| 1 | == **FX3U,3G,3GA Serial ** == | ||
| 2 | |||
| 3 | Supported Series: Mitsubishi FX3U, FX3G, FX3GA series | ||
| 4 | |||
| 5 | **V-BOX Settings** | ||
| 6 | |||
| 7 | |**Item**|**Settings**|**Note** | ||
| 8 | |Protocol|Mitsubishi FX3U/3G/3GA| | ||
| 9 | |Connection|RS422/RS485/RS232| | ||
| 10 | |Baud rate|9600~~115200| | ||
| 11 | |Data bit|7/8| | ||
| 12 | |Parity|EVEN/Odd/None| | ||
| 13 | |Stop bit|1/2| | ||
| 14 | |PLC station No.|1~~255| | ||
| 15 | |||
| 16 | (% style="text-align:center" %) | ||
| 17 | [[image:三菱 FX3U 串口协议配置.png]] | ||
| 18 | |||
| 19 | **Address List** | ||
| 20 | |||
| 21 | |**Type**|**Device registers**|**Format**|**Range**|**Note** | ||
| 22 | |(% rowspan="7" %)Bit|X|X o|0~~303237| | ||
| 23 | |Y|Y o|0~~303237| | ||
| 24 | |M|M d|0~~99999| | ||
| 25 | |T|T d|0~~99999| | ||
| 26 | |C|C d|0~~99999| | ||
| 27 | |S|S d|0~~99999| | ||
| 28 | |SM|SM d|8000~~9999| | ||
| 29 | |(% rowspan="8" %)Word|X|X o|0~~303237| | ||
| 30 | |Y|Y o|0~~303237| | ||
| 31 | |M|M d|0~~99999| | ||
| 32 | |T|T d|0~~99999| | ||
| 33 | |C|C d|0~~199| | ||
| 34 | |D|D d|0~~7999| | ||
| 35 | |S|S d|0~~99999| | ||
| 36 | |SD|SD d|8000~~9999| | ||
| 37 | |||
| 38 | **PLC Setting** | ||
| 39 | |||
| 40 | Open GX Works2, create a new PLC project or open the project that has been created. | ||
| 41 | Create new project: [Project]→[New]→[Series] FXCPU→[Type] FX3G/FX3GC→[OK]. | ||
| 42 | |||
| 43 | (% style="text-align:center" %) | ||
| 44 | [[image:GX2.png]] | ||
| 45 | |||
| 46 | (% style="text-align:center" %) | ||
| 47 | [[image:1.2.png]] | ||
| 48 | |||
| 49 | PLC Default Parameters: | ||
| 50 | [Connection type]RS422;[Baud rate]9600, [Data bit]7, [Stop bit]1,[Parity]EVEN; [Station number]0 | ||
| 51 | Note:The serial port parameters should be set depending on field requirements | ||
| 52 | |||
| 53 | PC and PLC connection: | ||
| 54 | |||
| 55 | [All connection]→[Connection 1]→[Transfer Setup Connection1]→[Serial USB]→RS-232C: PC and PLC are connected by USB to RS232 adapter,choose corresponding [COM Port]COM 5 →[Transmission speed]9.6Kbps→[setup] →[Parity]EVEN→[Data bits]7→[Stop bits]1→[OK] | ||
| 56 | |||
| 57 | (% style="text-align:center" %) | ||
| 58 | [[image:1.5.1.png]] | ||
| 59 | |||
| 60 | Connection test:when connection is OK,the GX Works2 prompts “Successfully connected with the FX3G/FX3GCCPU.” | ||
| 61 | |||
| 62 | (% style="text-align:center" %) | ||
| 63 | [[image:1.5.2.png]] | ||
| 64 | |||
| 65 | [PLC]→[Write to PLC]→[Online operation]→[Param+program]→[Execute]→[OK] | ||
| 66 | |||
| 67 | (% style="text-align:center" %) | ||
| 68 | [[image:FX3U串口下载.png]] | ||
| 69 | |||
| 70 | **Cable Wiring** | ||
| 71 | |||
| 72 | **RS422** | ||
| 73 | |||
| 74 | [[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_1e904556bb758dfe.png||alt="image-20220825103421-5.png" height="296" width="715"]] | ||
| 75 | |||
| 76 | [[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_860bcf87f6ca7b98.png||alt="image-20220825100845-4.png" height="246" width="419"]] | ||
| 77 | |||
| 78 | == **FX NOPROTOCOL** == | ||
| 79 | |||
| 80 | Mitsubishi FX3G-RS232-BD | ||
| 81 | |||
| 82 | **V-Box Settings** | ||
| 83 | |||
| 84 | |=**Item**|=**Settings**|=**Note** | ||
