Wiki source code of Mitsubishi

Version 54.1 by Theodore Xu on 2023/09/15 11:07

Hide last authors
Theodore Xu 39.1 1 == **FX1S,1N,2N Serial ** ==
Leo Wei 2.1 2
3 Supported Series: Mitsubishi FX1S, FX1N, FX2N series
4
Theodore Xu 37.1 5 **V-BOX Settings**
Leo Wei 2.1 6
7 |**Item**|**Settings**|**Note**
8 |Protocol|Mitsubishi FX1S/FX1N/FX2N|
9 |Connection|RS422/RS485/RS232|
10 |Baud rate|9600~~115200|
11 |Data bit|7/8|
12 |Parity|EVEN/Odd/None|
13 |Stop bit|1/2|
14 |PLC station No.|1~~255|
15
Theodore Xu 37.1 16 **Address List**
Leo Wei 2.1 17
Theodore Xu 37.1 18 |**Type**|**Device registers**|**V-Box registers**|**Format**|**Range**|**Note**
Leo Wei 2.1 19 |(% rowspan="7" %)Bit|X|X|Xo|0~~303237|
20 |Y|Y|Y o|0~~303237|
21 |M|M|M d|0~~99999|
22 |T|T|T d|0~~99999|
23 |C|C|C d|0~~99999|
24 |S|S|S d|0~~99999|
25 |SM|SM|SM d|8000~~9999|
26 |(% rowspan="8" %)Word|X|X|Xo|0~~303237|
27 |Y|Y|Y o|0~~303237|
28 |M|M|M d|0~~99999|
29 |T|T|T d|0~~99999|
30 |C|C|C d|0~~199|
31 |D|D|D d|0~~7999|
32 |S|S|S d|0~~99999|
33 |SD|SD|SD d|8000~~9999|
34
Theodore Xu 37.1 35 **Configure the communication protocol**
Leo Wei 2.1 36
37 {{id name="Iimage-20220825102844-3.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_dc262f14b14cf564.png||alt="image-20220825102844-3.png" height="1011" width="1920"]]
38
Theodore Xu 37.1 39 **Cable Wiring**
Leo Wei 2.1 40
Theodore Xu 37.1 41 **RS422**
Leo Wei 2.1 42
Theodore Xu 37.1 43 [[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_9294a40c62eb99be.png||alt="image-20220825103350-4.png" height="284" width="723"]]
Leo Wei 2.1 44
Theodore Xu 35.1 45 [[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_860bcf87f6ca7b98.png||alt="image-20220825100845-4.png" height="246" width="419"]]
Leo Wei 2.1 46
Theodore Xu 40.1 47 == **FX3U,3G,3GA Serial ** ==
Leo Wei 2.1 48
49 Supported Series: Mitsubishi FX3U, FX3G, FX3GA series
50
Theodore Xu 38.1 51 **V-BOX Settings**
Leo Wei 2.1 52
53 |**Item**|**Settings**|**Note**
54 |Protocol|Mitsubishi FX3U/3G/3GA|
55 |Connection|RS422/RS485/RS232|
56 |Baud rate|9600~~115200|
57 |Data bit|7/8|
58 |Parity|EVEN/Odd/None|
59 |Stop bit|1/2|
60 |PLC station No.|1~~255|
61
Theodore Xu 38.1 62 **Address List**
Leo Wei 2.1 63
64 |**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note**
65 |(% rowspan="7" %)Bit|X|X|Xo|0~~303237|
66 |Y|Y|Y o|0~~303237|
67 |M|M|M d|0~~99999|
68 |T|T|T d|0~~99999|
69 |C|C|C d|0~~99999|
70 |S|S|S d|0~~99999|
71 |SM|SM|SM d|8000~~9999|
72 |(% rowspan="8" %)Word|X|X|Xo|0~~303237|
73 |Y|Y|Y o|0~~303237|
74 |M|M|M d|0~~99999|
75 |T|T|T d|0~~99999|
76 |C|C|C d|0~~199|
77 |D|D|D d|0~~7999|
78 |S|S|S d|0~~99999|
79 |SD|SD|SD d|8000~~9999|
80
Theodore Xu 38.1 81 **Configure the communication protocol**
Leo Wei 2.1 82
Theodore Xu 38.1 83 [[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_4d2a4921240d23c6.png||alt="image-20220825102649-2.png" height="1009" width="1920"]]
Leo Wei 2.1 84
Theodore Xu 42.1 85 **PLC Setting**
Leo Wei 2.1 86
Theodore Xu 42.1 87 Open GX Works2, create a new PLC project or open the project that has been created.
