Changes for page Omron
Last modified by Theodore Xu on 2023/09/16 10:47
From version 8.1
edited by Theodore Xu
on 2023/09/08 16:35
on 2023/09/08 16:35
Change comment:
There is no comment for this version
To version 12.1
edited by Theodore Xu
on 2023/09/12 11:41
on 2023/09/12 11:41
Change comment:
There is no comment for this version
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 3 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -8,7 +8,7 @@ 8 8 9 9 [[Download>>url:https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communication%20with%20ORMON%20CJ2M.zip]] 10 10 11 -== **CJ TCP FINSEthemet** ==11 +== **CJ2M Ethemet** == 12 12 13 13 Supported device:CJ series, CJ1W-EIP21,CJ2M-EIP21 14 14 ... ... @@ -24,7 +24,7 @@ 24 24 (% style="text-align:center" %) 25 25 [[image:欧姆龙创建.png]] 26 26 27 -** 2)Address List **27 +**Address List ** 28 28 29 29 |=**Type**|=**Device registers**|=**HMI registers**|=**Format**|=**Range**|=**Note** 30 30 |(% colspan="1" rowspan="23" %)Bit ... ... @@ -78,7 +78,7 @@ 78 78 |DR|DR|DR d|0~~99999| 79 79 80 80 (% class="wikigeneratedid" %) 81 -** 3)PLC software**81 +**PLC setting** 82 82 83 83 (% class="wikigeneratedid" %) 84 84 ①[PLC]→[Change Communication Settings]→[Network Type] Ethernet→[setting…]→[Derive]→[IPaddress]set the IP address as PLC’s ,192.168.40.99→[Port Number]9600→[OK]→[OK] ... ... @@ -111,7 +111,7 @@ 111 111 (% style="text-align:center" %) 112 112 [[image:WeCom.png]] 113 113 114 -** 4)Cable Wiring**114 +**Cable Wiring** 115 115 116 116 Pin Definition Diagram 117 117 ... ... @@ -118,6 +118,94 @@ 118 118 (% style="text-align:center" %) 119 119 [[image:12.PLC Protocol_html_2297240b57346b2a.png]] 120 120 121 +== **CJ2M Serial** == 122 + 123 +**V-BOX setting** 124 + 125 +|**Items**|((( 126 +**Settings** 127 +))) 128 +|Protocol|OMRON CV/CJ1M/CS1H 129 +|Connection|RS232/RS485 130 +|Baud rate|9600 131 +|Data bit|7 132 +|Parity|EVEN 133 +|2|2 134 +|PLC station No.|0 135 + 136 +**Device Address:** 137 + 138 +|=**type**|=**Device type**|=**Format**|=**Range**|=**Note** 139 +|=(% colspan="1" rowspan="23" %)((( 140 +B 141 +)))|CIO|DDDDDdd|0 ~~65535.15|I/O and Internal Relay 142 +|W|DDDDDdd|0 ~~65535.15|Hold Relay 143 +|D|DDDDDdd|0 ~~65535.15|Link Relay 144 +|H|DDDDDdd|0 ~~65535.15| 145 +|A|DDDDDdd|0 ~~65535.15| 146 +|TF|DDDDD|0 ~~ 99999| 147 +|CF|DDDDD|0 ~~ 99999|Auxiliary Relay 148 +|T|DDDDDdd|0 ~~65535.15| 149 +|C|DDDDDdd|0 ~~65535.15| 150 +|EM0|DDDDDdd|0 ~~ 99999.15| 151 +|EM1|DDDDDdd|0 ~~ 99999.15| 152 +|EM2|DDDDDdd|0 ~~ 99999.15| 153 +|EM3|DDDDDdd|0 ~~ 99999.15| 154 +|EM4|DDDDDdd|0 ~~ 99999.15| 155 +|EM5|DDDDDdd|0 ~~ 99999.15| 156 +|EM6|DDDDDdd|0 ~~ 99999.15| 157 +|EM7|DDDDDdd|0 ~~ 99999.15| 158 +|EM8|DDDDDdd|0 ~~ 99999.15| 159 +|EM9|DDDDDdd|0 ~~ 99999.15| 160 +|EMA|DDDDDdd|0 ~~ 99999.15| 161 +|EMB|DDDDDdd|0 ~~ 99999.15| 162 +|EMC|DDDDDdd|0 ~~ 99999.15| 163 +|Lamp|D|0~~0| 164 +|(% colspan="1" rowspan="22" %)Word|W|DDDDD|0 ~~ 99999| 165 +|D|DDDDD|0 ~~ 99999| 166 +|H|DDDDD|0 ~~ 99999| 167 +|A|DDDDD|0 ~~ 99999| 168 +|T|DDDDD|0 ~~ 99999| 169 +|C|DDDDD|0 ~~ 99999| 170 +|CIO|DDDDD|0 ~~ 99999| 171 +|EM0|DDDDD|0 ~~ 99999| 172 +|EM1|DDDDD|0 ~~ 99999| 173 +|EM2|DDDDD|0 ~~ 99999| 174 +|EM3|DDDDD|0 ~~ 99999| 175 +|EM4|DDDDD|0 ~~ 99999| 176 +|EM5|DDDDD|0 ~~ 99999| 177 +|EM6|DDDDD|0 ~~ 99999| 178 +|EM7|DDDDD|0 ~~ 99999| 179 +|EM8|DDDDD|0 ~~ 99999| 180 +|EM9|DDDDD|0 ~~ 99999| 181 +|EMA|DDDDD|0 ~~ 99999| 182 +|EMB|DDDDD|0 ~~ 99999| 183 +|EMC|DDDDD|0 ~~ 99999| 184 +|IR|DDDDD|0 ~~ 99999| 185 +|DR|DDDDD|0 ~~ 99999| 186 + 187 +(% style="text-align:center" %) 188 +[[image:CJ2M串口协议配置.png]] 189 + 190 +**PLC Setting:** 191 + 192 +Open cx-programmer, create a new PLC project or open the project that has been created. 193 +Create new project: [File]→[New]→[Device Type]CJ2M→[settings]→[General]→[CPU Type]CPU31→[OK]→[OK]. 194 + 195 +(% style="text-align:center" %) 196 +[[image:xwiki_PIStudio_12.PLC+protocols_WebHome_1edc9bf9e8c98170.png]] 197 + 198 +PLC Default Parameters:[Settings]→[Serial Port]→[Communication Settings]→[Standard]9600,1,7,2,E means:[Baud rate] 9600, [Data bits]7, [Stop bits] 2,[Parity] EVEN→[Unit Number]0 →[Mode]Host Link. 199 + 200 +{{info}} 201 +✎Note:The serial port parameters should be set depending on field requirements 202 +{{/info}} 203 + 204 +(% style="text-align:center" %) 205 +[[image:xwiki_PIStudio_12.PLC2.png]] 206 + 207 + 208 + 121 121 == **EC55 Series ** == 122 122 123 123 Supported device: EC55 temperature instrument
- CJ2M串口协议配置.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.AiXia - Size
-
... ... @@ -1,0 +1,1 @@ 1 +64.7 KB - Content
- xwiki_PIStudio_12.PLC+protocols_WebHome_1edc9bf9e8c98170.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.AiXia - Size
-
... ... @@ -1,0 +1,1 @@ 1 +54.3 KB - Content
- xwiki_PIStudio_12.PLC2.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.AiXia - Size
-
... ... @@ -1,0 +1,1 @@ 1 +70.2 KB - Content