Changes for page Omron

Last modified by Theodore Xu on 2023/09/16 10:47

From version 11.1
edited by Theodore Xu
on 2023/09/12 10:46
Change comment: There is no comment for this version
To version 18.1
edited by Theodore Xu
on 2023/09/15 14:04
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -1,7 +1,5 @@
1 -= **Omron** =
1 += **CP1 Series** =
2 2  
3 -== **CP1 Series** ==
4 -
5 5  [[Download>>url:https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communication%20with%20ORMON%20CP1%20Series.zip]]
6 6  
7 7  == **CP2M Series** ==
... ... @@ -81,18 +81,18 @@
81 81  **PLC setting**
82 82  
83 83  (% class="wikigeneratedid" %)
84 -[PLC]→[Change Communication Settings]→[Network Type] Ethernet→[setting…]→[Derive]→[IPaddress]set the IP address as PLC’s ,192.168.40.99→[Port Number]9600→[OK]→[OK]
82 +[PLC]→[Change Communication Settings]→[Network Type] Ethernet→[setting…]→[Derive]→[IPaddress]set the IP address as PLC’s ,192.168.40.99→[Port Number]9600→[OK]→[OK]
85 85  Note:The IP address of the PLC is displayed on the LED when the PLC is powered up
86 86  
87 87  (% style="text-align:center" %)
88 88  [[image:1.3.1.png]]
89 89  
90 -[PLC]→[Work Online]→USB connection between PC and PLC→The connection prompt appears→[Yes]
88 +[PLC]→[Work Online]→USB connection between PC and PLC→The connection prompt appears→[Yes]
91 91  
92 92  (% style="text-align:center" %)
93 93  [[image:1.3.2.png]]
94 94  
95 -PLC default parameters: [IO Table and Unit Settings] → [Built-in Port/Inner Board] [1500] CJ2M-EIP21→[TCP/IP] → [Transfer [Unit to PC]] → Transfer successfully, click [Close]
93 +PLC default parameters: [IO Table and Unit Settings] → [Built-in Port/Inner Board] [1500] CJ2M-EIP21→[TCP/IP] → [Transfer [Unit to PC]] → Transfer successfully, click [Close]
96 96  
97 97  [IP Address] Use the following address → [IP Address] 192.168.40.99, [Subnet Mask] 255.255.255.0.
98 98  Note: Please configure the IP parameters of PLC according to the field needs
... ... @@ -100,13 +100,13 @@
100 100  (% style="text-align:center" %)
101 101  [[image:1694161978199-503.4.png]]
102 102  
103 -Two rotary coding switches should be set depanding on the program paremeter:
101 +Two rotary coding switches should be set depanding on the program paremeter:
104 104  a) rotary coding switch for unit No. :For example, [Built-in Port/Inner Board] [1500] CJ2M-EIP21(Built In EtherNet/IP Port for CJ2M)(Unit: 0),the rotary coding switch should be dialed to 0
105 105  
106 106  (% style="text-align:center" %)
107 107  [[image:WeCom Screenshot_20230828090604.png]]
108 108  
109 -**b) rotary coding switch for node No. :The high byte 4 of the IP address should be the same as theone configured by the software. such as [IP address] 192.168.40.99. The IP address high byte 4 is 99,rotary coding switch is to use hexadecimal 63 corresponds to decimal 99, node number dialling code 161 corresponds to: 6, 160 corresponds to: 3.Address List**