88 Create new project: [Project]→[New]→[Series] FXCPU→[Type] FX3G/FX3GC→[OK].
89
90 (% style="text-align:center" %)
91 [[image:1.2.png]]
92
93 PLC Default Parameters:
94 [Connection type]RS422;[Baud rate]9600, [Data bit]7, [Stop bit]1,[Parity]EVEN; [Station number]0
95 Note:The serial port parameters should be set depending on field requirements
96
97 PC and PLC connection:
98
99 [All connection]→[Connection 1]→[Transfer Setup Connection1]→[Serial USB]→RS-232C: PC and PLC are connected by USB to RS232 adapter,choose corresponding [COM Port]COM 5 →[Transmission speed]9.6Kbps→[setup] →[Parity]EVEN→[Data bits]7→[Stop bits]1→[OK]
100
101 (% style="text-align:center" %)
102 [[image:1.5.1.png]]
103
104 Connection test:when connection is OK,the GX Works2 prompts “Successfully connected with the FX3G/FX3GCCPU.”
105
106 (% style="text-align:center" %)
107 [[image:1.5.2.png]]
108
109 **Cable Wiring**
110
Theodore Xu 38.1 111 **RS422**
Leo Wei 2.1 112
Theodore Xu 38.1 113 [[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_1e904556bb758dfe.png||alt="image-20220825103421-5.png" height="296" width="715"]]
Leo Wei 2.1 114
Theodore Xu 38.1 115 [[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_860bcf87f6ca7b98.png||alt="image-20220825100845-4.png" height="246" width="419"]]
Leo Wei 2.1 116
Theodore Xu 43.1 117 == **FX NOPROTOCOL** ==
118
119 Mitsubishi FX3G-RS232-BD
120
121 **V-Box Settings**
122
123 |=**Item**|=**Settings**|=**Note**
124 |Protocol|Mitsubishi FX NOPROTOCOL|
125 |Connection|RS232|
126 |Baud rate|9600|
127 |Data bit|7|
128 |Parity|EVEN|
129 |Stop bit|1|
130 |PLC station No.|0|
131
132 (% style="text-align:center" %)
133 [[image:三菱 FN盒子通讯配置.png]]
134
135 **Address List**
136
137 |=**Type**|=**Device registers**|=**HMI registers**|=**Format**|=**Range**|=**Note**
138 |(% rowspan="8" %)Bit|X|X|X o|0~~303237|
139 |Y|Y|Y o|0~~303237|
140 |M|M|M d|0~~99999|
141 |T|T|T d|0~~99999|
142 |C|C|C d|0~~99999|
143 |S|S|S d|0~~99999|
144 |SM|SM|SM d|8000~~9999|
145 |Lamp|Lamp|Lamp d|0~~0|
146 |(% rowspan="8" %)Word|X|X|X o|0~~303237|
147 |Y|Y|Y o|0~~303237|
148 |M|M|M d|0~~99999|
149 |T|T|T d|0~~99999|
150 |C|C|C d|0~~199|
151 |D|D|D d|0~~7999|
152 |S|S|S d|0~~99999|
153 |SD|SD|SD d|8000~~9999|
154
Theodore Xu 45.1 155 **Cable Wiring**
Theodore Xu 43.1 156
Theodore Xu 44.1 157 [[image:xwiki_PIStudio_12.PLC+protocols_WebHome_1717efe8d969a43c.png]]
158
Theodore Xu 41.1 159 == **FX3U Ethernet ** ==
Leo Wei 2.1 160
161 Supported Modules: FX3U-ENET-ADP, FX3U-ENET-L
162
Theodore Xu 41.1 163 **V-BOX Settings**
Leo Wei 2.1 164
165 |Items|Settings|Note
166 |Protocol|Mitsubishi FX3U|
167 |Connection|Ethernet|
168 |Port No.|5009|Must be the same as the PLC setting
169 |PLC station No.|0|
170
Theodore Xu 41.1 171 **Address List**
Leo Wei 2.1 172
173 |**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note**
174 |(% rowspan="7" %)Bit|X|X|X OOO|0~~377|
175 |Y|Y|Y OOO|0~~377|
176 |M|M|M DDDD|0~~7679|
177 |SM|SM|SM DDDD|8000~~8511|
178 |S|S|S DDDD|0~~4095|
179 |TS|TS|TS DDD|0~~511|
180 |CS|CS|CS DDD|0~~255|
181 |(% rowspan="5" %)Word|CN|CN|CN DDD|0~~199|
182 |TN|TN|TN DDD|0~~511|
183 |D|D|D DDDD|0~~7999|
184 |SD|SD|SD DDDD|8000~~8511|
185 |R|R|R DDDDD|0~~32767|
186
Theodore Xu 41.1 187 **Ethernet Module Settings**
Leo Wei 2.1 188
189 FX3U-ENET-L module configuration
190 Set up the FX3U-ENET-L Ethernet module settings as follows.
191 Select the module location, which in this document is Module 0.
192
Theodore Xu 41.1 193 [[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_949d5d77c1d9cf1e.png||alt="image-20221116105850-1.png" height="573" width="706"]]
Leo Wei 2.1 194
195 Select "Operational setting" to enter the following screen.
196
197 The Ethernet module IP is set to 192.168.39.254 in this document, and other options are default.
198
Theodore Xu 41.1 199 [[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_dfbfdd586c855c47.png||alt="image-20221116105947-1.png" height="573" width="706"]]
Leo Wei 2.1 200
201 Select "Open setting" to enter the setting interface, the settings are as follows.
202
203 The third item "Protocol" selects TCP, and "Open system" selects MELSOFT connection, which allows the
204
205 Mitsubishi programming software GX works2 to communicate with the FX3U via the Ethernet module.
206
Theodore Xu 41.1 207 [[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_7c01ac15090fcc5b.png||alt="image-20221116110802-1.png" height="549" width="706"]]
Leo Wei 2.1 208
209 Click on "transter setup" - "PC side I/F setting", see the following figure.
210
211 After setting, the first download must use the programming cable, as shown in the figure; after that, can
212
213 use the IP set in the "Ethernet board" to communicate directly with the network cable.
