Changes for page 1 Communication
Last modified by Hunter on 2024/07/01 10:54
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 0 added, 7 removed)
Details
- Page properties
-
- Content
-
... ... @@ -378,7 +378,7 @@ 378 378 The communication port is selected as Ethernet, the device type is selected as Allen-Bradley, the protocol is Allen-BradleyMicro850_FreeTag EthemetIP, and the IP is the internal IP address of the L1769 PLC. The port number is 44818. 379 379 ))) 380 380 381 -[[image:image-20220 824164346-1.png]]381 +[[image:image-20220714162814-10.png]] 382 382 383 383 384 384 ((( ... ... @@ -431,7 +431,7 @@ 431 431 [[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communication%20with%20S7-200%20Smart.zip]] 432 432 433 433 434 -== **S7-300 Ethernet Protocol** == 434 +== ** S7-300 Ethernet Protocol** == 435 435 436 436 Supported Series: Siemens S7-300 series PLC 437 437 ... ... @@ -483,7 +483,7 @@ 483 483 484 484 [[image:image-20220824161345-1.png]] 485 485 486 -** 4)Cable Wiring**486 +**Cable Wiring** 487 487 488 488 [[image:image-20220824161450-2.png]] 489 489 ))) ... ... @@ -493,205 +493,12 @@ 493 493 494 494 [[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communicate%20with%20S7-1200%20via%20Ehernet.zip]] 495 495 496 -== **S7-XXX Ethernet Protocol** == 497 - 498 -Supported Series: Siemens S7-400, S7-1200 and S7-1500 499 - 500 -**1)PLC Setting** 501 - 502 -|=**Items**|=**Settings**|=**Note** 503 -|Protocol|Siemens S7-XXX| 504 -|Connection|Ethernet| 505 -|Port No.|102| 506 -|Device No.|Slot (Default 1 for S7-1500/ 2 for S7-1200/ 3 for S7-400)| 507 -|HMI No.|Rack (Default as 0)| 508 - 509 -Slot from TIA Portal is equal to Device No. of V-net 510 - 511 -Rack from TIA Portal is equal to HMI No. of V-net 512 - 513 -[[image:image-20220824162459-3.png]] 514 - 515 -[[image:image-20220824163305-2.png]] 516 - 517 -**2)Address List** 518 - 519 -|**Type**|**Device register**|**HMI register**|**Format**|**Range**|**Note** 520 -|(% rowspan="4" %)Bit|I|I|M d.o|((( 521 -d:0~-~-9999 522 - 523 -o:0-7 524 -)))| 525 -|Q|Q|Q d.o|((( 526 -d:0~-~-9999 527 - 528 -o:0-7 529 -)))| 530 -|M|M|M d.o|((( 531 -d:0~-~-9999 532 - 533 -o:0-7 534 -)))| 535 -|DB0.DB-DB99.DB|DBxDB|DBxDBnndddd.o|((( 536 -nn:0-9999, 537 - 538 -dddd:0-9999, 539 - 540 -o:0-7 541 -)))|((( 542 -nn:DB No. 543 - 544 -dddd:address value 545 - 546 -o: digit address 547 -))) 548 -|(% rowspan="8" %)Word|M|MB|MB d|d:0-99999| 549 -|M|MW|MW d|d:0-99999|((( 550 -MW0=MB(0~~1) 551 - 552 -MW2=MB(2~~3) 553 - 554 -Address value is a multiple of 2 555 -))) 556 -|M|MD|MD d|d:0-99999|((( 557 -MD0=MB(0~~3) 558 - 559 -MD4=MB(4~~7) 560 - 561 -Address value is a multiple of 4 562 -))) 563 -|I|IW|IW d|d:0-99999| 564 -|Q|QW|QW d|d:0-99999| 565 -|DB0.DB-DB99.DB|DBxDBB|DBxDBBnndddd|((( 566 -nn:0-9999 567 - 568 -dddd:0-9999 569 -)))|((( 570 -nn:DB No. 571 - 572 -dddd:address value 573 -))) 574 -|DB0.DB-DB99.DB|DBxDBW|DBxDBWnndddd|((( 575 -nn:0-9999 576 - 577 -dddd:0-9999 578 -)))|((( 579 -nn:DB No. 580 - 581 -dddd:address value 582 - 583 -Address value is a multiple of 2 584 -))) 585 -|DB0.DB-DB99.DB|DBxDBD|DBxDBDnndddd|((( 586 -nn:0-9999 587 - 588 -dddd:0-9999 589 -)))|((( 590 -nn:DB No. 591 - 592 -dddd:address value 593 - 594 -Address value is a multiple of 4 595 -))) 596 - 597 -**3)Configure the communication protocol** 598 - 599 -[[image:image-20220824163448-3.png]] 600 - 601 -**✎Note:** 602 - 603 -* The S7-1200 supports simultaneous connection of three devices, so the driver supports simultaneous access to PLC by three V-BOX. 604 -* V-BOX access PLC, use S7 protocol, access PLC TSAP 02.01 (s7-1200 PROFINET interface only supports three connections, the default support), detailed reference to the system manual of S7-1200. 