Changes for page Omron

Last modified by Theodore Xu on 2023/09/16 10:47

From version 13.1
edited by Theodore Xu
on 2023/09/12 11:45
Change comment: There is no comment for this version
To version 18.1
edited by Theodore Xu
on 2023/09/15 14:04
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -1,7 +1,5 @@
1 -= **Omron** =
1 += **CP1 Series** =
2 2  
3 -== **CP1 Series** ==
4 -
5 5  [[Download>>url:https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communication%20with%20ORMON%20CP1%20Series.zip]]
6 6  
7 7  == **CP2M Series** ==
... ... @@ -81,18 +81,18 @@
81 81  **PLC setting**
82 82  
83 83  (% class="wikigeneratedid" %)
84 -[PLC]→[Change Communication Settings]→[Network Type] Ethernet→[setting…]→[Derive]→[IPaddress]set the IP address as PLC’s ,192.168.40.99→[Port Number]9600→[OK]→[OK]
82 +[PLC]→[Change Communication Settings]→[Network Type] Ethernet→[setting…]→[Derive]→[IPaddress]set the IP address as PLC’s ,192.168.40.99→[Port Number]9600→[OK]→[OK]
85 85  Note:The IP address of the PLC is displayed on the LED when the PLC is powered up
86 86  
87 87  (% style="text-align:center" %)
88 88  [[image:1.3.1.png]]
89 89  
90 -[PLC]→[Work Online]→USB connection between PC and PLC→The connection prompt appears→[Yes]
88 +[PLC]→[Work Online]→USB connection between PC and PLC→The connection prompt appears→[Yes]
91 91  
92 92  (% style="text-align:center" %)
93 93  [[image:1.3.2.png]]
94 94  
95 -PLC default parameters: [IO Table and Unit Settings] → [Built-in Port/Inner Board] [1500] CJ2M-EIP21→[TCP/IP] → [Transfer [Unit to PC]] → Transfer successfully, click [Close]
93 +PLC default parameters: [IO Table and Unit Settings] → [Built-in Port/Inner Board] [1500] CJ2M-EIP21→[TCP/IP] → [Transfer [Unit to PC]] → Transfer successfully, click [Close]
96 96  
97 97  [IP Address] Use the following address → [IP Address] 192.168.40.99, [Subnet Mask] 255.255.255.0.
98 98  Note: Please configure the IP parameters of PLC according to the field needs
... ... @@ -100,13 +100,13 @@
100 100  (% style="text-align:center" %)
101 101  [[image:1694161978199-503.4.png]]
102 102  
103 -Two rotary coding switches should be set depanding on the program paremeter:
101 +Two rotary coding switches should be set depanding on the program paremeter:
104 104  a) rotary coding switch for unit No. :For example, [Built-in Port/Inner Board] [1500] CJ2M-EIP21(Built In EtherNet/IP Port for CJ2M)(Unit: 0),the rotary coding switch should be dialed to 0
105 105  
106 106  (% style="text-align:center" %)
107 107  [[image:WeCom Screenshot_20230828090604.png]]
108 108  
109 -**b) rotary coding switch for node No. :The high byte 4 of the IP address should be the same as theone configured by the software. such as [IP address] 192.168.40.99. The IP address high byte 4 is 99,rotary coding switch is to use hexadecimal 63 corresponds to decimal 99, node number dialling code 161 corresponds to: 6, 160 corresponds to: 3.Address List**
107 +b) rotary coding switch for node No. :The high byte 4 of the IP address should be the same as theone configured by the software. such as [IP address] 192.168.40.99. The IP address high byte 4 is 99,rotary coding switch is to use hexadecimal 63 corresponds to decimal 99, node number dialling code 161 corresponds to: 6, 160 corresponds to: 3.Address List
110 110  
111 111  (% style="text-align:center" %)
112 112  [[image:WeCom.png]]
... ... @@ -113,8 +113,6 @@
113 113  
114 114  **Cable Wiring**
115 115  
116 -Pin Definition Diagram
117 -
118 118  (% style="text-align:center" %)
119 119  [[image:12.PLC Protocol_html_2297240b57346b2a.png]]
120 120  
... ... @@ -188,7 +188,7 @@
188 188  **PLC Setting:**
189 189  
190 190  Open cx-programmer, create a new PLC project or open the project that has been created.
191 -Create new project [File]→[New]→[Device Type]CJ2M→[settings]→[General]→[CPU Type]CPU31→[OK]→[OK].
187 +Create new project: [File]→[New]→[Device Type]CJ2M→[settings]→[General]→[CPU Type]CPU31→[OK]→[OK].
192 192  
193 193  (% style="text-align:center" %)
194 194  [[image:xwiki_PIStudio_12.PLC+protocols_WebHome_1edc9bf9e8c98170.png]]
... ... @@ -202,8 +202,41 @@
202 202  (% style="text-align:center" %)
203 203  [[image:xwiki_PIStudio_12.PLC2.png]]
204 204  
205 -
201 +[PLC]→[Change Communication Settings]→[Network Type]: PC and PLC are connected by USB cable,choose[USB]→[setting…]→[Network]→[Direct Connection]→[OK]→[OK]
206 206  
203 +(% style="text-align:center" %)
204 +[[image:欧姆龙串口连接.png||height="620" width="1163"]]
205 +
206 +[PLC]→[Work Online]→USB connection between PC and PLC→The connection prompt appears→[Yes]
207 +
208 +(% style="text-align:center" %)
209 +[[image:欧姆龙串口在线.png||height="623" width="1070"]]
210 +
211 +[PLC]→[Transfer]→[To PLC]→Select the corresponding download item[OK]→[Yes]→[Yes]
212 +
213 +(% style="text-align:center" %)
214 +[[image:欧姆龙串口下载1.png]]
215 +
216 +**Cable Wiring**
217 +
218 +**RS-485**
219 +
220 +(% style="text-align:center" %)
221 +[[image:欧姆龙串口485.png||height="357" width="519"]]
222 +
223 +**RS-232**
224 +
225 +CPU Port (CPM2A,CQM1/1H,C200H/HS/ALPHA series)
226 +
227 +Communication Module:
228 +
229 +CPM1-CIF01 adapter (for CPM1/CPM1A/CPM2A series, CQM1/CQM1H series) CPM1H-SCB41 communication module (for CQM1H-CPU51/61)
230 +
231 +The serial port pin assignments may vary between HMI models, please click the following link for more information.
232 +
233 +(% style="text-align:center" %)
234 +[[image:欧姆龙串口422.jpg]]
235 +
207 207  == **EC55 Series ** ==
208 208  
209 209  Supported device: EC55 temperature instrument
欧姆龙串口422.jpg
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.AiXia
Size
... ... @@ -1,0 +1,1 @@
1 +18.7 KB
Content
欧姆龙串口485.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.AiXia
Size
... ... @@ -1,0 +1,1 @@
1 +160.2 KB
Content
欧姆龙串口下载.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.AiXia
Size
... ... @@ -1,0 +1,1 @@
1 +462.4 KB
Content
欧姆龙串口下载1.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.AiXia
Size
... ... @@ -1,0 +1,1 @@
1 +462.4 KB
Content
欧姆龙串口在线.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.AiXia
Size
... ... @@ -1,0 +1,1 @@
1 +438.5 KB
Content
欧姆龙串口连接.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.AiXia
Size
... ... @@ -1,0 +1,1 @@
1 +528.0 KB
Content