Changes for page 1 Communication
Last modified by Hunter on 2024/07/01 10:54
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 0 added, 1 removed)
Details
- Page properties
-
- Content
-
... ... @@ -378,7 +378,7 @@ 378 378 The communication port is selected as Ethernet, the device type is selected as Allen-Bradley, the protocol is Allen-BradleyMicro850_FreeTag EthemetIP, and the IP is the internal IP address of the L1769 PLC. The port number is 44818. 379 379 ))) 380 380 381 -[[image:image-20220 824164346-1.png]]381 +[[image:image-20220714162814-10.png]] 382 382 383 383 384 384 ((( ... ... @@ -431,7 +431,7 @@ 431 431 [[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communication%20with%20S7-200%20Smart.zip]] 432 432 433 433 434 -== **S7-300 Ethernet Protocol** == 434 +== ** S7-300 Ethernet Protocol** == 435 435 436 436 Supported Series: Siemens S7-300 series PLC 437 437 ... ... @@ -483,7 +483,7 @@ 483 483 484 484 [[image:image-20220824161345-1.png]] 485 485 486 -** 4)Cable Wiring**486 +**Cable Wiring** 487 487 488 488 [[image:image-20220824161450-2.png]] 489 489 ))) ... ... @@ -607,90 +607,12 @@ 607 607 608 608 [[image:image-20220824162342-2.png]] 609 609 610 - 611 611 = **Mitsubishi PLC** = 612 612 613 -== **FX 3USerialProtocol** ==612 +== **Mitsubishi FX Series Protocol** == 614 614 615 615 [[download link>>url:https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communicate%20with%20Mitsubishi%20FX%20Series.zip]] 616 616 617 -== **FX5U Ethernet Protocol** == 618 - 619 -Mitsubishi FX5U series PLC 620 - 621 -**HMI Settings** 622 - 623 -|**Items**|**Settings**|**Note** 624 -|Protocol|Mitsubishi FX5U| 625 -|Connection|Ethernet| 626 -|Port No.|5002|Must be the same as the PLC setting 627 -|PLC station No.|0| 628 - 629 -**Address List** 630 - 631 -|**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note** 632 -|(% rowspan="15" %)Bit|X|X|X o|0~~303237| 633 -|Y|Y|Y o|0~~303237| 634 -|M|M|M d|0~~99999| 635 -|B|B|B h|0~~7FFF| 636 -|F|F|F d|0~~32767| 637 -|SB|SB|SB h|0~~7FFF| 638 -|TS|TS|TS d|0~~1023| 639 -|TC|TC|TC d|0~~1023| 640 -|STS|STS|STS d|0~~1023| 641 -|STC|STC|STS d|0~~1023| 642 -|CS|CS|CS d|0~~1023| 643 -|CC|CC|CC d|0~~1023| 644 -|SM|SM|SM d|0~~9999| 645 -|L|L|L d|0~~32767| 646 -|S|S|S d|0~~4095| 647 -|(% rowspan="9" %)Word|W|W|W h|0~~3FF| 648 -|TN|TN|TN d|0~~1023| 649 -|STN|STN|STN d|0~~1023| 650 -|CN|CN|CN d|0~~1023| 651 -|R|R|R d|0~~32767| 652 -|SW|SW|SW h|0~~7FFF| 653 -|Z|Z|Z d|0~~23| 654 -|D|D|D d|0~~7999| 655 -|SD|SD|SD d|0~~11999| 656 - 657 -**PLC Settings (GX Works 3)** 658 - 659 -Find the [Ethernet port] in the navigation area. 660 - 661 -(% style="text-align:center" %) 662 -[[image:12.PLC Protocol_html_8e8f85ace087346c.png||data-xwiki-image-style-alignment="center" height="593" width="300" class="img-thumbnail"]] 663 - 664 -Select [Own Node Settings] in the [Setting Item List]; 665 - 666 -Set [IP Address], [Subnet Mask], [Default Gateway]; 667 - 668 -Click [Detailed Settings] into [Ethernet Configuration (Built-in Ethernet Port)] windows; 669 - 670 -(% style="text-align:center" %) 671 -[[image:12.PLC Protocol_html_5d98495052c8c10e.png||data-xwiki-image-style-alignment="center" height="339" width="600" class="img-thumbnail"]] 672 - 673 -Select [SLMP Connection Module] and add into host station as below picture shows; 674 - 675 -Set Port number as 5002 (this is necessary settings); 676 - 677 -Click [Close with Reflecting the Setting] to save and close window; 678 - 679 -(% style="text-align:center" %) 680 -[[image:12.PLC Protocol_html_14b489fdc6c6589d.png||data-xwiki-image-style-alignment="center" height="350" width="600" class="img-thumbnail"]] 681 - 682 -Click [Apply] to completed Etherenet settings; 683 - 684 -Switch to the [On line data operation] interface as below, check the item and click [Execute] to download. 685 - 686 -(% style="text-align:center" %) 687 -[[image:12.PLC Protocol_html_c93025a968a8a9e7.png||data-xwiki-image-style-alignment="center" height="434" width="600" class="img-thumbnail"]] 688 - 689 -**Cable Wiring** 690 - 691 -(% style="text-align:center" %) 692 -[[image:12.PLC Protocol_html_2297240b57346b2a.png||data-xwiki-image-style-alignment="center" height="170" width="401" class="img-thumbnail"]] 693 - 694 694 = **Delta PLC** = 695 695 696 696 == **DVP Ethernet Protocol** ==
- image-20220824164346-1.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Ben - Size
-
... ... @@ -1,1 +1,0 @@ 1 -43.2 KB - Content