| 85 | |Protocol|Mitsubishi FX NOPROTOCOL| | ||
| 86 | |Connection|RS232| | ||
| 87 | |Baud rate|9600| | ||
| 88 | |Data bit|7| | ||
| 89 | |Parity|EVEN| | ||
| 90 | |Stop bit|1| | ||
| 91 | |PLC station No.|0| | ||
| 92 | |||
| 93 | (% style="text-align:center" %) | ||
| 94 | [[image:三菱 FN盒子通讯配置.png]] | ||
| 95 | |||
| 96 | **Address List** | ||
| 97 | |||
| 98 | |=**Type**|=**Device registers**|=**Format**|=**Range**|=**Note** | ||
| 99 | |(% rowspan="8" %)Bit|X|X o|0~~303237| | ||
| 100 | |Y|Y o|0~~303237| | ||
| 101 | |M|M d|0~~99999| | ||
| 102 | |T|T d|0~~99999| | ||
| 103 | |C|C d|0~~99999| | ||
| 104 | |S|S d|0~~99999| | ||
| 105 | |SM|SM d|8000~~9999| | ||
| 106 | |Lamp|Lamp d|0~~0| | ||
| 107 | |(% rowspan="8" %)Word|X|X o|0~~303237| | ||
| 108 | |Y|Y o|0~~303237| | ||
| 109 | |M|M d|0~~99999| | ||
| 110 | |T|T d|0~~99999| | ||
| 111 | |C|C d|0~~199| | ||
| 112 | |D|D d|0~~7999| | ||
| 113 | |S|S d|0~~99999| | ||
| 114 | |SD|SD d|8000~~9999| | ||
| 115 | |||
| 116 | **Cable Wiring** | ||
| 117 | |||
| 118 | [[image:xwiki_PIStudio_12.PLC+protocols_WebHome_1717efe8d969a43c.png]] | ||
| 119 | |||
| 120 | == **FX3U Ethernet ** == | ||
| 121 | |||
| 122 | Supported Modules: FX3U-ENET-ADP, FX3U-ENET-L | ||
| 123 | |||
| 124 | **V-BOX Settings** | ||
| 125 | |||
| 126 | |Items|Settings|Note | ||
| 127 | |Protocol|Mitsubishi FX3U| | ||
| 128 | |Connection|Ethernet| | ||
| 129 | |Port No.|5009|Must be the same as the PLC setting | ||
| 130 | |PLC station No.|0| | ||
| 131 | |||
| 132 | (% style="text-align:center" %) | ||
| 133 | [[image:三菱 FX3U 以太网协议配置.png]] | ||
| 134 | |||
| 135 | **Address List** | ||
| 136 | |||
| 137 | |**Type**|**Device registers**|**Format**|**Range**|**Note** | ||
| 138 | |(% rowspan="7" %)Bit|X|X OOO|0~~377| | ||
| 139 | |Y|Y OOO|0~~377| | ||
| 140 | |M|M DDDD|0~~7679| | ||
| 141 | |SM|SM DDDD|8000~~8511| | ||
| 142 | |S|S DDDD|0~~4095| | ||
| 143 | |TS|TS DDD|0~~511| | ||
| 144 | |CS|CS DDD|0~~255| | ||
| 145 | |(% rowspan="5" %)Word|CN|CN DDD|0~~199| | ||
| 146 | |TN|TN DDD|0~~511| | ||
| 147 | |D|D DDDD|0~~7999| | ||
| 148 | |SD|SD DDDD|8000~~8511| | ||
| 149 | |R|R DDDDD|0~~32767| | ||
| 150 | |||
| 151 | **Ethernet Module Settings** | ||
| 152 | |||
| 153 | FX3U-ENET-L module configuration | ||
| 154 | Set up the FX3U-ENET-L Ethernet module settings as follows. | ||
| 155 | Select the module location, which in this document is Module 0. | ||
| 156 | |||
| 157 | [[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_949d5d77c1d9cf1e.png||alt="image-20221116105850-1.png" height="573" width="706"]] | ||
| 158 | |||
| 159 | Select "Operational setting" to enter the following screen. | ||
| 160 | |||
| 161 | The Ethernet module IP is set to 192.168.39.254 in this document, and other options are default. | ||
| 162 | |||
| 163 | |||
| 164 | (% style="text-align:center" %) | ||
| 165 | [[image:Inku25HyY8.png]] | ||
| 166 | |||
| 167 | Select "Open setting" to enter the setting interface, the settings are as follows. | ||
| 168 | |||
| 169 | The third item "Protocol" selects TCP, and "Open system" selects MELSOFT connection, which allows the | ||
| 170 | |||
