Wiki source code of Mitsubishi

Version 55.1 by Theodore Xu on 2023/09/15 11:10

Show last authors
1 == **FX1S,1N,2N Serial ** ==
2
3 Supported Series: Mitsubishi FX1S, FX1N, FX2N series
4
5 **V-BOX Settings**
6
7 |**Item**|**Settings**|**Note**
8 |Protocol|Mitsubishi FX1S/FX1N/FX2N|
9 |Connection|RS422/RS485/RS232|
10 |Baud rate|9600~~115200|
11 |Data bit|7/8|
12 |Parity|EVEN/Odd/None|
13 |Stop bit|1/2|
14 |PLC station No.|1~~255|
15
16 [[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_dc262f14b14cf564.png||alt="image-20220825102844-3.png" height="1011" width="1920"]]
17
18 **Address List**
19
20 |**Type**|**Device registers**|**V-Box registers**|**Format**|**Range**|**Note**
21 |(% rowspan="7" %)Bit|X|X|Xo|0~~303237|
22 |Y|Y|Y o|0~~303237|
23 |M|M|M d|0~~99999|
24 |T|T|T d|0~~99999|
25 |C|C|C d|0~~99999|
26 |S|S|S d|0~~99999|
27 |SM|SM|SM d|8000~~9999|
28 |(% rowspan="8" %)Word|X|X|Xo|0~~303237|
29 |Y|Y|Y o|0~~303237|
30 |M|M|M d|0~~99999|
31 |T|T|T d|0~~99999|
32 |C|C|C d|0~~199|
33 |D|D|D d|0~~7999|
34 |S|S|S d|0~~99999|
35 |SD|SD|SD d|8000~~9999|
36
37 **Cable Wiring**
38
39 **RS422**
40
41 [[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_9294a40c62eb99be.png||alt="image-20220825103350-4.png" height="284" width="723"]]
42
43 [[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_860bcf87f6ca7b98.png||alt="image-20220825100845-4.png" height="246" width="419"]]
44
45 == **FX3U,3G,3GA Serial ** ==
46
47 Supported Series: Mitsubishi FX3U, FX3G, FX3GA series
48
49 **V-BOX Settings**
50
51 |**Item**|**Settings**|**Note**
52 |Protocol|Mitsubishi FX3U/3G/3GA|
53 |Connection|RS422/RS485/RS232|
54 |Baud rate|9600~~115200|
55 |Data bit|7/8|
56 |Parity|EVEN/Odd/None|
57 |Stop bit|1/2|
58 |PLC station No.|1~~255|
59
60 **Address List**
61
62 |**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note**
63 |(% rowspan="7" %)Bit|X|X|Xo|0~~303237|
64 |Y|Y|Y o|0~~303237|
65 |M|M|M d|0~~99999|
66 |T|T|T d|0~~99999|
67 |C|C|C d|0~~99999|
68 |S|S|S d|0~~99999|
69 |SM|SM|SM d|8000~~9999|
70 |(% rowspan="8" %)Word|X|X|Xo|0~~303237|
71 |Y|Y|Y o|0~~303237|
72 |M|M|M d|0~~99999|
73 |T|T|T d|0~~99999|
74 |C|C|C d|0~~199|
75 |D|D|D d|0~~7999|
76 |S|S|S d|0~~99999|
77 |SD|SD|SD d|8000~~9999|
78
79 **Configure the communication protocol**
80
81 [[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_4d2a4921240d23c6.png||alt="image-20220825102649-2.png" height="1009" width="1920"]]
82
83 **PLC Setting**
84
85 Open GX Works2, create a new PLC project or open the project that has been created.
86 Create new project: [Project]→[New]→[Series] FXCPU→[Type] FX3G/FX3GC→[OK].
87
88 (% style="text-align:center" %)
89 [[image:1.2.png]]
90
91 PLC Default Parameters:
92 [Connection type]RS422;[Baud rate]9600, [Data bit]7, [Stop bit]1,[Parity]EVEN; [Station number]0
93 Note:The serial port parameters should be set depending on field requirements
94
95 PC and PLC connection:
96
97 [All connection]→[Connection 1]→[Transfer Setup Connection1]→[Serial USB]→RS-232C: PC and PLC are connected by USB to RS232 adapter,choose corresponding [COM Port]COM 5 →[Transmission speed]9.6Kbps→[setup] →[Parity]EVEN→[Data bits]7→[Stop bits]1→[OK]
98
99 (% style="text-align:center" %)
100 [[image:1.5.1.png]]
