02|
355 |Connection|RS422|
356 |Baud rate|115200|
357 |Data bit|8|
358 |Parity|Odd|
359 |Stop bit|1|
360 |PLC station No.|1~~255|Need to be the same as PLC settings
361
362 **2)Address List**
363
364 |**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note**
365 |Bit|X|X|X h|0~~FFFF|
366 |Bit|Y|Y|Y h|0~~FFFF|
367 |Bit|M|M|M d|0~~9999|
368 |Bit|L|L|L d|0~~9999|
369 |Bit|F|F|F d|0~~9999|
370 |Bit|B|B|B h|0~~FFFF|
371 |Bit|V|V|V d|0~~2047|
372 |Bit|TC|TC|TC d|0~~9999|
373 |Bit|SS|SS|SS d|0~~9999|
374 |Bit|SC|SC|SC d|0~~9999|
375 |Bit|CS|CS|CS d|0~~9999|
376 |Bit|CC|CC|CC d|0~~9999|
377 |Bit|SB|SB|SB h|0~~FFFF|
378 |Bit|SM|SM|SM d|0~~2047|
379 |Bit|STS|STS|STS d|0~~1023|
380 |Bit|S|S|S d|0~~9999|
381 |Bit|DX|DX|DX h|0~~FFFF|
382 |Bit|DY|DY|DY h|0~~FFFF|
383 |Bit|TS|TS|TS d|0~~9999|
384 |Bit|Dbit|Dbit|Dbit d.d|0~~99999.0~~15|
385 |Word|W|W|W h|0~~FFFF|
386 |Word|TN|TN|TN d|0~~99999|
387 |Word|SN|SN|SN d|0~~99999|
388 |Word|CN|CN|CN d|0~~99999|
389 |Word|R|R|R d|0~~99999|
390 |Word|SW|SW|SW h|0~~FFFF|
391 |Word|Z|Z|Z d|0~~99999|
392 |Word|ZR|ZR|ZR h|0~~FFFF|
393 |Word|D|D|D d|0~~99999|
394
395 **3)Communication Settings**
396
397 {{id name="Iimage-20220825160648-3.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_cfed67f2ecb4ccec.png||alt="image-20220825160648-3.png" height="1009" width="1920"]]
398
399 **4)Cable Wiring**
400
401 * **RS422**
402
403 {{id name="Iimage-20220825161612-8.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_90e38f152d639809.png||alt="image-20220825161612-8.png" height="278" width="612"]]
404
405 {{id name="Iimage-20220825160820-4.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_d301e675d8224725.png||alt="image-20220825160820-4.png" height="208" width="359"]]
406
407 == {{id name="HL02Ethernet"/}}**L02 Ethernet ** ==
408
409 Mitsubishi L series CPU built-in Ethernet port.
410
411 **1)V-BOX Settings**
412
413 |**Items**|**Settings**|**Note**
414 |Protocol|MIT L02 CPU MELSEC|
415 |Connection|Ethernet|
416 |Port No.|1025|Must be the same as the PLC setting
417 |PLC station No.|0|Must be the same as the PLC setting
418
419 **2)Address List**
420
421 |**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note**
422 |Bit|X|X|X h|0~~FFFF|
423 |Bit|Y|Y|Y h|0~~FFFF|
424 |Bit|M|M|M d|0~~9999|
425 |Bit|L|L|L d|0~~9999|
426 |Bit|F|F|F d|0~~9999|
427 |Bit|B|B|B h|0~~FFFF|
428 |Bit|V|V|V d|0~~2047|
429 |Bit|TC|TC|TC d|0~~9999|
430 |Bit|SS|SS|SS d|0~~9999|
431 |Bit|SC|SC|SC d|0~~9999|
432 |Bit|CS|CS|CS d|0~~9999|
433 |Bit|CC|CC|CC d|0~~9999|
434 |Bit|SB|SB|SB h|0~~FFFF|
435 |Bit|SM|SM|SM d|0~~2047|
436 |Bit|STS|STS|STS d|0~~1023|
437 |Bit|S|S|S d|0~~9999|
438 |Bit|DX|DX|DX h|0~~FFFF|
439 |Bit|DY|DY|DY h|0~~FFFF|
440 |Bit|TS|TS|TS d|0~~9999|
441 |Bit|Dbit|Dbit|Dbit d.d|0~~99999.0~~15|
442 |Word|W|W|W h|0~~FFFF|
443 |Word|TN|TN|TN d|0~~99999|
444 |Word|SN|SN|SN d|0~~99999|
445 |Word|CN|CN|CN d|0~~99999|
446 |Word|R|R|R d|0~~99999|
447 |Word|SW|SW|SW h|0~~FFFF|
448 |Word|Z|Z|Z d|0~~99999|
449 |Word|ZR|ZR|ZR h|0~~FFFF|
450 |Word|D|D|D d|0~~99999|
451
452 **3)PLC Settings (GX Works2 )**
453
454 Create a project
455
456 Set PLC IP, subnet mask and gateway;
457
458 Select [Binary Code] as communication data code;
459
460 {{id name="Ihttps:2F2Fdocs.we-con.com.cn2Fbin2Fdownload2FPIStudio2F12.PLC2520protocols2FWebHome2F12.PLC2520Protocol_html_776e17505f3fc6c0.png3Fwidth3D60026height3D52426rev3D1.1"/}}[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_776e17505f3fc6c0.png?width=600&height=524&rev=1.1||alt="12.PLC Protocol_html_776e17505f3fc6c0.png" height="524" width="600"]]
461
462 Set PLC port number, for example 1025
463
464 {{id name="Ihttps:2F2Fdocs.we-con.com.cn2Fbin2Fdownload2FPIStudio2F12.PLC2520protocols2FWebHome2F12.PLC2520Protocol_html_8d0d1a22d388f70b.png3Fwidth3D60026height3D52426rev3D1.1"/}}[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_8d0d1a22d388f70b.png?width=600&height=524&rev=1.1||alt="12.PLC Protocol_html_8d0d1a22d388f70b.png" height="524" width="600"]]
465
466 Save settings;
467
468 Download project into PLC device;
469
