Wiki source code of Mitsubishi

Version 51.1 by Theodore Xu on 2023/09/15 10:45

Show last authors
1 == **FX1S,1N,2N Serial ** ==
2
3 Supported Series: Mitsubishi FX1S, FX1N, FX2N series
4
5 **V-BOX Settings**
6
7 |**Item**|**Settings**|**Note**
8 |Protocol|Mitsubishi FX1S/FX1N/FX2N|
9 |Connection|RS422/RS485/RS232|
10 |Baud rate|9600~~115200|
11 |Data bit|7/8|
12 |Parity|EVEN/Odd/None|
13 |Stop bit|1/2|
14 |PLC station No.|1~~255|
15
16 **Address List**
17
18 |**Type**|**Device registers**|**V-Box registers**|**Format**|**Range**|**Note**
19 |(% rowspan="7" %)Bit|X|X|Xo|0~~303237|
20 |Y|Y|Y o|0~~303237|
21 |M|M|M d|0~~99999|
22 |T|T|T d|0~~99999|
23 |C|C|C d|0~~99999|
24 |S|S|S d|0~~99999|
25 |SM|SM|SM d|8000~~9999|
26 |(% rowspan="8" %)Word|X|X|Xo|0~~303237|
27 |Y|Y|Y o|0~~303237|
28 |M|M|M d|0~~99999|
29 |T|T|T d|0~~99999|
30 |C|C|C d|0~~199|
31 |D|D|D d|0~~7999|
32 |S|S|S d|0~~99999|
33 |SD|SD|SD d|8000~~9999|
34
35 **Configure the communication protocol**
36
37 {{id name="Iimage-20220825102844-3.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_dc262f14b14cf564.png||alt="image-20220825102844-3.png" height="1011" width="1920"]]
38
39 **Cable Wiring**
40
41 **RS422**
42
43 [[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_9294a40c62eb99be.png||alt="image-20220825103350-4.png" height="284" width="723"]]
44
45 [[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_860bcf87f6ca7b98.png||alt="image-20220825100845-4.png" height="246" width="419"]]
46
47 == **FX3U,3G,3GA Serial ** ==
48
49 Supported Series: Mitsubishi FX3U, FX3G, FX3GA series
50
51 **V-BOX Settings**
52
53 |**Item**|**Settings**|**Note**
54 |Protocol|Mitsubishi FX3U/3G/3GA|
55 |Connection|RS422/RS485/RS232|
56 |Baud rate|9600~~115200|
57 |Data bit|7/8|
58 |Parity|EVEN/Odd/None|
59 |Stop bit|1/2|
60 |PLC station No.|1~~255|
61
62 **Address List**
63
64 |**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note**
65 |(% rowspan="7" %)Bit|X|X|Xo|0~~303237|
66 |Y|Y|Y o|0~~303237|
67 |M|M|M d|0~~99999|
68 |T|T|T d|0~~99999|
69 |C|C|C d|0~~99999|
70 |S|S|S d|0~~99999|
71 |SM|SM|SM d|8000~~9999|
72 |(% rowspan="8" %)Word|X|X|Xo|0~~303237|
73 |Y|Y|Y o|0~~303237|
74 |M|M|M d|0~~99999|
75 |T|T|T d|0~~99999|
76 |C|C|C d|0~~199|
77 |D|D|D d|0~~7999|
78 |S|S|S d|0~~99999|
79 |SD|SD|SD d|8000~~9999|
80
81 **Configure the communication protocol**
82
83 [[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_4d2a4921240d23c6.png||alt="image-20220825102649-2.png" height="1009" width="1920"]]
