Changes for page Omron
Last modified by Theodore Xu on 2023/09/16 10:47
From version 6.1
edited by Theodore Xu
on 2023/09/08 16:28
on 2023/09/08 16:28
Change comment:
There is no comment for this version
To version 8.1
edited by Theodore Xu
on 2023/09/08 16:35
on 2023/09/08 16:35
Change comment:
There is no comment for this version
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 7 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -26,7 +26,6 @@ 26 26 27 27 **2)Address List ** 28 28 29 - 30 30 |=**Type**|=**Device registers**|=**HMI registers**|=**Format**|=**Range**|=**Note** 31 31 |(% colspan="1" rowspan="23" %)Bit 32 32 |CIO|CIO|CIO d|0~~99999| ... ... @@ -85,6 +85,40 @@ 85 85 ①[PLC]→[Change Communication Settings]→[Network Type] Ethernet→[setting…]→[Derive]→[IPaddress]set the IP address as PLC’s ,192.168.40.99→[Port Number]9600→[OK]→[OK] 86 86 Note:The IP address of the PLC is displayed on the LED when the PLC is powered up 87 87 87 +(% style="text-align:center" %) 88 +[[image:1.3.1.png]] 89 + 90 +②[PLC]→[Work Online]→USB connection between PC and PLC→The connection prompt appears→[Yes] 91 + 92 +(% style="text-align:center" %) 93 +[[image:1.3.2.png]] 94 + 95 +③PLC default parameters: [IO Table and Unit Settings] → [Built-in Port/Inner Board] [1500] CJ2M-EIP21→[TCP/IP] → [Transfer [Unit to PC]] → Transfer successfully, click [Close] 96 + 97 +[IP Address] Use the following address → [IP Address] 192.168.40.99, [Subnet Mask] 255.255.255.0. 98 +Note: Please configure the IP parameters of PLC according to the field needs 99 + 100 +(% style="text-align:center" %) 101 +[[image:1694161978199-503.4.png]] 102 + 103 +④Two rotary coding switches should be set depanding on the program paremeter: 104 +a) rotary coding switch for unit No. :For example, [Built-in Port/Inner Board] [1500] CJ2M-EIP21(Built In EtherNet/IP Port for CJ2M)(Unit: 0),the rotary coding switch should be dialed to 0 105 + 106 +(% style="text-align:center" %) 107 +[[image:WeCom Screenshot_20230828090604.png]] 108 + 109 +**b) rotary coding switch for node No. :The high byte 4 of the IP address should be the same as theone configured by the software. such as [IP address] 192.168.40.99. The IP address high byte 4 is 99,rotary coding switch is to use hexadecimal 63 corresponds to decimal 99, node number dialling code 161 corresponds to: 6, 160 corresponds to: 3.Address List** 110 + 111 +(% style="text-align:center" %) 112 +[[image:WeCom.png]] 113 + 114 +**4)Cable Wiring** 115 + 116 +Pin Definition Diagram 117 + 118 +(% style="text-align:center" %) 119 +[[image:12.PLC Protocol_html_2297240b57346b2a.png]] 120 + 88 88 == **EC55 Series ** == 89 89 90 90 Supported device: EC55 temperature instrument
- 1.3.1.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.AiXia - Size
-
... ... @@ -1,0 +1,1 @@ 1 +74.9 KB - Content
- 1.3.2.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.AiXia - Size
-
... ... @@ -1,0 +1,1 @@ 1 +67.7 KB - Content
- 12.PLC Protocol_html_2297240b57346b2a.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.AiXia - Size
-
... ... @@ -1,0 +1,1 @@ 1 +107.1 KB - Content
- 1694161978199-503.4.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.AiXia - Size
-
... ... @@ -1,0 +1,1 @@ 1 +94.6 KB - Content
- WeCom Screenshot_20230828090604.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.AiXia - Size
-
... ... @@ -1,0 +1,1 @@ 1 +40.2 KB - Content
- WeCom.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.AiXia - Size
-
... ... @@ -1,0 +1,1 @@ 1 +40.2 KB - Content
- 欧姆龙创建.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.AiXia - Size
-
... ... @@ -1,0 +1,1 @@ 1 +65.8 KB - Content