Changes for page Omron
Last modified by Theodore Xu on 2023/09/16 10:47
From version 4.1
edited by Leo Wei
on 2023/08/24 14:11
on 2023/08/24 14:11
Change comment:
There is no comment for this version
To version 18.1
edited by Theodore Xu
on 2023/09/15 14:04
on 2023/09/15 14:04
Change comment:
There is no comment for this version
Summary
-
Page properties (2 modified, 0 added, 0 removed)
-
Attachments (0 modified, 16 added, 0 removed)
- 1.3.1.png
- 1.3.2.png
- 12.PLC Protocol_html_2297240b57346b2a.png
- 1694161978199-503.4.png
- CJ2M串口协议配置.png
- WeCom Screenshot_20230828090604.png
- WeCom.png
- xwiki_PIStudio_12.PLC+protocols_WebHome_1edc9bf9e8c98170.png
- xwiki_PIStudio_12.PLC2.png
- 欧姆龙串口422.jpg
- 欧姆龙串口485.png
- 欧姆龙串口下载.png
- 欧姆龙串口下载1.png
- 欧姆龙串口在线.png
- 欧姆龙串口连接.png
- 欧姆龙创建.png
Details
- Page properties
-
- Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki. admin1 +XWiki.AiXia - Content
-
... ... @@ -1,15 +1,240 @@ 1 -= {{idname="HOmron"/}}**Omron**=1 += **CP1 Series** = 2 2 3 -== {{id name="HCP1Series"/}}**CP1 Series** == 4 - 5 5 [[Download>>url:https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communication%20with%20ORMON%20CP1%20Series.zip]] 6 6 7 -== {{id name="HCP2MSeries"/}}**CP2M Series** ==5 +== **CP2M Series** == 8 8 9 9 [[Download>>url:https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communication%20with%20ORMON%20CJ2M.zip]] 10 10 11 -== {{id name="HEC55Series"/}}**EC55Series** ==9 +== **CJ2M Ethemet** == 12 12 11 +Supported device:CJ series, CJ1W-EIP21,CJ2M-EIP21 12 + 13 +**V-Box Settings** 14 + 15 +|=**Items**|=**Settings** 16 +|Protocol|OMRON CJ TCP FINS Ethemet 17 +|Connection|Ethernet 18 +|Port No.|9600 19 +|Device No.|0 20 +|V-Box No.|0 21 + 22 +(% style="text-align:center" %) 23 +[[image:欧姆龙创建.png]] 24 + 25 +**Address List ** 26 + 27 +|=**Type**|=**Device registers**|=**HMI registers**|=**Format**|=**Range**|=**Note** 28 +|(% colspan="1" rowspan="23" %)Bit 29 + |CIO|CIO|CIO d|0~~99999| 30 +|W|W|W d|0~~99999| 31 +|D|D|D d|0~~99999| 32 +|H|H|H d|0~~99999| 33 +|A|A|A d|0~~99999| 34 +|T|T|T h|0~~99999| 35 +|CF|CF|CF d|0~~99999| 36 +|FF|FF|FF d|0~~99999| 37 +|C|C|C d|0~~99999| 38 +|EM0|EM0|EM0 d|0~~99999| 39 +|EM1|EM1|EM1 d|0~~99999| 40 +|EM2|EM2|EM2 d|0~~99999| 41 +|EM3|EM3|EM3 d|0~~99999| 42 +|EM4|EM4|EM4 d|0~~99999| 43 +|EM5|EM5|EM5 h|0~~99999| 44 +|EM6|EM6|EM6 d|0~~99999| 45 +|EM7|EM7|EM7 d|0~~99999| 46 +|EM8|EM8|EM8 d|0~~99999| 47 +|EM9|EM9|EM9 d|0~~99999| 48 +|EMA|EMA|EMA d|0~~99999| 49 +|EMB|EMB|EMB d|0~~99999| 50 +|EMC|EMC|EMC d|0~~99999| 51 +|Lamp|Lamp|Lamp d|0~~0| 52 +|(% colspan="1" rowspan="24" %)Word 53 + |CIO|CIO|CIO d|0~~99999| 54 +|W|W|W d|0~~99999| 55 +|D|D|D d|0~~99999| 56 +|H|H|H d|0~~99999| 57 +|A|A|A d|0~~99999| 58 +|T|T|T h|0~~99999| 59 +|CF|CF|CF d|0~~99999| 60 +|FF|FF|FF d|0~~99999| 61 +|C|C|C d|0~~99999| 62 +|EM0|EM0|EM0 