107 +b) rotary coding switch for node No. :The high byte 4 of the IP address should be the same as theone configured by the software. such as [IP address] 192.168.40.99. The IP address high byte 4 is 99,rotary coding switch is to use hexadecimal 63 corresponds to decimal 99, node number dialling code 161 corresponds to: 6, 160 corresponds to: 3.Address List
110 110  
111 111  (% style="text-align:center" %)
112 112  [[image:WeCom.png]]
... ... @@ -113,13 +113,128 @@
113 113  
114 114  **Cable Wiring**
115 115  
116 -Pin Definition Diagram
117 -
118 118  (% style="text-align:center" %)
119 119  [[image:12.PLC Protocol_html_2297240b57346b2a.png]]
120 120  
121 121  == **CJ2M Serial** ==
122 122  
119 +**V-BOX setting**
120 +
121 +|**Items**|(((
122 +**Settings**
123 +)))
124 +|Protocol|OMRON CV/CJ1M/CS1H
125 +|Connection|RS232/RS485
126 +|Baud rate|9600
127 +|Data bit|7
128 +|Parity|EVEN
129 +|2|2
130 +|PLC station No.|0
131 +
132 +**Device Address:**
133 +
134 +|=Type|=**Device type**|=**Format**|=**Range**|=**Note**
135 +|(% colspan="1" rowspan="23" %)Bit|CIO|DDDDDdd|0 ~~65535.15|I/O and Internal Relay
136 +|W|DDDDDdd|0 ~~65535.15|Hold Relay
137 +|D|DDDDDdd|0 ~~65535.15|Link Relay
138 +|H|DDDDDdd|0 ~~65535.15|
139 +|A|DDDDDdd|0 ~~65535.15|
140 +|TF|DDDDD|0 ~~ 99999|
141 +|CF|DDDDD|0 ~~ 99999|Auxiliary Relay
142 +|T|DDDDDdd|0 ~~65535.15|
143 +|C|DDDDDdd|0 ~~65535.15|
144 +|EM0|DDDDDdd|0 ~~ 99999.15|
145 +|EM1|DDDDDdd|0 ~~ 99999.15|
146 +|EM2|DDDDDdd|0 ~~ 99999.15|
147 +|EM3|DDDDDdd|0 ~~ 99999.15|
148 +|EM4|DDDDDdd|0 ~~ 99999.15|
149 +|EM5|DDDDDdd|0 ~~ 99999.15|
150 +|EM6|DDDDDdd|0 ~~ 99999.15|
151 +|EM7|DDDDDdd|0 ~~ 99999.15|
152 +|EM8|DDDDDdd|0 ~~ 99999.15|
153 +|EM9|DDDDDdd|0 ~~ 99999.15|
154 +|EMA|DDDDDdd|0 ~~ 99999.15|
155 +|EMB|DDDDDdd|0 ~~ 99999.15|
156 +|EMC|DDDDDdd|0 ~~ 99999.15|
157 +|Lamp|D|0~~0|
158 +|(% colspan="1" rowspan="22" %)Word|W|DDDDD|0 ~~ 99999|
159 +|D|DDDDD|0 ~~ 99999|
160 +|H|DDDDD|0 ~~ 99999|
161 +|A|DDDDD|0 ~~ 99999|
162 +|T|DDDDD|0 ~~ 99999|
163 +|C|DDDDD|0 ~~ 99999|
164 +|CIO|DDDDD|0 ~~ 99999|
165 +|EM0|DDDDD|0 ~~ 99999|
166 +|EM1|DDDDD|0 ~~ 99999|
167 +|EM2|DDDDD|0 ~~ 99999|
168 +|EM3|DDDDD|0 ~~ 99999|
169 +|EM4|DDDDD|0 ~~ 99999|
170 +|EM5|DDDDD|0 ~~ 99999|
171 +|EM6|DDDDD|0 ~~ 99999|
172 +|EM7|DDDDD|0 ~~ 99999|
173 +|EM8|DDDDD|0 ~~ 99999|
174 +|EM9|DDDDD|0 ~~ 99999|
175 +|EMA|DDDDD|0 ~~ 99999|
176 +|EMB|DDDDD|0 ~~ 99999|
177 +|EMC|DDDDD|0 ~~ 99999|
178 +|IR|DDDDD|0 ~~ 99999|
179 +|DR|DDDDD|0 ~~ 99999|
180 +
181 +(% style="text-align:center" %)
182 +[[image:CJ2M串口协议配置.png]]
183 +
184 +**PLC Setting:**
185 +
186 +Open cx-programmer, create a new PLC project or open the project that has been created.
