Wiki source code of Mitsubishi

Version 83.3 by Joe on 2024/03/07 10:33

Hide last authors
Theodore Xu 40.1 1 == **FX3U,3G,3GA Serial ** ==
Leo Wei 2.1 2
3 Supported Series: Mitsubishi FX3U, FX3G, FX3GA series
4
Theodore Xu 38.1 5 **V-BOX Settings**
Leo Wei 2.1 6
7 |**Item**|**Settings**|**Note**
8 |Protocol|Mitsubishi FX3U/3G/3GA|
9 |Connection|RS422/RS485/RS232|
10 |Baud rate|9600~~115200|
11 |Data bit|7/8|
12 |Parity|EVEN/Odd/None|
13 |Stop bit|1/2|
14 |PLC station No.|1~~255|
15
Theodore Xu 58.1 16 (% style="text-align:center" %)
17 [[image:三菱 FX3U 串口协议配置.png]]
18
Theodore Xu 38.1 19 **Address List**
Leo Wei 2.1 20
Theodore Xu 67.1 21 |**Type**|**Device registers**|**Format**|**Range**|**Note**
22 |(% rowspan="7" %)Bit|X|Xo|0~~303237|
23 |Y|Y o|0~~303237|
24 |M|M d|0~~99999|
25 |T|T d|0~~99999|
26 |C|C d|0~~99999|
27 |S|S d|0~~99999|
28 |SM|SM d|8000~~9999|
29 |(% rowspan="8" %)Word|X|Xo|0~~303237|
30 |Y|Y o|0~~303237|
31 |M|M d|0~~99999|
32 |T|T d|0~~99999|
33 |C|C d|0~~199|
34 |D|D d|0~~7999|
35 |S|S d|0~~99999|
36 |SD|SD d|8000~~9999|
Leo Wei 2.1 37
Theodore Xu 42.1 38 **PLC Setting**
Leo Wei 2.1 39
Theodore Xu 42.1 40 Open GX Works2, create a new PLC project or open the project that has been created.
41 Create new project: [Project]→[New]→[Series] FXCPU→[Type] FX3G/FX3GC→[OK].
42
43 (% style="text-align:center" %)
Theodore Xu 77.1 44 [[image:GX2.png]]
45
46 (% style="text-align:center" %)
Theodore Xu 42.1 47 [[image:1.2.png]]
48
49 PLC Default Parameters:
50 [Connection type]RS422;[Baud rate]9600, [Data bit]7, [Stop bit]1,[Parity]EVEN; [Station number]0
51 Note:The serial port parameters should be set depending on field requirements
52
53 PC and PLC connection:
54
55 [All connection]→[Connection 1]→[Transfer Setup Connection1]→[Serial USB]→RS-232C: PC and PLC are connected by USB to RS232 adapter,choose corresponding [COM Port]COM 5 →[Transmission speed]9.6Kbps→[setup] →[Parity]EVEN→[Data bits]7→[Stop bits]1→[OK]
56
57 (% style="text-align:center" %)
58 [[image:1.5.1.png]]