84
85 **PLC Setting**
86
87 Open GX Works2, create a new PLC project or open the project that has been created.
88 Create new project: [Project]→[New]→[Series] FXCPU→[Type] FX3G/FX3GC→[OK].
89
90 (% style="text-align:center" %)
91 [[image:1.2.png]]
92
93 PLC Default Parameters:
94 [Connection type]RS422;[Baud rate]9600, [Data bit]7, [Stop bit]1,[Parity]EVEN; [Station number]0
95 Note:The serial port parameters should be set depending on field requirements
96
97 PC and PLC connection:
98
99 [All connection]→[Connection 1]→[Transfer Setup Connection1]→[Serial USB]→RS-232C: PC and PLC are connected by USB to RS232 adapter,choose corresponding [COM Port]COM 5 →[Transmission speed]9.6Kbps→[setup] →[Parity]EVEN→[Data bits]7→[Stop bits]1→[OK]
100
101 (% style="text-align:center" %)
102 [[image:1.5.1.png]]
103
104 Connection test:when connection is OK,the GX Works2 prompts “Successfully connected with the FX3G/FX3GCCPU.”
105
106 (% style="text-align:center" %)
107 [[image:1.5.2.png]]
108
109 **Cable Wiring**
110
111 **RS422**
112
113 [[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_1e904556bb758dfe.png||alt="image-20220825103421-5.png" height="296" width="715"]]
114
115 [[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_860bcf87f6ca7b98.png||alt="image-20220825100845-4.png" height="246" width="419"]]
116
117 == **FX NOPROTOCOL** ==
118
119 Mitsubishi FX3G-RS232-BD
120
121 **V-Box Settings**
122
123 |=**Item**|=**Settings**|=**Note**
124 |Protocol|Mitsubishi FX NOPROTOCOL|
125 |Connection|RS232|
126 |Baud rate|9600|
127 |Data bit|7|
128 |Parity|EVEN|
129 |Stop bit|1|
130 |PLC station No.|0|
131
132 (% style="text-align:center" %)
133 [[image:三菱 FN盒子通讯配置.png]]
134
135 **Address List**
136
137 |=**Type**|=**Device registers**|=**HMI registers**|=**Format**|=**Range**|=**Note**
138 |(% rowspan="8" %)Bit|X|X|X o|0~~303237|
139 |Y|Y|Y o|0~~303237|
140 |M|M|M d|0~~99999|
141 |T|T|T d|0~~99999|
142 |C|C|C d|0~~99999|
143 |S|S|S d|0~~99999|
144 |SM|SM|SM d|8000~~9999|
145 |Lamp|Lamp|Lamp d|0~~0|
146 |(% rowspan="8" %)Word|X|X|X o|0~~303237|
147 |Y|Y|Y o|0~~303237|
148 |M|M|M d|0~~99999|
149 |T|T|T d|0~~99999|
150 |C|C|C d|0~~199|
151 |D|D|D d|0~~7999|
152 |S|S|S d|0~~99999|
153 |SD|SD|SD d|8000~~9999|
154
155 **Cable Wiring**
156
157 [[image:xwiki_PIStudio_12.PLC+protocols_WebHome_1717efe8d969a43c.png]]