101
102 Connection test:when connection is OK,the GX Works2 prompts “Successfully connected with the FX3G/FX3GCCPU.”
103
104 (% style="text-align:center" %)
105 [[image:1.5.2.png]]
106
107 **Cable Wiring**
108
109 **RS422**
110
111 [[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_1e904556bb758dfe.png||alt="image-20220825103421-5.png" height="296" width="715"]]
112
113 [[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_860bcf87f6ca7b98.png||alt="image-20220825100845-4.png" height="246" width="419"]]
114
115 == **FX NOPROTOCOL** ==
116
117 Mitsubishi FX3G-RS232-BD
118
119 **V-Box Settings**
120
121 |=**Item**|=**Settings**|=**Note**
122 |Protocol|Mitsubishi FX NOPROTOCOL|
123 |Connection|RS232|
124 |Baud rate|9600|
125 |Data bit|7|
126 |Parity|EVEN|
127 |Stop bit|1|
128 |PLC station No.|0|
129
130 (% style="text-align:center" %)
131 [[image:三菱 FN盒子通讯配置.png]]
132
133 **Address List**
134
135 |=**Type**|=**Device registers**|=**HMI registers**|=**Format**|=**Range**|=**Note**
136 |(% rowspan="8" %)Bit|X|X|X o|0~~303237|
137 |Y|Y|Y o|0~~303237|
138 |M|M|M d|0~~99999|
139 |T|T|T d|0~~99999|
140 |C|C|C d|0~~99999|
141 |S|S|S d|0~~99999|
142 |SM|SM|SM d|8000~~9999|
143 |Lamp|Lamp|Lamp d|0~~0|
144 |(% rowspan="8" %)Word|X|X|X o|0~~303237|
145 |Y|Y|Y o|0~~303237|
146 |M|M|M d|0~~99999|
147 |T|T|T d|0~~99999|
148 |C|C|C d|0~~199|
149 |D|D|D d|0~~7999|
150 |S|S|S d|0~~99999|
151 |SD|SD|SD d|8000~~9999|
152
153 **Cable Wiring**
154
155 [[image:xwiki_PIStudio_12.PLC+protocols_WebHome_1717efe8d969a43c.png]]
156
157 == **FX3U Ethernet ** ==
158
159 Supported Modules: FX3U-ENET-ADP, FX3U-ENET-L
160
161 **V-BOX Settings**
162
163 |Items|Settings|Note
164 |Protocol|Mitsubishi FX3U|
165 |Connection|Ethernet|
166 |Port No.|5009|Must be the same as the PLC setting
167 |PLC station No.|0|
168
169 **Address List**
170
171 |**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note**
172 |(% rowspan="7" %)Bit|X|X|X OOO|0~~377|
173 |Y|Y|Y OOO|0~~377|
174 |M|M|M DDDD|0~~7679|
175 |SM|SM|SM DDDD|8000~~8511|
176 |S|S|S DDDD|0~~4095|
177 |TS|TS|TS DDD|0~~511|
178 |CS|CS|CS DDD|0~~255|
179 |(% rowspan="5" %)Word|CN|CN|CN DDD|0~~199|
180 |TN|TN|TN DDD|0~~511|
181 |D|D|D DDDD|0~~7999|
182 |SD|SD|SD DDDD|8000~~8511|
183 |R|R|R DDDDD|0~~32767|
184
185 **Ethernet Module Settings**
186
187 FX3U-ENET-L module configuration
188 Set up the FX3U-ENET-L Ethernet module settings as follows.
189 Select the module location, which in this document is Module 0.
190
191 [[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_949d5d77c1d9cf1e.png||alt="image-20221116105850-1.png" height="573" width="706"]]
192
193 Select "Operational setting" to enter the following screen.
194
195 The Ethernet module IP is set to 192.168.39.254 in this document, and other options are default.
196
197 [[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_dfbfdd586c855c47.png||alt="image-20221116105947-1.png" height="573" width="706"]]
198
199 Select "Open setting" to enter the setting interface, the settings are as follows.
200
201 The third item "Protocol" selects TCP, and "Open system" selects MELSOFT connection, which allows the
202
203 Mitsubishi programming software GX works2 to communicate with the FX3U via the Ethernet module.
204
205 [[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_7c01ac15090fcc5b.png||alt="image-20221116110802-1.png" height="549" width="706"]]
206
207 Click on "transter setup" - "PC side I/F setting", see the following figure.
208
209 After setting, the first download must use the programming cable, as shown in the figure; after that, can
210
211 use the IP set in the "Ethernet board" to communicate directly with the network cable.
