Changes for page Omron
Last modified by Theodore Xu on 2023/09/16 10:47
From version 16.1
edited by Theodore Xu
on 2023/09/12 14:10
on 2023/09/12 14:10
Change comment:
There is no comment for this version
To version 17.1
edited by Theodore Xu
on 2023/09/12 14:21
on 2023/09/12 14:21
Change comment:
There is no comment for this version
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -81,18 +81,18 @@ 81 81 **PLC setting** 82 82 83 83 (% class="wikigeneratedid" %) 84 - ①[PLC]→[Change Communication Settings]→[Network Type] Ethernet→[setting…]→[Derive]→[IPaddress]set the IP address as PLC’s ,192.168.40.99→[Port Number]9600→[OK]→[OK]84 +[PLC]→[Change Communication Settings]→[Network Type] Ethernet→[setting…]→[Derive]→[IPaddress]set the IP address as PLC’s ,192.168.40.99→[Port Number]9600→[OK]→[OK] 85 85 Note:The IP address of the PLC is displayed on the LED when the PLC is powered up 86 86 87 87 (% style="text-align:center" %) 88 88 [[image:1.3.1.png]] 89 89 90 - ②[PLC]→[Work Online]→USB connection between PC and PLC→The connection prompt appears→[Yes]90 +[PLC]→[Work Online]→USB connection between PC and PLC→The connection prompt appears→[Yes] 91 91 92 92 (% style="text-align:center" %) 93 93 [[image:1.3.2.png]] 94 94 95 - ③PLC default parameters: [IO Table and Unit Settings] → [Built-in Port/Inner Board] [1500] CJ2M-EIP21→[TCP/IP] → [Transfer [Unit to PC]] → Transfer successfully, click [Close]95 +PLC default parameters: [IO Table and Unit Settings] → [Built-in Port/Inner Board] [1500] CJ2M-EIP21→[TCP/IP] → [Transfer [Unit to PC]] → Transfer successfully, click [Close] 96 96 97 97 [IP Address] Use the following address → [IP Address] 192.168.40.99, [Subnet Mask] 255.255.255.0. 98 98 Note: Please configure the IP parameters of PLC according to the field needs ... ... @@ -100,13 +100,13 @@ 100 100 (% style="text-align:center" %) 101 101 [[image:1694161978199-503.4.png]] 102 102 103 - ④Two rotary coding switches should be set depanding on the program paremeter:103 +Two rotary coding switches should be set depanding on the program paremeter: 104 104 a) rotary coding switch for unit No. :For example, [Built-in Port/Inner Board] [1500] CJ2M-EIP21(Built In EtherNet/IP Port for CJ2M)(Unit: 0),the rotary coding switch should be dialed to 0 105 105 106 106 (% style="text-align:center" %) 107 107 [[image:WeCom Screenshot_20230828090604.png]] 108 108 109 - **b) rotary coding switch for node No. :The high byte 4 of the IP address should be the same as theone configured by the software. such as [IP address] 192.168.40.99. The IP address high byte 4 is 99,rotary coding switch is to use hexadecimal 63 corresponds to decimal 99, node number dialling code 161 corresponds to: 6, 160 corresponds to: 3.Address List**109 +b) rotary coding switch for node No. :The high byte 4 of the IP address should be the same as theone configured by the software. such as [IP address] 192.168.40.99. The IP address high byte 4 is 99,rotary coding switch is to use hexadecimal 63 corresponds to decimal 99, node number dialling code 161 corresponds to: 6, 160 corresponds to: 3.Address List 110 110 111 111 (% style="text-align:center" %) 112 112 [[image:WeCom.png]] ... ... @@ -113,8 +113,6 @@ 113 113 114 114 **Cable Wiring** 115 115 116 -Pin Definition Diagram 117 - 118 118 (% style="text-align:center" %) 119 119 [[image:12.PLC Protocol_html_2297240b57346b2a.png]] 120 120