Changes for page Xinje
Last modified by Theodore Xu on 2023/11/06 10:28
From version 8.1
edited by Leo Wei
on 2023/08/24 14:11
on 2023/08/24 14:11
Change comment:
There is no comment for this version
To version 9.1
edited by Theodore Xu
on 2023/11/06 10:26
on 2023/11/06 10:26
Change comment:
There is no comment for this version
Summary
-
Page properties (2 modified, 0 added, 0 removed)
-
Attachments (0 modified, 14 added, 0 removed)
- XinjieXCDownloadPLC.png
- XinjieXCPCconn.png
- XinjieXCPLCModbusConfig.png
- XinjieXCPrg.png
- XinjieXCcreatenew.png
- XinjieXDLDprg.png
- XinjieXDPLCtestconn.png
- XinjieXDclickto.png
- XinjieXDcomplete.png
- XinjieXDcreatenew.png
- XinjieXDdownload.png
- XinjieXDdownloadopt.png
- XinjieXDopenSWcom (1).png
- XinjieXDsuccessprompt.png
Details
- Page properties
-
- Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki. admin1 +XWiki.AiXia - Content
-
... ... @@ -1,8 +1,8 @@ 1 -= {{idname="HXinje"/}}Xinje=1 += **XC serial** = 2 2 3 - =={{idname="HXCserial"/}}**XCserial** ==3 +Support Series: Xinjie XC Series 4 4 5 -** 1)V-BOXSettings**5 +**V-Box Settings** 6 6 7 7 |**Item**|**Settings**|**Note** 8 8 |Protocol|XINJE XC MODBUS| ... ... @@ -13,8 +13,10 @@ 13 13 |Stop bit|1| 14 14 |PLC station No.|1| 15 15 16 - **2)AddressList**16 +[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_848ef1522d877523.png||alt="image-20220831163041-1.png" height="705" width="1676"]] 17 17 18 +**Address List** 19 + 18 18 |**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note** 19 19 |Bit|M|M|M d|0~~8511| 20 20 |Bit|X|X|X o|0~~1747| ... ... @@ -27,23 +27,46 @@ 27 27 |Word|CD|CD|CD d|0~~634| 28 28 |Word|FD|FD|FD d|0~~8511| 29 29 30 -** 3)Configurethecommunicationprotocol**32 +**PLC Settings** 31 31 32 - {{id name="Iimage-20220831163041-1.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_848ef1522d877523.png||alt="image-20220831163041-1.png"height="705"width="1676"]]34 +Create the new project, and select the specific model according to the actual PLC 33 33 34 -**4)Cable Wiring** 36 +(% style="text-align:center" %) 37 +[[image:XinjieXCcreatenew.png]] 35 35 39 +Program the PLC 40 + 41 +(% style="text-align:center" %) 42 +[[image:XinjieXCPrg.png]] 43 + 44 +Connect PLC with PC through RS232-USB converter cable. Click [Option]-[Software Serial Port Config] to open the software connection setup window, and select the serial port, if the red text prompt "Connect To PLC Succeeded", which means the connection is setup successfully, then click OK to save the settings. 45 + 46 +(% style="text-align:center" %) 47 +[[image:XinjieXCPCconn.png]] 48 + 49 +Change the PLC communication setup if required. Double click the tree node [PLC Serial Port] from Project tree. And change Modbus parameters, then click [Write to PLC] and OK to finish. 50 + 51 +(% style="text-align:center" %) 52 +[[image:XinjieXCPLCModbusConfig.png]] 53 + 54 +Click [Online]-[Download Program] to download program into PLC. And the download pop up window would pop up, then click OK. 55 + 56 +(% style="text-align:center" %) 57 +[[image:XinjieXCDownloadPLC.png]] 58 + 59 +**Cable Wiring** 60 + 36 36 Figure 37 37 38 - {{id name="Iimage-20220831163406-2.png"/}}{{id name="Iimage-20220831163422-3.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_a14861f1794a6a42.png||alt="image-20220831163406-2.png" height="266" width="101"]] [[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_3e55283fe70031d.png||alt="image-20220831163422-3.png" height="232" width="533"]]63 +[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_a14861f1794a6a42.png||alt="image-20220831163406-2.png" height="266" width="101"]] [[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_3e55283fe70031d.png||alt="image-20220831163422-3.png" height="232" width="533"]] 39 39 40 40 Pin Definition Diagram 41 41 42 - {{id name="Iimage-20220831163441-4.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_4e0c72812b72a12a.png||alt="image-20220831163441-4.png" height="167" width="336"]]67 +[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_4e0c72812b72a12a.png||alt="image-20220831163441-4.png" height="167" width="336"]] 43 43 44 -== {{id name="HXDserial"/}}**XD serial** ==69 +== **XD serial** == 45 45 46 -** 1)V-BOXSettings**71 +**V-Box Settings** 47 47 48 48 Supported Series: Xinjie XD/XE Series PLC 49 49 ... ... @@ -56,8 +56,10 @@ 56 56 |Stop bit|1| 57 57 |PLC station No.|1| 58 58 59 - **2)AddressList**84 +[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_2094eb9a27becb2c.png||alt="image-20220831163923-7.png" height="709" width="1677"]] 60 60 86 +**Address List** 87 + 61 61 |**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note** 62 62 |Bit|M|M|M d|0~~74999| 63 63 |Bit|X1xx|X1xx|X1xx o|0~~1177| ... ... @@ -97,16 +97,59 @@ 97 97 |Word|SFD|SFD|SFD d|0~~5999| 98 98 |Word|FS|FS|FS d|0~~47| 99 99 100 -** 3)Configurethecommunicationprotocol**127 +**PLC Settings** 101 101 102 - {{id name="Iimage-20220831163923-7.