Changes for page Omron

Last modified by Theodore Xu on 2023/09/16 10:47

From version 8.1
edited by Theodore Xu
on 2023/09/08 16:35
Change comment: There is no comment for this version
To version 5.1
edited by Theodore Xu
on 2023/09/07 19:18
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -26,98 +26,61 @@
26 26  
27 27  **2)Address List **
28 28  
29 -|=**Type**|=**Device registers**|=**HMI registers**|=**Format**|=**Range**|=**Note**
30 -|(% colspan="1" rowspan="23" %)Bit
31 - |CIO|CIO|CIO d|0~~99999|
32 -|W|W|W d|0~~99999|
33 -|D|D|D d|0~~99999|
34 -|H|H|H d|0~~99999|
35 -|A|A|A d|0~~99999|
36 -|T|T|T h|0~~99999|
37 -|CF|CF|CF d|0~~99999|
38 -|FF|FF|FF d|0~~99999|
39 -|C|C|C d|0~~99999|
40 -|EM0|EM0|EM0 d|0~~99999|
41 -|EM1|EM1|EM1 d|0~~99999|
42 -|EM2|EM2|EM2 d|0~~99999|
43 -|EM3|EM3|EM3 d|0~~99999|
44 -|EM4|EM4|EM4 d|0~~99999|
45 -|EM5|EM5|EM5 h|0~~99999|
46 -|EM6|EM6|EM6 d|0~~99999|
47 -|EM7|EM7|EM7 d|0~~99999|
48 -|EM8|EM8|EM8 d|0~~99999|
49 -|EM9|EM9|EM9 d|0~~99999|
50 -|EMA|EMA|EMA d|0~~99999|
51 -|EMB|EMB|EMB d|0~~99999|
52 -|EMC|EMC|EMC d|0~~99999|
53 -|Lamp|Lamp|Lamp d|0~~0|
54 -|(% colspan="1" rowspan="24" %)Word
55 - |CIO|CIO|CIO d|0~~99999|
56 -|W|W|W d|0~~99999|
57 -|D|D|D d|0~~99999|
58 -|H|H|H d|0~~99999|
59 -|A|A|A d|0~~99999|
60 -|T|T|T h|0~~99999|
61 -|CF|CF|CF d|0~~99999|
62 -|FF|FF|FF d|0~~99999|
63 -|C|C|C d|0~~99999|
64 -|EM0|EM0|EM0 d|0~~99999|
65 -|EM1|EM1|EM1 d|0~~99999|
66 -|EM2|EM2|EM2 d|0~~99999|
67 -|EM3|EM3|EM3 d|0~~99999|
68 -|EM4|EM4|EM4 d|0~~99999|
69 -|EM5|EM5|EM5 h|0~~99999|
70 -|EM6|EM6|EM6 d|0~~99999|
71 -|EM7|EM7|EM7 d|0~~99999|
72 -|EM8|EM8|EM8 d|0~~99999|
73 -|EM9|EM9|EM9 d|0~~99999|
74 -|EMA|EMA|EMA d|0~~99999|
75 -|EMB|EMB|EMB d|0~~99999|
76 -|EMC|EMC|EMC d|0~~99999|
77 -|IR|IR|IR d|0~~99999|
78 -|DR|DR|DR d|0~~99999|
79 79  
80 -(% class="wikigeneratedid" %)
81 -**3)PLC software**
30 +|**Type**|**Device register**|**HMI register**|**Format**|**Range**|**Note**
31 +|(% rowspan="9" %)Bit|I|I|I ddddd.o|0.0~~99999.7|
32 +|Q|Q|Q ddddd.o|0.0~~99999.7|
33 +|V|VWbit|VWbit ddddd.o|0.0~~99999.7|
34 +|V|V|V ddddd.o|0.0~~99999.7|
35 +|M|M|M ddddd.o|0.0~~99999.7|
36 +|SM|SM|ddddd.o|0.0~~99999.7|
37 +|S|S|ddddd.o|0.0~~99999.7|Read only
38 +|T|T|ddddd|0~~99999|Timer state, read only
39 +|C|C|ddddd|0~~99999|Counter state, read only
40 +|(% rowspan="12" %)Word|I|IW|IW ddddd|0~~99999|
41 +|Q|QW|QW ddddd|0~~99999|
42 +|AI|AIW|AIW ddddd|0~~99999|
43 +|AQ|VB|VB ddddd|0~~99999|
44 +|V|VW|VW ddddd|0~~99998|(((
45 +VW0=VB (0~~1)
82 82  
83 -(% class="wikigeneratedid" %)
84 -①[PLC]→[Change Communication Settings]→[Network Type] Ethernet→[setting…]→[Derive]→[IPaddress]set the IP address as PLC’s ,192.168.40.99→[Port Number]9600→[OK]→[OK]
85 -Note:The IP address of the PLC is displayed on the LED when the PLC is powered up
47 +VW2=VB (2~~3)
86 86  
87 -(% style="text-align:center" %)
88 -[[image:1.3.1.png]]
49 +Address value is a multiple of 2
50 +)))
51 +|V|VD|VD ddddd|0~~99998|(((
52 +VD0=VB (0~~3)
89 89  
90 -②[PLC]→[Work Online]→USB connection between PC and PLC→The connection prompt appears→[Yes]
54 +VD2=VB (4~~7)
91 91  
92 -(% style="text-align:center" %)
93 -[[image:1.3.2.png]]
