Changes for page Omron

Last modified by Theodore Xu on 2023/09/16 10:47

From version 18.1
edited by Theodore Xu
on 2023/09/15 14:04
Change comment: There is no comment for this version
To version 8.1
edited by Theodore Xu
on 2023/09/08 16:35
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -1,5 +1,7 @@
1 -= **CP1 Series** =
1 += **Omron** =
2 2  
3 +== **CP1 Series** ==
4 +
3 3  [[Download>>url:https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communication%20with%20ORMON%20CP1%20Series.zip]]
4 4  
5 5  == **CP2M Series** ==
... ... @@ -6,7 +6,7 @@
6 6  
7 7  [[Download>>url:https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communication%20with%20ORMON%20CJ2M.zip]]
8 8  
9 -== **CJ2M Ethemet** ==
11 +== **CJ TCP FINS Ethemet** ==
10 10  
11 11  Supported device:CJ series, CJ1W-EIP21,CJ2M-EIP21
12 12  
... ... @@ -22,7 +22,7 @@
22 22  (% style="text-align:center" %)
23 23  [[image:欧姆龙创建.png]]
24 24  
25 -**Address List **
27 +**2)Address List **
26 26  
27 27  |=**Type**|=**Device registers**|=**HMI registers**|=**Format**|=**Range**|=**Note**
28 28  |(% colspan="1" rowspan="23" %)Bit
... ... @@ -76,21 +76,21 @@
76 76  |DR|DR|DR d|0~~99999|
77 77  
78 78  (% class="wikigeneratedid" %)
79 -**PLC setting**
81 +**3)PLC software**
80 80  
81 81  (% class="wikigeneratedid" %)
82 -[PLC]→[Change Communication Settings]→[Network Type] Ethernet→[setting…]→[Derive]→[IPaddress]set the IP address as PLC’s ,192.168.40.99→[Port Number]9600→[OK]→[OK]
84 +[PLC]→[Change Communication Settings]→[Network Type] Ethernet→[setting…]→[Derive]→[IPaddress]set the IP address as PLC’s ,192.168.40.99→[Port Number]9600→[OK]→[OK]
83 83  Note:The IP address of the PLC is displayed on the LED when the PLC is powered up
84 84  
85 85  (% style="text-align:center" %)
86 86  [[image:1.3.1.png]]
87 87  
88 -[PLC]→[Work Online]→USB connection between PC and PLC→The connection prompt appears→[Yes]
90 +[PLC]→[Work Online]→USB connection between PC and PLC→The connection prompt appears→[Yes]
89 89  
90 90  (% style="text-align:center" %)
91 91  [[image:1.3.2.png]]
92 92  
93 -PLC default parameters: [IO Table and Unit Settings] → [Built-in Port/Inner Board] [1500] CJ2M-EIP21→[TCP/IP] → [Transfer [Unit to PC]] → Transfer successfully, click [Close]
95 +PLC default parameters: [IO Table and Unit Settings] → [Built-in Port/Inner Board] [1500] CJ2M-EIP21→[TCP/IP] → [Transfer [Unit to PC]] → Transfer successfully, click [Close]
94 94  
95 95  [IP Address] Use the following address → [IP Address] 192.168.40.99, [Subnet Mask] 255.255.255.0.