158
159 == **FX3U Ethernet ** ==
160
161 Supported Modules: FX3U-ENET-ADP, FX3U-ENET-L
162
163 **V-BOX Settings**
164
165 |Items|Settings|Note
166 |Protocol|Mitsubishi FX3U|
167 |Connection|Ethernet|
168 |Port No.|5009|Must be the same as the PLC setting
169 |PLC station No.|0|
170
171 **Address List**
172
173 |**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note**
174 |(% rowspan="7" %)Bit|X|X|X OOO|0~~377|
175 |Y|Y|Y OOO|0~~377|
176 |M|M|M DDDD|0~~7679|
177 |SM|SM|SM DDDD|8000~~8511|
178 |S|S|S DDDD|0~~4095|
179 |TS|TS|TS DDD|0~~511|
180 |CS|CS|CS DDD|0~~255|
181 |(% rowspan="5" %)Word|CN|CN|CN DDD|0~~199|
182 |TN|TN|TN DDD|0~~511|
183 |D|D|D DDDD|0~~7999|
184 |SD|SD|SD DDDD|8000~~8511|
185 |R|R|R DDDDD|0~~32767|
186
187 **Ethernet Module Settings**
188
189 FX3U-ENET-L module configuration
190 Set up the FX3U-ENET-L Ethernet module settings as follows.
191 Select the module location, which in this document is Module 0.
192
193 [[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_949d5d77c1d9cf1e.png||alt="image-20221116105850-1.png" height="573" width="706"]]
194
195 Select "Operational setting" to enter the following screen.
196
197 The Ethernet module IP is set to 192.168.39.254 in this document, and other options are default.
198
199 [[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_dfbfdd586c855c47.png||alt="image-20221116105947-1.png" height="573" width="706"]]
200
201 Select "Open setting" to enter the setting interface, the settings are as follows.
202
203 The third item "Protocol" selects TCP, and "Open system" selects MELSOFT connection, which allows the
204
205 Mitsubishi programming software GX works2 to communicate with the FX3U via the Ethernet module.
206
207 [[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_7c01ac15090fcc5b.png||alt="image-20221116110802-1.png" height="549" width="706"]]
208
209 Click on "transter setup" - "PC side I/F setting", see the following figure.
210
211 After setting, the first download must use the programming cable, as shown in the figure; after that, can
212
213 use the IP set in the "Ethernet board" to communicate directly with the network cable.
214
215 [[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_d6fd9ce3b96f99e2.png||alt="image-20221116110832-2.png" height="423" width="708"]]
216
217 Read and write data from the Ethernet module
218
219 [[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_690b3e57b29cfd4b.png||alt="image-20221116110907-3.png" height="549" width="706"]]
220
221 Set "Transter setup" to COM communication, and read or write operation as shown below
222
223 [[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_b317253742f7151.png||alt="image-20221116110917-4.png" height="549" width="706"]]
224
225 **PLC Settings (GX Works 2)**
226
227 Create a blank FX5U project
228
229 Find Current Connection in the navigation
230
231 [[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_d2a46ba9c005cf38.png||alt="image-20221116111427-1.png" height="421" width="705"]]
232
233 Select Connection Channel List
234
235 Select Ethernet board communication
236
237 [[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_8f49721a3e5b0ef9.png||alt="image-20221116111451-2.png" height="421" width="705"]]
238
239 Select Ethernet Module
240 Set the IP address of the PLC
241
242 [[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_1e9a9e29a46a1041.png||alt="image-20221116111509-3.png" height="666" width="699"]]
243
244 Read or write PLC data, in this document is read
245
246 {{id name="Iimage-20221116111651-4.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_e3d629103727a423.png||alt="image-20221116111651-4.png" height="416" width="697"]]
247
248 [[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_7f29923ebcb670d1.png||alt="image-20221116111727-5.png" height="416" width="697"]]
249
250 **Configure the communication protocol**
251
252 [[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_b2cdc33b6eb92b67.png||alt="image-20221119101946-2.png" height="395" width="695"]]