214
Theodore Xu 41.1 215 [[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_d6fd9ce3b96f99e2.png||alt="image-20221116110832-2.png" height="423" width="708"]]
Leo Wei 2.1 216
217 Read and write data from the Ethernet module
218
Theodore Xu 41.1 219 [[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_690b3e57b29cfd4b.png||alt="image-20221116110907-3.png" height="549" width="706"]]
Leo Wei 2.1 220
221 Set "Transter setup" to COM communication, and read or write operation as shown below
222
Theodore Xu 41.1 223 [[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_b317253742f7151.png||alt="image-20221116110917-4.png" height="549" width="706"]]
Leo Wei 2.1 224
Theodore Xu 41.1 225 **PLC Settings (GX Works 2)**
Leo Wei 2.1 226
227 Create a blank FX5U project
228
229 Find Current Connection in the navigation
230
Theodore Xu 41.1 231 [[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_d2a46ba9c005cf38.png||alt="image-20221116111427-1.png" height="421" width="705"]]
Leo Wei 2.1 232
233 Select Connection Channel List
234
235 Select Ethernet board communication
236
Theodore Xu 41.1 237 [[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_8f49721a3e5b0ef9.png||alt="image-20221116111451-2.png" height="421" width="705"]]
Leo Wei 2.1 238
239 Select Ethernet Module
240 Set the IP address of the PLC
241
Theodore Xu 41.1 242 [[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_1e9a9e29a46a1041.png||alt="image-20221116111509-3.png" height="666" width="699"]]
Leo Wei 2.1 243
244 Read or write PLC data, in this document is read
245
246 {{id name="Iimage-20221116111651-4.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_e3d629103727a423.png||alt="image-20221116111651-4.png" height="416" width="697"]]
247
Theodore Xu 41.1 248 [[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_7f29923ebcb670d1.png||alt="image-20221116111727-5.png" height="416" width="697"]]
Leo Wei 2.1 249
Theodore Xu 41.1 250 **Configure the communication protocol**
Leo Wei 2.1 251
Theodore Xu 41.1 252 [[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_b2cdc33b6eb92b67.png||alt="image-20221119101946-2.png" height="395" width="695"]]
Leo Wei 2.1 253
Theodore Xu 46.1 254 == **FX5U Serial ** ==
Leo Wei 2.1 255
256 Mitsubishi FX5U series PLC
257
Theodore Xu 46.1 258 **V-BOX Settings**
Leo Wei 2.1 259
260 |**Item**|**Settings**|**Note**
261 |Protocol|Mitsubishi FX5U|
262 |Connection|RS422/RS485|
263 |Baud rate|9600|
264 |Data bit|7|
265 |Parity|Odd|
266 |Stop bit|1|
267 |PLC station No.|1~~255|Need to be the same as PLC settings
268
Theodore Xu 54.1 269 (% style="text-align:center" %)
270 [[image:三菱 FX5U 串口协议配置.png]]
271
Theodore Xu 46.1 272 **Address List**
Leo Wei 2.1 273
274 |**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note**
275 |(% rowspan="15" %)Bit|X|X|X o|0~~303237|
276 |Y|Y|Y o|0~~303237|
277 |M|M|M d|0~~99999|
278 |B|B|B h|0~~7FFF|
279 |F|F|F d|0~~32767|
280 |SB|SB|SB h|0~~7FFF|
281 |TS|TS|TS d|0~~1023|
282 |TC|TC|TC d|0~~1023|
283 |STS|STS|STS d|0~~1023|
284 |STC|STC|STS d|0~~1023|
285 |CS|CS|CS d|0~~1023|
286 |CC|CC|CC d|0~~1023|
287 |SM|SM|SM d|0~~9999|
288 |L|L|L d|0~~32767|
289 |S|S|S d|0~~4095|
290 |(% rowspan="9" %)Word|W|W|W h|0~~3FF|
291 |TN|TN|TN d|0~~1023|
292 |STN|STN|STN d|0~~1023|
293 |CN|CN|CN d|0~~1023|
294 |R|R|R d|0~~32767|
295 |SW|SW|SW h|0~~7FFF|
296 |Z|Z|Z d|0~~23|
297 |D|D|D d|0~~7999|
298 |SD|SD|SD d|0~~11999|
299
Theodore Xu 46.1 300 **PLC Settings (GX Works 3)**
Leo Wei 2.1 301
302 Create a blank FX5U project
303
304 Find the 485 serial port module in the system navigation bar and double click to enter the settings.
305
Theodore Xu 46.1 306 [[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_5c9cb13fac1e6c93.png?width=200&height=462&rev=1.1||alt="12.PLC Protocol_html_5c9cb13fac1e6c93.png" height="462" width="200"]]