| 171 | Mitsubishi programming software GX works2 to communicate with the FX3U via the Ethernet module. | ||
| 172 | |||
| 173 | [[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_7c01ac15090fcc5b.png||alt="image-20221116110802-1.png" height="549" width="706"]] | ||
| 174 | |||
| 175 | (% class="box infomessage" %) | ||
| 176 | ((( | ||
| 177 | Note: If you can't communicate PLC to box normally, changing ''No confirm" to "confirm" | ||
| 178 | ))) | ||
| 179 | |||
| 180 | Click on "transter setup" - "PC side I/F setting", see the following figure. | ||
| 181 | |||
| 182 | After setting, the first download must use the programming cable, as shown in the figure; after that, can | ||
| 183 | |||
| 184 | use the IP set in the "Ethernet board" to communicate directly with the network cable. | ||
| 185 | |||
| 186 | |||
| 187 | (% style="text-align:center" %) | ||
| 188 | [[image:WstTyoGrxG.png]] | ||
| 189 | |||
| 190 | (% style="text-align:center" %) | ||
| 191 | [[image:aak9XC8xDH.png]] | ||
| 192 | |||
| 193 | |||
| 194 | |||
| 195 | **PLC Settings (GX Works 2)** | ||
| 196 | |||
| 197 | Create a blank FX5U project | ||
| 198 | |||
| 199 | Find Current Connection in the navigation | ||
| 200 | |||
| 201 | [[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_d2a46ba9c005cf38.png||alt="image-20221116111427-1.png" height="421" width="705"]] | ||
| 202 | |||
| 203 | Select Connection Channel List | ||
| 204 | |||
| 205 | Select Ethernet board communication | ||
| 206 | |||
| 207 | [[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_8f49721a3e5b0ef9.png||alt="image-20221116111451-2.png" height="421" width="705"]] | ||
| 208 | |||
| 209 | Select Ethernet Module | ||
| 210 | Set the IP address of the PLC | ||
| 211 | |||
| 212 | [[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_1e9a9e29a46a1041.png||alt="image-20221116111509-3.png" height="666" width="699"]] | ||
| 213 | |||
| 214 | Read or write PLC data, in this document is read | ||
| 215 | |||
| 216 | {{id name="Iimage-20221116111651-4.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_e3d629103727a423.png||alt="image-20221116111651-4.png" height="416" width="697"]] | ||
| 217 | |||
| 218 | [[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_7f29923ebcb670d1.png||alt="image-20221116111727-5.png" height="416" width="697"]] | ||
| 219 | |||
| 220 | == **FX5U Serial ** == | ||
| 221 | |||
| 222 | Mitsubishi FX5U series PLC | ||
| 223 | |||
| 224 | **V-BOX Settings** | ||
| 225 | |||
| 226 | |**Item**|**Settings**|**Note** | ||
| 227 | |Protocol|Mitsubishi FX5U| | ||
| 228 | |Connection|RS422/RS485| | ||
| 229 | |Baud rate|9600| | ||
| 230 | |Data bit|7| | ||
| 231 | |Parity|Odd| | ||
| 232 | |Stop bit|1| | ||
| 233 | |PLC station No.|1~~255|Need to be the same as PLC settings | ||
| 234 | |||
| 235 | (% style="text-align:center" %) | ||
| 236 | [[image:三菱 FX5U 串口协议配置.png]] | ||
| 237 | |||
| 238 | **Address List** | ||
| 239 | |||
| 240 | |**Type**|**Device registers**|**Format**|**Range**|**Note** | ||
| 241 | |(% rowspan="15" %)Bit|X|X o|0~~303237| | ||
| 242 | |Y|Y o|0~~303237| | ||
| 243 | |M|M d|0~~99999| | ||
| 244 | |B|B h|0~~7FFF| | ||
| 245 | |F|F d|0~~32767| | ||
| 246 | |SB|SB h|0~~7FFF| | ||
