Changes for page Omron
Last modified by Theodore Xu on 2023/09/16 10:47
From version 4.1
edited by Leo Wei
on 2023/08/24 14:11
on 2023/08/24 14:11
Change comment:
There is no comment for this version
To version 9.1
edited by Theodore Xu
on 2023/09/11 17:55
on 2023/09/11 17:55
Change comment:
There is no comment for this version
Summary
-
Page properties (2 modified, 0 added, 0 removed)
-
Attachments (0 modified, 7 added, 0 removed)
Details
- Page properties
-
- Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki. admin1 +XWiki.AiXia - Content
-
... ... @@ -1,15 +1,125 @@ 1 -= {{id name="HOmron"/}}**Omron** =1 += **Omron** = 2 2 3 -== {{id name="HCP1Series"/}}**CP1 Series** ==3 +== **CP1 Series** == 4 4 5 5 [[Download>>url:https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communication%20with%20ORMON%20CP1%20Series.zip]] 6 6 7 -== {{id name="HCP2MSeries"/}}**CP2M Series** ==7 +== **CP2M Series** == 8 8 9 9 [[Download>>url:https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communication%20with%20ORMON%20CJ2M.zip]] 10 10 11 -== {{id name="HEC55Series"/}}**EC55Series** ==11 +== **CJ TCP FINS Ethemet** == 12 12 13 +Supported device:CJ series, CJ1W-EIP21,CJ2M-EIP21 14 + 15 +**V-Box Settings** 16 + 17 +|=**Items**|=**Settings** 18 +|Protocol|OMRON CJ TCP FINS Ethemet 19 +|Connection|Ethernet 20 +|Port No.|9600 21 +|Device No.|0 22 +|V-Box No.|0 23 + 24 +(% style="text-align:center" %) 25 +[[image:欧姆龙创建.png]] 26 + 27 +**Address List ** 28 + 29 +|=**Type**|=**Device registers**|=**HMI registers**|=**Format**|=**Range**|=**Note** 30 +|(% colspan="1" rowspan="23" %)Bit 31 + |CIO|CIO|CIO d|0~~99999| 32 +|W|W|W d|0~~99999| 33 +|D|D|D d|0~~99999| 34 +|H|H|H d|0~~99999| 35 +|A|A|A d|0~~99999| 36 +|T|T|T h|0~~99999| 37 +|CF|CF|CF d|0~~99999| 38 +|FF|FF|FF d|0~~99999| 39 +|C|C|C d|0~~99999| 40 +|EM0|EM0|EM0 d|0~~99999| 41 +|EM1|EM1|EM1 d|0~~99999| 42 +|EM2|EM2|EM2 d|0~~99999| 43 +|EM3|EM3|EM3 d|0~~99999| 44 +|EM4|EM4|EM4 d|0~~99999| 45 +|EM5|EM5|EM5 h|0~~99999| 46 +|EM6|EM6|EM6 d|0~~99999| 47 +|EM7|EM7|EM7 d|0~~99999| 48 +|EM8|EM8|EM8 d|0~~99999| 49 +|EM9|EM9|EM9 d|0~~99999| 50 +|EMA|EMA|EMA d|0~~99999| 51 +|EMB|EMB|EMB d|0~~99999| 52 +|EMC|EMC|EMC d|0~~99999| 53 +|Lamp|Lamp|Lamp d|0~~0| 54 +|(% colspan="1" rowspan="24" %)Word 55 + |CIO|CIO|CIO d|0~~99999| 56 +|W|W|W d|0~~99999| 57 +|D|D|D d|0~~99999| 58 +|H|H|H d|0~~99999| 59 +|A|A|A d|0~~99999| 60 +|T|T|T h|0~~99999| 61 +|CF|CF|CF d|0~~99999| 62 +|FF|FF|FF d|0~~99999| 63 +|C|C|C d|0~~99999| 64 +|EM0|EM0|EM0 d|0~~99999| 65 +|EM1|EM1|EM1 d|0~~99999| 66 +|EM2|EM2|EM2 d|0~~99999| 67 +|EM3|EM3|EM3 d|0~~99999| 68 +|EM4|EM4|EM4 d|0~~99999| 69 +|EM5|EM5|EM5 h|0~~99999| 70 +|EM6|EM6|EM6 d|0~~99999| 71 +|EM7|EM7|EM7 d|0~~99999| 72 +|EM8|EM8|EM8 d|0~~99999| 73 +|EM9|EM9|EM9 d|0~~99999| 74 +|EMA|EMA|EMA d|0~~99999| 75 +|EMB|EMB|EMB d|0~~99999| 76 +|EMC|EMC|EMC d|0~~99999| 77 +|IR|IR|IR d|0~~99999| 78 +|DR|DR|DR d|0~~99999| 79 + 80 +(% class="wikigeneratedid" %) 81 +**PLC setting** 82 + 83 +(% class="wikigeneratedid" %) 84 +①[PLC]→[Change Communication Settings]→[Network Type] Ethernet→[setting…]→[Derive]→[IPaddress]set the IP address as PLC’s ,192.168.40.99→[Port Number]9600→[OK]→[OK] 85 +Note:The IP address of the PLC is displayed on the LED when the PLC is powered up 86 + 87 +(% style="text-align:center" %) 88 +[[image:1.3.1.png]] 89 + 90 +②[PLC]→[Work Online]→USB connection between PC and PLC→The connection prompt appears→[Yes] 91 + 92 +(% style="text-align:center" %) 93 +[[image:1.3.2.png]] 94 + 95 +③PLC default parameters: [IO Table and Unit Settings] → [Built-in Port/Inner Board] [1500] CJ2M-EIP21→[TCP/IP] → [Transfer [Unit to PC]] → Transfer successfully, click [Close] 96 + 97 +[IP Address] Use the following address → [IP Address] 192.168.40.99, [Subnet Mask] 255.255.255.0. 98 +Note: Please configure the IP parameters of PLC according to the field needs 99 + 100 +(% style="text-align:center" %) 101 +[[image:1694161978199-503.4.png]] 102 + 103 +④Two rotary coding switches should be set depanding on the program paremeter: 104 +a) rotary coding switch for unit No. :For example, [Built-in Port/Inner Board] [1500] CJ2M-EIP21(Built In EtherNet/IP Port for CJ2M)(Unit: 0),the rotary coding switch should be dialed to 0 105 + 106 +(% style="text-align:center" %) 107 +[[image:WeCom Screenshot_20230828090604.png]] 108 + 109 +**b) rotary coding switch for node No. :The high byte 4 of the IP address should be the same as theone configured by the software. such as [IP address] 192.168.40.99. The IP address high byte 4 is 99,rotary coding switch is to use hexadecimal 63 corresponds to decimal 99, node number dialling code 161 corresponds to: 6, 160 corresponds to: 3.Address List** 110 + 111 +(% style="text-align:center" %) 112 +[[image:WeCom.png]] 113 + 114 +**Cable Wiring** 115 + 116 +Pin Definition Diagram 117 + 118 +(% style="text-align:center" %) 119 +[[image:12.PLC Protocol_html_2297240b57346b2a.png]] 120 + 121 +== **EC55 Series ** == 122 + 13 13 Supported device: EC55 temperature instrument 14 14 15 15 **1)V-BOX Settings**
- 1.3.1.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.AiXia - Size
-
... ... @@ -1,0 +1,1 @@ 1 +74.9 KB - Content
- 1.3.2.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.AiXia - Size
-
... ... @@ -1,0 +1,1 @@ 1 +67.7 KB - Content
- 12.PLC Protocol_html_2297240b57346b2a.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.AiXia - Size
-
... ... @@ -1,0 +1,1 @@ 1 +107.1 KB - Content
- 1694161978199-503.4.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.AiXia - Size
-
... ... @@ -1,0 +1,1 @@ 1 +94.6 KB - Content
- WeCom Screenshot_20230828090604.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.AiXia - Size
-
... ... @@ -1,0 +1,1 @@ 1 +40.2 KB - Content
- WeCom.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.AiXia - Size
-
... ... @@ -1,0 +1,1 @@ 1 +40.2 KB - Content
- 欧姆龙创建.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.AiXia - Size
-
... ... @@ -1,0 +1,1 @@ 1 +65.8 KB - Content