Leo Wei 2.1 307
308 Select protocol in the setting item, and set parameters.
309
Theodore Xu 46.1 310 [[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_de942589ca070228.png?width=600&height=324&rev=1.1||alt="12.PLC Protocol_html_de942589ca070228.png" height="324" width="600"]]
Leo Wei 2.1 311
312 Set station number, and [Message Pattern] (Pattern 1 or Pattern 4)
313
Theodore Xu 46.1 314 [[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_387ec7d00b5feb59.png?width=600&height=323&rev=1.1||alt="12.PLC Protocol_html_387ec7d00b5feb59.png" height="323" width="600"]]
Leo Wei 2.1 315
316 Click the [Apply] button to finish the setting.
317
318 Click download and select the items as below, then click [execute] to download the configuration to PLC.
319
Theodore Xu 46.1 320 [[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_cdef1c5ec8cc2105.png?width=600&height=434&rev=1.1||alt="12.PLC Protocol_html_cdef1c5ec8cc2105.png" height="434" width="600"]]
Leo Wei 2.1 321
322 As soon as download is completed, connect PLC with serial port, then configure it in the [Specify Connection Destination Connection].
323
324 Done.
325
Theodore Xu 46.1 326 **Cable Wiring**
Leo Wei 2.1 327
Theodore Xu 46.1 328 **RS422**
Leo Wei 2.1 329
330 {{id name="Iimage-20220825105105-2.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_d022c5ff4cf8c68e.png||alt="image-20220825105105-2.png" height="288" width="711"]]
331
332 {{id name="Iimage-20220825105533-3.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_50e173394c73f154.png||alt="image-20220825105533-3.png" height="246" width="420"]]