56 +Address value is a multiple of 4
57 +)))
58 +|M|MB|MB ddddd|0~~99999|
59 +|M|MW|MW ddddd|0~~99999|(((
60 +MW0=MB(0~~1)
94 94  
95 -③PLC default parameters: [IO Table and Unit Settings] → [Built-in Port/Inner Board] [1500] CJ2M-EIP21→[TCP/IP] → [Transfer [Unit to PC]] → Transfer successfully, click [Close]
62 +MW2=MB(2~~3)
96 96  
97 -[IP Address] Use the following address → [IP Address] 192.168.40.99, [Subnet Mask] 255.255.255.0.
98 -Note: Please configure the IP parameters of PLC according to the field needs
64 +Address value is a multiple of 2
65 +)))
66 +|M|MD|MD ddddd|0~~99999|(((
67 +MD0=MB(0~~3)
99 99  
100 -(% style="text-align:center" %)
101 -[[image:1694161978199-503.4.png]]
69 +MD4=MB(4~~7)
102 102  
103 -④Two rotary coding switches should be set depanding on the program paremeter:
104 -a) rotary coding switch for unit No. :For example, [Built-in Port/Inner Board] [1500] CJ2M-EIP21(Built In EtherNet/IP Port for CJ2M)(Unit: 0),the rotary coding switch should be dialed to 0
71 +Address value is a multiple of 4
72 +)))
73 +|T|TW|TW ddddd|0~~99999|Value of timer
74 +|C|CW|CW ddddd|0~~99999|Value of counter
75 +|W|SW|SW ddddd|0~~99999|
105 105  
106 -(% style="text-align:center" %)
107 -[[image:WeCom Screenshot_20230828090604.png]]
77 +(% class="wikigeneratedid" %)
78 +**3)PLC software**
108 108  
109 -**b) rotary coding switch for node No. :The high byte 4 of the IP address should be the same as theone configured by the software. such as [IP address] 192.168.40.99. The IP address high byte 4 is 99,rotary coding switch is to use hexadecimal 63 corresponds to decimal 99, node number dialling code 161 corresponds to: 6, 160 corresponds to: 3.Address List**
80 +(% class="wikigeneratedid" %)
81 +①[PLC]→[Change Communication Settings]→[Network Type] Ethernet→[setting…]→[Derive]→[IPaddress]set the IP address as PLC’s ,192.168.40.99→[Port Number]9600→[OK]→[OK]
82 +Note:The IP address of the PLC is displayed on the LED when the PLC is powered up
110 110  
111 -(% style="text-align:center" %)
112 -[[image:WeCom.png]]
113 -
114 -**4)Cable Wiring**
115 -
116 -Pin Definition Diagram
117 -
118 -(% style="text-align:center" %)
119 -[[image:12.PLC Protocol_html_2297240b57346b2a.png]]
120 -
121 121  == **EC55 Series ** ==
122 122  
123 123  Supported device: EC55 temperature instrument
1.3.1.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.AiXia
Size
... ... @@ -1,1 +1,0 @@
1 -74.9 KB
Content
1.3.2.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.AiXia
Size
... ... @@ -1,1 +1,0 @@
1 -67.7 KB
Content
12.PLC Protocol_html_2297240b57346b2a.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.AiXia
Size
... ... @@ -1,1 +1,0 @@
1 -107.1 KB
Content
1694161978199-503.4.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.AiXia
Size
... ... @@ -1,1 +1,0 @@
1 -94.6 KB
Content
WeCom Screenshot_20230828090604.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.AiXia
Size
... ... @@ -1,1 +1,0 @@
1 -40.2 KB
Content
WeCom.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.AiXia
Size
... ... @@ -1,1 +1,0 @@
1 -40.2 KB
Content
欧姆龙创建.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.AiXia
Size
... ... @@ -1,1 +1,0 @@
1 -65.8 KB
Content