Changes for page Omron
Last modified by Theodore Xu on 2023/09/16 10:47
From version 7.1
edited by Theodore Xu
on 2023/09/08 16:29
on 2023/09/08 16:29
Change comment:
There is no comment for this version
To version 12.1
edited by Theodore Xu
on 2023/09/12 11:41
on 2023/09/12 11:41
Change comment:
There is no comment for this version
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 9 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -8,7 +8,7 @@ 8 8 9 9 [[Download>>url:https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communication%20with%20ORMON%20CJ2M.zip]] 10 10 11 -== **CJ TCP FINSEthemet** ==11 +== **CJ2M Ethemet** == 12 12 13 13 Supported device:CJ series, CJ1W-EIP21,CJ2M-EIP21 14 14 ... ... @@ -24,9 +24,8 @@ 24 24 (% style="text-align:center" %) 25 25 [[image:欧姆龙创建.png]] 26 26 27 -** 2)Address List **27 +**Address List ** 28 28 29 - 30 30 |=**Type**|=**Device registers**|=**HMI registers**|=**Format**|=**Range**|=**Note** 31 31 |(% colspan="1" rowspan="23" %)Bit 32 32 |CIO|CIO|CIO d|0~~99999| ... ... @@ -79,17 +79,134 @@ 79 79 |DR|DR|DR d|0~~99999| 80 80 81 81 (% class="wikigeneratedid" %) 82 -** 3)PLC software**81 +**PLC setting** 83 83 84 84 (% class="wikigeneratedid" %) 85 85 ①[PLC]→[Change Communication Settings]→[Network Type] Ethernet→[setting…]→[Derive]→[IPaddress]set the IP address as PLC’s ,192.168.40.99→[Port Number]9600→[OK]→[OK] 86 86 Note:The IP address of the PLC is displayed on the LED when the PLC is powered up 87 87 87 +(% style="text-align:center" %) 88 +[[image:1.3.1.png]] 88 88 89 - **5)CableWiring**90 +②[PLC]→[Work Online]→USB connection between PC and PLC→The connection prompt appears→[Yes] 90 90 92 +(% style="text-align:center" %) 93 +[[image:1.3.2.png]] 94 + 95 +③PLC default parameters: [IO Table and Unit Settings] → [Built-in Port/Inner Board] [1500] CJ2M-EIP21→[TCP/IP] → [Transfer [Unit to PC]] → Transfer successfully, click [Close] 96 + 97 +[IP Address] Use the following address → [IP Address] 192.168.40.99, [Subnet Mask] 255.255.255.0. 98 +Note: Please configure the IP parameters of PLC according to the field needs 99 + 100 +(% style="text-align:center" %) 101 +[[image:1694161978199-503.4.png]] 102 + 103 +④Two rotary coding switches should be set depanding on the program paremeter: 104 +a) rotary coding switch for unit No. :For example, [Built-in Port/Inner Board] [1500] CJ2M-EIP21(Built In EtherNet/IP Port for CJ2M)(Unit: 0),the rotary coding switch should be dialed to 0 105 + 106 +(% style="text-align:center" %) 107 +[[image:WeCom Screenshot_20230828090604.png]] 108 + 109 +**b) rotary coding switch for node No. :The high byte 4 of the IP address should be the same as theone configured by the software. such as [IP address] 192.168.40.99. The IP address high byte 4 is 99,rotary coding switch is to use hexadecimal 63 corresponds to decimal 99, node number dialling code 161 corresponds to: 6, 160 corresponds to: 3.Address List** 110 + 111 +(% style="text-align:center" %) 112 +[[image:WeCom.png]] 113 + 114 +**Cable Wiring** 115 + 91 91 Pin Definition Diagram 92 92 118 +(% style="text-align:center" %) 119 +[[image:12.PLC Protocol_html_2297240b57346b2a.png]] 120 + 121 +== **CJ2M Serial** == 122 + 123 +**V-BOX setting** 124 + 125 +|**Items**|((( 126 +**Settings** 127 +))) 128 +|Protocol|OMRON CV/CJ1M/CS1H 129 +|Connection|RS232/RS485 130 +|Baud rate|9600 131 +|Data bit|7 132 +|Parity|EVEN 133 +|2|2 134 +|PLC station No.