59
60 Connection test:when connection is OK,the GX Works2 prompts “Successfully connected with the FX3G/FX3GCCPU.”
61
62 (% style="text-align:center" %)
63 [[image:1.5.2.png]]
64
Theodore Xu 77.1 65 [PLC]→[Write to PLC]→[Online operation]→[Param+program]→[Execute]→[OK]
66
67 (% style="text-align:center" %)
Theodore Xu 78.1 68 [[image:FX3U串口下载.png]]
Theodore Xu 77.1 69
Theodore Xu 42.1 70 **Cable Wiring**
71
Theodore Xu 38.1 72 **RS422**
Leo Wei 2.1 73
Theodore Xu 38.1 74 [[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_1e904556bb758dfe.png||alt="image-20220825103421-5.png" height="296" width="715"]]
Leo Wei 2.1 75
Theodore Xu 38.1 76 [[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_860bcf87f6ca7b98.png||alt="image-20220825100845-4.png" height="246" width="419"]]
Leo Wei 2.1 77
Theodore Xu 43.1 78 == **FX NOPROTOCOL** ==
79
80 Mitsubishi FX3G-RS232-BD
81
82 **V-Box Settings**
83
84 |=**Item**|=**Settings**|=**Note**
85 |Protocol|Mitsubishi FX NOPROTOCOL|
86 |Connection|RS232|
87 |Baud rate|9600|
88 |Data bit|7|
89 |Parity|EVEN|
90 |Stop bit|1|
91 |PLC station No.|0|
92
93 (% style="text-align:center" %)
94 [[image:三菱 FN盒子通讯配置.png]]
95
96 **Address List**
97
Theodore Xu 68.1 98 |=**Type**|=**Device registers**|=**Format**|=**Range**|=**Note**
99 |(% rowspan="8" %)Bit|X|X o|0~~303237|
100 |Y|Y o|0~~303237|
101 |M|M d|0~~99999|
102 |T|T d|0~~99999|
103 |C|C d|0~~99999|
104 |S|S d|0~~99999|
105 |SM|SM d|8000~~9999|
106 |Lamp|Lamp d|0~~0|
107 |(% rowspan="8" %)Word|X|X o|0~~303237|
108 |Y|Y o|0~~303237|
109 |M|M d|0~~99999|
110 |T|T d|0~~99999|
111 |C|C d|0~~199|
112 |D|D d|0~~7999|
113 |S|S d|0~~99999|
114 |SD|SD d|8000~~9999|
Theodore Xu 43.1 115
Theodore Xu 45.1 116 **Cable Wiring**
Theodore Xu 43.1 117
Theodore Xu 44.1 118 [[image:xwiki_PIStudio_12.PLC+protocols_WebHome_1717efe8d969a43c.png]]
119
Theodore Xu 41.1 120 == **FX3U Ethernet ** ==
Leo Wei 2.1 121
122 Supported Modules: FX3U-ENET-ADP, FX3U-ENET-L
123
Theodore Xu 41.1 124 **V-BOX Settings**
Leo Wei 2.1 125
126 |Items|Settings|Note
127 |Protocol|Mitsubishi FX3U|
128 |Connection|Ethernet|
129 |Port No.|5009|Must be the same as the PLC setting
130 |PLC station No.|0|
131
Theodore Xu 60.1 132 (% style="text-align:center" %)
133 [[image:三菱 FX3U 以太网协议配置.png]]
Theodore Xu 57.1 134
Theodore Xu 41.1 135 **Address List**
Leo Wei 2.1 136
Theodore Xu 69.1 137 |**Type**|**Device registers**|**Format**|**Range**|**Note**
138 |(% rowspan="7" %)Bit|X|X OOO|0~~377|
139 |Y|Y OOO|0~~377|
140 |M|M DDDD|0~~7679|
141 |SM|SM DDDD|8000~~8511|
142 |S|S DDDD|0~~4095|
143 |TS|TS DDD|0~~511|
144 |CS|CS DDD|0~~255|
145 |(% rowspan="5" %)Word|CN|CN DDD|0~~199|
146 |TN|TN DDD|0~~511|
147 |D|D DDDD|0~~7999|
148 |SD|SD DDDD|8000~~8511|
149 |R|R DDDDD|0~~32767|
Leo Wei 2.1 150
Theodore Xu 41.1 151 **Ethernet Module Settings**
Leo Wei 2.1 152
153 FX3U-ENET-L module configuration
154 Set up the FX3U-ENET-L Ethernet module settings as follows.
155 Select the module location, which in this document is Module 0.
156
Theodore Xu 41.1 157 [[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_949d5d77c1d9cf1e.png||alt="image-20221116105850-1.png" height="573" width="706"]]
Leo Wei 2.1 158
159 Select "Operational setting" to enter the following screen.
160
161 The Ethernet module IP is set to 192.168.39.254 in this document, and other options are default.
162
Theodore Xu 41.1 163 [[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_dfbfdd586c855c47.png||alt="image-20221116105947-1.png" height="573" width="706"]]
Leo Wei 2.1 164
165 Select "Open setting" to enter the setting interface, the settings are as follows.
166
167 The third item "Protocol" selects TCP, and "Open system" selects MELSOFT connection, which allows the
168
169 Mitsubishi programming software GX works2 to communicate with the FX3U via the Ethernet module.
170
Theodore Xu 41.1 171 [[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_7c01ac15090fcc5b.png||alt="image-20221116110802-1.png" height="549" width="706"]]
Leo Wei 2.1 172
173 Click on "transter setup" - "PC side I/F setting", see the following figure.
174
175 After setting, the first download must use the programming cable, as shown in the figure; after that, can
176
177 use the IP set in the "Ethernet board" to communicate directly with the network cable.
