Changes for page Omron
Last modified by Theodore Xu on 2023/09/16 10:47
From version 12.1
edited by Theodore Xu
on 2023/09/12 11:41
on 2023/09/12 11:41
Change comment:
There is no comment for this version
To version 20.1
edited by Theodore Xu
on 2023/09/16 10:47
on 2023/09/16 10:47
Change comment:
There is no comment for this version
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 6 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -1,5 +3,3 @@ 1 -= **Omron** = 2 - 3 3 == **CP1 Series** == 4 4 5 5 [[Download>>url:https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communication%20with%20ORMON%20CP1%20Series.zip]] ... ... @@ -81,18 +81,18 @@ 81 81 **PLC setting** 82 82 83 83 (% class="wikigeneratedid" %) 84 - ①[PLC]→[Change Communication Settings]→[Network Type] Ethernet→[setting…]→[Derive]→[IPaddress]set the IP address as PLC’s ,192.168.40.99→[Port Number]9600→[OK]→[OK]82 +[PLC]→[Change Communication Settings]→[Network Type] Ethernet→[setting…]→[Derive]→[IPaddress]set the IP address as PLC’s ,192.168.40.99→[Port Number]9600→[OK]→[OK] 85 85 Note:The IP address of the PLC is displayed on the LED when the PLC is powered up 86 86 87 87 (% style="text-align:center" %) 88 88 [[image:1.3.1.png]] 89 89 90 - ②[PLC]→[Work Online]→USB connection between PC and PLC→The connection prompt appears→[Yes]88 +[PLC]→[Work Online]→USB connection between PC and PLC→The connection prompt appears→[Yes] 91 91 92 92 (% style="text-align:center" %) 93 93 [[image:1.3.2.png]] 94 94 95 - ③PLC default parameters: [IO Table and Unit Settings] → [Built-in Port/Inner Board] [1500] CJ2M-EIP21→[TCP/IP] → [Transfer [Unit to PC]] → Transfer successfully, click [Close]93 +PLC default parameters: [IO Table and Unit Settings] → [Built-in Port/Inner Board] [1500] CJ2M-EIP21→[TCP/IP] → [Transfer [Unit to PC]] → Transfer successfully, click [Close] 96 96 97 97 [IP Address] Use the following address → [IP Address] 192.168.40.99, [Subnet Mask] 255.255.255.0. 98 98 Note: Please configure the IP parameters of PLC according to the field needs ... ... @@ -100,13 +100,13 @@ 100 100 (% style="text-align:center" %) 101 101 [[image:1694161978199-503.4.png]] 102 102 103 - ④Two rotary coding switches should be set depanding on the program paremeter:101 +Two rotary coding switches should be set depanding on the program paremeter: 104 104 a) rotary coding switch for unit No. :For example, [Built-in Port/Inner Board] [1500] CJ2M-EIP21(Built In EtherNet/IP Port for CJ2M)(Unit: 0),the rotary coding switch should be dialed to 0 105 105 106 106 (% style="text-align:center" %) 107 107 [[image:WeCom Screenshot_20230828090604.png]] 108 108 109 - **b) rotary coding switch for node No. :The high byte 4 of the IP address should be the same as theone configured by the software. such as [IP address] 192.168.40.99. The IP address high byte 4 is 99,rotary coding switch is to use hexadecimal 63 corresponds to decimal 99, node number dialling code 161 corresponds to: 6, 160 corresponds to: 3.Address List**107 +b) rotary coding switch for node No. :The high byte 4 of the IP address should be the same as theone configured by the software. such as [IP address] 192.168.40.99. The IP address high byte 4 is 99,rotary coding switch is to use hexadecimal 63 corresponds to decimal 99, node number dialling code 161 corresponds to: 6, 160 corresponds to: 3.Address List 110 110 111 111 (% style="text-align:center" %) 112 112 [[image:WeCom.png]] ... ... @@ -113,8 +113,6 @@ 113 113 114 114 **Cable Wiring** 115 115 116 -Pin Definition Diagram 117 - 118 118 (% style="text-align:center" %) 119 119 [[image:12.PLC Protocol_html_2297240b57346b2a.png]] 120 120 ... ... @@ -135,10 +135,8 @@ 135 135 136 136 **Device Address:** 137 137 138 -|=**type**|=**Device type**|=**Format**|=**Range**|=**Note** 139 -|=(% colspan="1" rowspan="23" %)((( 140 -B 141 -)))|CIO|DDDDDdd|0 ~~65535.15|I/O and Internal Relay 134 +|=Type|=**Device type**|=**Format**|=**Range**|=**Note** 135 +|(% colspan="1" rowspan="23" %)Bit|CIO|DDDDDdd|0 ~~65535.15|I/O and Internal Relay 142 142 |W|DDDDDdd|0 ~~65535.15|Hold Relay 143 143 |D|DDDDDdd|0 ~~65535.15|Link Relay 144 144 |H|DDDDDdd|0 ~~65535.15| ... ... @@ -190,7 +190,7 @@ 190 190 **PLC Setting:** 191 191 192 192 Open cx-programmer, create a new PLC project or open the project that has been created. 