... ... @@ -1,5 +1,7 @@
1 -= **CP1 Series** =
1 += **Omron** =
2 2  
3 +== **CP1 Series** ==
4 +
3 3  [[Download>>url:https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communication%20with%20ORMON%20CP1%20Series.zip]]
4 4  
5 5  == **CP2M Series** ==
... ... @@ -79,18 +79,18 @@
79 79  **PLC setting**
80 80  
81 81  (% class="wikigeneratedid" %)
82 -[PLC]→[Change Communication Settings]→[Network Type] Ethernet→[setting…]→[Derive]→[IPaddress]set the IP address as PLC’s ,192.168.40.99→[Port Number]9600→[OK]→[OK]
84 +[PLC]→[Change Communication Settings]→[Network Type] Ethernet→[setting…]→[Derive]→[IPaddress]set the IP address as PLC’s ,192.168.40.99→[Port Number]9600→[OK]→[OK]
83 83  Note:The IP address of the PLC is displayed on the LED when the PLC is powered up
84 84  
85 85  (% style="text-align:center" %)
86 86  [[image:1.3.1.png]]
87 87  
88 -[PLC]→[Work Online]→USB connection between PC and PLC→The connection prompt appears→[Yes]
90 +[PLC]→[Work Online]→USB connection between PC and PLC→The connection prompt appears→[Yes]
89 89  
90 90  (% style="text-align:center" %)
91 91  [[image:1.3.2.png]]
92 92  
93 -PLC default parameters: [IO Table and Unit Settings] → [Built-in Port/Inner Board] [1500] CJ2M-EIP21→[TCP/IP] → [Transfer [Unit to PC]] → Transfer successfully, click [Close]
95 +PLC default parameters: [IO Table and Unit Settings] → [Built-in Port/Inner Board] [1500] CJ2M-EIP21→[TCP/IP] → [Transfer [Unit to PC]] → Transfer successfully, click [Close]
94 94  
95 95  [IP Address] Use the following address → [IP Address] 192.168.40.99, [Subnet Mask] 255.255.255.0.
96 96  Note: Please configure the IP parameters of PLC according to the field needs
... ... @@ -98,13 +98,13 @@
98 98  (% style="text-align:center" %)
99 99  [[image:1694161978199-503.4.png]]
100 100  
101 -Two rotary coding switches should be set depanding on the program paremeter:
103 +Two rotary coding switches should be set depanding on the program paremeter:
102 102  a) rotary coding switch for unit No. :For example, [Built-in Port/Inner Board] [1500] CJ2M-EIP21(Built In EtherNet/IP Port for CJ2M)(Unit: 0),the rotary coding switch should be dialed to 0
103 103  
104 104  (% style="text-align:center" %)
105 105  [[image:WeCom Screenshot_20230828090604.png]]
106 106  
107 -b) rotary coding switch for node No. :The high byte 4 of the IP address should be the same as theone configured by the software. such as [IP address] 192.168.40.99. The IP address high byte 4 is 99,rotary coding switch is to use hexadecimal 63 corresponds to decimal 99, node number dialling code 161 corresponds to: 6, 160 corresponds to: 3.Address List
109 +**b) rotary coding switch for node No. :The high byte 4 of the IP address should be the same as theone configured by the software. such as [IP address] 192.168.40.99. The IP address high byte 4 is 99,rotary coding switch is to use hexadecimal 63 corresponds to decimal 99, node number dialling code 161 corresponds to: 6, 160 corresponds to: 3.Address List**
108 108  
109 109  (% style="text-align:center" %)
110 110  [[image:WeCom.png]]
... ... @@ -111,6 +111,8 @@
111 111  
112 112  **Cable Wiring**
113 113  
116 +Pin Definition Diagram
117 +
114 114  (% style="text-align:center" %)
115 115  [[image:12.PLC Protocol_html_2297240b57346b2a.png]]
116 116