Changes for page Omron
Last modified by Theodore Xu on 2023/09/16 10:47
From version 8.1
edited by Theodore Xu
on 2023/09/08 16:35
on 2023/09/08 16:35
Change comment:
There is no comment for this version
To version 5.1
edited by Theodore Xu
on 2023/09/07 19:18
on 2023/09/07 19:18
Change comment:
There is no comment for this version
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 0 added, 7 removed)
Details
- Page properties
-
- Content
-
... ... @@ -26,98 +26,61 @@ 26 26 27 27 **2)Address List ** 28 28 29 -|=**Type**|=**Device registers**|=**HMI registers**|=**Format**|=**Range**|=**Note** 30 -|(% colspan="1" rowspan="23" %)Bit 31 - |CIO|CIO|CIO d|0~~99999| 32 -|W|W|W d|0~~99999| 33 -|D|D|D d|0~~99999| 34 -|H|H|H d|0~~99999| 35 -|A|A|A d|0~~99999| 36 -|T|T|T h|0~~99999| 37 -|CF|CF|CF d|0~~99999| 38 -|FF|FF|FF d|0~~99999| 39 -|C|C|C d|0~~99999| 40 -|EM0|EM0|EM0 d|0~~99999| 41 -|EM1|EM1|EM1 d|0~~99999| 42 -|EM2|EM2|EM2 d|0~~99999| 43 -|EM3|EM3|EM3 d|0~~99999| 44 -|EM4|EM4|EM4 d|0~~99999| 45 -|EM5|EM5|EM5 h|0~~99999| 46 -|EM6|EM6|EM6 d|0~~99999| 47 -|EM7|EM7|EM7 d|0~~99999| 48 -|EM8|EM8|EM8 d|0~~99999| 49 -|EM9|EM9|EM9 d|0~~99999| 50 -|EMA|EMA|EMA d|0~~99999| 51 -|EMB|EMB|EMB d|0~~99999| 52 -|EMC|EMC|EMC d|0~~99999| 53 -|Lamp|Lamp|Lamp d|0~~0| 54 -|(% colspan="1" rowspan="24" %)Word 55 - |CIO|CIO|CIO d|0~~99999| 56 -|W|W|W d|0~~99999| 57 -|D|D|D d|0~~99999| 58 -|H|H|H d|0~~99999| 59 -|A|A|A d|0~~99999| 60 -|T|T|T h|0~~99999| 61 -|CF|CF|CF d|0~~99999| 62 -|FF|FF|FF d|0~~99999| 63 -|C|C|C d|0~~99999| 64 -|EM0|EM0|EM0 d|0~~99999| 65 -|EM1|EM1|EM1 d|0~~99999| 66 -|EM2|EM2|EM2 d|0~~99999| 67 -|EM3|EM3|EM3 d|0~~99999| 68 -|EM4|EM4|EM4 d|0~~99999| 69 -|EM5|EM5|EM5 h|0~~99999| 70 -|EM6|EM6|EM6 d|0~~99999| 71 -|EM7|EM7|EM7 d|0~~99999| 72 -|EM8|EM8|EM8 d|0~~99999| 73 -|EM9|EM9|EM9 d|0~~99999| 74 -|EMA|EMA|EMA d|0~~99999| 75 -|EMB|EMB|EMB d|0~~99999| 76 -|EMC|EMC|EMC d|0~~99999| 77 -|IR|IR|IR d|0~~99999| 78 -|DR|DR|DR d|0~~99999| 79 79 80 -(% class="wikigeneratedid" %) 81 -**3)PLC software** 30 +|**Type**|**Device register**|**HMI register**|**Format**|**Range**|**Note** 31 +|(% rowspan="9" %)Bit|I|I|I ddddd.o|0.0~~99999.7| 32 +|Q|Q|Q ddddd.o|0.0~~99999.7| 33 +|V|VWbit|VWbit ddddd.o|0.0~~99999.7| 34 +|V|V|V ddddd.o|0.0~~99999.7| 35 +|M|M|M ddddd.o|0.0~~99999.7| 36 +|SM|SM|ddddd.o|0.0~~99999.7| 37 +|S|S|ddddd.o|0.0~~99999.7|Read only 38 +|T|T|ddddd|0~~99999|Timer state, read only 39 +|C|C|ddddd|0~~99999|Counter state, read only 40 +|(% rowspan="12" %)Word|I|IW|IW ddddd|0~~99999| 41 +|Q|QW|QW ddddd|0~~99999| 42 +|AI|AIW|AIW ddddd|0~~99999| 43 +|AQ|VB|VB ddddd|0~~99999| 44 +|V|VW|VW ddddd|0~~99998|((( 45 +VW0=VB (0~~1) 82 82 83 -(% class="wikigeneratedid" %) 84 -①[PLC]→[Change Communication Settings]→[Network Type] Ethernet→[setting…]→[Derive]→[IPaddress]set the IP address as PLC’s ,192.168.40.99→[Port Number]9600→[OK]→[OK] 85 -Note:The IP address of the PLC is displayed on the LED when the PLC is powered up 47 +VW2=VB (2~~3) 86 86 87 -(% style="text-align:center" %) 88 -[[image:1.3.1.png]] 49 +Address value is a multiple of 2 50 +))) 51 +|V|VD|VD ddddd|0~~99998|((( 52 +VD0=VB (0~~3) 89 89 90 - ②[PLC]→[Work Online]→USBconnection between PC and PLC→The connection prompt appears→[Yes]54 +VD2=VB (4~~7) 91 91 92 -(% style="text-align:center" %) 93 -[[image:1.3.2.png]] 56 +Address value is a multiple of 4 57 +))) 58 +|M|MB|MB ddddd|0~~99999| 59 +|M|MW|MW ddddd|0~~99999|((( 60 +MW0=MB(0~~1) 94 94 95 - ③PLC default parameters: [IO Table and Unit Settings] → [Built-in Port/Inner Board] [1500] CJ2M-EIP21→[TCP/IP] → [Transfer [Unit to PC]] → Transfer successfully, click [Close]62 +MW2=MB(2~~3) 96 96 97 -[IP Address] Use the following address → [IP Address] 192.168.40.99, [Subnet Mask] 255.255.255.0. 