| 247 | |TS|TS d|0~~1023| | ||
| 248 | |TC|TC d|0~~1023| | ||
| 249 | |STS|STS d|0~~1023| | ||
| 250 | |STC|STS d|0~~1023| | ||
| 251 | |CS|CS d|0~~1023| | ||
| 252 | |CC|CC d|0~~1023| | ||
| 253 | |SM|SM d|0~~9999| | ||
| 254 | |L|L d|0~~32767| | ||
| 255 | |S|S d|0~~4095| | ||
| 256 | |(% rowspan="9" %)Word|W|W h|0~~3FF| | ||
| 257 | |TN|TN d|0~~1023| | ||
| 258 | |STN|STN d|0~~1023| | ||
| 259 | |CN|CN d|0~~1023| | ||
| 260 | |R|R d|0~~32767| | ||
| 261 | |SW|SW h|0~~7FFF| | ||
| 262 | |Z|Z d|0~~23| | ||
| 263 | |D|D d|0~~7999| | ||
| 264 | |SD|SD d|0~~11999| | ||
| 265 | |||
| 266 | **PLC Settings ** | ||
| 267 | |||
| 268 | Create a blank FX5U project | ||
| 269 | |||
| 270 | Open GX Works3, create a new PLC project or open the project that has been created. Create new project: [Project]→[New]→[Series] FX5CPU→[Type] FX5U→[OK]. | ||
| 271 | |||
| 272 | (% style="text-align:center" %) | ||
| 273 | [[image:GX3.png]] | ||
| 274 | |||
| 275 | |||
| 276 | (% style="text-align:center" %) | ||
| 277 | [[image:FX5U 串口选型号.png]] | ||
| 278 | |||
| 279 | PLC Default Parameters: | ||
| 280 | [Navigation]→[Parameter]→[FX5UCPU]→[Module Parameter]→[485 Serial Port]:[Basic Settings] →[ Communication Protocol Type] MC Protocol→[Advanced Settings]:[Baud rate]9600Kbps, [Data Length]7, [Stop bit]1,[Parity]Odd. | ||
| 281 | |||
| 282 | (% style="text-align:center" %) | ||
| 283 | [[image:FX5U plc串口参数配置.png]] | ||
| 284 | |||
| 285 | |||
| 286 | [Navigation]→[Parameter]→[FX5UCPU]→[Module Parameter]→[485 Serial Port]: [fixed Setting] →[Station No.]0→[Message Pattern] Pattern 1 (X,Y OCT)→[Apply] | ||
| 287 | |||
| 288 | {{info}} | ||
| 289 | **✎Note:** The serial port parameters should be set depending on field requirements. | ||
| 290 | {{/info}} | ||
| 291 | |||
| 292 | (% style="text-align:center" %) | ||
| 293 | [[image:FX5U plc串口参数.png]] | ||
| 294 | |||
| 295 | **Cable Wiring** | ||
| 296 | |||
| 297 | **RS422** | ||
| 298 | |||
| 299 | [[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_d022c5ff4cf8c68e.png||alt="image-20220825105105-2.png" height="288" width="711"]] | ||
| 300 | |||
| 301 | [[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_50e173394c73f154.png||alt="image-20220825105533-3.png" height="246" width="420"]] | ||
| 302 | |||
| 303 | == **FX5U Ethernet ** == | ||
| 304 | |||
| 305 | Mitsubishi FX5U series PLC | ||
| 306 | |||
| 307 | **V-BOX Settings** | ||
| 308 | |||
| 309 | |**Items**|**Settings**|**Note** | ||
| 310 | |Protocol|Mitsubishi FX5U| | ||
| 311 | |Connection|Ethernet| | ||
| 312 | |Port No.|5002|Must be the same as the PLC setting | ||
| 313 | |PLC station No.|0| | ||
| 314 | |||
| 315 | (% style="text-align:center" %) | ||
| 316 | [[image:三菱 FX5U 以太网协议配置.png]] | ||
| 317 | |||
| 318 | **Address List** | ||
| 319 | |||
| 320 | |**Type**|**Device registers**|**Format**|**Range**|**Note** | ||
| 321 | |(% rowspan="15" %)Bit|X|X o|0~~303237| | ||
| 322 | |Y|Y o|0~~303237| | ||
| 323 | |M|M d|0~~99999| | ||
| 324 | |B|B h|0~~7FFF| | ||
| 325 | |F|F d|0~~32767| | ||
| 326 | |SB|SB h|0~~7FFF| | ||
| 327 | |TS|TS d|0~~1023| | ||
| 328 | |TC|TC d|0~~1023| | ||
| 329 | |STS|STS d|0~~1023| | ||
| 330 | |STC|STS d|0~~1023| | ||