212
213 [[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_d6fd9ce3b96f99e2.png||alt="image-20221116110832-2.png" height="423" width="708"]]
214
215 Read and write data from the Ethernet module
216
217 [[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_690b3e57b29cfd4b.png||alt="image-20221116110907-3.png" height="549" width="706"]]
218
219 Set "Transter setup" to COM communication, and read or write operation as shown below
220
221 [[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_b317253742f7151.png||alt="image-20221116110917-4.png" height="549" width="706"]]
222
223 **PLC Settings (GX Works 2)**
224
225 Create a blank FX5U project
226
227 Find Current Connection in the navigation
228
229 [[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_d2a46ba9c005cf38.png||alt="image-20221116111427-1.png" height="421" width="705"]]
230
231 Select Connection Channel List
232
233 Select Ethernet board communication
234
235 [[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_8f49721a3e5b0ef9.png||alt="image-20221116111451-2.png" height="421" width="705"]]
236
237 Select Ethernet Module
238 Set the IP address of the PLC
239
240 [[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_1e9a9e29a46a1041.png||alt="image-20221116111509-3.png" height="666" width="699"]]
241
242 Read or write PLC data, in this document is read
243
244 {{id name="Iimage-20221116111651-4.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_e3d629103727a423.png||alt="image-20221116111651-4.png" height="416" width="697"]]
245
246 [[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_7f29923ebcb670d1.png||alt="image-20221116111727-5.png" height="416" width="697"]]
247
248 **Configure the communication protocol**
249
250 [[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_b2cdc33b6eb92b67.png||alt="image-20221119101946-2.png" height="395" width="695"]]
251
252 == **FX5U Serial ** ==
253
254 Mitsubishi FX5U series PLC
255
256 **V-BOX Settings**
257
258 |**Item**|**Settings**|**Note**
259 |Protocol|Mitsubishi FX5U|
260 |Connection|RS422/RS485|
261 |Baud rate|9600|
262 |Data bit|7|
263 |Parity|Odd|
264 |Stop bit|1|
265 |PLC station No.|1~~255|Need to be the same as PLC settings
266
267 (% style="text-align:center" %)
268 [[image:三菱 FX5U 串口协议配置.png]]
269
270 **Address List**
271
272 |**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note**
273 |(% rowspan="15" %)Bit|X|X|X o|0~~303237|
274 |Y|Y|Y o|0~~303237|
275 |M|M|M d|0~~99999|
276 |B|B|B h|0~~7FFF|
277 |F|F|F d|0~~32767|
278 |SB|SB|SB h|0~~7FFF|
279 |TS|TS|TS d|0~~1023|
280 |TC|TC|TC d|0~~1023|
281 |STS|STS|STS d|0~~1023|
282 |STC|STC|STS d|0~~1023|
283 |CS|CS|CS d|0~~1023|
284 |CC|CC|CC d|0~~1023|
285 |SM|SM|SM d|0~~9999|
286 |L|L|L d|0~~32767|
287 |S|S|S d|0~~4095|
288 |(% rowspan="9" %)Word|W|W|W h|0~~3FF|
289 |TN|TN|TN d|0~~1023|
290 |STN|STN|STN d|0~~1023|
291 |CN|CN|CN d|0~~1023|
292 |R|R|R d|0~~32767|
293 |SW|SW|SW h|0~~7FFF|
294 |Z|Z|Z d|0~~23|
295 |D|D|D d|0~~7999|
296 |SD|SD|SD d|0~~11999|
297
298 **PLC Settings (GX Works 3)**
299
300 Create a blank FX5U project
301
302 Find the 485 serial port module in the system navigation bar and double click to enter the settings.
303
304 [[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_5c9cb13fac1e6c93.png?width=200&height=462&rev=1.1||alt="12.PLC Protocol_html_5c9cb13fac1e6c93.png" height="462" width="200"]]
305
306 Select protocol in the setting item, and set parameters.
307
308 [[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_de942589ca070228.png?width=600&height=324&rev=1.1||alt="12.PLC Protocol_html_de942589ca070228.png" height="324" width="600"]]
309
310 Set station number, and [Message Pattern] (Pattern 1 or Pattern 4)
311
312 [[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_387ec7d00b5feb59.png?width=600&height=323&rev=1.1||alt="12.PLC Protocol_html_387ec7d00b5feb59.png" height="323" width="600"]]
313
314 Click the [Apply] button to finish the setting.
315
316 Click download and select the items as below, then click [execute] to download the configuration to PLC.
317
318 [[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_cdef1c5ec8cc2105.png?width=600&height=434&rev=1.1||alt="12.PLC Protocol_html_cdef1c5ec8cc2105.png" height="434" width="600"]]
319
320 As soon as download is completed, connect PLC with serial port, then configure it in the [Specify Connection Destination Connection].