333
Theodore Xu 33.1 334 == **FX5U Ethernet ** ==
Leo Wei 2.1 335
336 Mitsubishi FX5U series PLC
337
338 **1)V-BOX Settings**
339
340 |**Items**|**Settings**|**Note**
341 |Protocol|Mitsubishi FX5U|
342 |Connection|Ethernet|
343 |Port No.|5002|Must be the same as the PLC setting
344 |PLC station No.|0|
345
346 **2)Address List**
347
348 |**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note**
349 |(% rowspan="15" %)Bit|X|X|X o|0~~303237|
350 |Y|Y|Y o|0~~303237|
351 |M|M|M d|0~~99999|
352 |B|B|B h|0~~7FFF|
353 |F|F|F d|0~~32767|
354 |SB|SB|SB h|0~~7FFF|
355 |TS|TS|TS d|0~~1023|
356 |TC|TC|TC d|0~~1023|
357 |STS|STS|STS d|0~~1023|
358 |STC|STC|STS d|0~~1023|
359 |CS|CS|CS d|0~~1023|
360 |CC|CC|CC d|0~~1023|
361 |SM|SM|SM d|0~~9999|
362 |L|L|L d|0~~32767|
363 |S|S|S d|0~~4095|
364 |(% rowspan="9" %)Word|W|W|W h|0~~3FF|
365 |TN|TN|TN d|0~~1023|
366 |STN|STN|STN d|0~~1023|
367 |CN|CN|CN d|0~~1023|
368 |R|R|R d|0~~32767|
369 |SW|SW|SW h|0~~7FFF|
370 |Z|Z|Z d|0~~23|
371 |D|D|D d|0~~7999|
372 |SD|SD|SD d|0~~11999|
373
374 **3)PLC Settings (GX Works 3)**
375
376 Find the [Ethernet port] in the navigation area.
377
378 {{id name="Ihttps:2F2Fdocs.we-con.com.cn2Fbin2Fdownload2FPIStudio2F12.PLC2520protocols2FWebHome2F12.PLC2520Protocol_html_8e8f85ace087346c.png3Fwidth3D30026height3D59326rev3D1.1"/}}[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_8e8f85ace087346c.png?width=300&height=593&rev=1.1||alt="12.PLC Protocol_html_8e8f85ace087346c.png" height="593" width="300"]]
379
380 Select [Own Node Settings] in the [Setting Item List];
381
382 Set [IP Address], [Subnet Mask], [Default Gateway];
383
384 Click [Detailed Settings] into [Ethernet Configuration (Built-in Ethernet Port)] windows;
385
386 {{id name="Ihttps:2F2Fdocs.we-con.com.cn2Fbin2Fdownload2FPIStudio2F12.PLC2520protocols2FWebHome2F12.PLC2520Protocol_html_5d98495052c8c10e.png3Fwidth3D60026height3D33926rev3D1.1"/}}[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_5d98495052c8c10e.png?width=600&height=339&rev=1.1||alt="12.PLC Protocol_html_5d98495052c8c10e.png" height="339" width="600"]]
387
388 Select [SLMP Connection Module] and add into host station as below picture shows;
389
390 Set Port number as 5002 (this is necessary settings);
391
392 Click [Close with Reflecting the Setting] to save and close window;
393
394 {{id name="Ihttps:2F2Fdocs.we-con.com.cn2Fbin2Fdownload2FPIStudio2F12.PLC2520protocols2FWebHome2F12.PLC2520Protocol_html_14b489fdc6c6589d.png3Fwidth3D60026height3D35026rev3D1.1"/}}[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_14b489fdc6c6589d.png?width=600&height=350&rev=1.1||alt="12.PLC Protocol_html_14b489fdc6c6589d.png" height="350" width="600"]]