253
254 == **FX5U Serial ** ==
255
256 Mitsubishi FX5U series PLC
257
258 **V-BOX Settings**
259
260 |**Item**|**Settings**|**Note**
261 |Protocol|Mitsubishi FX5U|
262 |Connection|RS422/RS485|
263 |Baud rate|9600|
264 |Data bit|7|
265 |Parity|Odd|
266 |Stop bit|1|
267 |PLC station No.|1~~255|Need to be the same as PLC settings
268
269 **Address List**
270
271 |**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note**
272 |(% rowspan="15" %)Bit|X|X|X o|0~~303237|
273 |Y|Y|Y o|0~~303237|
274 |M|M|M d|0~~99999|
275 |B|B|B h|0~~7FFF|
276 |F|F|F d|0~~32767|
277 |SB|SB|SB h|0~~7FFF|
278 |TS|TS|TS d|0~~1023|
279 |TC|TC|TC d|0~~1023|
280 |STS|STS|STS d|0~~1023|
281 |STC|STC|STS d|0~~1023|
282 |CS|CS|CS d|0~~1023|
283 |CC|CC|CC d|0~~1023|
284 |SM|SM|SM d|0~~9999|
285 |L|L|L d|0~~32767|
286 |S|S|S d|0~~4095|
287 |(% rowspan="9" %)Word|W|W|W h|0~~3FF|
288 |TN|TN|TN d|0~~1023|
289 |STN|STN|STN d|0~~1023|
290 |CN|CN|CN d|0~~1023|
291 |R|R|R d|0~~32767|
292 |SW|SW|SW h|0~~7FFF|
293 |Z|Z|Z d|0~~23|
294 |D|D|D d|0~~7999|
295 |SD|SD|SD d|0~~11999|
296
297 **PLC Settings (GX Works 3)**
298
299 Create a blank FX5U project
300
301 Find the 485 serial port module in the system navigation bar and double click to enter the settings.
302
303 [[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_5c9cb13fac1e6c93.png?width=200&height=462&rev=1.1||alt="12.PLC Protocol_html_5c9cb13fac1e6c93.png" height="462" width="200"]]
304
305 Select protocol in the setting item, and set parameters.
306
307 [[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_de942589ca070228.png?width=600&height=324&rev=1.1||alt="12.PLC Protocol_html_de942589ca070228.png" height="324" width="600"]]
308
309 Set station number, and [Message Pattern] (Pattern 1 or Pattern 4)
310
311 [[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_387ec7d00b5feb59.png?width=600&height=323&rev=1.1||alt="12.PLC Protocol_html_387ec7d00b5feb59.png" height="323" width="600"]]
312
313 Click the [Apply] button to finish the setting.
314
315 Click download and select the items as below, then click [execute] to download the configuration to PLC.
316
317 [[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_cdef1c5ec8cc2105.png?width=600&height=434&rev=1.1||alt="12.PLC Protocol_html_cdef1c5ec8cc2105.png" height="434" width="600"]]
318
319 As soon as download is completed, connect PLC with serial port, then configure it in the [Specify Connection Destination Connection].
320
321 Done.
322
323 **Configure the communication protocol**
324
325 {{id name="Iimage-20220825104904-1.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_dbaddd53e9951a17.png||alt="image-20220825104904-1.png" height="1033" width="1920"]]
326
327 **Cable Wiring**
328
329 **RS422**
330
331 {{id name="Iimage-20220825105105-2.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_d022c5ff4cf8c68e.png||alt="image-20220825105105-2.png" height="288" width="711"]]
332
333 {{id name="Iimage-20220825105533-3.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_50e173394c73f154.png||alt="image-20220825105533-3.png" height="246" width="420"]]