605 - 606 -**4)Cable Wiring** 607 - 608 -[[image:image-20220824162342-2.png]] 609 - 610 - 611 611 = **Mitsubishi PLC** = 612 612 613 -== **FX Series Protocol** == 498 +== **Mitsubishi FX Series Protocol** == 614 614 615 615 [[download link>>url:https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communicate%20with%20Mitsubishi%20FX%20Series.zip]] 616 616 617 - 618 -== **FX5U Ethernet Protocol** == 619 - 620 -Mitsubishi FX5U series PLC 621 - 622 -**HMI Settings** 623 - 624 -|**Items**|**Settings**|**Note** 625 -|Protocol|Mitsubishi FX5U| 626 -|Connection|Ethernet| 627 -|Port No.|5002|Must be the same as the PLC setting 628 -|PLC station No.|0| 629 - 630 -**Address List** 631 - 632 -|**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note** 633 -|(% rowspan="15" %)Bit|X|X|X o|0~~303237| 634 -|Y|Y|Y o|0~~303237| 635 -|M|M|M d|0~~99999| 636 -|B|B|B h|0~~7FFF| 637 -|F|F|F d|0~~32767| 638 -|SB|SB|SB h|0~~7FFF| 639 -|TS|TS|TS d|0~~1023| 640 -|TC|TC|TC d|0~~1023| 641 -|STS|STS|STS d|0~~1023| 642 -|STC|STC|STS d|0~~1023| 643 -|CS|CS|CS d|0~~1023| 644 -|CC|CC|CC d|0~~1023| 645 -|SM|SM|SM d|0~~9999| 646 -|L|L|L d|0~~32767| 647 -|S|S|S d|0~~4095| 648 -|(% rowspan="9" %)Word|W|W|W h|0~~3FF| 649 -|TN|TN|TN d|0~~1023| 650 -|STN|STN|STN d|0~~1023| 651 -|CN|CN|CN d|0~~1023| 652 -|R|R|R d|0~~32767| 653 -|SW|SW|SW h|0~~7FFF| 654 -|Z|Z|Z d|0~~23| 655 -|D|D|D d|0~~7999| 656 -|SD|SD|SD d|0~~11999| 657 - 658 -**PLC Settings (GX Works 3)** 659 - 660 -Find the [Ethernet port] in the navigation area. 661 - 662 -(% style="text-align:center" %) 663 -[[image:12.PLC Protocol_html_8e8f85ace087346c.png||data-xwiki-image-style-alignment="center" height="593" width="300" class="img-thumbnail"]] 664 - 665 -Select [Own Node Settings] in the [Setting Item List]; 666 - 667 -Set [IP Address], [Subnet Mask], [Default Gateway]; 668 - 669 -Click [Detailed Settings] into [Ethernet Configuration (Built-in Ethernet Port)] windows; 670 - 671 -(% style="text-align:center" %) 672 -[[image:12.PLC Protocol_html_5d98495052c8c10e.png||data-xwiki-image-style-alignment="center" height="339" width="600" class="img-thumbnail"]] 673 - 674 -Select [SLMP Connection Module] and add into host station as below picture shows; 675 - 676 -Set Port number as 5002 (this is necessary settings); 677 - 678 -Click [Close with Reflecting the Setting] to save and close window; 679 - 680 -(% style="text-align:center" %) 681 -[[image:12.PLC Protocol_html_14b489fdc6c6589d.png||data-xwiki-image-style-alignment="center" height="350" width="600" class="img-thumbnail"]] 682 - 683 -Click [Apply] to completed Etherenet settings; 684 - 685 -Switch to the [On line data operation] interface as below, check the item and click [Execute] to download. 686 - 687 -(% style="text-align:center" %) 688 -[[image:12.PLC Protocol_html_c93025a968a8a9e7.png||data-xwiki-image-style-alignment="center" height="434" width="600" class="img-thumbnail"]] 689 - 690 -**Cable Wiring** 691 - 692 -(% style="text-align:center" %) 693 -[[image:12.PLC Protocol_html_2297240b57346b2a.png||data-xwiki-image-style-alignment="center" height="170" width="401" class="img-thumbnail"]] 694 - 695 695 = **Delta PLC** = 696 696 697 697 == **DVP Ethernet Protocol** ==
- image-20220824162339-1.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Ben - Size
-
... ... @@ -1,1 +1,0 @@ 1 -107.1 KB - Content
- image-20220824162342-2.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Ben - Size
-
... ... @@ -1,1 +1,0 @@ 1 -107.1 KB - Content
- image-20220824162459-3.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Ben - Size
-
... ... @@ -1,1 +1,0 @@ 1 -32.6 KB - Content
- image-20220824163110-1.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Ben - Size
-
... ... @@ -1,1 +1,0 @@ 1 -127.3 KB - Content
- image-20220824163305-2.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Ben - Size
-
... ... @@ -1,1 +1,0 @@ 1 -127.5 KB - Content
- image-20220824163448-3.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Ben - Size
-
... ... @@ -1,1 +1,0 @@ 1 -42.8 KB - Content
- image-20220824164346-1.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Ben - Size
-
... ... @@ -1,1 +1,0 @@ 1 -43.2 KB - Content