Changes for page 1 Communication

Last modified by Hunter on 2024/07/01 10:54

From version 100.1
edited by Ben
on 2022/08/24 17:03
Change comment: There is no comment for this version
To version 98.1
edited by Ben
on 2022/08/24 16:57
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -431,7 +431,7 @@
431 431  [[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communication%20with%20S7-200%20Smart.zip]]
432 432  
433 433  
434 -== **S7-300 Ethernet Protocol** ==
434 +== ** S7-300 Ethernet Protocol** ==
435 435  
436 436  Supported Series: Siemens S7-300 series PLC
437 437  
... ... @@ -610,88 +610,10 @@
610 610  
611 611  = **Mitsubishi PLC** =
612 612  
613 -== **FX Series Protocol** ==
613 +== **Mitsubishi FX Series Protocol** ==
614 614  
615 615  [[download link>>url:https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communicate%20with%20Mitsubishi%20FX%20Series.zip]]
616 616  
617 -
618 -== **FX5U Ethernet Protocol** ==
619 -
620 -Mitsubishi FX5U series PLC
621 -
622 -**HMI Settings**
623 -
624 -|**Items**|**Settings**|**Note**
625 -|Protocol|Mitsubishi FX5U|
626 -|Connection|Ethernet|
627 -|Port No.|5002|Must be the same as the PLC setting
628 -|PLC station No.|0|
629 -
630 -**Address List**
631 -
632 -|**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note**
633 -|(% rowspan="15" %)Bit|X|X|X o|0~~303237|
634 -|Y|Y|Y o|0~~303237|
635 -|M|M|M d|0~~99999|
636 -|B|B|B h|0~~7FFF|
637 -|F|F|F d|0~~32767|
638 -|SB|SB|SB h|0~~7FFF|
639 -|TS|TS|TS d|0~~1023|
640 -|TC|TC|TC d|0~~1023|
641 -|STS|STS|STS d|0~~1023|
642 -|STC|STC|STS d|0~~1023|
643 -|CS|CS|CS d|0~~1023|
644 -|CC|CC|CC d|0~~1023|
645 -|SM|SM|SM d|0~~9999|
646 -|L|L|L d|0~~32767|
647 -|S|S|S d|0~~4095|
648 -|(% rowspan="9" %)Word|W|W|W h|0~~3FF|
649 -|TN|TN|TN d|0~~1023|
650 -|STN|STN|STN d|0~~1023|
651 -|CN|CN|CN d|0~~1023|
652 -|R|R|R d|0~~32767|
653 -|SW|SW|SW h|0~~7FFF|
654 -|Z|Z|Z d|0~~23|
655 -|D|D|D d|0~~7999|
656 -|SD|SD|SD d|0~~11999|
657 -
658 -**PLC Settings (GX Works 3)**
659 -
660 -Find the [Ethernet port] in the navigation area.
661 -
662 -(% style="text-align:center" %)
663 -[[image:12.PLC Protocol_html_8e8f85ace087346c.png||data-xwiki-image-style-alignment="center" height="593" width="300" class="img-thumbnail"]]
664 -
665 -Select [Own Node Settings] in the [Setting Item List];
666 -
667 -Set [IP Address], [Subnet Mask], [Default Gateway];
668 -
669 -Click [Detailed Settings] into [Ethernet Configuration (Built-in Ethernet Port)] windows;
670 -
671 -(% style="text-align:center" %)
672 -[[image:12.PLC Protocol_html_5d98495052c8c10e.png||data-xwiki-image-style-alignment="center" height="339" width="600" class="img-thumbnail"]]
673 -
674 -Select [SLMP Connection Module] and add into host station as below picture shows;
675 -
676 -Set Port number as 5002 (this is necessary settings);
677 -
678 -Click [Close with Reflecting the Setting] to save and close window;
679 -
680 -(% style="text-align:center" %)
681 -[[image:12.PLC Protocol_html_14b489fdc6c6589d.png||data-xwiki-image-style-alignment="center" height="350" width="600" class="img-thumbnail"]]
682 -
683 -Click [Apply] to completed Etherenet settings;
684 -
685 -Switch to the [On line data operation] interface as below, check the item and click [Execute] to download.
686 -
687 -(% style="text-align:center" %)
688 -[[image:12.PLC Protocol_html_c93025a968a8a9e7.png||data-xwiki-image-style-alignment="center" height="434" width="600" class="img-thumbnail"]]
689 -
690 -**Cable Wiring**
691 -
692 -(% style="text-align:center" %)
693 -[[image:12.PLC Protocol_html_2297240b57346b2a.png||data-xwiki-image-style-alignment="center" height="170" width="401" class="img-thumbnail"]]
694 -
695 695  = **Delta PLC** =
696 696  
697 697  == **DVP Ethernet Protocol** ==