d|0~~99999| 63 +|EM1|EM1|EM1 d|0~~99999| 64 +|EM2|EM2|EM2 d|0~~99999| 65 +|EM3|EM3|EM3 d|0~~99999| 66 +|EM4|EM4|EM4 d|0~~99999| 67 +|EM5|EM5|EM5 h|0~~99999| 68 +|EM6|EM6|EM6 d|0~~99999| 69 +|EM7|EM7|EM7 d|0~~99999| 70 +|EM8|EM8|EM8 d|0~~99999| 71 +|EM9|EM9|EM9 d|0~~99999| 72 +|EMA|EMA|EMA d|0~~99999| 73 +|EMB|EMB|EMB d|0~~99999| 74 +|EMC|EMC|EMC d|0~~99999| 75 +|IR|IR|IR d|0~~99999| 76 +|DR|DR|DR d|0~~99999| 77 + 78 +(% class="wikigeneratedid" %) 79 +**PLC setting** 80 + 81 +(% class="wikigeneratedid" %) 82 +[PLC]→[Change Communication Settings]→[Network Type] Ethernet→[setting…]→[Derive]→[IPaddress]set the IP address as PLC’s ,192.168.40.99→[Port Number]9600→[OK]→[OK] 83 +Note:The IP address of the PLC is displayed on the LED when the PLC is powered up 84 + 85 +(% style="text-align:center" %) 86 +[[image:1.3.1.png]] 87 + 88 +[PLC]→[Work Online]→USB connection between PC and PLC→The connection prompt appears→[Yes] 89 + 90 +(% style="text-align:center" %) 91 +[[image:1.3.2.png]] 92 + 93 +PLC default parameters: [IO Table and Unit Settings] → [Built-in Port/Inner Board] [1500] CJ2M-EIP21→[TCP/IP] → [Transfer [Unit to PC]] → Transfer successfully, click [Close] 94 + 95 +[IP Address] Use the following address → [IP Address] 192.168.40.99, [Subnet Mask] 255.255.255.0. 96 +Note: Please configure the IP parameters of PLC according to the field needs 97 + 98 +(% style="text-align:center" %) 99 +[[image:1694161978199-503.4.png]] 100 + 101 +Two rotary coding switches should be set depanding on the program paremeter: 102 +a) rotary coding switch for unit No. :For example, [Built-in Port/Inner Board] [1500] CJ2M-EIP21(Built In EtherNet/IP Port for CJ2M)(Unit: 0),the rotary coding switch should be dialed to 0 103 + 104 +(% style="text-align:center" %) 105 +[[image:WeCom Screenshot_20230828090604.png]] 106 + 107 +b) rotary coding switch for node No. :The high byte 4 of the IP address should be the same as theone configured by the software. such as [IP address] 192.168.40.99. The IP address high byte 4 is 99,rotary coding switch is to use hexadecimal 63 corresponds to decimal 99, node number dialling code 161 corresponds to: 6, 160 corresponds to: 3.Address List 108 + 109 +(% style="text-align:center" %) 110 +[[image:WeCom.png]] 111 + 112 +**Cable Wiring** 113 + 114 +(% style="text-align:center" %) 115 +[[image:12.PLC Protocol_html_2297240b57346b2a.png]] 116 + 117 +== **CJ2M Serial** == 118 + 119 +**V-BOX setting** 120 + 121 +|**Items**|((( 122 +**Settings** 123 +))) 124 +|Protocol|OMRON CV/CJ1M/CS1H 125 +|Connection|RS232/RS485 126 +|Baud rate|9600 127 +|Data bit|7 128 +|Parity|EVEN 129 +|2|2 130 +|PLC station No.