... ... @@ -1,5 +3,3 @@
1 -= **Omron** =
2 -
3 3  == **CP1 Series** ==
4 4  
5 5  [[Download>>url:https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communication%20with%20ORMON%20CP1%20Series.zip]]
... ... @@ -81,18 +81,18 @@
81 81  **PLC setting**
82 82  
83 83  (% class="wikigeneratedid" %)
84 -[PLC]→[Change Communication Settings]→[Network Type] Ethernet→[setting…]→[Derive]→[IPaddress]set the IP address as PLC’s ,192.168.40.99→[Port Number]9600→[OK]→[OK]
82 +[PLC]→[Change Communication Settings]→[Network Type] Ethernet→[setting…]→[Derive]→[IPaddress]set the IP address as PLC’s ,192.168.40.99→[Port Number]9600→[OK]→[OK]
85 85  Note:The IP address of the PLC is displayed on the LED when the PLC is powered up
86 86  
87 87  (% style="text-align:center" %)
88 88  [[image:1.3.1.png]]
89 89  
90 -[PLC]→[Work Online]→USB connection between PC and PLC→The connection prompt appears→[Yes]
88 +[PLC]→[Work Online]→USB connection between PC and PLC→The connection prompt appears→[Yes]
91 91  
92 92  (% style="text-align:center" %)
93 93  [[image:1.3.2.png]]
94 94  
95 -PLC default parameters: [IO Table and Unit Settings] → [Built-in Port/Inner Board] [1500] CJ2M-EIP21→[TCP/IP] → [Transfer [Unit to PC]] → Transfer successfully, click [Close]
93 +PLC default parameters: [IO Table and Unit Settings] → [Built-in Port/Inner Board] [1500] CJ2M-EIP21→[TCP/IP] → [Transfer [Unit to PC]] → Transfer successfully, click [Close]
96 96  
97 97  [IP Address] Use the following address → [IP Address] 192.168.40.99, [Subnet Mask] 255.255.255.0.
98 98  Note: Please configure the IP parameters of PLC according to the field needs
... ... @@ -100,13 +100,13 @@
100 100  (% style="text-align:center" %)
101 101  [[image:1694161978199-503.4.png]]
102 102  
103 -Two rotary coding switches should be set depanding on the program paremeter:
101 +Two rotary coding switches should be set depanding on the program paremeter:
104 104  a) rotary coding switch for unit No. :For example, [Built-in Port/Inner Board] [1500] CJ2M-EIP21(Built In EtherNet/IP Port for CJ2M)(Unit: 0),the rotary coding switch should be dialed to 0
105 105  
106 106  (% style="text-align:center" %)
107 107  [[image:WeCom Screenshot_20230828090604.png]]
108 108  
109 -**b) rotary coding switch for node No. :The high byte 4 of the IP address should be the same as theone configured by the software. such as [IP address] 192.168.40.99. The IP address high byte 4 is 99,rotary coding switch is to use hexadecimal 63 corresponds to decimal 99, node number dialling code 161 corresponds to: 6, 160 corresponds to: 3.Address List**
107 +b) rotary coding switch for node No. :The high byte 4 of the IP address should be the same as theone configured by the software. such as [IP address] 192.168.40.99. The IP address high byte 4 is 99,rotary coding switch is to use hexadecimal 63 corresponds to decimal 99, node number dialling code 161 corresponds to: 6, 160 corresponds to: 3.Address List
110 110  
111 111  (% style="text-align:center" %)
112 112  [[image:WeCom.png]]
... ... @@ -113,8 +113,6 @@
113 113  
114 114  **Cable Wiring**
115 115  
116 -Pin Definition Diagram
117 -
118 118  (% style="text-align:center" %)
119 119  [[image:12.PLC Protocol_html_2297240b57346b2a.png]]
120 120  
... ... @@ -188,7 +188,7 @@
188 188  **PLC Setting:**
189 189  
190 190  Open cx-programmer, create a new PLC project or open the project that has been created.
191 -Create new project [File]→[New]→[Device Type]CJ2M→[settings]→[General]→[CPU Type]CPU31→[OK]→[OK].
187 +Create new project: [File]→[New]→[Device Type]CJ2M→[settings]→[General]→[CPU Type]CPU31→[OK]→[OK].