178
Theodore Xu 41.1 179 [[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_d6fd9ce3b96f99e2.png||alt="image-20221116110832-2.png" height="423" width="708"]]
Leo Wei 2.1 180
181 Read and write data from the Ethernet module
182
Theodore Xu 41.1 183 [[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_690b3e57b29cfd4b.png||alt="image-20221116110907-3.png" height="549" width="706"]]
Leo Wei 2.1 184
185 Set "Transter setup" to COM communication, and read or write operation as shown below
186
Theodore Xu 41.1 187 [[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_b317253742f7151.png||alt="image-20221116110917-4.png" height="549" width="706"]]
Leo Wei 2.1 188
Theodore Xu 41.1 189 **PLC Settings (GX Works 2)**
Leo Wei 2.1 190
191 Create a blank FX5U project
192
193 Find Current Connection in the navigation
194
Theodore Xu 41.1 195 [[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_d2a46ba9c005cf38.png||alt="image-20221116111427-1.png" height="421" width="705"]]
Leo Wei 2.1 196
197 Select Connection Channel List
198
199 Select Ethernet board communication
200
Theodore Xu 41.1 201 [[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_8f49721a3e5b0ef9.png||alt="image-20221116111451-2.png" height="421" width="705"]]
Leo Wei 2.1 202
203 Select Ethernet Module
204 Set the IP address of the PLC
205
Theodore Xu 41.1 206 [[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_1e9a9e29a46a1041.png||alt="image-20221116111509-3.png" height="666" width="699"]]
Leo Wei 2.1 207
208 Read or write PLC data, in this document is read
209
210 {{id name="Iimage-20221116111651-4.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_e3d629103727a423.png||alt="image-20221116111651-4.png" height="416" width="697"]]
211
Theodore Xu 41.1 212 [[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_7f29923ebcb670d1.png||alt="image-20221116111727-5.png" height="416" width="697"]]
Leo Wei 2.1 213
Theodore Xu 46.1 214 == **FX5U Serial ** ==
Leo Wei 2.1 215
216 Mitsubishi FX5U series PLC
217
Theodore Xu 46.1 218 **V-BOX Settings**
Leo Wei 2.1 219
220 |**Item**|**Settings**|**Note**
221 |Protocol|Mitsubishi FX5U|
222 |Connection|RS422/RS485|
223 |Baud rate|9600|
224 |Data bit|7|
225 |Parity|Odd|
226 |Stop bit|1|
227 |PLC station No.|1~~255|Need to be the same as PLC settings
228
Theodore Xu 54.1 229 (% style="text-align:center" %)
230 [[image:三菱 FX5U 串口协议配置.png]]
231
Theodore Xu 46.1 232 **Address List**
Leo Wei 2.1 233
Theodore Xu 70.1 234 |**Type**|**Device registers**|**Format**|**Range**|**Note**
235 |(% rowspan="15" %)Bit|X|X o|0~~303237|
236 |Y|Y o|0~~303237|
237 |M|M d|0~~99999|
238 |B|B h|0~~7FFF|
239 |F|F d|0~~32767|
240 |SB|SB h|0~~7FFF|
241 |TS|TS d|0~~1023|
242 |TC|TC d|0~~1023|
243 |STS|STS d|0~~1023|
244 |STC|STS d|0~~1023|
245 |CS|CS d|0~~1023|
246 |CC|CC d|0~~1023|
247 |SM|SM d|0~~9999|
248 |L|L d|0~~32767|
249 |S|S d|0~~4095|
250 |(% rowspan="9" %)Word|W|W h|0~~3FF|
251 |TN|TN d|0~~1023|
252 |STN|STN d|0~~1023|
253 |CN|CN d|0~~1023|
254 |R|R d|0~~32767|
255 |SW|SW h|0~~7FFF|
256 |Z|Z d|0~~23|
257 |D|D d|0~~7999|
258 |SD|SD d|0~~11999|
Leo Wei 2.1 259
Theodore Xu 79.1 260 **PLC Settings **
Leo Wei 2.1 261
262 Create a blank FX5U project
263
Theodore Xu 79.1 264 Open GX Works3, create a new PLC project or open the project that has been created. Create new project: [Project]→[New]→[Series] FX5CPU→[Type] FX5U→[OK].