|0 131 + 132 +**Device Address:** 133 + 134 +|=Type|=**Device type**|=**Format**|=**Range**|=**Note** 135 +|(% colspan="1" rowspan="23" %)Bit|CIO|DDDDDdd|0 ~~65535.15|I/O and Internal Relay 136 +|W|DDDDDdd|0 ~~65535.15|Hold Relay 137 +|D|DDDDDdd|0 ~~65535.15|Link Relay 138 +|H|DDDDDdd|0 ~~65535.15| 139 +|A|DDDDDdd|0 ~~65535.15| 140 +|TF|DDDDD|0 ~~ 99999| 141 +|CF|DDDDD|0 ~~ 99999|Auxiliary Relay 142 +|T|DDDDDdd|0 ~~65535.15| 143 +|C|DDDDDdd|0 ~~65535.15| 144 +|EM0|DDDDDdd|0 ~~ 99999.15| 145 +|EM1|DDDDDdd|0 ~~ 99999.15| 146 +|EM2|DDDDDdd|0 ~~ 99999.15| 147 +|EM3|DDDDDdd|0 ~~ 99999.15| 148 +|EM4|DDDDDdd|0 ~~ 99999.15| 149 +|EM5|DDDDDdd|0 ~~ 99999.15| 150 +|EM6|DDDDDdd|0 ~~ 99999.15| 151 +|EM7|DDDDDdd|0 ~~ 99999.15| 152 +|EM8|DDDDDdd|0 ~~ 99999.15| 153 +|EM9|DDDDDdd|0 ~~ 99999.15| 154 +|EMA|DDDDDdd|0 ~~ 99999.15| 155 +|EMB|DDDDDdd|0 ~~ 99999.15| 156 +|EMC|DDDDDdd|0 ~~ 99999.15| 157 +|Lamp|D|0~~0| 158 +|(% colspan="1" rowspan="22" %)Word|W|DDDDD|0 ~~ 99999| 159 +|D|DDDDD|0 ~~ 99999| 160 +|H|DDDDD|0 ~~ 99999| 161 +|A|DDDDD|0 ~~ 99999| 162 +|T|DDDDD|0 ~~ 99999| 163 +|C|DDDDD|0 ~~ 99999| 164 +|CIO|DDDDD|0 ~~ 99999| 165 +|EM0|DDDDD|0 ~~ 99999| 166 +|EM1|DDDDD|0 ~~ 99999| 167 +|EM2|DDDDD|0 ~~ 99999| 168 +|EM3|DDDDD|0 ~~ 99999| 169 +|EM4|DDDDD|0 ~~ 99999| 170 +|EM5|DDDDD|0 ~~ 99999| 171 +|EM6|DDDDD|0 ~~ 99999| 172 +|EM7|DDDDD|0 ~~ 99999| 173 +|EM8|DDDDD|0 ~~ 99999| 174 +|EM9|DDDDD|0 ~~ 99999| 175 +|EMA|DDDDD|0 ~~ 99999| 176 +|EMB|DDDDD|0 ~~ 99999| 177 +|EMC|DDDDD|0 ~~ 99999| 178 +|IR|DDDDD|0 ~~ 99999| 179 +|DR|DDDDD|0 ~~ 99999| 180 + 181 +(% style="text-align:center" %) 182 +[[image:CJ2M串口协议配置.png]] 183 + 184 +**PLC Setting:** 185 + 186 +Open cx-programmer, create a new PLC project or open the project that has been created. 187 +Create new project: [File]→[New]→[Device Type]CJ2M→[settings]→[General]→[CPU Type]CPU31→[OK]→[OK]. 188 + 189 +(% style="text-align:center" %) 190 +[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_1edc9bf9e8c98170.png]] 191 + 192 +PLC Default Parameters:[Settings]→[Serial Port]→[Communication Settings]→[Standard]9600,1,7,2,E means:[Baud rate] 9600, [Data bits]7, [Stop bits] 2,[Parity] EVEN→[Unit Number]0 →[Mode]Host Link. 193 + 194 +{{info}} 195 +✎Note:The serial port parameters should be set depending on field requirements 196 +{{/info}} 197 + 198 +(% style="text-align:center" %) 199 +[[image:xwiki_PIStudio_12.PLC2.png]] 200 + 201 +[PLC]→[Change Communication Settings]→[Network Type]: PC and PLC are connected by USB cable,choose[USB]→[setting…]→[Network]→[Direct Connection]→[OK]→[OK] 202 + 203 +(% style="text-align:center" %) 204 +[[image:欧姆龙串口连接.png||height="620" width="1163"]] 205 + 206 +[PLC]→[Work Online]→USB connection between PC and PLC→The connection prompt appears→[Yes] 207 + 208 +(% style="text-align:center" %) 209 +[[image:欧姆龙串口在线.png||height="623" width="1070"]] 210 + 211 +[PLC]→[Transfer]→[To PLC]→Select the corresponding download item[OK]→[Yes]→[Yes] 212 + 213 +(% style="text-align:center" %) 214 +[[image:欧姆龙串口下载1.png]] 215 + 