... ... @@ -24,9 +24,8 @@
24 24  (% style="text-align:center" %)
25 25  [[image:欧姆龙创建.png]]
26 26  
27 -**2)Address List **
27 +**Address List **
28 28  
29 -
30 30  |=**Type**|=**Device registers**|=**HMI registers**|=**Format**|=**Range**|=**Note**
31 31  |(% colspan="1" rowspan="23" %)Bit
32 32   |CIO|CIO|CIO d|0~~99999|
... ... @@ -79,17 +79,46 @@
79 79  |DR|DR|DR d|0~~99999|
80 80  
81 81  (% class="wikigeneratedid" %)
82 -**3)PLC software**
81 +**PLC setting**
83 83  
84 84  (% class="wikigeneratedid" %)
85 85  ①[PLC]→[Change Communication Settings]→[Network Type] Ethernet→[setting…]→[Derive]→[IPaddress]set the IP address as PLC’s ,192.168.40.99→[Port Number]9600→[OK]→[OK]
86 86  Note:The IP address of the PLC is displayed on the LED when the PLC is powered up
87 87  
87 +(% style="text-align:center" %)
88 +[[image:1.3.1.png]]
88 88  
89 -**5)Cable Wiring**
90 +②[PLC]→[Work Online]→USB connection between PC and PLC→The connection prompt appears→[Yes]
90 90  
92 +(% style="text-align:center" %)
93 +[[image:1.3.2.png]]
94 +
95 +③PLC default parameters: [IO Table and Unit Settings] → [Built-in Port/Inner Board] [1500] CJ2M-EIP21→[TCP/IP] → [Transfer [Unit to PC]] → Transfer successfully, click [Close]
96 +
97 +[IP Address] Use the following address → [IP Address] 192.168.40.99, [Subnet Mask] 255.255.255.0.
98 +Note: Please configure the IP parameters of PLC according to the field needs
99 +
100 +(% style="text-align:center" %)
101 +[[image:1694161978199-503.4.png]]
102 +
103 +④Two rotary coding switches should be set depanding on the program paremeter:
104 +a) rotary coding switch for unit No. :For example, [Built-in Port/Inner Board] [1500] CJ2M-EIP21(Built In EtherNet/IP Port for CJ2M)(Unit: 0),the rotary coding switch should be dialed to 0
105 +
106 +(% style="text-align:center" %)
107 +[[image:WeCom Screenshot_20230828090604.png]]
108 +
109 +**b) rotary coding switch for node No. :The high byte 4 of the IP address should be the same as theone configured by the software. such as [IP address] 192.168.40.99. The IP address high byte 4 is 99,rotary coding switch is to use hexadecimal 63 corresponds to decimal 99, node number dialling code 161 corresponds to: 6, 160 corresponds to: 3.Address List**
110 +
111 +(% style="text-align:center" %)
112 +[[image:WeCom.png]]
113 +
114 +**Cable Wiring**
115 +
91 91  Pin Definition Diagram
92 92  
118 +(% style="text-align:center" %)
119 +[[image:12.PLC Protocol_html_2297240b57346b2a.png]]
120 +
93 93  == **EC55 Series ** ==
94 94  
95 95  Supported device: EC55 temperature instrument
1.3.1.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.AiXia
Size
... ... @@ -1,0 +1,1 @@
1 +74.9 KB
Content
1.3.2.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.AiXia
Size
... ... @@ -1,0 +1,1 @@
1 +67.7 KB
Content
12.PLC Protocol_html_2297240b57346b2a.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.AiXia
Size
... ... @@ -1,0 +1,1 @@
1 +107.1 KB
Content
1694161978199-503.4.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.AiXia
Size
... ... @@ -1,0 +1,1 @@
1 +94.6 KB
Content
WeCom Screenshot_20230828090604.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.AiXia
Size
... ... @@ -1,0 +1,1 @@
1 +40.2 KB
Content
WeCom.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.AiXia
Size
... ... @@ -1,0 +1,1 @@
1 +40.2 KB
Content