Changes for page Omron
Last modified by Theodore Xu on 2023/09/16 10:47
From version 19.1
edited by Theodore Xu
on 2023/09/16 10:46
on 2023/09/16 10:46
Change comment:
There is no comment for this version
To version 16.1
edited by Theodore Xu
on 2023/09/12 14:10
on 2023/09/12 14:10
Change comment:
There is no comment for this version
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -1,3 +1,5 @@ 1 += **Omron** = 2 + 1 1 == **CP1 Series** == 2 2 3 3 [[Download>>url:https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communication%20with%20ORMON%20CP1%20Series.zip]] ... ... @@ -79,18 +79,18 @@ 79 79 **PLC setting** 80 80 81 81 (% class="wikigeneratedid" %) 82 -[PLC]→[Change Communication Settings]→[Network Type] Ethernet→[setting…]→[Derive]→[IPaddress]set the IP address as PLC’s ,192.168.40.99→[Port Number]9600→[OK]→[OK] 84 +①[PLC]→[Change Communication Settings]→[Network Type] Ethernet→[setting…]→[Derive]→[IPaddress]set the IP address as PLC’s ,192.168.40.99→[Port Number]9600→[OK]→[OK] 83 83 Note:The IP address of the PLC is displayed on the LED when the PLC is powered up 84 84 85 85 (% style="text-align:center" %) 86 86 [[image:1.3.1.png]] 87 87 88 -[PLC]→[Work Online]→USB connection between PC and PLC→The connection prompt appears→[Yes] 90 +②[PLC]→[Work Online]→USB connection between PC and PLC→The connection prompt appears→[Yes] 89 89 90 90 (% style="text-align:center" %) 91 91 [[image:1.3.2.png]] 92 92 93 -PLC default parameters: [IO Table and Unit Settings] → [Built-in Port/Inner Board] [1500] CJ2M-EIP21→[TCP/IP] → [Transfer [Unit to PC]] → Transfer successfully, click [Close] 95 +③PLC default parameters: [IO Table and Unit Settings] → [Built-in Port/Inner Board] [1500] CJ2M-EIP21→[TCP/IP] → [Transfer [Unit to PC]] → Transfer successfully, click [Close] 94 94 95 95 [IP Address] Use the following address → [IP Address] 192.168.40.99, [Subnet Mask] 255.255.255.0. 96 96 Note: Please configure the IP parameters of PLC according to the field needs ... ... @@ -98,13 +98,13 @@ 98 98 (% style="text-align:center" %) 99 99 [[image:1694161978199-503.4.png]] 100 100 101 -Two rotary coding switches should be set depanding on the program paremeter: 103 +④Two rotary coding switches should be set depanding on the program paremeter: 102 102 a) rotary coding switch for unit No. :For example, [Built-in Port/Inner Board] [1500] CJ2M-EIP21(Built In EtherNet/IP Port for CJ2M)(Unit: 0),the rotary coding switch should be dialed to 0 103 103 104 104 (% style="text-align:center" %) 105 105 [[image:WeCom Screenshot_20230828090604.png]] 106 106 107 -b) rotary coding switch for node No. :The high byte 4 of the IP address should be the same as theone configured by the software. such as [IP address] 192.168.40.99. The IP address high byte 4 is 99,rotary coding switch is to use hexadecimal 63 corresponds to decimal 99, node number dialling code 161 corresponds to: 6, 160 corresponds to: 3.Address List 109 +**b) rotary coding switch for node No. :The high byte 4 of the IP address should be the same as theone configured by the software. such as [IP address] 192.168.40.99. The IP address high byte 4 is 99,rotary coding switch is to use hexadecimal 63 corresponds to decimal 99, node number dialling code 161 corresponds to: 6, 160 corresponds to: 3.Address List** 108 108 109 109 (% style="text-align:center" %) 110 110 [[image:WeCom.png]] ... ... @@ -111,6 +111,8 @@ 111 111 112 112 **Cable Wiring** 113 113 116 +Pin Definition Diagram 117 + 114 114 (% style="text-align:center" %) 115 115 [[image:12.PLC Protocol_html_2297240b57346b2a.png]] 116 116