... ... @@ -378,7 +378,7 @@
378 378  The communication port is selected as Ethernet, the device type is selected as Allen-Bradley, the protocol is Allen-BradleyMicro850_FreeTag EthemetIP, and the IP is the internal IP address of the L1769 PLC. The port number is 44818.
379 379  )))
380 380  
381 -[[image:image-20220824164346-1.png]]
381 +[[image:image-20220714162814-10.png]]
382 382  
383 383  
384 384  (((
... ... @@ -431,7 +431,7 @@
431 431  [[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communication%20with%20S7-200%20Smart.zip]]
432 432  
433 433  
434 -== **S7-300 Ethernet Protocol** ==
434 +== ** S7-300 Ethernet Protocol** ==
435 435  
436 436  Supported Series: Siemens S7-300 series PLC
437 437  
... ... @@ -483,7 +483,7 @@
483 483  
484 484  [[image:image-20220824161345-1.png]]
485 485  
486 -**4)Cable Wiring**
486 +**Cable Wiring**
487 487  
488 488  [[image:image-20220824161450-2.png]]
489 489  )))
... ... @@ -497,7 +497,7 @@
497 497  
498 498  Supported Series: Siemens S7-400, S7-1200 and S7-1500
499 499  
500 -**1)PLC Setting**
500 +**HMI Setting**
501 501  
502 502  |=**Items**|=**Settings**|=**Note**
503 503  |Protocol|Siemens S7-XXX|
... ... @@ -506,16 +506,14 @@
506 506  |Device No.|Slot (Default 1 for S7-1500/ 2 for S7-1200/ 3 for S7-400)|
507 507  |HMI No.|Rack (Default as 0)|
508 508  
509 -Slot from TIA Portal is equal to Device No. of V-net
509 +Slot from TIA Portal is equal to Device No. of PIStudio
510 510  
511 -Rack from TIA Portal is equal to HMI No. of V-net
511 +Rack from TIA Portal is equal to HMI No. of PIStudio
512 512  
513 513  [[image:image-20220824162459-3.png]]
514 514  
515 -[[image:image-20220824163305-2.png]]
515 +**Address List**
516 516  
517 -**2)Address List**
518 -
519 519  |**Type**|**Device register**|**HMI register**|**Format**|**Range**|**Note**
520 520  |(% rowspan="4" %)Bit|I|I|M d.o|(((
521 521  d:0~-~-9999
... ... @@ -594,109 +594,33 @@
594 594  Address value is a multiple of 4
595 595  )))
596 596  
597 -**3)Configure the communication protocol**
595 +**Communication Settings**
598 598  
599 -[[image:image-20220824163448-3.png]]
597 +Enable HMI Ethernet in [Project Settings];
600 600  
601 -**✎Note:**
602 -
603 -* The S7-1200 supports simultaneous connection of three devices, so the driver supports simultaneous access to PLC by three V-BOX.
604 -* V-BOX access PLC, use S7 protocol, access PLC TSAP 02.01 (s7-1200 PROFINET interface only supports three connections, the default support), detailed reference to the system manual of S7-1200.
605 -
606 -**4)Cable Wiring**
607 -
608 -[[image:image-20220824162342-2.png]]
609 -
610 -
611 -= **Mitsubishi PLC** =
612 -
613 -== **FX2N Serial Protocol** ==
614 -
615 -
616 -
617 -== **FX3U Serial Protocol** ==
618 -
619 -
620 -== **FX5U Serial Protocol** ==
621 -
622 -
623 -== **FX5U Ethernet Protocol** ==
624 -
625 -Mitsubishi FX5U series PLC
626 -
627 -**HMI Settings**
628 -
629 -|**Items**|**Settings**|**Note**
630 -|Protocol|Mitsubishi FX5U|
631 -|Connection|Ethernet|
632 -|Port No.|5002|Must be the same as the PLC setting
633 -|PLC station No.|0|
634 -
635 -**Address List**
636 -
637 -|**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note**
638 -|(% rowspan="15" %)Bit|X|X|X o|0~~303237|
639 -|Y|Y|Y o|0~~303237|
640 -|M|M|M d|0~~99999|
641 -|B|B|B h|0~~7FFF|
642 -|F|F|F d|0~~32767|
643 -|SB|SB|SB h|0~~7FFF|
644 -|TS|TS|TS d|0~~1023|
645 -|TC|TC|TC d|0~~1023|
646 -|STS|STS|STS d|0~~1023|
647 -|STC|STC|STS d|0~~1023|
648 -|CS|CS|CS d|0~~1023|
649 -|CC|CC|CC d|0~~1023|
650 -|SM|SM|SM d|0~~9999|
651 -|L|L|L d|0~~32767|
652 -|S|S|S d|0~~4095|
653 -|(% rowspan="9" %)Word|W|W|W h|0~~3FF|
654 -|TN|TN|TN d|0~~1023|
655 -|STN|STN|STN d|0~~1023|
656 -|CN|CN|CN d|0~~1023|
657 -|R|R|R d|0~~32767|
658 -|SW|SW|SW h|0~~7FFF|
659 -|Z|Z|Z d|0~~23|
660 -|D|D|D d|0~~7999|
661 -|SD|SD|SD d|0~~11999|
662 -
663 -**PLC Settings (GX Works 3)**
664 -
665 -Find the [Ethernet port] in the navigation area.