Leo Wei 2.1 265
Theodore Xu 79.1 266 (% style="text-align:center" %)
267 [[image:GX3.png]]
Leo Wei 2.1 268
269
Theodore Xu 79.1 270 (% style="text-align:center" %)
271 [[image:FX5U 串口选型号.png]]
Leo Wei 2.1 272
Theodore Xu 79.1 273 PLC Default Parameters: 
274 [Navigation]→[Parameter]→[FX5UCPU]→[Module Parameter]→[485 Serial Port]:[Basic Settings] →[ Communication Protocol Type] MC Protocol→[Advanced Settings]:[Baud rate]9600Kbps, [Data Length]7, [Stop bit]1,[Parity]Odd.
Leo Wei 2.1 275
Theodore Xu 79.1 276 (% style="text-align:center" %)
277 [[image:FX5U plc串口参数配置.png]]
Leo Wei 2.1 278
279
Theodore Xu 79.1 280 [Navigation]→[Parameter]→[FX5UCPU]→[Module Parameter]→[485 Serial Port]: [fixed Setting] →[Station No.]0→[Message Pattern] Pattern 1 (X,Y OCT)→[Apply]
Leo Wei 2.1 281
Theodore Xu 79.1 282 {{info}}
283 **✎Note:** The serial port parameters should be set depending on field requirements.
284 {{/info}}
Leo Wei 2.1 285
Theodore Xu 79.1 286 (% style="text-align:center" %)
287 [[image:FX5U plc串口参数.png]]
Leo Wei 2.1 288
Theodore Xu 46.1 289 **Cable Wiring**
Leo Wei 2.1 290
Theodore Xu 46.1 291 **RS422**
Leo Wei 2.1 292
Theodore Xu 80.1 293 [[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_d022c5ff4cf8c68e.png||alt="image-20220825105105-2.png" height="288" width="711"]]
Leo Wei 2.1 294
Theodore Xu 80.1 295 [[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_50e173394c73f154.png||alt="image-20220825105533-3.png" height="246" width="420"]]
Leo Wei 2.1 296
Theodore Xu 33.1 297 == **FX5U Ethernet ** ==
Leo Wei 2.1 298
299 Mitsubishi FX5U series PLC
300
Theodore Xu 59.1 301 **V-BOX Settings**
Leo Wei 2.1 302
303 |**Items**|**Settings**|**Note**
304 |Protocol|Mitsubishi FX5U|
305 |Connection|Ethernet|
306 |Port No.|5002|Must be the same as the PLC setting
307 |PLC station No.|0|
308
Theodore Xu 59.1 309 (% style="text-align:center" %)
310 [[image:三菱 FX5U 以太网协议配置.png]]
Leo Wei 2.1 311
Theodore Xu 59.1 312 **Address List**
313
Theodore Xu 71.1 314 |**Type**|**Device registers**|**Format**|**Range**|**Note**
315 |(% rowspan="15" %)Bit|X|X o|0~~303237|
316 |Y|Y o|0~~303237|
317 |M|M d|0~~99999|
318 |B|B h|0~~7FFF|
319 |F|F d|0~~32767|
320 |SB|SB h|0~~7FFF|
321 |TS|TS d|0~~1023|
322 |TC|TC d|0~~1023|
323 |STS|STS d|0~~1023|
324 |STC|STS d|0~~1023|
325 |CS|CS d|0~~1023|
326 |CC|CC d|0~~1023|
327 |SM|SM d|0~~9999|
328 |L|L d|0~~32767|
329 |S|S d|0~~4095|
330 |(% rowspan="9" %)Word|W|W h|0~~3FF|
331 |TN|TN d|0~~1023|
332 |STN|STN d|0~~1023|
333 |CN|CN d|0~~1023|
334 |R|R d|0~~32767|
335 |SW|SW h|0~~7FFF|
336 |Z|Z d|0~~23|
337 |D|D d|0~~7999|
338 |SD|SD d|0~~11999|
Leo Wei 2.1 339
Theodore Xu 81.1 340 **PLC Settings **
Leo Wei 2.1 341
Theodore Xu 81.1 342 Open GX Works3, create a new PLC project or open the project that has been created.