|0 135 + 136 +**Device Address:** 137 + 138 +|=**type**|=**Device type**|=**Format**|=**Range**|=**Note** 139 +|=(% colspan="1" rowspan="23" %)((( 140 +B 141 +)))|CIO|DDDDDdd|0 ~~65535.15|I/O and Internal Relay 142 +|W|DDDDDdd|0 ~~65535.15|Hold Relay 143 +|D|DDDDDdd|0 ~~65535.15|Link Relay 144 +|H|DDDDDdd|0 ~~65535.15| 145 +|A|DDDDDdd|0 ~~65535.15| 146 +|TF|DDDDD|0 ~~ 99999| 147 +|CF|DDDDD|0 ~~ 99999|Auxiliary Relay 148 +|T|DDDDDdd|0 ~~65535.15| 149 +|C|DDDDDdd|0 ~~65535.15| 150 +|EM0|DDDDDdd|0 ~~ 99999.15| 151 +|EM1|DDDDDdd|0 ~~ 99999.15| 152 +|EM2|DDDDDdd|0 ~~ 99999.15| 153 +|EM3|DDDDDdd|0 ~~ 99999.15| 154 +|EM4|DDDDDdd|0 ~~ 99999.15| 155 +|EM5|DDDDDdd|0 ~~ 99999.15| 156 +|EM6|DDDDDdd|0 ~~ 99999.15| 157 +|EM7|DDDDDdd|0 ~~ 99999.15| 158 +|EM8|DDDDDdd|0 ~~ 99999.15| 159 +|EM9|DDDDDdd|0 ~~ 99999.15| 160 +|EMA|DDDDDdd|0 ~~ 99999.15| 161 +|EMB|DDDDDdd|0 ~~ 99999.15| 162 +|EMC|DDDDDdd|0 ~~ 99999.15| 163 +|Lamp|D|0~~0| 164 +|(% colspan="1" rowspan="22" %)Word|W|DDDDD|0 ~~ 99999| 165 +|D|DDDDD|0 ~~ 99999| 166 +|H|DDDDD|0 ~~ 99999| 167 +|A|DDDDD|0 ~~ 99999| 168 +|T|DDDDD|0 ~~ 99999| 169 +|C|DDDDD|0 ~~ 99999| 170 +|CIO|DDDDD|0 ~~ 99999| 171 +|EM0|DDDDD|0 ~~ 99999| 172 +|EM1|DDDDD|0 ~~ 99999| 173 +|EM2|DDDDD|0 ~~ 99999| 174 +|EM3|DDDDD|0 ~~ 99999| 175 +|EM4|DDDDD|0 ~~ 99999| 176 +|EM5|DDDDD|0 ~~ 99999| 177 +|EM6|DDDDD|0 ~~ 99999| 178 +|EM7|DDDDD|0 ~~ 99999| 179 +|EM8|DDDDD|0 ~~ 99999| 180 +|EM9|DDDDD|0 ~~ 99999| 181 +|EMA|DDDDD|0 ~~ 99999| 182 +|EMB|DDDDD|0 ~~ 99999| 183 +|EMC|DDDDD|0 ~~ 99999| 184 +|IR|DDDDD|0 ~~ 99999| 185 +|DR|DDDDD|0 ~~ 99999| 186 + 187 +(% style="text-align:center" %) 188 +[[image:CJ2M串口协议配置.png]] 189 + 190 +**PLC Setting:** 191 + 192 +Open cx-programmer, create a new PLC project or open the project that has been created. 193 +Create new project: [File]→[New]→[Device Type]CJ2M→[settings]→[General]→[CPU Type]CPU31→[OK]→[OK]. 194 + 195 +(% style="text-align:center" %) 196 +[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_1edc9bf9e8c98170.png]] 197 + 198 +PLC Default Parameters:[Settings]→[Serial Port]→[Communication Settings]→[Standard]9600,1,7,2,E means:[Baud rate] 9600, [Data bits]7, [Stop bits] 2,[Parity] EVEN→[Unit Number]0 →[Mode]Host Link. 199 + 200 +{{info}} 201 +✎Note:The serial port parameters should be set depending on field requirements 202 +{{/info}} 203 + 204 +(% style="text-align:center" %) 205 +[[image:xwiki_PIStudio_12.PLC2.png]] 206 + 207 + 208 + 93 93 == **EC55 Series ** == 94 94 95 95 Supported device: EC55 temperature instrument
- 1.3.1.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.AiXia - Size
-
... ... @@ -1,0 +1,1 @@ 1 +74.9 KB - Content
- 1.3.2.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.AiXia - Size
-
... ... @@ -1,0 +1,1 @@ 1 +67.7 KB - Content
- 12.PLC Protocol_html_2297240b57346b2a.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.AiXia - Size
-
... ... @@ -1,0 +1,1 @@ 1 +107.1 KB - Content
- 1694161978199-503.4.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.AiXia - Size
-
... ... @@ -1,0 +1,1 @@ 1 +94.6 KB - Content
- CJ2M串口协议配置.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.AiXia - Size
-
... ... @@ -1,0 +1,1 @@ 1 +64.7 KB - Content
- WeCom Screenshot_20230828090604.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.AiXia - Size
-
... ... @@ -1,0 +1,1 @@ 1 +40.2 KB - Content
- WeCom.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.AiXia - Size
-
... ... @@ -1,0 +1,1 @@ 1 +40.2 KB - Content
- xwiki_PIStudio_12.PLC+protocols_WebHome_1edc9bf9e8c98170.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.AiXia - Size
-
... ... @@ -1,0 +1,1 @@ 1 +54.3 KB - Content
- xwiki_PIStudio_12.PLC2.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.AiXia - Size
-
... ... @@ -1,0 +1,1 @@ 1 +70.2 KB - Content