| 331 | |CS|CS d|0~~1023| | ||
| 332 | |CC|CC d|0~~1023| | ||
| 333 | |SM|SM d|0~~9999| | ||
| 334 | |L|L d|0~~32767| | ||
| 335 | |S|S d|0~~4095| | ||
| 336 | |(% rowspan="9" %)Word|W|W h|0~~3FF| | ||
| 337 | |TN|TN d|0~~1023| | ||
| 338 | |STN|STN d|0~~1023| | ||
| 339 | |CN|CN d|0~~1023| | ||
| 340 | |R|R d|0~~32767| | ||
| 341 | |SW|SW h|0~~7FFF| | ||
| 342 | |Z|Z d|0~~23| | ||
| 343 | |D|D d|0~~7999| | ||
| 344 | |SD|SD d|0~~11999| | ||
| 345 | |||
| 346 | **PLC Settings ** | ||
| 347 | |||
| 348 | Open GX Works3, create a new PLC project or open the project that has been created. | ||
| 349 | |||
| 350 | Create new project: [Project]→[New]→[Series] FX5CPU→[Type] FX5U→[OK]. | ||
| 351 | |||
| 352 | (% style="text-align:center" %) | ||
| 353 | [[image:GX3.png]] | ||
| 354 | |||
| 355 | (% style="text-align:center" %) | ||
| 356 | [[image:FX5U 串口选型号.png]] | ||
| 357 | |||
| 358 | PLC Default Parameters: | ||
| 359 | [Navigation]→[Parameter]→[FX5UCPU]→[Module Parameter]→[Ethernet Port]:[Basic Settings] →[Own node settings]:[IP Address]192.168.40.11, [Subnet Mask]255.255.255.0, [Default Gateway]192.168.40.1,[ Communication Data Code] Binary. | ||
| 360 | |||
| 361 | (% style="text-align:center" %) | ||
| 362 | [[image:FX5U 以太网配置.png]] | ||
| 363 | |||
| 364 | [External Device Configuration]→[Detailed Settings]→[Ethernet Configuration(Built-in Ethernet Port)]→[Ethernet Device (General)]→[SLMP Connection Module] Drag under Host for Connection No.1→[Port No.]5002→[Close with Reflecting the Setting] | ||
| 365 | |||
| 366 | (% style="text-align:center" %) | ||
| 367 | [[image:1.3.2.png]] | ||
| 368 | |||
| 369 | PC and PLC connection | ||
| 370 | |||
| 371 | [Online]→[Current Connection Destination]→[Direct Coupled Setting]→[Ethernet]→[Adapter] Realtek PCIe GBE Family Controller→[Communication Test]: Successfully connected with the FX5UCPU. | ||
| 372 | |||
| 373 | (% style="text-align:center" %) | ||
| 374 | [[image:FX5U 以太网连接PLC.png]] | ||
| 375 | |||
| 376 | Downloading PLC project | ||
| 377 | [Online]→[Write to PLC]→[Online Data operation]→[Param+program]→[Execute]→[Yes] →[Yes to all] | ||
| 378 | |||
| 379 | (% style="text-align:center" %) | ||
| 380 | [[image:FX5U以太网下载.png]] | ||
| 381 | |||
| 382 | **Cable Wiring** | ||
| 383 | |||
| 384 | [[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_2297240b57346b2a.png?width=401&height=170&rev=1.1||alt="12.可编程逻辑控制器Protocol_html_2297240b57346b2a.png" height="170" width="401"]] | ||
| 385 | |||
| 386 | == **L02 Serial ** == | ||
| 387 | |||
| 388 | Mitsubishi L02 series CPU built-in serial port. | ||
| 389 | |||
| 390 | **V-BOX Settings** | ||
| 391 | |||
| 392 | |**Item**|**Settings**|**Note** | ||
| 393 | |Protocol|Mitsubishi L02| | ||
| 394 | |Connection|RS422| | ||
| 395 | |Baud rate|115200| | ||
| 396 | |Data bit|8| | ||
| 397 | |Parity|Odd| | ||
| 398 | |Stop bit|1| | ||
| 399 | |PLC station No.|1~~255|Need to be the same as PLC settings | ||
| 400 | |||
| 401 | (% style="text-align:center" %) | ||
| 402 | [[image:三菱 L02串口协议配置.png]] | ||
| 403 | |||
| 404 | **Address List** | ||
| 405 | |||
| 406 | |**Type**|**Device registers**|**Format**|**Range**|**Note** | ||