321
322 Done.
323
324 **Cable Wiring**
325
326 **RS422**
327
328 {{id name="Iimage-20220825105105-2.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_d022c5ff4cf8c68e.png||alt="image-20220825105105-2.png" height="288" width="711"]]
329
330 {{id name="Iimage-20220825105533-3.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_50e173394c73f154.png||alt="image-20220825105533-3.png" height="246" width="420"]]
331
332 == **FX5U Ethernet ** ==
333
334 Mitsubishi FX5U series PLC
335
336 **1)V-BOX Settings**
337
338 |**Items**|**Settings**|**Note**
339 |Protocol|Mitsubishi FX5U|
340 |Connection|Ethernet|
341 |Port No.|5002|Must be the same as the PLC setting
342 |PLC station No.|0|
343
344 **2)Address List**
345
346 |**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note**
347 |(% rowspan="15" %)Bit|X|X|X o|0~~303237|
348 |Y|Y|Y o|0~~303237|
349 |M|M|M d|0~~99999|
350 |B|B|B h|0~~7FFF|
351 |F|F|F d|0~~32767|
352 |SB|SB|SB h|0~~7FFF|
353 |TS|TS|TS d|0~~1023|
354 |TC|TC|TC d|0~~1023|
355 |STS|STS|STS d|0~~1023|
356 |STC|STC|STS d|0~~1023|
357 |CS|CS|CS d|0~~1023|
358 |CC|CC|CC d|0~~1023|
359 |SM|SM|SM d|0~~9999|
360 |L|L|L d|0~~32767|
361 |S|S|S d|0~~4095|
362 |(% rowspan="9" %)Word|W|W|W h|0~~3FF|
363 |TN|TN|TN d|0~~1023|
364 |STN|STN|STN d|0~~1023|
365 |CN|CN|CN d|0~~1023|
366 |R|R|R d|0~~32767|
367 |SW|SW|SW h|0~~7FFF|
368 |Z|Z|Z d|0~~23|
369 |D|D|D d|0~~7999|
370 |SD|SD|SD d|0~~11999|
371
372 **3)PLC Settings (GX Works 3)**
373
374 Find the [Ethernet port] in the navigation area.
375
376 {{id name="Ihttps:2F2Fdocs.we-con.com.cn2Fbin2Fdownload2FPIStudio2F12.PLC2520protocols2FWebHome2F12.PLC2520Protocol_html_8e8f85ace087346c.png3Fwidth3D30026height3D59326rev3D1.1"/}}[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_8e8f85ace087346c.png?width=300&height=593&rev=1.1||alt="12.PLC Protocol_html_8e8f85ace087346c.png" height="593" width="300"]]
377
378 Select [Own Node Settings] in the [Setting Item List];
379
380 Set [IP Address], [Subnet Mask], [Default Gateway];
381
382 Click [Detailed Settings] into [Ethernet Configuration (Built-in Ethernet Port)] windows;
383
384 {{id name="Ihttps:2F2Fdocs.we-con.com.cn2Fbin2Fdownload2FPIStudio2F12.PLC2520protocols2FWebHome2F12.PLC2520Protocol_html_5d98495052c8c10e.png3Fwidth3D60026height3D33926rev3D1.1"/}}[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_5d98495052c8c10e.png?width=600&height=339&rev=1.1||alt="12.PLC Protocol_html_5d98495052c8c10e.png" height="339" width="600"]]
385
386 Select [SLMP Connection Module] and add into host station as below picture shows;
387
388 Set Port number as 5002 (this is necessary settings);
389
390 Click [Close with Reflecting the Setting] to save and close window;
391
392 {{id name="Ihttps:2F2Fdocs.we-con.com.cn2Fbin2Fdownload2FPIStudio2F12.PLC2520protocols2FWebHome2F12.PLC2520Protocol_html_14b489fdc6c6589d.png3Fwidth3D60026height3D35026rev3D1.1"/}}[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_14b489fdc6c6589d.png?width=600&height=350&rev=1.1||alt="12.PLC Protocol_html_14b489fdc6c6589d.png" height="350" width="600"]]