666 -
667 667  (% style="text-align:center" %)
668 -[[image:12.PLC Protocol_html_8e8f85ace087346c.png||data-xwiki-image-style-alignment="center" height="593" width="300" class="img-thumbnail"]]
600 +[[image:12.PLC Protocol_html_43b671f18153910d.png||data-xwiki-image-style-alignment="center" height="107" width="405" class="img-rounded img-thumbnail"]]
669 669  
670 -Select [Own Node Settings] in the [Setting Item List];
602 +Set PLC IP in [Device IP] settings;
671 671  
672 -Set [IP Address], [Subnet Mask], [Default Gateway];
673 -
674 -Click [Detailed Settings] into [Ethernet Configuration (Built-in Ethernet Port)] windows;
675 -
676 676  (% style="text-align:center" %)
677 -[[image:12.PLC Protocol_html_5d98495052c8c10e.png||data-xwiki-image-style-alignment="center" height="339" width="600" class="img-thumbnail"]]
605 +[[image:12.PLC Protocol_html_f7b3eb9abda33833.png||data-xwiki-image-style-alignment="center" height="190" width="554" class="img-thumbnail"]]
678 678  
679 -Select [SLMP Connection Module] and add into host station as below picture shows;
607 +**✎Note:**
680 680  
681 -Set Port number as 5002 (this is necessary settings);
609 +* The S7-1200 supports simultaneous connection of three devices, so the driver supports simultaneous access to PLC by three touch screens.
610 +* HMI access PLC, use S7 protocol, access PLC TSAP 02.01 (s7-1200 PROFINET interface only supports three connections, the default support), detailed reference to the system manual of S7-1200.
682 682  
683 -Click [Close with Reflecting the Setting] to save and close window;
612 +**Cable Wiring**
684 684  
685 -(% style="text-align:center" %)
686 -[[image:12.PLC Protocol_html_14b489fdc6c6589d.png||data-xwiki-image-style-alignment="center" height="350" width="600" class="img-thumbnail"]]
614 +[[image:image-20220824162342-2.png]]
687 687  
688 -Click [Apply] to completed Etherenet settings;
616 += **Mitsubishi PLC** =
689 689  
690 -Switch to the [On line data operation] interface as below, check the item and click [Execute] to download.
618 +== **Mitsubishi FX Series Protocol** ==
691 691  
692 -(% style="text-align:center" %)
693 -[[image:12.PLC Protocol_html_c93025a968a8a9e7.png||data-xwiki-image-style-alignment="center" height="434" width="600" class="img-thumbnail"]]
620 +[[download link>>url:https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communicate%20with%20Mitsubishi%20FX%20Series.zip]]
694 694  
695 -**Cable Wiring**
696 -
697 -(% style="text-align:center" %)
698 -[[image:12.PLC Protocol_html_2297240b57346b2a.png||data-xwiki-image-style-alignment="center" height="170" width="401" class="img-thumbnail"]]
699 -
700 700  = **Delta PLC** =
701 701  
702 702  == **DVP Ethernet Protocol** ==
image-20220824163110-1.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Ben
Size
... ... @@ -1,1 +1,0 @@
1 -127.3 KB
Content
image-20220824163305-2.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Ben
Size
... ... @@ -1,1 +1,0 @@
1 -127.5 KB
Content
image-20220824163448-3.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Ben
Size
... ... @@ -1,1 +1,0 @@
1 -42.8 KB
Content
image-20220824164346-1.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Ben
Size
... ... @@ -1,1 +1,0 @@
1 -43.2 KB
Content