| 407 | |(% colspan="1" rowspan="20" %)Bit | ||
| 408 | |X|X h|0~~FFFF| | ||
| 409 | |Y|Y h|0~~FFFF| | ||
| 410 | |M|M d|0~~9999| | ||
| 411 | |L|L d|0~~9999| | ||
| 412 | |F|F d|0~~9999| | ||
| 413 | |B|B h|0~~FFFF| | ||
| 414 | |V|V d|0~~2047| | ||
| 415 | |TC|TC d|0~~9999| | ||
| 416 | |SS|SS d|0~~9999| | ||
| 417 | |SC|SC d|0~~9999| | ||
| 418 | |CS|CS d|0~~9999| | ||
| 419 | |CC|CC d|0~~9999| | ||
| 420 | |SB|SB h|0~~FFFF| | ||
| 421 | |SM|SM d|0~~2047| | ||
| 422 | |STS|STS d|0~~1023| | ||
| 423 | |S|S d|0~~9999| | ||
| 424 | |DX|DX h|0~~FFFF| | ||
| 425 | |DY|DY h|0~~FFFF| | ||
| 426 | |TS|TS d|0~~9999| | ||
| 427 | |Dbit|Dbit d.d|0~~99999.0~~15| | ||
| 428 | |(% colspan="1" rowspan="9" %)Word | ||
| 429 | |W|W h|0~~FFFF| | ||
| 430 | |TN|TN d|0~~99999| | ||
| 431 | |SN|SN d|0~~99999| | ||
| 432 | |CN|CN d|0~~99999| | ||
| 433 | |R|R d|0~~99999| | ||
| 434 | |SW|SW h|0~~FFFF| | ||
| 435 | |Z|Z d|0~~99999| | ||
| 436 | |ZR|ZR h|0~~FFFF| | ||
| 437 | |D|D d|0~~99999| | ||
| 438 | |||
| 439 | **Cable Wiring** | ||
| 440 | |||
| 441 | **RS422** | ||
| 442 | |||
| 443 | [[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_90e38f152d639809.png||alt="image-20220825161612-8.png" height="278" width="612"]] | ||
| 444 | |||
| 445 | [[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_d301e675d8224725.png||alt="image-20220825160820-4.png" height="208" width="359"]] | ||
| 446 | |||
| 447 | == **L02 Ethernet ** == | ||
| 448 | |||
| 449 | Mitsubishi L series CPU built-in Ethernet port. | ||
| 450 | |||
| 451 | **V-BOX Settings** | ||
| 452 | |||
| 453 | |**Items**|**Settings**|**Note** | ||
| 454 | |Protocol|MIT L02 CPU MELSEC| | ||
| 455 | |Connection|Ethernet| | ||
| 456 | |Port No.|1025|Must be the same as the PLC setting | ||
| 457 | |PLC station No.|0|Must be the same as the PLC setting | ||
| 458 | |||
| 459 | (% style="text-align:center" %) | ||
| 460 | [[image:三菱 L02以太网协议配置1.png]] | ||
| 461 | |||
| 462 | **PLC Settings (GX Works2 )** | ||
| 463 | |||
| 464 | Create a project | ||
| 465 | |||
| 466 | Set PLC IP, subnet mask and gateway; | ||
| 467 | |||
| 468 | Select [Binary Code] as communication data code; | ||
| 469 | |||
| 470 | [[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_776e17505f3fc6c0.png?width=600&height=524&rev=1.1||alt="12.PLC Protocol_html_776e17505f3fc6c0.png" height="524" width="600"]] | ||
| 471 | |||
| 472 | Set PLC port number, for example 1025 | ||
| 473 | |||
| 474 | [[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_8d0d1a22d388f70b.png?width=600&height=524&rev=1.1||alt="12.PLC Protocol_html_8d0d1a22d388f70b.png" height="524" width="600"]] | ||
| 475 | |||
| 476 | Save settings; | ||
| 477 | |||
| 478 | Download project into PLC device; | ||
| 479 | |||
| 480 | Restart PLC device; | ||
| 481 | |||
| 482 | **Cable Wiring** | ||
| 483 | |||
| 484 | [[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_2297240b57346b2a.png?width=401&height=170&rev=1.1||alt="12.PLC Protocol_html_2297240b57346b2a.png" height="170" width="401"]] | ||
| 485 | |||
| 486 | == {{id name="HQ12HSerial"/}}**Q12H Serial ** == | ||
| 487 | |||
| 488 | This Demo shows V-BOX communicate with Q12H PLC by Q02H serial Protocol | ||