393
394 Click [Apply] to completed Etherenet settings;
395
396 Switch to the [On line data operation] interface as below, check the item and click [Execute] to download.
397
398 {{id name="Ihttps:2F2Fdocs.we-con.com.cn2Fbin2Fdownload2FPIStudio2F12.PLC2520protocols2FWebHome2F12.PLC2520Protocol_html_c93025a968a8a9e7.png3Fwidth3D60026height3D43426rev3D1.1"/}}[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_c93025a968a8a9e7.png?width=600&height=434&rev=1.1||alt="12.PLC Protocol_html_c93025a968a8a9e7.png" height="434" width="600"]]
399
400 **4)Configure the communication protocol**
401
402 {{id name="Iimage-20220825112403-1.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_caa9bf4d8cc6de0f.png||alt="图片-20220825112403-1.png" height="1033" width="1920"]]
403
404 **5)Cable Wiring**
405
406 [[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_2297240b57346b2a.png?width=401&height=170&rev=1.1||alt="12.可编程逻辑控制器Protocol_html_2297240b57346b2a.png" height="170" width="401"]]
407
408 == **L02 Serial ** ==
409
410 Mitsubishi L02 series CPU built-in serial port.
411
412 **V-BOX Settings**
413
414 |**Item**|**Settings**|**Note**
415 |Protocol|Mitsubishi L02|
416 |Connection|RS422|
417 |Baud rate|115200|
418 |Data bit|8|
419 |Parity|Odd|
420 |Stop bit|1|
421 |PLC station No.|1~~255|Need to be the same as PLC settings
422
423 (% style="text-align:center" %)
424 [[image:三菱 L02串口协议配置.png]]
425
426 **Address List**
427
428 |**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note**
429 |(% colspan="1" rowspan="20" %)Bit
430 |X|X|X h|0~~FFFF|
431 |Y|Y|Y h|0~~FFFF|
432 |M|M|M d|0~~9999|
433 |L|L|L d|0~~9999|
434 |F|F|F d|0~~9999|
435 |B|B|B h|0~~FFFF|
436 |V|V|V d|0~~2047|
437 |TC|TC|TC d|0~~9999|
438 |SS|SS|SS d|0~~9999|
439 |SC|SC|SC d|0~~9999|
440 |CS|CS|CS d|0~~9999|
441 |CC|CC|CC d|0~~9999|
442 |SB|SB|SB h|0~~FFFF|
443 |SM|SM|SM d|0~~2047|
444 |STS|STS|STS d|0~~1023|
445 |S|S|S d|0~~9999|
446 |DX|DX|DX h|0~~FFFF|
447 |DY|DY|DY h|0~~FFFF|
448 |TS|TS|TS d|0~~9999|
449 |Dbit|Dbit|Dbit d.d|0~~99999.0~~15|
450 |(% colspan="1" rowspan="9" %)Word
451 |W|W|W h|0~~FFFF|
452 |TN|TN|TN d|0~~99999|
453 |SN|SN|SN d|0~~99999|
454 |CN|CN|CN d|0~~99999|
455 |R|R|R d|0~~99999|
456 |SW|SW|SW h|0~~FFFF|
457 |Z|Z|Z d|0~~99999|
458 |ZR|ZR|ZR h|0~~FFFF|
459 |D|D|D d|0~~99999|
460
461 **Cable Wiring**
462
463 **RS422**
464
465 [[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_90e38f152d639809.png||alt="image-20220825161612-8.png" height="278" width="612"]]
466
467 [[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_d301e675d8224725.png||alt="image-20220825160820-4.png" height="208" width="359"]]