395
396 Click [Apply] to completed Etherenet settings;
397
398 Switch to the [On line data operation] interface as below, check the item and click [Execute] to download.
399
400 {{id name="Ihttps:2F2Fdocs.we-con.com.cn2Fbin2Fdownload2FPIStudio2F12.PLC2520protocols2FWebHome2F12.PLC2520Protocol_html_c93025a968a8a9e7.png3Fwidth3D60026height3D43426rev3D1.1"/}}[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_c93025a968a8a9e7.png?width=600&height=434&rev=1.1||alt="12.PLC Protocol_html_c93025a968a8a9e7.png" height="434" width="600"]]
401
402 **4)Configure the communication protocol**
403
404 {{id name="Iimage-20220825112403-1.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_caa9bf4d8cc6de0f.png||alt="图片-20220825112403-1.png" height="1033" width="1920"]]
405
406 **5)Cable Wiring**
407
Theodore Xu 33.1 408 [[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_2297240b57346b2a.png?width=401&height=170&rev=1.1||alt="12.可编程逻辑控制器Protocol_html_2297240b57346b2a.png" height="170" width="401"]]
Leo Wei 2.1 409
Theodore Xu 47.1 410 == **L02 Serial ** ==
Leo Wei 2.1 411
412 Mitsubishi L02 series CPU built-in serial port.
413
Theodore Xu 47.1 414 **V-BOX Settings**
Leo Wei 2.1 415
416 |**Item**|**Settings**|**Note**
417 |Protocol|Mitsubishi L02|
418 |Connection|RS422|
419 |Baud rate|115200|
420 |Data bit|8|
421 |Parity|Odd|
422 |Stop bit|1|
423 |PLC station No.|1~~255|Need to be the same as PLC settings
424
Theodore Xu 53.1 425 (% style="text-align:center" %)
426 [[image:三菱 L02串口协议配置.png]]
427
Theodore Xu 47.1 428 **Address List**
Leo Wei 2.1 429
430 |**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note**
Theodore Xu 47.1 431 |(% colspan="1" rowspan="20" %)Bit
432 |X|X|X h|0~~FFFF|
433 |Y|Y|Y h|0~~FFFF|
434 |M|M|M d|0~~9999|
435 |L|L|L d|0~~9999|
436 |F|F|F d|0~~9999|
437 |B|B|B h|0~~FFFF|
438 |V|V|V d|0~~2047|
439 |TC|TC|TC d|0~~9999|
440 |SS|SS|SS d|0~~9999|
441 |SC|SC|SC d|0~~9999|
442 |CS|CS|CS d|0~~9999|
443 |CC|CC|CC d|0~~9999|
444 |SB|SB|SB h|0~~FFFF|
445 |SM|SM|SM d|0~~2047|
446 |STS|STS|STS d|0~~1023|
447 |S|S|S d|0~~9999|
448 |DX|DX|DX h|0~~FFFF|
449 |DY|DY|DY h|0~~FFFF|
450 |TS|TS|TS d|0~~9999|
451 |Dbit|Dbit|Dbit d.d|0~~99999.0~~15|
452 |(% colspan="1" rowspan="9" %)Word
453 |W|W|W h|0~~FFFF|
454 |TN|TN|TN d|0~~99999|
455 |SN|SN|SN d|0~~99999|
456 |CN|CN|CN d|0~~99999|
457 |R|R|R d|0~~99999|
458 |SW|SW|SW h|0~~FFFF|
459 |Z|Z|Z d|0~~99999|
460 |ZR|ZR|ZR h|0~~FFFF|
461 |D|D|D d|0~~99999|
Leo Wei 2.1 462
Theodore Xu 47.1 463 **Cable Wiring**
Leo Wei 2.1 464