193 -Create new project :[File]→[New]→[Device Type]CJ2M→[settings]→[General]→[CPU Type]CPU31→[OK]→[OK].187 +Create new project: [File]→[New]→[Device Type]CJ2M→[settings]→[General]→[CPU Type]CPU31→[OK]→[OK]. 194 194 195 195 (% style="text-align:center" %) 196 196 [[image:xwiki_PIStudio_12.PLC+protocols_WebHome_1edc9bf9e8c98170.png]] ... ... @@ -204,13 +204,46 @@ 204 204 (% style="text-align:center" %) 205 205 [[image:xwiki_PIStudio_12.PLC2.png]] 206 206 207 - 201 +[PLC]→[Change Communication Settings]→[Network Type]: PC and PLC are connected by USB cable,choose[USB]→[setting…]→[Network]→[Direct Connection]→[OK]→[OK] 208 208 203 +(% style="text-align:center" %) 204 +[[image:欧姆龙串口连接.png||height="620" width="1163"]] 205 + 206 +[PLC]→[Work Online]→USB connection between PC and PLC→The connection prompt appears→[Yes] 207 + 208 +(% style="text-align:center" %) 209 +[[image:欧姆龙串口在线.png||height="623" width="1070"]] 210 + 211 +[PLC]→[Transfer]→[To PLC]→Select the corresponding download item[OK]→[Yes]→[Yes] 212 + 213 +(% style="text-align:center" %) 214 +[[image:欧姆龙串口下载1.png]] 215 + 216 +**Cable Wiring** 217 + 218 +**RS-485** 219 + 220 +(% style="text-align:center" %) 221 +[[image:欧姆龙串口485.png||height="357" width="519"]] 222 + 223 +**RS-232** 224 + 225 +CPU Port (CPM2A,CQM1/1H,C200H/HS/ALPHA series) 226 + 227 +Communication Module: 228 + 229 +CPM1-CIF01 adapter (for CPM1/CPM1A/CPM2A series, CQM1/CQM1H series) CPM1H-SCB41 communication module (for CQM1H-CPU51/61) 230 + 231 +The serial port pin assignments may vary between HMI models, please click the following link for more information. 232 + 233 +(% style="text-align:center" %) 234 +[[image:欧姆龙串口422.jpg]] 235 + 209 209 == **EC55 Series ** == 210 210 211 211 Supported device: EC55 temperature instrument 212 212 213 -** 1)V-BOX Settings**240 +**V-BOX Settings** 214 214 215 215 |**Items**|**Settings**|**Note** 216 216 |Protocol|Omron EC55| ... ... @@ -218,7 +218,7 @@ 218 218 |Port No.|None| 219 219 |PLC station No.|0| 220 220 221 -** 2)Address List**248 +**Address List** 222 222 223 223 |**Type**|**Register**|**Device range**|**HMI range**|**Function** 224 224 |(% rowspan="3" %)Double word|C0|0-13 (Hex)|0-19|Set read only parameter for area 0 ... ... @@ -231,29 +231,29 @@ 231 231 |CS|-|0-2|Read controller states 232 232 |CA|-|0-17|Action command 233 233 234 -** 3)Device Settings**261 +**Device Settings** 235 235 236 236 Omron E5CC PLC configuration 237 237 238 238 After entering the Communication Settings menu, please set the parameters to the default values for the following table. Press the cycle key of the instrument to enter the next setting. 239 239 240 - {{id name="Ihttps:2F2Fdocs.we-con.com.cn2Fbin2Fdownload2FPIStudio2F12.PLC2520protocols2FWebHome2F12.PLC2520Protocol_html_3d95e093792ba98a.png3Fwidth3D55026height3D22926rev3D1.1"/}}[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_3d95e093792ba98a.png?width=550&height=229&rev=1.1||alt="12.PLC Protocol_html_3d95e093792ba98a.png" height="229" width="550"]]267 +[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_3d95e093792ba98a.png?width=550&height=229&rev=1.1||alt="12.PLC Protocol_html_3d95e093792ba98a.png" height="229" width="550"]] 241 241 242 242 According to PLC configuration and communication port configuration information of the HMI, provide the corresponding steps and configuration screenshots. This configuration needs to communicate properly with the above PLC configuration. The project settings are as follows 243 243 244 - {{id name="Ihttps:2F2Fdocs.we-con.com.cn2Fbin2Fdownload2FPIStudio2F12.PLC2520protocols2FWebHome2F12.PLC2520Protocol_html_be583aa69dd6cf4c.png3Fwidth3D55026height3D24226rev3D1.1"/}}[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_be583aa69dd6cf4c.png?width=550&height=242&rev=1.1||alt="12.PLC Protocol_html_be583aa69dd6cf4c.png" height="242" width="550"]]271 +[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_be583aa69dd6cf4c.png?width=550&height=242&rev=1.1||alt="12.PLC Protocol_html_be583aa69dd6cf4c.png" height="242" width="550"]] 245 245 246 246 **✎Note:** The communication settings for HMI should be consistent with this setting. 