468
469 == **L02 Ethernet ** ==
470
471 Mitsubishi L series CPU built-in Ethernet port.
472
473 **V-BOX Settings**
474
475 |**Items**|**Settings**|**Note**
476 |Protocol|MIT L02 CPU MELSEC|
477 |Connection|Ethernet|
478 |Port No.|1025|Must be the same as the PLC setting
479 |PLC station No.|0|Must be the same as the PLC setting
480
481 (% style="text-align:center" %)
482 [[image:三菱 L02以太网协议配置1.png]]
483
484 **PLC Settings (GX Works2 )**
485
486 Create a project
487
488 Set PLC IP, subnet mask and gateway;
489
490 Select [Binary Code] as communication data code;
491
492 [[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_776e17505f3fc6c0.png?width=600&height=524&rev=1.1||alt="12.PLC Protocol_html_776e17505f3fc6c0.png" height="524" width="600"]]
493
494 Set PLC port number, for example 1025
495
496 [[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_8d0d1a22d388f70b.png?width=600&height=524&rev=1.1||alt="12.PLC Protocol_html_8d0d1a22d388f70b.png" height="524" width="600"]]
497
498 Save settings;
499
500 Download project into PLC device;
501
502 Restart PLC device;
503
504 **Cable Wiring**
505
506 [[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_2297240b57346b2a.png?width=401&height=170&rev=1.1||alt="12.PLC Protocol_html_2297240b57346b2a.png" height="170" width="401"]]
507
508 == {{id name="HQ12HSerial"/}}**Q12H Serial ** ==
509
510 This Demo shows V-BOX communicate with Q12H PLC by Q02H serial Protocol
511
512 **[[Download link>>url:https://ftp.we-con.com.cn/Download/WIKI/PI%20HMI/Demo/Communication/V-Box%20connect%20PLC%20Q12H.rar]]**
513
514 == **QJ71E71 Ethernet ** ==
515
516 Mitsubishi QJ71E71 Ethernet communication module;
517
518 **V-BOX Settings**
519
520 |**Items**|**Settings**|**Note**
521 |Protocol|MIT QJ71E71 MELSEC|
522 |Connection|Ethernet|
523 |Port No.|1025|Must be the same as the PLC setting
524 |PLC station No.|0|Must be the same as the PLC setting
525
526 [[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_50990385ef491b9e.png||alt="image-20221119171832-5.png" height="354" width="625"]]
527
528 **Address List**
529
530 |**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note**
531 |(% rowspan="18" %)Bit|X|X|X h|0~~1FFF|
532 |Y|Y|Y h|0~~1FFF|
533 |M|M|M d|0~~99999|
534 |L|L|L d|0~~8191|
535 |F|F|F d|0~~2047|
536 |B|B|B h|0~~1FFF|
537 |V|V|V d|0~~2047|
538 |TS|TS|TS d|0~~2047|
539 |TC|TC|TC d|0~~2047|
540 |SS|SS|SS d|0~~2047|
541 |SC|SC|SC d|0~~2047|
542 |CS|CS|CS d|0~~1023|
543 |CC|CC|CC d|0~~1023|
544 |SB|SB|SB h|0~~7FF|
545 |S|S|S d|0~~8191|
546 |DX|DX|DX h|0~~1FFF|
547 |DY|DY|DY h|0~~1FFF|
548 |SM|SM|SM d|8000~~9999|
549 |(% rowspan="10" %)Word|SD|SD|SD d|0~~2047|
550 |D|D|D d|0~~12287|
551 |W|W|W h|0~~1FFF|
552 |TN|TN|TN d|0~~2047|
553 |SN|SN|SN d|0~~2047|
554 |CN|CN|CN d|0~~1023|
555 |R|R|R d|0~~32767|
556 |SW|SW|SW h|0~~7FF|
557 |Z|Z|Z d|0~~15|
558 |ZR|ZR|ZR h|0~~FE7FF|
559
560 **PLC Settings(GX Works2)**
561
562 * Click [Ethernet/CC IE/MELSECNET];
563 * Please select [Ethernet] as network type;
564 * Set station I/O number according to situation (For example, 0020 means that the module is connected to PLC CPU in first order);
565 * Select [Online] as Mode;
566 * [[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_d54f23688c520f78.png||alt="image-20221119171343-2.png" height="341" width="587"]]
567 * Click [Operation setting] to set IP;
568 * Select [Binary Code] as [Communication Data Code];
569 * [[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_ce8e6a671b9508e0.png||alt="image-20221119171436-3.png" height="354" width="588"]]
570 * Click [Open setting]
571 * Set protocol: TCP;
572 * Set [unpassive] in [Open system];
573 * Set [receive] in [Fixed buffer];
574 * Set [procedure Exist] in [Fixed buffer communication];
575 * Disable [Pairing open];
576 * Set [No confirm] in [Existence confirmation];
577 * Host station port number: 5009;
578 * Save settings;
579 * {{id name="Iimage-20221119171611-4.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_1d8e2f4fb7c72471.png||alt="image-20221119171611-4.png" height="354" width="588"]]
580 * Download project into PLC and restart it
581