98 -Note: Please configure the IP parameters of PLC according to the field needs 64 +Address value is a multiple of 2 65 +))) 66 +|M|MD|MD ddddd|0~~99999|((( 67 +MD0=MB(0~~3) 99 99 100 -(% style="text-align:center" %) 101 -[[image:1694161978199-503.4.png]] 69 +MD4=MB(4~~7) 102 102 103 -④Two rotary coding switches should be set depanding on the program paremeter: 104 -a) rotary coding switch for unit No. :For example, [Built-in Port/Inner Board] [1500] CJ2M-EIP21(Built In EtherNet/IP Port for CJ2M)(Unit: 0),the rotary coding switch should be dialed to 0 71 +Address value is a multiple of 4 72 +))) 73 +|T|TW|TW ddddd|0~~99999|Value of timer 74 +|C|CW|CW ddddd|0~~99999|Value of counter 75 +|W|SW|SW ddddd|0~~99999| 105 105 106 -(% style="text-align:center" %)107 - [[image:WeComScreenshot_20230828090604.png]]77 +(% class="wikigeneratedid" %) 78 +**3)PLC software** 108 108 109 -**b) rotary coding switch for node No. :The high byte 4 of the IP address should be the same as theone configured by the software. such as [IP address] 192.168.40.99. The IP address high byte 4 is 99,rotary coding switch is to use hexadecimal 63 corresponds to decimal 99, node number dialling code 161 corresponds to: 6, 160 corresponds to: 3.Address List** 80 +(% class="wikigeneratedid" %) 81 +①[PLC]→[Change Communication Settings]→[Network Type] Ethernet→[setting…]→[Derive]→[IPaddress]set the IP address as PLC’s ,192.168.40.99→[Port Number]9600→[OK]→[OK] 82 +Note:The IP address of the PLC is displayed on the LED when the PLC is powered up 110 110 111 -(% style="text-align:center" %) 112 -[[image:WeCom.png]] 113 - 114 -**4)Cable Wiring** 115 - 116 -Pin Definition Diagram 117 - 118 -(% style="text-align:center" %) 119 -[[image:12.PLC Protocol_html_2297240b57346b2a.png]] 120 - 121 121 == **EC55 Series ** == 122 122 123 123 Supported device: EC55 temperature instrument
- 1.3.1.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.AiXia - Size
-
... ... @@ -1,1 +1,0 @@ 1 -74.9 KB - Content
- 1.3.2.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.AiXia - Size
-
... ... @@ -1,1 +1,0 @@ 1 -67.7 KB - Content
- 12.PLC Protocol_html_2297240b57346b2a.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.AiXia - Size
-
... ... @@ -1,1 +1,0 @@ 1 -107.1 KB - Content
- 1694161978199-503.4.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.AiXia - Size
-
... ... @@ -1,1 +1,0 @@ 1 -94.6 KB - Content
- WeCom Screenshot_20230828090604.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.AiXia - Size
-
... ... @@ -1,1 +1,0 @@ 1 -40.2 KB - Content
- WeCom.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.AiXia - Size
-
... ... @@ -1,1 +1,0 @@ 1 -40.2 KB - Content
- 欧姆龙创建.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.AiXia - Size
-
... ... @@ -1,1 +1,0 @@ 1 -65.8 KB - Content