216 +**Cable Wiring** 217 + 218 +**RS-485** 219 + 220 +(% style="text-align:center" %) 221 +[[image:欧姆龙串口485.png||height="357" width="519"]] 222 + 223 +**RS-232** 224 + 225 +CPU Port (CPM2A,CQM1/1H,C200H/HS/ALPHA series) 226 + 227 +Communication Module: 228 + 229 +CPM1-CIF01 adapter (for CPM1/CPM1A/CPM2A series, CQM1/CQM1H series) CPM1H-SCB41 communication module (for CQM1H-CPU51/61) 230 + 231 +The serial port pin assignments may vary between HMI models, please click the following link for more information. 232 + 233 +(% style="text-align:center" %) 234 +[[image:欧姆龙串口422.jpg]] 235 + 236 +== **EC55 Series ** == 237 + 13 13 Supported device: EC55 temperature instrument 14 14 15 15 **1)V-BOX Settings**
- 1.3.1.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.AiXia - Size
-
... ... @@ -1,0 +1,1 @@ 1 +74.9 KB - Content
- 1.3.2.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.AiXia - Size
-
... ... @@ -1,0 +1,1 @@ 1 +67.7 KB - Content
- 12.PLC Protocol_html_2297240b57346b2a.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.AiXia - Size
-
... ... @@ -1,0 +1,1 @@ 1 +107.1 KB - Content
- 1694161978199-503.4.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.AiXia - Size
-
... ... @@ -1,0 +1,1 @@ 1 +94.6 KB - Content
- CJ2M串口协议配置.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.AiXia - Size
-
... ... @@ -1,0 +1,1 @@ 1 +64.7 KB - Content
- WeCom Screenshot_20230828090604.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.AiXia - Size
-
... ... @@ -1,0 +1,1 @@ 1 +40.2 KB - Content
- WeCom.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.AiXia - Size
-
... ... @@ -1,0 +1,1 @@ 1 +40.2 KB - Content
- xwiki_PIStudio_12.PLC+protocols_WebHome_1edc9bf9e8c98170.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.AiXia - Size
-
... ... @@ -1,0 +1,1 @@ 1 +54.3 KB - Content
- xwiki_PIStudio_12.PLC2.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.AiXia - Size
-
... ... @@ -1,0 +1,1 @@ 1 +70.2 KB - Content
- 欧姆龙串口422.jpg
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.AiXia - Size
-
... ... @@ -1,0 +1,1 @@ 1 +18.7 KB - Content
- 欧姆龙串口485.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.AiXia - Size
-
... ... @@ -1,0 +1,1 @@ 1 +160.2 KB - Content
- 欧姆龙串口下载.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.AiXia - Size
-
... ... @@ -1,0 +1,1 @@ 1 +462.4 KB - Content
- 欧姆龙串口下载1.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.AiXia - Size
-
... ... @@ -1,0 +1,1 @@ 1 +462.4 KB - Content
- 欧姆龙串口在线.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.AiXia - Size
-
... ... @@ -1,0 +1,1 @@ 1 +438.5 KB - Content
- 欧姆龙串口连接.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.AiXia - Size
-
... ... @@ -1,0 +1,1 @@ 1 +528.0 KB - Content
- 欧姆龙创建.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.AiXia - Size
-
... ... @@ -1,0 +1,1 @@ 1 +65.8 KB - Content