343
344 Create new project: [Project]→[New]→[Series] FX5CPU→[Type] FX5U→[OK].
345
Theodore Xu 75.2 346 (% style="text-align:center" %)
Theodore Xu 81.1 347 [[image:GX3.png]]
Leo Wei 2.1 348
Theodore Xu 81.1 349 (% style="text-align:center" %)
350 [[image:FX5U 串口选型号.png]]
351
352 PLC Default Parameters: 
353 [Navigation]→[Parameter]→[FX5UCPU]→[Module Parameter]→[Ethernet Port]:[Basic Settings] →[Own node settings]:[IP Address]192.168.40.11, [Subnet Mask]255.255.255.0, [Default Gateway]192.168.40.1,[ Communication Data Code] Binary.
354
355 (% style="text-align:center" %)
356 [[image:FX5U 以太网配置.png]]
357
Theodore Xu 75.2 358 [External Device Configuration]→[Detailed Settings]→[Ethernet Configuration(Built-in Ethernet Port)]→[Ethernet Device (General)]→[SLMP Connection Module] Drag under Host for Connection No.1→[Port No.]5002→[Close with Reflecting the Setting]
Leo Wei 2.1 359
Theodore Xu 75.2 360 (% style="text-align:center" %)
361 [[image:1.3.2.png]]
Leo Wei 2.1 362
Theodore Xu 81.1 363 PC and PLC connection
364
365 [Online]→[Current Connection Destination]→[Direct Coupled Setting]→[Ethernet]→[Adapter] Realtek PCIe GBE Family Controller→[Communication Test]: Successfully connected with the FX5UCPU.
366
367 (% style="text-align:center" %)
368 [[image:FX5U 以太网连接PLC.png]]
369
370 Downloading PLC project
371 [Online]→[Write to PLC]→[Online Data operation]→[Param+program]→[Execute]→[Yes] →[Yes to all]
372
373 (% style="text-align:center" %)
374 [[image:FX5U以太网下载.png]]
375
Theodore Xu 59.1 376 **Cable Wiring**
Leo Wei 2.1 377
Theodore Xu 33.1 378 [[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_2297240b57346b2a.png?width=401&height=170&rev=1.1||alt="12.可编程逻辑控制器Protocol_html_2297240b57346b2a.png" height="170" width="401"]]