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_2094eb9a27becb2c.png||alt="image-20220831163923-7.png"height="709"width="1677"]]129 +Create the new project, and select the specific model according to the actual PLC 103 103 104 -**4)Cable Wiring** 131 +(% style="text-align:center" %) 132 +[[image:XinjieXDcreatenew.png]] 105 105 134 +Program the PLC 135 + 136 +(% style="text-align:center" %) 137 +[[image:XinjieXDLDprg.png]] 138 + 139 +Connect PLC with PC through RS232-USB converter cable. Click [Option]-[Software Serial Port Config]-[Communication configuration] to open the PC connection configuration. 140 + 141 +(% style="text-align:center" %) 142 +[[image:XinjieXDopenSWcom (1).png]] 143 + 144 +New a Modbus configuration, and Click [Comm-Test] to test connection, if shows "Connect To PLC Succeeded", which means PLC connection set up successfully. And click OK to save the settings. 145 + 146 +(% style="text-align:center" %) 147 +[[image:XinjieXDPLCtestconn.png]] 148 + 149 +Remember to click the Status cell of new created Modbus configuration for change the status into "in use", then click OK to exit. 150 + 151 +(% style="text-align:center" %) 152 +[[image:XinjieXDclickto.png]] 153 + 154 +After done the previous steps, it would prompt like the below. 155 + 156 +(% style="text-align:center" %) 157 +[[image:XinjieXDsuccessprompt.png]] 158 + 159 +Click [Online]-[Download Program & Data], and wait for a while, the pop up window would ask for whether to stop PLC, and click [Stop PLC, contitue download] 160 + 161 +(% style="text-align:center" %) 162 +[[image:XinjieXDdownload.png]] 163 + 164 +And then the XDPro ask for which options want to rewrite, and click OK to finish. 165 + 166 +(% style="text-align:center" %) 167 +[[image:XinjieXDdownloadopt.png]] 168 + 169 +If download successfully, it would prompt like the below. 170 + 171 +(% style="text-align:center" %) 172 +[[image:XinjieXDcomplete.png]] 173 + 174 +**Cable Wiring** 175 + 106 106 Figure 107 107 108 - {{id name="Iimage-20220831163406-2.png-1"/}}{{id name="Iimage-20220831163553-6.png"/}}[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_a14861f1794a6a42.png||alt="image-20220831163406-2.png" height="266" width="101"]] [[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_a8ea42846b443604.png||alt="image-20220831163553-6.png" height="206" width="465"]]178 +[[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_a14861f1794a6a42.png||alt="image-20220831163406-2.png" height="266" width="101"]] [[image:xwiki_V-BOX_V-Net_Training_1+Communication_WebHome_a8ea42846b443604.png||alt="image-20220831163553-6.png" height="206" width="465"]] 109 109 110 110 Pin Definition Diagram 111 111 112 - {{id name="Ihttps:2F2Fdocs.we-con.com.cn2Fbin2Fdownload2FPIStudio2F12.PLC2520protocols2FWebHome2Fimage-20220830160232-3.png3Frev3D1.1"/}}[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/image-20220830160232-3.png?rev=1.1||alt="image-20220830160232-3.png" height="38" width="76"]]182 +[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/image-20220830160232-3.png?rev=1.1||alt="image-20220830160232-3.png" height="218" width="709"]]
- XinjieXCDownloadPLC.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.AiXia - Size
-
... ... @@ -1,0 +1,1 @@ 1 +85.3 KB - Content
- XinjieXCPCconn.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.AiXia - Size
-
... ... @@ -1,0 +1,1 @@ 1 +65.7 KB - Content
- XinjieXCPLCModbusConfig.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.AiXia - Size
-
... ... @@ -1,0 +1,1 @@ 1 +47.1 KB - Content
- XinjieXCPrg.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.AiXia - Size
-
... ... @@ -1,0 +1,1 @@ 1 +6.4 KB - Content
- XinjieXCcreatenew.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.AiXia - Size
-
... ... @@ -1,0 +1,1 @@ 1 +36.7 KB - Content
- XinjieXDLDprg.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.AiXia - Size
-
... ... @@ -1,0 +1,1 @@ 1 +6.6 KB - Content
- XinjieXDPLCtestconn.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.AiXia - Size
-
... ... @@ -1,0 +1,1 @@ 1 +28.4 KB - Content
- XinjieXDclickto.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.AiXia - Size
-
... ... @@ -1,0 +1,1 @@ 1 +9.1 KB - Content
- XinjieXDcomplete.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.AiXia - Size
-
... ... @@ -1,0 +1,1 @@ 1 +3.9 KB - Content
- XinjieXDcreatenew.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.AiXia - Size
-
... ... @@ -1,0 +1,1 @@ 1 +48.3 KB - Content
- XinjieXDdownload.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.AiXia - Size
-
... ... @@ -1,0 +1,1 @@ 1 +86.4 KB - Content
- XinjieXDdownloadopt.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.AiXia - Size
-
... ... @@ -1,0 +1,1 @@ 1 +9.5 KB - Content
- XinjieXDopenSWcom (1).png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.AiXia - Size
-
... ... @@ -1,0 +1,1 @@ 1 +66.9 KB - Content
- XinjieXDsuccessprompt.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.AiXia - Size
-
... ... @@ -1,0 +1,1 @@ 1 +2.5 KB - Content