334
335 == **FX5U Ethernet ** ==
336
337 Mitsubishi FX5U series PLC
338
339 **1)V-BOX Settings**
340
341 |**Items**|**Settings**|**Note**
342 |Protocol|Mitsubishi FX5U|
343 |Connection|Ethernet|
344 |Port No.|5002|Must be the same as the PLC setting
345 |PLC station No.|0|
346
347 **2)Address List**
348
349 |**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note**
350 |(% rowspan="15" %)Bit|X|X|X o|0~~303237|
351 |Y|Y|Y o|0~~303237|
352 |M|M|M d|0~~99999|
353 |B|B|B h|0~~7FFF|
354 |F|F|F d|0~~32767|
355 |SB|SB|SB h|0~~7FFF|
356 |TS|TS|TS d|0~~1023|
357 |TC|TC|TC d|0~~1023|
358 |STS|STS|STS d|0~~1023|
359 |STC|STC|STS d|0~~1023|
360 |CS|CS|CS d|0~~1023|
361 |CC|CC|CC d|0~~1023|
362 |SM|SM|SM d|0~~9999|
363 |L|L|L d|0~~32767|
364 |S|S|S d|0~~4095|
365 |(% rowspan="9" %)Word|W|W|W h|0~~3FF|
366 |TN|TN|TN d|0~~1023|
367 |STN|STN|STN d|0~~1023|
368 |CN|CN|CN d|0~~1023|
369 |R|R|R d|0~~32767|
370 |SW|SW|SW h|0~~7FFF|
371 |Z|Z|Z d|0~~23|
372 |D|D|D d|0~~7999|
373 |SD|SD|SD d|0~~11999|
374
375 **3)PLC Settings (GX Works 3)**
376
377 Find the [Ethernet port] in the navigation area.
378
379 {{id name="Ihttps:2F2Fdocs.we-con.com.cn2Fbin2Fdownload2FPIStudio2F12.PLC2520protocols2FWebHome2F12.PLC2520Protocol_html_8e8f85ace087346c.png3Fwidth3D30026height3D59326rev3D1.1"/}}[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_8e8f85ace087346c.png?width=300&height=593&rev=1.1||alt="12.PLC Protocol_html_8e8f85ace087346c.png" height="593" width="300"]]
380
381 Select [Own Node Settings] in the [Setting Item List];
382
383 Set [IP Address], [Subnet Mask], [Default Gateway];
384
385 Click [Detailed Settings] into [Ethernet Configuration (Built-in Ethernet Port)] windows;
386
387 {{id name="Ihttps:2F2Fdocs.we-con.com.cn2Fbin2Fdownload2FPIStudio2F12.PLC2520protocols2FWebHome2F12.PLC2520Protocol_html_5d98495052c8c10e.png3Fwidth3D60026height3D33926rev3D1.1"/}}[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_5d98495052c8c10e.png?width=600&height=339&rev=1.1||alt="12.PLC Protocol_html_5d98495052c8c10e.png" height="339" width="600"]]
388
389 Select [SLMP Connection Module] and add into host station as below picture shows;
390
391 Set Port number as 5002 (this is necessary settings);
392
393 Click [Close with Reflecting the Setting] to save and close window;
394
395 {{id name="Ihttps:2F2Fdocs.we-con.com.cn2Fbin2Fdownload2FPIStudio2F12.PLC2520protocols2FWebHome2F12.PLC2520Protocol_html_14b489fdc6c6589d.png3Fwidth3D60026height3D35026rev3D1.1"/}}[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_14b489fdc6c6589d.png?width=600&height=350&rev=1.1||alt="12.PLC Protocol_html_14b489fdc6c6589d.png" height="350" width="600"]]
396
397 Click [Apply] to completed Etherenet settings;
398
399 Switch to the [On line data operation] interface as below, check the item and click [Execute] to download.
400
401 {{id name="Ihttps:2F2Fdocs.we-con.com.cn2Fbin2Fdownload2FPIStudio2F12.PLC2520protocols2FWebHome2F12.PLC2520Protocol_html_c93025a968a8a9e7.png3Fwidth3D60026height3D43426rev3D1.1"/}}[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_c93025a968a8a9e7.png?width=600&height=434&rev=1.1||alt="12.PLC Protocol_html_c93025a968a8a9e7.png" height="434" width="600"]]
402
403 **4)Configure the communication protocol**
404
405 {{id name="Iimage-20220825112403-1.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_caa9bf4d8cc6de0f.png||alt="图片-20220825112403-1.png" height="1033" width="1920"]]
406
407 **5)Cable Wiring**
408
409 [[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_2297240b57346b2a.png?width=401&height=170&rev=1.1||alt="12.可编程逻辑控制器Protocol_html_2297240b57346b2a.png" height="170" width="401"]]