192 192  
193 193  (% style="text-align:center" %)
194 194  [[image:xwiki_PIStudio_12.PLC+protocols_WebHome_1edc9bf9e8c98170.png]]
... ... @@ -202,13 +202,46 @@
202 202  (% style="text-align:center" %)
203 203  [[image:xwiki_PIStudio_12.PLC2.png]]
204 204  
205 -
201 +[PLC]→[Change Communication Settings]→[Network Type]: PC and PLC are connected by USB cable,choose[USB]→[setting…]→[Network]→[Direct Connection]→[OK]→[OK]
206 206  
203 +(% style="text-align:center" %)
204 +[[image:欧姆龙串口连接.png||height="620" width="1163"]]
205 +
206 +[PLC]→[Work Online]→USB connection between PC and PLC→The connection prompt appears→[Yes]
207 +
208 +(% style="text-align:center" %)
209 +[[image:欧姆龙串口在线.png||height="623" width="1070"]]
210 +
211 +[PLC]→[Transfer]→[To PLC]→Select the corresponding download item[OK]→[Yes]→[Yes]
212 +
213 +(% style="text-align:center" %)
214 +[[image:欧姆龙串口下载1.png]]
215 +
216 +**Cable Wiring**
217 +
218 +**RS-485**
219 +
220 +(% style="text-align:center" %)
221 +[[image:欧姆龙串口485.png||height="357" width="519"]]
222 +
223 +**RS-232**
224 +
225 +CPU Port (CPM2A,CQM1/1H,C200H/HS/ALPHA series)
226 +
227 +Communication Module:
228 +
229 +CPM1-CIF01 adapter (for CPM1/CPM1A/CPM2A series, CQM1/CQM1H series) CPM1H-SCB41 communication module (for CQM1H-CPU51/61)
230 +
231 +The serial port pin assignments may vary between HMI models, please click the following link for more information.
232 +
233 +(% style="text-align:center" %)
234 +[[image:欧姆龙串口422.jpg]]
235 +
207 207  == **EC55 Series ** ==
208 208  
209 209  Supported device: EC55 temperature instrument
210 210  
211 -**1)V-BOX Settings**
240 +**V-BOX Settings**
212 212  
213 213  |**Items**|**Settings**|**Note**
214 214  |Protocol|Omron EC55|
... ... @@ -216,7 +216,7 @@
216 216  |Port No.|None|
217 217  |PLC station No.|0|
218 218  
219 -**2)Address List**
248 +**Address List**
220 220  
221 221  |**Type**|**Register**|**Device range**|**HMI range**|**Function**
222 222  |(% rowspan="3" %)Double word|C0|0-13 (Hex)|0-19|Set read only parameter for area 0
... ... @@ -229,29 +229,29 @@
229 229  |CS|-|0-2|Read controller states
230 230  |CA|-|0-17|Action command
231 231  
232 -**3)Device Settings**
261 +**Device Settings**
233 233  
234 234  Omron E5CC PLC configuration
235 235  
236 236  After entering the Communication Settings menu, please set the parameters to the default values for the following table. Press the cycle key of the instrument to enter the next setting.
237 237  
238 -{{id name="Ihttps:2F2Fdocs.we-con.com.cn2Fbin2Fdownload2FPIStudio2F12.PLC2520protocols2FWebHome2F12.PLC2520Protocol_html_3d95e093792ba98a.png3Fwidth3D55026height3D22926rev3D1.1"/}}[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_3d95e093792ba98a.png?width=550&height=229&rev=1.1||alt="12.PLC Protocol_html_3d95e093792ba98a.png" height="229" width="550"]]
267 +[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_3d95e093792ba98a.png?width=550&height=229&rev=1.1||alt="12.PLC Protocol_html_3d95e093792ba98a.png" height="229" width="550"]]
239 239  
240 240  According to PLC configuration and communication port configuration information of the HMI, provide the corresponding steps and configuration screenshots. This configuration needs to communicate properly with the above PLC configuration. The project settings are as follows
241 241  
242 -{{id name="Ihttps:2F2Fdocs.we-con.com.cn2Fbin2Fdownload2FPIStudio2F12.PLC2520protocols2FWebHome2F12.PLC2520Protocol_html_be583aa69dd6cf4c.png3Fwidth3D55026height3D24226rev3D1.1"/}}[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_be583aa69dd6cf4c.png?width=550&height=242&rev=1.1||alt="12.PLC Protocol_html_be583aa69dd6cf4c.png" height="242" width="550"]]
271 +[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_be583aa69dd6cf4c.png?width=550&height=242&rev=1.1||alt="12.PLC Protocol_html_be583aa69dd6cf4c.png" height="242" width="550"]]
243 243  
244 244  **✎Note:** The communication settings for HMI should be consistent with this setting.
