... ... @@ -81,18 +81,18 @@
81 81  **PLC setting**
82 82  
83 83  (% class="wikigeneratedid" %)
84 -[PLC]→[Change Communication Settings]→[Network Type] Ethernet→[setting…]→[Derive]→[IPaddress]set the IP address as PLC’s ,192.168.40.99→[Port Number]9600→[OK]→[OK]
84 +[PLC]→[Change Communication Settings]→[Network Type] Ethernet→[setting…]→[Derive]→[IPaddress]set the IP address as PLC’s ,192.168.40.99→[Port Number]9600→[OK]→[OK]
85 85  Note:The IP address of the PLC is displayed on the LED when the PLC is powered up
86 86  
87 87  (% style="text-align:center" %)
88 88  [[image:1.3.1.png]]
89 89  
90 -[PLC]→[Work Online]→USB connection between PC and PLC→The connection prompt appears→[Yes]
90 +[PLC]→[Work Online]→USB connection between PC and PLC→The connection prompt appears→[Yes]
91 91  
92 92  (% style="text-align:center" %)
93 93  [[image:1.3.2.png]]
94 94  
95 -PLC default parameters: [IO Table and Unit Settings] → [Built-in Port/Inner Board] [1500] CJ2M-EIP21→[TCP/IP] → [Transfer [Unit to PC]] → Transfer successfully, click [Close]
95 +PLC default parameters: [IO Table and Unit Settings] → [Built-in Port/Inner Board] [1500] CJ2M-EIP21→[TCP/IP] → [Transfer [Unit to PC]] → Transfer successfully, click [Close]
96 96  
97 97  [IP Address] Use the following address → [IP Address] 192.168.40.99, [Subnet Mask] 255.255.255.0.
98 98  Note: Please configure the IP parameters of PLC according to the field needs
... ... @@ -100,13 +100,13 @@
100 100  (% style="text-align:center" %)
101 101  [[image:1694161978199-503.4.png]]
102 102  
103 -Two rotary coding switches should be set depanding on the program paremeter:
103 +Two rotary coding switches should be set depanding on the program paremeter:
104 104  a) rotary coding switch for unit No. :For example, [Built-in Port/Inner Board] [1500] CJ2M-EIP21(Built In EtherNet/IP Port for CJ2M)(Unit: 0),the rotary coding switch should be dialed to 0
105 105  
106 106  (% style="text-align:center" %)
107 107  [[image:WeCom Screenshot_20230828090604.png]]
108 108  
109 -**b) rotary coding switch for node No. :The high byte 4 of the IP address should be the same as theone configured by the software. such as [IP address] 192.168.40.99. The IP address high byte 4 is 99,rotary coding switch is to use hexadecimal 63 corresponds to decimal 99, node number dialling code 161 corresponds to: 6, 160 corresponds to: 3.Address List**
109 +b) rotary coding switch for node No. :The high byte 4 of the IP address should be the same as theone configured by the software. such as [IP address] 192.168.40.99. The IP address high byte 4 is 99,rotary coding switch is to use hexadecimal 63 corresponds to decimal 99, node number dialling code 161 corresponds to: 6, 160 corresponds to: 3.Address List
110 110  
111 111  (% style="text-align:center" %)
112 112  [[image:WeCom.png]]
... ... @@ -113,8 +113,6 @@
113 113  
114 114  **Cable Wiring**
115 115  
116 -Pin Definition Diagram
117 -
118 118  (% style="text-align:center" %)
119 119  [[image:12.PLC Protocol_html_2297240b57346b2a.png]]
120 120  
... ... @@ -135,10 +135,8 @@
135 135  
136 136  **Device Address:**
137 137  
138 -|=**type**|=**Device type**|=**Format**|=**Range**|=**Note**
139 -|=(% colspan="1" rowspan="23" %)(((
140 -B
141 -)))|CIO|DDDDDdd|0 ~~65535.15|I/O and Internal Relay
136 +|=Type|=**Device type**|=**Format**|=**Range**|=**Note**
137 +|(% colspan="1" rowspan="23" %)Bit|CIO|DDDDDdd|0 ~~65535.15|I/O and Internal Relay
142 142  |W|DDDDDdd|0 ~~65535.15|Hold Relay
143 143  |D|DDDDDdd|0 ~~65535.15|Link Relay
144 144  |H|DDDDDdd|0 ~~65535.15|
... ... @@ -190,7 +190,7 @@
190 190  **PLC Setting:**
191 191  
192 192  Open cx-programmer, create a new PLC project or open the project that has been created.
193 -Create new project [File]→[New]→[Device Type]CJ2M→[settings]→[General]→[CPU Type]CPU31→[OK]→[OK].
189 +Create new project: [File]→[New]→[Device Type]CJ2M→[settings]→[General]→[CPU Type]CPU31→[OK]→[OK].
194 194  
195 195  (% style="text-align:center" %)
196 196  [[image:xwiki_PIStudio_12.PLC+protocols_WebHome_1edc9bf9e8c98170.png]]
... ... @@ -204,8 +204,41 @@
204 204  (% style="text-align:center" %)
205 205  [[image:xwiki_PIStudio_12.PLC2.png]]
206 206  
207 -
203 +[PLC]→[Change Communication Settings]→[Network Type]: PC and PLC are connected by USB cable,choose[USB]→[setting…]→[Network]→[Direct Connection]→[OK]→[OK]
208 208  
205 +(% style="text-align:center" %)
206 +[[image:欧姆龙串口连接.png||height="620" width="1163"]]
207 +
208 +[PLC]→[Work Online]→USB connection between PC and PLC→The connection prompt appears→[Yes]
209 +
210 +(% style="text-align:center" %)
211 +[[image:欧姆龙串口在线.png||height="623" width="1070"]]
212 +
213 +[PLC]→[Transfer]→[To PLC]→Select the corresponding download item[OK]→[Yes]→[Yes]
214 +
215 +(% style="text-align:center" %)
216 +[[image:欧姆龙串口下载1.png]]
217 +
218 +**Cable Wiring**
219 +
220 +**RS-485**
221 +
222 +(% style="text-align:center" %)
223 +[[image:欧姆龙串口485.png||height="357" width="519"]]
224 +
225 +**RS-232**
226 +
227 +CPU Port (CPM2A,CQM1/1H,C200H/HS/ALPHA series)
228 +
229 +Communication Module:
230 +
231 +CPM1-CIF01 adapter (for CPM1/CPM1A/CPM2A series, CQM1/CQM1H series) CPM1H-SCB41 communication module (for CQM1H-CPU51/61)
232 +
233 +The serial port pin assignments may vary between HMI models, please click the following link for more information.
234 +
235 +(% style="text-align:center" %)
236 +[[image:欧姆龙串口422.jpg]]
237 +
209 209  == **EC55 Series ** ==
210 210  
211 211  Supported device: EC55 temperature instrument
欧姆龙串口422.jpg
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.AiXia
Size
... ... @@ -1,0 +1,1 @@
1 +18.7 KB
Content
欧姆龙串口485.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.AiXia
Size
... ... @@ -1,0 +1,1 @@
1 +160.2 KB
Content
欧姆龙串口下载.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.AiXia
Size
... ... @@ -1,0 +1,1 @@
1 +462.4 KB
Content
欧姆龙串口下载1.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.AiXia
Size
... ... @@ -1,0 +1,1 @@
1 +462.4 KB
Content
欧姆龙串口在线.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.AiXia
Size
... ... @@ -1,0 +1,1 @@
1 +438.5 KB
Content
欧姆龙串口连接.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.AiXia
Size
... ... @@ -1,0 +1,1 @@
1 +528.0 KB