410
411 == **L02 Serial ** ==
412
413 Mitsubishi L02 series CPU built-in serial port.
414
415 **V-BOX Settings**
416
417 |**Item**|**Settings**|**Note**
418 |Protocol|Mitsubishi L02|
419 |Connection|RS422|
420 |Baud rate|115200|
421 |Data bit|8|
422 |Parity|Odd|
423 |Stop bit|1|
424 |PLC station No.|1~~255|Need to be the same as PLC settings
425
426 **Address List**
427
428 |**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note**
429 |(% colspan="1" rowspan="20" %)Bit
430 |X|X|X h|0~~FFFF|
431 |Y|Y|Y h|0~~FFFF|
432 |M|M|M d|0~~9999|
433 |L|L|L d|0~~9999|
434 |F|F|F d|0~~9999|
435 |B|B|B h|0~~FFFF|
436 |V|V|V d|0~~2047|
437 |TC|TC|TC d|0~~9999|
438 |SS|SS|SS d|0~~9999|
439 |SC|SC|SC d|0~~9999|
440 |CS|CS|CS d|0~~9999|
441 |CC|CC|CC d|0~~9999|
442 |SB|SB|SB h|0~~FFFF|
443 |SM|SM|SM d|0~~2047|
444 |STS|STS|STS d|0~~1023|
445 |S|S|S d|0~~9999|
446 |DX|DX|DX h|0~~FFFF|
447 |DY|DY|DY h|0~~FFFF|
448 |TS|TS|TS d|0~~9999|
449 |Dbit|Dbit|Dbit d.d|0~~99999.0~~15|
450 |(% colspan="1" rowspan="9" %)Word
451 |W|W|W h|0~~FFFF|
452 |TN|TN|TN d|0~~99999|
453 |SN|SN|SN d|0~~99999|
454 |CN|CN|CN d|0~~99999|
455 |R|R|R d|0~~99999|
456 |SW|SW|SW h|0~~FFFF|
457 |Z|Z|Z d|0~~99999|
458 |ZR|ZR|ZR h|0~~FFFF|
459 |D|D|D d|0~~99999|
460
461 **Communication Settings**
462
463 [[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_cfed67f2ecb4ccec.png||alt="image-20220825160648-3.png" height="1009" width="1920"]]
464
465 **Cable Wiring**
466
467 **RS422**
468
469 [[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_90e38f152d639809.png||alt="image-20220825161612-8.png" height="278" width="612"]]
470
471 [[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_d301e675d8224725.png||alt="image-20220825160820-4.png" height="208" width="359"]]
472
473 == **L02 Ethernet ** ==
474
475 Mitsubishi L series CPU built-in Ethernet port.
476
477 **V-BOX Settings**
478
479 |**Items**|**Settings**|**Note**
480 |Protocol|MIT L02 CPU MELSEC|
481 |Connection|Ethernet|
482 |Port No.|1025|Must be the same as the PLC setting
483 |PLC station No.|0|Must be the same as the PLC setting
484
485 [[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_fafc9b29e20178c0.png||alt="image-20220825142659-1.png" height="1010" width="1920"]]
486
487 **PLC Settings (GX Works2 )**
488
489 Create a project
490
491 Set PLC IP, subnet mask and gateway;
492
493 Select [Binary Code] as communication data code;
494
495 [[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_776e17505f3fc6c0.png?width=600&height=524&rev=1.1||alt="12.PLC Protocol_html_776e17505f3fc6c0.png" height="524" width="600"]]
496
497 Set PLC port number, for example 1025
498
499 [[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_8d0d1a22d388f70b.png?width=600&height=524&rev=1.1||alt="12.PLC Protocol_html_8d0d1a22d388f70b.png" height="524" width="600"]]
500
501 Save settings;
502
503 Download project into PLC device;
504
505 Restart PLC device;
506
507
508 **Cable Wiring**
509
510 [[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_2297240b57346b2a.png?width=401&height=170&rev=1.1||alt="12.PLC Protocol_html_2297240b57346b2a.png" height="170" width="401"]]