| 489 | |||
| 490 | **[[Download link>>url:https://ftp.we-con.com.cn/Download/WIKI/PI%20HMI/Demo/Communication/V-Box%20connect%20PLC%20Q12H.rar]]** | ||
| 491 | |||
| 492 | == **QJ71E71 Ethernet ** == | ||
| 493 | |||
| 494 | Mitsubishi QJ71E71 Ethernet communication module; | ||
| 495 | |||
| 496 | **V-BOX Settings** | ||
| 497 | |||
| 498 | |**Items**|**Settings**|**Note** | ||
| 499 | |Protocol|MIT QJ71E71 MELSEC| | ||
| 500 | |Connection|Ethernet| | ||
| 501 | |Port No.|1025|Must be the same as the PLC setting | ||
| 502 | |PLC station No.|0|Must be the same as the PLC setting | ||
| 503 | |||
| 504 | (% style="text-align:center" %) | ||
| 505 | [[image:三菱 QJ71 以太网协议配置.png]] | ||
| 506 | |||
| 507 | **Address List** | ||
| 508 | |||
| 509 | |**Type**|**Device registers**|**Format**|**Range**|**Note** | ||
| 510 | |(% rowspan="18" %)Bit|X|X h|0~~1FFF| | ||
| 511 | |Y|Y h|0~~1FFF| | ||
| 512 | |M|M d|0~~99999| | ||
| 513 | |L|L d|0~~8191| | ||
| 514 | |F|F d|0~~2047| | ||
| 515 | |B|B h|0~~1FFF| | ||
| 516 | |V|V d|0~~2047| | ||
| 517 | |TS|TS d|0~~2047| | ||
| 518 | |TC|TC d|0~~2047| | ||
| 519 | |SS|SS d|0~~2047| | ||
| 520 | |SC|SC d|0~~2047| | ||
| 521 | |CS|CS d|0~~1023| | ||
| 522 | |CC|CC d|0~~1023| | ||
| 523 | |SB|SB h|0~~7FF| | ||
| 524 | |S|S d|0~~8191| | ||
| 525 | |DX|DX h|0~~1FFF| | ||
| 526 | |DY|DY h|0~~1FFF| | ||
| 527 | |SM|SM d|8000~~9999| | ||
| 528 | |(% rowspan="10" %)Word|SD|SD d|0~~2047| | ||
| 529 | |D|D d|0~~12287| | ||
| 530 | |W|W h|0~~1FFF| | ||
| 531 | |TN|TN d|0~~2047| | ||
| 532 | |SN|SN d|0~~2047| | ||
| 533 | |CN|CN d|0~~1023| | ||
| 534 | |R|R d|0~~32767| | ||
| 535 | |SW|SW h|0~~7FF| | ||
| 536 | |Z|Z d|0~~15| | ||
| 537 | |ZR|ZR h|0~~FE7FF| | ||
| 538 | |||
| 539 | **PLC Settings(GX Works2)** | ||
| 540 | |||
| 541 | * Click [Ethernet/CC IE/MELSECNET]; | ||
| 542 | * Please select [Ethernet] as network type; | ||
| 543 | * Set station I/O number according to situation (For example, 0020 means that the module is connected to PLC CPU in first order); | ||
| 544 | * Select [Online] as Mode; | ||
| 545 | * [[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_d54f23688c520f78.png||alt="image-20221119171343-2.png" height="341" width="587"]] | ||
| 546 | * Click [Operation setting] to set IP; | ||
| 547 | * Select [Binary Code] as [Communication Data Code]; | ||
| 548 | * [[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_ce8e6a671b9508e0.png||alt="image-20221119171436-3.png" height="354" width="588"]] | ||
| 549 | * Click [Open setting] | ||
| 550 | * Set protocol: TCP; | ||
| 551 | * Set [unpassive] in [Open system]; | ||
| 552 | * Set [receive] in [Fixed buffer]; | ||
| 553 | * Set [procedure Exist] in [Fixed buffer communication]; | ||
| 554 | * Disable [Pairing open]; | ||
| 555 | * Set [No confirm] in [Existence confirmation]; | ||
| 556 | * Host station port number: 5009; | ||
| 557 | * Save settings; | ||
| 558 | * {{id name="Iimage-20221119171611-4.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_1d8e2f4fb7c72471.png||alt="image-20221119171611-4.png" height="354" width="588"]] | ||
| 559 | * Download project into PLC and restart it | ||
| 560 | |||
| 561 | **Cable Wiring** | ||
| 562 | |||