187 +Create new project: [File]→[New]→[Device Type]CJ2M→[settings]→[General]→[CPU Type]CPU31→[OK]→[OK].
188 +
189 +(% style="text-align:center" %)
190 +[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_1edc9bf9e8c98170.png]]
191 +
192 +PLC Default Parameters:[Settings]→[Serial Port]→[Communication Settings]→[Standard]9600,1,7,2,E means:[Baud rate] 9600, [Data bits]7, [Stop bits] 2,[Parity] EVEN→[Unit Number]0 →[Mode]Host Link.
193 +
194 +{{info}}
195 +✎Note:The serial port parameters should be set depending on field requirements
196 +{{/info}}
197 +
198 +(% style="text-align:center" %)
199 +[[image:xwiki_PIStudio_12.PLC2.png]]
200 +
201 +[PLC]→[Change Communication Settings]→[Network Type]: PC and PLC are connected by USB cable,choose[USB]→[setting…]→[Network]→[Direct Connection]→[OK]→[OK]
202 +
203 +(% style="text-align:center" %)
204 +[[image:欧姆龙串口连接.png||height="620" width="1163"]]
205 +
206 +[PLC]→[Work Online]→USB connection between PC and PLC→The connection prompt appears→[Yes]
207 +
208 +(% style="text-align:center" %)
209 +[[image:欧姆龙串口在线.png||height="623" width="1070"]]
210 +
211 +[PLC]→[Transfer]→[To PLC]→Select the corresponding download item[OK]→[Yes]→[Yes]
212 +
213 +(% style="text-align:center" %)
214 +[[image:欧姆龙串口下载1.png]]
215 +
216 +**Cable Wiring**
217 +
218 +**RS-485**
219 +
220 +(% style="text-align:center" %)
221 +[[image:欧姆龙串口485.png||height="357" width="519"]]
222 +
223 +**RS-232**
224 +
225 +CPU Port (CPM2A,CQM1/1H,C200H/HS/ALPHA series)
226 +
227 +Communication Module:
228 +
229 +CPM1-CIF01 adapter (for CPM1/CPM1A/CPM2A series, CQM1/CQM1H series) CPM1H-SCB41 communication module (for CQM1H-CPU51/61)
230 +
231 +The serial port pin assignments may vary between HMI models, please click the following link for more information.
232 +
233 +(% style="text-align:center" %)
234 +[[image:欧姆龙串口422.jpg]]
235 +
123 123  == **EC55 Series ** ==
124 124  
125 125  Supported device: EC55 temperature instrument
CJ2M串口协议配置.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.AiXia
Size
... ... @@ -1,0 +1,1 @@
1 +64.7 KB
Content
xwiki_PIStudio_12.PLC+protocols_WebHome_1edc9bf9e8c98170.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.AiXia
Size
... ... @@ -1,0 +1,1 @@
1 +54.3 KB
Content
xwiki_PIStudio_12.PLC2.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.AiXia
Size
... ... @@ -1,0 +1,1 @@
1 +70.2 KB
Content
欧姆龙串口422.jpg
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.AiXia
Size
... ... @@ -1,0 +1,1 @@
1 +18.7 KB
Content
欧姆龙串口485.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.AiXia
Size
... ... @@ -1,0 +1,1 @@
1 +160.2 KB
Content
欧姆龙串口下载.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.AiXia
Size
... ... @@ -1,0 +1,1 @@
1 +462.4 KB
Content
欧姆龙串口下载1.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.AiXia
Size
... ... @@ -1,0 +1,1 @@
1 +462.4 KB
Content
欧姆龙串口在线.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.AiXia
Size
... ... @@ -1,0 +1,1 @@
1 +438.5 KB
Content
欧姆龙串口连接.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.AiXia
Size
... ... @@ -1,0 +1,1 @@
1 +528.0 KB
Content