511
512 == {{id name="HQ12HSerial"/}}**Q12H Serial ** ==
513
514 This Demo shows V-BOX communicate with Q12H PLC by Q02H serial Protocol
515
516 **[[Download link>>url:https://ftp.we-con.com.cn/Download/WIKI/PI%20HMI/Demo/Communication/V-Box%20connect%20PLC%20Q12H.rar]]**
517
518 == **QJ71E71 Ethernet ** ==
519
520 Mitsubishi QJ71E71 Ethernet communication module;
521
522 **V-BOX Settings**
523
524 |**Items**|**Settings**|**Note**
525 |Protocol|MIT QJ71E71 MELSEC|
526 |Connection|Ethernet|
527 |Port No.|1025|Must be the same as the PLC setting
528 |PLC station No.|0|Must be the same as the PLC setting
529
530 [[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_50990385ef491b9e.png||alt="image-20221119171832-5.png" height="354" width="625"]]
531
532 **Address List**
533
534 |**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note**
535 |(% rowspan="18" %)Bit|X|X|X h|0~~1FFF|
536 |Y|Y|Y h|0~~1FFF|
537 |M|M|M d|0~~99999|
538 |L|L|L d|0~~8191|
539 |F|F|F d|0~~2047|
540 |B|B|B h|0~~1FFF|
541 |V|V|V d|0~~2047|
542 |TS|TS|TS d|0~~2047|
543 |TC|TC|TC d|0~~2047|
544 |SS|SS|SS d|0~~2047|
545 |SC|SC|SC d|0~~2047|
546 |CS|CS|CS d|0~~1023|
547 |CC|CC|CC d|0~~1023|
548 |SB|SB|SB h|0~~7FF|
549 |S|S|S d|0~~8191|
550 |DX|DX|DX h|0~~1FFF|
551 |DY|DY|DY h|0~~1FFF|
552 |SM|SM|SM d|8000~~9999|
553 |(% rowspan="10" %)Word|SD|SD|SD d|0~~2047|
554 |D|D|D d|0~~12287|
555 |W|W|W h|0~~1FFF|
556 |TN|TN|TN d|0~~2047|
557 |SN|SN|SN d|0~~2047|
558 |CN|CN|CN d|0~~1023|
559 |R|R|R d|0~~32767|
560 |SW|SW|SW h|0~~7FF|
561 |Z|Z|Z d|0~~15|
562 |ZR|ZR|ZR h|0~~FE7FF|
563
564 **PLC Settings(GX Works2)**
565
566 * Click [Ethernet/CC IE/MELSECNET];
567 * Please select [Ethernet] as network type;
568 * Set station I/O number according to situation (For example, 0020 means that the module is connected to PLC CPU in first order);
569 * Select [Online] as Mode;
570 * [[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_d54f23688c520f78.png||alt="image-20221119171343-2.png" height="341" width="587"]]
571 * Click [Operation setting] to set IP;
572 * Select [Binary Code] as [Communication Data Code];
573 * [[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_ce8e6a671b9508e0.png||alt="image-20221119171436-3.png" height="354" width="588"]]
574 * Click [Open setting]
575 * Set protocol: TCP;
576 * Set [unpassive] in [Open system];
577 * Set [receive] in [Fixed buffer];
578 * Set [procedure Exist] in [Fixed buffer communication];
579 * Disable [Pairing open];
580 * Set [No confirm] in [Existence confirmation];
581 * Host station port number: 5009;
582 * Save settings;
583 * {{id name="Iimage-20221119171611-4.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_1d8e2f4fb7c72471.png||alt="image-20221119171611-4.png" height="354" width="588"]]
584 * Download project into PLC and restart it
585
586 **Cable Wiring**
587
588 [[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_2297240b57346b2a.png?width=401&height=170&rev=1.1||alt="12.可编程逻辑控制器Protocol_html_2297240b57346b2a.png" height="170" width="401"]]