96 96  Note: Please configure the IP parameters of PLC according to the field needs
... ... @@ -98,141 +98,24 @@
98 98  (% style="text-align:center" %)
99 99  [[image:1694161978199-503.4.png]]
100 100  
101 -Two rotary coding switches should be set depanding on the program paremeter:
103 +Two rotary coding switches should be set depanding on the program paremeter:
102 102  a) rotary coding switch for unit No. :For example, [Built-in Port/Inner Board] [1500] CJ2M-EIP21(Built In EtherNet/IP Port for CJ2M)(Unit: 0),the rotary coding switch should be dialed to 0
103 103  
104 104  (% style="text-align:center" %)
105 105  [[image:WeCom Screenshot_20230828090604.png]]
106 106  
107 -b) rotary coding switch for node No. :The high byte 4 of the IP address should be the same as theone configured by the software. such as [IP address] 192.168.40.99. The IP address high byte 4 is 99,rotary coding switch is to use hexadecimal 63 corresponds to decimal 99, node number dialling code 161 corresponds to: 6, 160 corresponds to: 3.Address List
109 +**b) rotary coding switch for node No. :The high byte 4 of the IP address should be the same as theone configured by the software. such as [IP address] 192.168.40.99. The IP address high byte 4 is 99,rotary coding switch is to use hexadecimal 63 corresponds to decimal 99, node number dialling code 161 corresponds to: 6, 160 corresponds to: 3.Address List**
108 108  
109 109  (% style="text-align:center" %)
110 110  [[image:WeCom.png]]
111 111  
112 -**Cable Wiring**
114 +**4)Cable Wiring**
113 113  
116 +Pin Definition Diagram
117 +
114 114  (% style="text-align:center" %)
115 115  [[image:12.PLC Protocol_html_2297240b57346b2a.png]]
116 116  
117 -== **CJ2M Serial** ==
118 -
119 -**V-BOX setting**
120 -
121 -|**Items**|(((
122 -**Settings**
123 -)))
124 -|Protocol|OMRON CV/CJ1M/CS1H
125 -|Connection|RS232/RS485
126 -|Baud rate|9600
127 -|Data bit|7
128 -|Parity|EVEN
129 -|2|2
130 -|PLC station No.|0
131 -
132 -**Device Address:**
133 -
134 -|=Type|=**Device type**|=**Format**|=**Range**|=**Note**
135 -|(% colspan="1" rowspan="23" %)Bit|CIO|DDDDDdd|0 ~~65535.15|I/O and Internal Relay
136 -|W|DDDDDdd|0 ~~65535.15|Hold Relay
137 -|D|DDDDDdd|0 ~~65535.15|Link Relay
138 -|H|DDDDDdd|0 ~~65535.15|
139 -|A|DDDDDdd|0 ~~65535.15|
140 -|TF|DDDDD|0 ~~ 99999|
141 -|CF|DDDDD|0 ~~ 99999|Auxiliary Relay
142 -|T|DDDDDdd|0 ~~65535.15|
143 -|C|DDDDDdd|0 ~~65535.15|
144 -|EM0|DDDDDdd|0 ~~ 99999.15|
145 -|EM1|DDDDDdd|0 ~~ 99999.15|
146 -|EM2|DDDDDdd|0 ~~ 99999.15|
147 -|EM3|DDDDDdd|0 ~~ 99999.15|
148 -|EM4|DDDDDdd|0 ~~ 99999.15|
149 -|EM5|DDDDDdd|0 ~~ 99999.15|
150 -|EM6|DDDDDdd|0 ~~ 99999.15|
151 -|EM7|DDDDDdd|0 ~~ 99999.15|
152 -|EM8|DDDDDdd|0 ~~ 99999.15|
153 -|EM9|DDDDDdd|0 ~~ 99999.15|
154 -|EMA|DDDDDdd|0 ~~ 99999.15|
155 -|EMB|DDDDDdd|0 ~~ 99999.15|
156 -|EMC|DDDDDdd|0 ~~ 99999.15|
157 -|Lamp|D|0~~0|
158 -|(% colspan="1" rowspan="22" %)Word|W|DDDDD|0 ~~ 99999|
159 -|D|DDDDD|0 ~~ 99999|
160 -|H|DDDDD|0 ~~ 99999|
161 -|A|DDDDD|0 ~~ 99999|
162 -|T|DDDDD|0 ~~ 99999|
163 -|C|DDDDD|0 ~~ 99999|
164 -|CIO|DDDDD|0 ~~ 99999|
165 -|EM0|DDDDD|0 ~~ 99999|
166 -|EM1|DDDDD|0 ~~ 99999|
167 -|EM2|DDDDD|0 ~~ 99999|
168 -|EM3|DDDDD|0 ~~ 99999|
169 -|EM4|DDDDD|0 ~~ 99999|
170 -|EM5|DDDDD|0 ~~ 99999|
171 -|EM6|DDDDD|0 ~~ 99999|
172 -|EM7|DDDDD|0 ~~ 99999|
173 -|EM8|DDDDD|0 ~~ 99999|
174 -|EM9|DDDDD|0 ~~ 99999|
175 -|EMA|DDDDD|0 ~~ 99999|
176 -|EMB|DDDDD|0 ~~ 99999|
177 -|EMC|DDDDD|0 ~~ 99999|
178 -|IR|DDDDD|0 ~~ 99999|
179 -|DR|DDDDD|0 ~~ 99999|
180 -
181 -(% style="text-align:center" %)
182 -[[image:CJ2M串口协议配置.png]]
183 -
184 -**PLC Setting:**
185 -
186 -Open cx-programmer, create a new PLC project or open the project that has been created.