| 563 | [[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_2297240b57346b2a.png?width=401&height=170&rev=1.1||alt="12.可编程逻辑控制器Protocol_html_2297240b57346b2a.png" height="170" width="401"]] | ||
| 564 | |||
| 565 | == Q03UDV == | ||
| 566 | |||
| 567 | Mitsubishi Q03UDV | ||
| 568 | |||
| 569 | **V-BOX Settings** | ||
| 570 | |||
| 571 | |**Items**|**Settings**|**Note** | ||
| 572 | |Protocol|MIT L02 CPU MELSEC PROTOCOL| | ||
| 573 | |Connection|Ethernet| | ||
| 574 | |Port No.|1025|Must be the same as the PLC setting | ||
| 575 | |PLC station No.|0|Must be the same as the PLC setting | ||
| 576 | |||
| 577 | [[image:1709779590561-640.png]] | ||
| 578 | |||
| 579 | **Address List** | ||
| 580 | |||
| 581 | |**Type**|**Device registers**|**Format**|**Range**|**Note** | ||
| 582 | |(% colspan="1" rowspan="18" %)Bit|X|X h|0~~1fff| | ||
| 583 | |Y|Y h|0~~1fff| | ||
| 584 | |SM|SM d|0~~2047| | ||
| 585 | |M|M d|0~~99999| | ||
| 586 | |L|L d|0~~8191| | ||
| 587 | |F|F d|0~~2047| | ||
| 588 | |V|V d|0~~2047| | ||
| 589 | |B|B h|0~~1fff| | ||
| 590 | |TS|TS d|0~~2047| | ||
| 591 | |TC|TC d|0~~2047| | ||
| 592 | |SS|SS d|0~~2047| | ||
| 593 | |SC|SC d|0~~2047| | ||
| 594 | |CS|CS d|0~~1023| | ||
| 595 | |CC|CC d|0~~1023| | ||
| 596 | |SB|SB h|0~~7ff| | ||
| 597 | |S|S d|0~~8191| | ||
| 598 | |DX|DX h|0~~1fff| | ||
| 599 | |DY|DY h|0~~1fff| | ||
| 600 | |(% colspan="1" rowspan="10" %)Word|SD|SD d|0~~2047| | ||
| 601 | |D|D d|0~~12287| | ||
| 602 | |W|W h|0~~1fff| | ||
| 603 | |TN|TN d|0~~2047| | ||
| 604 | |SN|SN d|0~~2047| | ||
| 605 | |CN|CN d|0~~1023| | ||
| 606 | |SW|SW h|0~~7ff| | ||
| 607 | |Z|Z d|0~~15| | ||
| 608 | |R|R d|0~~32767| | ||
| 609 | |ZR|ZR h|0~~fe7ff| | ||
| 610 | |||
| 611 | (% class="wikigeneratedid" id="HPLCSettings" %) | ||
| 612 | **PLC Settings(GX Works2)** | ||
| 613 | |||
| 614 | (% class="wikigeneratedid" %) | ||
| 615 | PC and PLC connection: | ||
| 616 | |||
| 617 | * Online→Read from PLC | ||
| 618 | |||
| 619 | (% style="text-align:center" %) | ||
| 620 | [[image:1.png]] | ||
| 621 | |||
| 622 | * choose PLC Series→OK | ||
| 623 | |||
| 624 | (% style="text-align:center" %) | ||
| 625 | [[image:StqCG53paq.png]] | ||
| 626 | |||
| 627 | * serial USB→OK | ||
| 628 | |||
| 629 | (% style="text-align:center" %) | ||
| 630 | [[image:Y7H80eq2Eb.png]] | ||
| 631 | |||
| 632 | * Choose Parameter、Global Device Comment and Device Memory→Execute | ||
| 633 | |||
| 634 | (% style="text-align:center" %) | ||
| 635 | [[image:6PAsdFz58I.png]] | ||
| 636 | |||
| 637 | * OK→wait loading successfully→Close | ||
| 638 | |||
| 639 | (% style="text-align:center" %) | ||
| 640 | [[image:0GBGUNn4hQ.png]] | ||
| 641 | |||
| 642 | * Navigation→Parameter→PLC Parameter→IP Address Setting→Built-in Ethernet Port Setting→Host Station(Same as the port on V-box)→End | ||
| 643 | |||
| 644 | (% style="text-align:center" %) | ||
| 645 | [[image:Ypyl4SUHcf.png]] | ||
| 646 | |||
| 647 | * Debug→Start/ Stop Simulation→wait loading successfully→Close | ||
| 648 | |||
| 649 | (% style="text-align:center" %) | ||
| 650 | [[image:ZmUzFbS39y.png]] | ||
| 651 | |||
| 652 | (% style="text-align:center" %) | ||
| 653 | [[image:ehoO3C6bry.png]] | ||