Leo Wei 2.1 379
Theodore Xu 47.1 380 == **L02 Serial ** ==
Leo Wei 2.1 381
382 Mitsubishi L02 series CPU built-in serial port.
383
Theodore Xu 47.1 384 **V-BOX Settings**
Leo Wei 2.1 385
386 |**Item**|**Settings**|**Note**
387 |Protocol|Mitsubishi L02|
388 |Connection|RS422|
389 |Baud rate|115200|
390 |Data bit|8|
391 |Parity|Odd|
392 |Stop bit|1|
393 |PLC station No.|1~~255|Need to be the same as PLC settings
394
Theodore Xu 53.1 395 (% style="text-align:center" %)
396 [[image:三菱 L02串口协议配置.png]]
397
Theodore Xu 47.1 398 **Address List**
Leo Wei 2.1 399
Theodore Xu 72.1 400 |**Type**|**Device registers**|**Format**|**Range**|**Note**
Theodore Xu 47.1 401 |(% colspan="1" rowspan="20" %)Bit
Theodore Xu 72.1 402 |X|X h|0~~FFFF|
403 |Y|Y h|0~~FFFF|
404 |M|M d|0~~9999|
405 |L|L d|0~~9999|
406 |F|F d|0~~9999|
407 |B|B h|0~~FFFF|
408 |V|V d|0~~2047|
409 |TC|TC d|0~~9999|
410 |SS|SS d|0~~9999|
411 |SC|SC d|0~~9999|
412 |CS|CS d|0~~9999|
413 |CC|CC d|0~~9999|
414 |SB|SB h|0~~FFFF|
415 |SM|SM d|0~~2047|
416 |STS|STS d|0~~1023|
417 |S|S d|0~~9999|
418 |DX|DX h|0~~FFFF|
419 |DY|DY h|0~~FFFF|
420 |TS|TS d|0~~9999|
421 |Dbit|Dbit d.d|0~~99999.0~~15|
Theodore Xu 47.1 422 |(% colspan="1" rowspan="9" %)Word
Theodore Xu 72.1 423 |W|W h|0~~FFFF|
424 |TN|TN d|0~~99999|
425 |SN|SN d|0~~99999|
426 |CN|CN d|0~~99999|
427 |R|R d|0~~99999|
428 |SW|SW h|0~~FFFF|
429 |Z|Z d|0~~99999|
430 |ZR|ZR h|0~~FFFF|
431 |D|D d|0~~99999|
Leo Wei 2.1 432
Theodore Xu 47.1 433 **Cable Wiring**
Leo Wei 2.1 434
Theodore Xu 47.1 435 **RS422**
Leo Wei 2.1 436
Theodore Xu 47.1 437 [[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_90e38f152d639809.png||alt="image-20220825161612-8.png" height="278" width="612"]]
Leo Wei 2.1 438
Theodore Xu 47.1 439 [[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_d301e675d8224725.png||alt="image-20220825160820-4.png" height="208" width="359"]]
Leo Wei 2.1 440
Theodore Xu 48.1 441 == **L02 Ethernet ** ==
Leo Wei 2.1 442
443 Mitsubishi L series CPU built-in Ethernet port.
444
Theodore Xu 48.1 445 **V-BOX Settings**
Leo Wei 2.1 446
447 |**Items**|**Settings**|**Note**
448 |Protocol|MIT L02 CPU MELSEC|
449 |Connection|Ethernet|
450 |Port No.|1025|Must be the same as the PLC setting
451 |PLC station No.|0|Must be the same as the PLC setting
452
Theodore Xu 52.1 453 (% style="text-align:center" %)
454 [[image:三菱 L02以太网协议配置1.png]]
Theodore Xu 51.1 455
Theodore Xu 48.1 456 **PLC Settings (GX Works2 )**
Leo Wei 2.1 457
458 Create a project
459
460 Set PLC IP, subnet mask and gateway;
461
462 Select [Binary Code] as communication data code;
463
Theodore Xu 49.1 464 [[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_776e17505f3fc6c0.png?width=600&height=524&rev=1.1||alt="12.PLC Protocol_html_776e17505f3fc6c0.png" height="524" width="600"]]
Leo Wei 2.1 465
466 Set PLC port number, for example 1025
467
Theodore Xu 49.1 468 [[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_8d0d1a22d388f70b.png?width=600&height=524&rev=1.1||alt="12.PLC Protocol_html_8d0d1a22d388f70b.png" height="524" width="600"]]
Leo Wei 2.1 469
470 Save settings;
471
472 Download project into PLC device;
473
474 Restart PLC device;
475
Theodore Xu 49.1 476 **Cable Wiring**
Leo Wei 2.1 477
Theodore Xu 49.1 478 [[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_2297240b57346b2a.png?width=401&height=170&rev=1.1||alt="12.PLC Protocol_html_2297240b57346b2a.png" height="170" width="401"]]
Leo Wei 2.1 479