470 Restart PLC device;
471
472 **4)Configure the communication protocol**
473
474 {{id name="Iimage-20220825142659-1.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_fafc9b29e20178c0.png||alt="image-20220825142659-1.png" height="1010" width="1920"]]
475
476 **5)Cable Wiring**
477
478 {{id name="Ihttps:2F2Fdocs.we-con.com.cn2Fbin2Fdownload2FPIStudio2F12.PLC2520protocols2FWebHome2F12.PLC2520Protocol_html_2297240b57346b2a.png3Fwidth3D40126height3D17026rev3D1.1-1"/}}[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_2297240b57346b2a.png?width=401&height=170&rev=1.1||alt="12.PLC Protocol_html_2297240b57346b2a.png" height="170" width="401"]]
479
480 == {{id name="HQ12HSerial"/}}**Q12H Serial ** ==
481
482 This Demo shows V-BOX communicate with Q12H PLC by Q02H serial Protocol
483
484 **[[Download link>>url:https://ftp.we-con.com.cn/Download/WIKI/PI%20HMI/Demo/Communication/V-Box%20connect%20PLC%20Q12H.rar]]**
485
486 == {{id name="HQJ71E71Ethernet"/}}**QJ71E71 Ethernet ** ==
487
488 Mitsubishi QJ71E71 Ethernet communication module;
489
490 **1)V-BOX Settings**
491
492 |**Items**|**Settings**|**Note**
493 |Protocol|MIT QJ71E71 MELSEC|
494 |Connection|Ethernet|
495 |Port No.|1025|Must be the same as the PLC setting
496 |PLC station No.|0|Must be the same as the PLC setting
497
498 **2)Address List**
499
500 |**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note**
501 |(% rowspan="18" %)Bit|X|X|X h|0~~1FFF|
502 |Y|Y|Y h|0~~1FFF|
503 |M|M|M d|0~~99999|
504 |L|L|L d|0~~8191|
505 |F|F|F d|0~~2047|
506 |B|B|B h|0~~1FFF|
507 |V|V|V d|0~~2047|
508 |TS|TS|TS d|0~~2047|
509 |TC|TC|TC d|0~~2047|
510 |SS|SS|SS d|0~~2047|
511 |SC|SC|SC d|0~~2047|
512 |CS|CS|CS d|0~~1023|
513 |CC|CC|CC d|0~~1023|
514 |SB|SB|SB h|0~~7FF|
515 |S|S|S d|0~~8191|
516 |DX|DX|DX h|0~~1FFF|
517 |DY|DY|DY h|0~~1FFF|
518 |SM|SM|SM d|8000~~9999|
519 |(% rowspan="10" %)Word|SD|SD|SD d|0~~2047|
520 |D|D|D d|0~~12287|
521 |W|W|W h|0~~1FFF|
522 |TN|TN|TN d|0~~2047|
523 |SN|SN|SN d|0~~2047|
524 |CN|CN|CN d|0~~1023|
525 |R|R|R d|0~~32767|
526 |SW|SW|SW h|0~~7FF|
527 |Z|Z|Z d|0~~15|
528 |ZR|ZR|ZR h|0~~FE7FF|
529
530 **3)PLC Settings(GX Works2)**
531
532 * Click [Ethernet/CC IE/MELSECNET];
533 * Please select [Ethernet] as network type;
534 * Set station I/O number according to situation (For example, 0020 means that the module is connected to PLC CPU in first order);
535 * Select [Online] as Mode;
536 * {{id name="Iimage-20221119171343-2.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_d54f23688c520f78.png||alt="image-20221119171343-2.png" height="341" width="587"]]
537 * Click [Operation setting] to set IP;
538 * Select [Binary Code] as [Communication Data Code];
539 * {{id name="Iimage-20221119171436-3.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_ce8e6a671b9508e0.png||alt="image-20221119171436-3.png" height="354" width="588"]]
540 * Click [Open setting]
541 * Set protocol: TCP;
542 * Set [unpassive] in [Open system];
543 * Set [receive] in [Fixed buffer];
544 * Set [procedure Exist] in [Fixed buffer communication];
545 * Disable [Pairing open];
546 * Set [No confirm] in [Existence confirmation];
547 * Host station port number: 5009;
548 * Save settings;
549 * {{id name="Iimage-20221119171611-4.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_1d8e2f4fb7c72471.png||alt="image-20221119171611-4.png" height="354" width="588"]]
550 * Download project into PLC and restart it
551
552 **4)Configure the communication protocol**
553
554 {{id name="Iimage-20221119171832-5.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_50990385ef491b9e.png||alt="image-20221119171832-5.png" height="354" width="625"]]
555
556 **5)Cable Wiring**
557
558 {{id name="Ihttps:2F2Fdocs.we-con.com.cn2Fbin2Fdownload2FPIStudio2F12.PLC2520protocols2FWebHome2F12.PLC2520Protocol_html_2297240b57346b2a.png3Fwidth3D40126height3D17026rev3D1.1-2"/}}[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_2297240b57346b2a.png?width=401&height=170&rev=1.1||alt="12.PLC Protocol_html_2297240b57346b2a.png" height="38" width="76"]]