245 245  
246 -**4)Configure the communication protocol**
275 +**Configure the communication protocol**
247 247  
248 -{{id name="Iimage-20220831161041-1.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_24bd1420f057cde5.png||alt="image-20220831161041-1.png" height="712" width="1671"]]
277 +[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_24bd1420f057cde5.png||alt="image-20220831161041-1.png" height="712" width="1671"]]
249 249  
250 -**5)Cable Wiring**
279 +**Cable Wiring**
251 251  
252 -{{id name="Ihttps:2F2Fdocs.we-con.com.cn2Fbin2Fdownload2FPIStudio2F12.PLC2520protocols2FWebHome2F12.PLC2520Protocol_html_5e9a81a14106da9e.png3Fwidth3D39226height3D22326rev3D1.1"/}}[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_5e9a81a14106da9e.png?width=392&height=223&rev=1.1||alt="12.PLC Protocol_html_5e9a81a14106da9e.png" height="223" width="392"]]
281 +[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_5e9a81a14106da9e.png?width=392&height=223&rev=1.1||alt="12.PLC Protocol_html_5e9a81a14106da9e.png" height="223" width="392"]]
253 253  
254 -{{id name="Ihttps:2F2Fdocs.we-con.com.cn2Fbin2Fdownload2FPIStudio2F12.PLC2520protocols2FWebHome2F12.PLC2520Protocol_html_1897d92be6948d58.png3Fwidth3D39326height3D22326rev3D1.1"/}}[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_1897d92be6948d58.png?width=393&height=223&rev=1.1||alt="12.PLC Protocol_html_1897d92be6948d58.png" height="223" width="393"]]
283 +[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_1897d92be6948d58.png?width=393&height=223&rev=1.1||alt="12.PLC Protocol_html_1897d92be6948d58.png" height="223" width="393"]]
255 255  
256 256  **✎Note:**
257 257  
... ... @@ -263,4 +263,5 @@
263 263  * Because of the mechanism problem, this protocol could not support CompoWay/F function that is read-write function of variables in protocol document.
264 264  * When using double-word address, set the data format to 32 bits, otherwise the read/write function is unable.
265 265  * Please set the communication delay time of 10ms in setting, to avoid that the instrument may not be able to communicate in a short time due to too fast data access and too much connection requests.
266 -* {{id name="Iimage-20220831161356-1.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_26911ab93ca27dc7.png||alt="image-20220831161356-1.png" height="456" width="772"]] Because of the particularity of the instrument, it is necessary to write the value of the address in the menu interface corresponding to the address, and to enter the menu where the address locates, so that the value could be written.
295 +* [[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_26911ab93ca27dc7.png||alt="image-20220831161356-1.png" height="456" width="772"]]
296 +* Because of the particularity of the instrument, it is necessary to write the value of the address in the menu interface corresponding to the address, and to enter the menu where the address locates, so that the value could be written.
欧姆龙串口422.jpg
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.AiXia
Size
... ... @@ -1,0 +1,1 @@
1 +18.7 KB
Content
欧姆龙串口485.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.AiXia
Size
... ... @@ -1,0 +1,1 @@
1 +160.2 KB
Content
欧姆龙串口下载.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.AiXia
Size
... ... @@ -1,0 +1,1 @@
1 +462.4 KB
Content
欧姆龙串口下载1.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.AiXia
Size
... ... @@ -1,0 +1,1 @@
1 +462.4 KB
Content
欧姆龙串口在线.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.AiXia
Size
... ... @@ -1,0 +1,1 @@
1 +438.5 KB
Content
欧姆龙串口连接.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.AiXia
Size
... ... @@ -1,0 +1,1 @@
1 +528.0 KB
Content