187 -Create new project: [File]→[New]→[Device Type]CJ2M→[settings]→[General]→[CPU Type]CPU31→[OK]→[OK].
188 -
189 -(% style="text-align:center" %)
190 -[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_1edc9bf9e8c98170.png]]
191 -
192 -PLC Default Parameters:[Settings]→[Serial Port]→[Communication Settings]→[Standard]9600,1,7,2,E means:[Baud rate] 9600, [Data bits]7, [Stop bits] 2,[Parity] EVEN→[Unit Number]0 →[Mode]Host Link.
193 -
194 -{{info}}
195 -✎Note:The serial port parameters should be set depending on field requirements
196 -{{/info}}
197 -
198 -(% style="text-align:center" %)
199 -[[image:xwiki_PIStudio_12.PLC2.png]]
200 -
201 -[PLC]→[Change Communication Settings]→[Network Type]: PC and PLC are connected by USB cable,choose[USB]→[setting…]→[Network]→[Direct Connection]→[OK]→[OK]
202 -
203 -(% style="text-align:center" %)
204 -[[image:欧姆龙串口连接.png||height="620" width="1163"]]
205 -
206 -[PLC]→[Work Online]→USB connection between PC and PLC→The connection prompt appears→[Yes]
207 -
208 -(% style="text-align:center" %)
209 -[[image:欧姆龙串口在线.png||height="623" width="1070"]]
210 -
211 -[PLC]→[Transfer]→[To PLC]→Select the corresponding download item[OK]→[Yes]→[Yes]
212 -
213 -(% style="text-align:center" %)
214 -[[image:欧姆龙串口下载1.png]]
215 -
216 -**Cable Wiring**
217 -
218 -**RS-485**
219 -
220 -(% style="text-align:center" %)
221 -[[image:欧姆龙串口485.png||height="357" width="519"]]
222 -
223 -**RS-232**
224 -
225 -CPU Port (CPM2A,CQM1/1H,C200H/HS/ALPHA series)
226 -
227 -Communication Module:
228 -
229 -CPM1-CIF01 adapter (for CPM1/CPM1A/CPM2A series, CQM1/CQM1H series) CPM1H-SCB41 communication module (for CQM1H-CPU51/61)
230 -
231 -The serial port pin assignments may vary between HMI models, please click the following link for more information.
232 -
233 -(% style="text-align:center" %)
234 -[[image:欧姆龙串口422.jpg]]
235 -
236 236  == **EC55 Series ** ==
237 237  
238 238  Supported device: EC55 temperature instrument
CJ2M串口协议配置.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.AiXia
Size
... ... @@ -1,1 +1,0 @@
1 -64.7 KB
Content
xwiki_PIStudio_12.PLC+protocols_WebHome_1edc9bf9e8c98170.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.AiXia
Size
... ... @@ -1,1 +1,0 @@
1 -54.3 KB
Content
xwiki_PIStudio_12.PLC2.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.AiXia
Size
... ... @@ -1,1 +1,0 @@
1 -70.2 KB
Content
欧姆龙串口422.jpg
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.AiXia
Size
... ... @@ -1,1 +1,0 @@
1 -18.7 KB
Content
欧姆龙串口485.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.AiXia
Size
... ... @@ -1,1 +1,0 @@
1 -160.2 KB
Content
欧姆龙串口下载.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.AiXia
Size
... ... @@ -1,1 +1,0 @@
1 -462.4 KB
Content
欧姆龙串口下载1.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.AiXia
Size
... ... @@ -1,1 +1,0 @@
1 -462.4 KB
Content
欧姆龙串口在线.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.AiXia
Size
... ... @@ -1,1 +1,0 @@
1 -438.5 KB
Content
欧姆龙串口连接.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.AiXia
Size
... ... @@ -1,1 +1,0 @@
1 -528.0 KB
Content