247 247 248 -** 4)Configure the communication protocol**275 +**Configure the communication protocol** 249 249 250 - {{id name="Iimage-20220831161041-1.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_24bd1420f057cde5.png||alt="image-20220831161041-1.png" height="712" width="1671"]]277 +[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_24bd1420f057cde5.png||alt="image-20220831161041-1.png" height="712" width="1671"]] 251 251 252 -** 5)Cable Wiring**279 +**Cable Wiring** 253 253 254 - {{id name="Ihttps:2F2Fdocs.we-con.com.cn2Fbin2Fdownload2FPIStudio2F12.PLC2520protocols2FWebHome2F12.PLC2520Protocol_html_5e9a81a14106da9e.png3Fwidth3D39226height3D22326rev3D1.1"/}}[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_5e9a81a14106da9e.png?width=392&height=223&rev=1.1||alt="12.PLC Protocol_html_5e9a81a14106da9e.png" height="223" width="392"]]281 +[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_5e9a81a14106da9e.png?width=392&height=223&rev=1.1||alt="12.PLC Protocol_html_5e9a81a14106da9e.png" height="223" width="392"]] 255 255 256 - {{id name="Ihttps:2F2Fdocs.we-con.com.cn2Fbin2Fdownload2FPIStudio2F12.PLC2520protocols2FWebHome2F12.PLC2520Protocol_html_1897d92be6948d58.png3Fwidth3D39326height3D22326rev3D1.1"/}}[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_1897d92be6948d58.png?width=393&height=223&rev=1.1||alt="12.PLC Protocol_html_1897d92be6948d58.png" height="223" width="393"]]283 +[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_1897d92be6948d58.png?width=393&height=223&rev=1.1||alt="12.PLC Protocol_html_1897d92be6948d58.png" height="223" width="393"]] 257 257 258 258 **✎Note:** 259 259 ... ... @@ -265,4 +265,5 @@ 265 265 * Because of the mechanism problem, this protocol could not support CompoWay/F function that is read-write function of variables in protocol document. 266 266 * When using double-word address, set the data format to 32 bits, otherwise the read/write function is unable. 267 267 * Please set the communication delay time of 10ms in setting, to avoid that the instrument may not be able to communicate in a short time due to too fast data access and too much connection requests. 268 -* {{id name="Iimage-20220831161356-1.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_26911ab93ca27dc7.png||alt="image-20220831161356-1.png" height="456" width="772"]] Because of the particularity of the instrument, it is necessary to write the value of the address in the menu interface corresponding to the address, and to enter the menu where the address locates, so that the value could be written. 295 +* [[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_26911ab93ca27dc7.png||alt="image-20220831161356-1.png" height="456" width="772"]] 296 +* Because of the particularity of the instrument, it is necessary to write the value of the address in the menu interface corresponding to the address, and to enter the menu where the address locates, so that the value could be written.
- 欧姆龙串口422.jpg
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.AiXia - Size
-
... ... @@ -1,0 +1,1 @@ 1 +18.7 KB - Content
- 欧姆龙串口485.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.AiXia - Size
-
... ... @@ -1,0 +1,1 @@ 1 +160.2 KB - Content
- 欧姆龙串口下载.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.AiXia - Size
-
... ... @@ -1,0 +1,1 @@ 1 +462.4 KB - Content
- 欧姆龙串口下载1.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.AiXia - Size
-
... ... @@ -1,0 +1,1 @@ 1 +462.4 KB - Content
- 欧姆龙串口在线.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.AiXia - Size
-
... ... @@ -1,0 +1,1 @@ 1 +438.5 KB - Content
- 欧姆龙串口连接.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.AiXia - Size
-
... ... @@ -1,0 +1,1 @@ 1 +528.0 KB - Content