Theodore Xu 47.1 465 **RS422**
Leo Wei 2.1 466
Theodore Xu 47.1 467 [[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_90e38f152d639809.png||alt="image-20220825161612-8.png" height="278" width="612"]]
Leo Wei 2.1 468
Theodore Xu 47.1 469 [[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_d301e675d8224725.png||alt="image-20220825160820-4.png" height="208" width="359"]]
Leo Wei 2.1 470
Theodore Xu 48.1 471 == **L02 Ethernet ** ==
Leo Wei 2.1 472
473 Mitsubishi L series CPU built-in Ethernet port.
474
Theodore Xu 48.1 475 **V-BOX Settings**
Leo Wei 2.1 476
477 |**Items**|**Settings**|**Note**
478 |Protocol|MIT L02 CPU MELSEC|
479 |Connection|Ethernet|
480 |Port No.|1025|Must be the same as the PLC setting
481 |PLC station No.|0|Must be the same as the PLC setting
482
Theodore Xu 52.1 483 (% style="text-align:center" %)
484 [[image:三菱 L02以太网协议配置1.png]]
Theodore Xu 51.1 485
Theodore Xu 48.1 486 **PLC Settings (GX Works2 )**
Leo Wei 2.1 487
488 Create a project
489
490 Set PLC IP, subnet mask and gateway;
491
492 Select [Binary Code] as communication data code;
493
Theodore Xu 49.1 494 [[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_776e17505f3fc6c0.png?width=600&height=524&rev=1.1||alt="12.PLC Protocol_html_776e17505f3fc6c0.png" height="524" width="600"]]
Leo Wei 2.1 495
496 Set PLC port number, for example 1025
497
Theodore Xu 49.1 498 [[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_8d0d1a22d388f70b.png?width=600&height=524&rev=1.1||alt="12.PLC Protocol_html_8d0d1a22d388f70b.png" height="524" width="600"]]
Leo Wei 2.1 499
500 Save settings;
501
502 Download project into PLC device;
503
504 Restart PLC device;
505
Theodore Xu 49.1 506 **Cable Wiring**
Leo Wei 2.1 507
Theodore Xu 49.1 508 [[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_2297240b57346b2a.png?width=401&height=170&rev=1.1||alt="12.PLC Protocol_html_2297240b57346b2a.png" height="170" width="401"]]
Leo Wei 2.1 509
510 == {{id name="HQ12HSerial"/}}**Q12H Serial ** ==
511
512 This Demo shows V-BOX communicate with Q12H PLC by Q02H serial Protocol
513
514 **[[Download link>>url:https://ftp.we-con.com.cn/Download/WIKI/PI%20HMI/Demo/Communication/V-Box%20connect%20PLC%20Q12H.rar]]**
515
Theodore Xu 32.1 516 == **QJ71E71 Ethernet ** ==
Leo Wei 2.1 517
518 Mitsubishi QJ71E71 Ethernet communication module;
519
Theodore Xu 50.1 520 **V-BOX Settings**
Leo Wei 2.1 521
522 |**Items**|**Settings**|**Note**
523 |Protocol|MIT QJ71E71 MELSEC|
524 |Connection|Ethernet|
525 |Port No.|1025|Must be the same as the PLC setting
526 |PLC station No.|0|Must be the same as the PLC setting
527