480 == {{id name="HQ12HSerial"/}}**Q12H Serial ** ==
481
482 This Demo shows V-BOX communicate with Q12H PLC by Q02H serial Protocol
483
484 **[[Download link>>url:https://ftp.we-con.com.cn/Download/WIKI/PI%20HMI/Demo/Communication/V-Box%20connect%20PLC%20Q12H.rar]]**
485
Theodore Xu 32.1 486 == **QJ71E71 Ethernet ** ==
Leo Wei 2.1 487
488 Mitsubishi QJ71E71 Ethernet communication module;
489
Theodore Xu 50.1 490 **V-BOX Settings**
Leo Wei 2.1 491
492 |**Items**|**Settings**|**Note**
493 |Protocol|MIT QJ71E71 MELSEC|
494 |Connection|Ethernet|
495 |Port No.|1025|Must be the same as the PLC setting
496 |PLC station No.|0|Must be the same as the PLC setting
497
Theodore Xu 61.1 498 (% style="text-align:center" %)
499 [[image:三菱 QJ71 以太网协议配置.png]]
Leo Wei 2.1 500
Theodore Xu 50.1 501 **Address List**
502
Theodore Xu 74.1 503 |**Type**|**Device registers**|**Format**|**Range**|**Note**
504 |(% rowspan="18" %)Bit|X|X h|0~~1FFF|
505 |Y|Y h|0~~1FFF|
506 |M|M d|0~~99999|
507 |L|L d|0~~8191|
508 |F|F d|0~~2047|
509 |B|B h|0~~1FFF|
510 |V|V d|0~~2047|
511 |TS|TS d|0~~2047|
512 |TC|TC d|0~~2047|
513 |SS|SS d|0~~2047|
514 |SC|SC d|0~~2047|
515 |CS|CS d|0~~1023|
516 |CC|CC d|0~~1023|
517 |SB|SB h|0~~7FF|
518 |S|S d|0~~8191|
519 |DX|DX h|0~~1FFF|
520 |DY|DY h|0~~1FFF|
521 |SM|SM d|8000~~9999|
522 |(% rowspan="10" %)Word|SD|SD d|0~~2047|
523 |D|D d|0~~12287|
524 |W|W h|0~~1FFF|
525 |TN|TN d|0~~2047|
526 |SN|SN d|0~~2047|
527 |CN|CN d|0~~1023|
528 |R|R d|0~~32767|
529 |SW|SW h|0~~7FF|
530 |Z|Z d|0~~15|
531 |ZR|ZR h|0~~FE7FF|
Leo Wei 2.1 532
Theodore Xu 50.1 533 **PLC Settings(GX Works2)**
Leo Wei 2.1 534
535 * Click [Ethernet/CC IE/MELSECNET];
536 * Please select [Ethernet] as network type;
537 * Set station I/O number according to situation (For example, 0020 means that the module is connected to PLC CPU in first order);
538 * Select [Online] as Mode;
Theodore Xu 50.1 539 * [[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_d54f23688c520f78.png||alt="image-20221119171343-2.png" height="341" width="587"]]
Leo Wei 2.1 540 * Click [Operation setting] to set IP;
541 * Select [Binary Code] as [Communication Data Code];
Theodore Xu 50.1 542 * [[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_ce8e6a671b9508e0.png||alt="image-20221119171436-3.png" height="354" width="588"]]
Leo Wei 2.1 543 * Click [Open setting]
544 * Set protocol: TCP;
545 * Set [unpassive] in [Open system];
546 * Set [receive] in [Fixed buffer];
547 * Set [procedure Exist] in [Fixed buffer communication];
548 * Disable [Pairing open];
549 * Set [No confirm] in [Existence confirmation];
550 * Host station port number: 5009;
551 * Save settings;
552 * {{id name="Iimage-20221119171611-4.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_1d8e2f4fb7c72471.png||alt="image-20221119171611-4.png" height="354" width="588"]]
553 * Download project into PLC and restart it
554
Theodore Xu 50.1 555 **Cable Wiring**
Leo Wei 2.1 556
Theodore Xu 34.1 557 [[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_2297240b57346b2a.png?width=401&height=170&rev=1.1||alt="12.可编程逻辑控制器Protocol_html_2297240b57346b2a.png" height="170" width="401"]]
Joe 83.2 558
559 == Q03UDV ==
Joe 83.3 560
561 Mitsubishi Q03UDV
562
563 **V-BOX Settings**
564
565 |**Item**|**Settings**|**Note**
566 |Protocol|Mitsubishi FX3U/3G/3GA|
567 |Connection|RS422/RS485/RS232|
568 |Baud rate|9600~~115200|
569 |Data bit|7/8|
570 |Parity|EVEN/Odd/None|
571 |Stop bit|1/2|
572 |PLC station No.|1~~255