Theodore Xu 50.1 528 [[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_50990385ef491b9e.png||alt="image-20221119171832-5.png" height="354" width="625"]]
Leo Wei 2.1 529
Theodore Xu 50.1 530 **Address List**
531
Leo Wei 2.1 532 |**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note**
533 |(% rowspan="18" %)Bit|X|X|X h|0~~1FFF|
534 |Y|Y|Y h|0~~1FFF|
535 |M|M|M d|0~~99999|
536 |L|L|L d|0~~8191|
537 |F|F|F d|0~~2047|
538 |B|B|B h|0~~1FFF|
539 |V|V|V d|0~~2047|
540 |TS|TS|TS d|0~~2047|
541 |TC|TC|TC d|0~~2047|
542 |SS|SS|SS d|0~~2047|
543 |SC|SC|SC d|0~~2047|
544 |CS|CS|CS d|0~~1023|
545 |CC|CC|CC d|0~~1023|
546 |SB|SB|SB h|0~~7FF|
547 |S|S|S d|0~~8191|
548 |DX|DX|DX h|0~~1FFF|
549 |DY|DY|DY h|0~~1FFF|
550 |SM|SM|SM d|8000~~9999|
551 |(% rowspan="10" %)Word|SD|SD|SD d|0~~2047|
552 |D|D|D d|0~~12287|
553 |W|W|W h|0~~1FFF|
554 |TN|TN|TN d|0~~2047|
555 |SN|SN|SN d|0~~2047|
556 |CN|CN|CN d|0~~1023|
557 |R|R|R d|0~~32767|
558 |SW|SW|SW h|0~~7FF|
559 |Z|Z|Z d|0~~15|
560 |ZR|ZR|ZR h|0~~FE7FF|
561
Theodore Xu 50.1 562 **PLC Settings(GX Works2)**
Leo Wei 2.1 563
564 * Click [Ethernet/CC IE/MELSECNET];
565 * Please select [Ethernet] as network type;
566 * Set station I/O number according to situation (For example, 0020 means that the module is connected to PLC CPU in first order);
567 * Select [Online] as Mode;
Theodore Xu 50.1 568 * [[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_d54f23688c520f78.png||alt="image-20221119171343-2.png" height="341" width="587"]]
Leo Wei 2.1 569 * Click [Operation setting] to set IP;
570 * Select [Binary Code] as [Communication Data Code];
Theodore Xu 50.1 571 * [[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_ce8e6a671b9508e0.png||alt="image-20221119171436-3.png" height="354" width="588"]]
Leo Wei 2.1 572 * Click [Open setting]
573 * Set protocol: TCP;
574 * Set [unpassive] in [Open system];
575 * Set [receive] in [Fixed buffer];
576 * Set [procedure Exist] in [Fixed buffer communication];
577 * Disable [Pairing open];
578 * Set [No confirm] in [Existence confirmation];
579 * Host station port number: 5009;
580 * Save settings;
581 * {{id name="Iimage-20221119171611-4.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_1d8e2f4fb7c72471.png||alt="image-20221119171611-4.png" height="354" width="588"]]
582 * Download project into PLC and restart it
583
Theodore Xu 50.1 584 **Cable Wiring**
Leo Wei 2.1 585
Theodore Xu 34.1 586 [[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_2297240b57346b2a.png?width=401&height=170&rev=1.1||alt="12.可编程逻辑控制器Protocol_html_2297240b57346b2a.png" height="170" width="401"]]