Changes for page 1 Communication
Last modified by Hunter on 2024/07/01 10:54
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 0 added, 1 removed)
Details
- Page properties
-
- Content
-
... ... @@ -378,7 +378,7 @@ 378 378 The communication port is selected as Ethernet, the device type is selected as Allen-Bradley, the protocol is Allen-BradleyMicro850_FreeTag EthemetIP, and the IP is the internal IP address of the L1769 PLC. The port number is 44818. 379 379 ))) 380 380 381 -[[image:image-20220 824164346-1.png]]381 +[[image:image-20220714162814-10.png]] 382 382 383 383 384 384 ((( ... ... @@ -431,7 +431,7 @@ 431 431 [[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communication%20with%20S7-200%20Smart.zip]] 432 432 433 433 434 -== **S7-300 Ethernet Protocol** == 434 +== ** S7-300 Ethernet Protocol** == 435 435 436 436 Supported Series: Siemens S7-300 series PLC 437 437 ... ... @@ -607,96 +607,12 @@ 607 607 608 608 [[image:image-20220824162342-2.png]] 609 609 610 - 611 611 = **Mitsubishi PLC** = 612 612 613 -== **FX 2NSerialProtocol** ==612 +== **Mitsubishi FX Series Protocol** == 614 614 614 +[[download link>>url:https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communicate%20with%20Mitsubishi%20FX%20Series.zip]] 615 615 616 - 617 -== **FX3U Serial Protocol** == 618 - 619 - 620 -== **FX5U Serial Protocol** == 621 - 622 - 623 -== **FX5U Ethernet Protocol** == 624 - 625 -Mitsubishi FX5U series PLC 626 - 627 -**HMI Settings** 628 - 629 -|**Items**|**Settings**|**Note** 630 -|Protocol|Mitsubishi FX5U| 631 -|Connection|Ethernet| 632 -|Port No.|5002|Must be the same as the PLC setting 633 -|PLC station No.|0| 634 - 635 -**Address List** 636 - 637 -|**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note** 638 -|(% rowspan="15" %)Bit|X|X|X o|0~~303237| 639 -|Y|Y|Y o|0~~303237| 640 -|M|M|M d|0~~99999| 641 -|B|B|B h|0~~7FFF| 642 -|F|F|F d|0~~32767| 643 -|SB|SB|SB h|0~~7FFF| 644 -|TS|TS|TS d|0~~1023| 645 -|TC|TC|TC d|0~~1023| 646 -|STS|STS|STS d|0~~1023| 647 -|STC|STC|STS d|0~~1023| 648 -|CS|CS|CS d|0~~1023| 649 -|CC|CC|CC d|0~~1023| 650 -|SM|SM|SM d|0~~9999| 651 -|L|L|L d|0~~32767| 652 -|S|S|S d|0~~4095| 653 -|(% rowspan="9" %)Word|W|W|W h|0~~3FF| 654 -|TN|TN|TN d|0~~1023| 655 -|STN|STN|STN d|0~~1023| 656 -|CN|CN|CN d|0~~1023| 657 -|R|R|R d|0~~32767| 658 -|SW|SW|SW h|0~~7FFF| 659 -|Z|Z|Z d|0~~23| 660 -|D|D|D d|0~~7999| 661 -|SD|SD|SD d|0~~11999| 662 - 663 -**PLC Settings (GX Works 3)** 664 - 665 -Find the [Ethernet port] in the navigation area. 666 - 667 -(% style="text-align:center" %) 668 -[[image:12.PLC Protocol_html_8e8f85ace087346c.png||data-xwiki-image-style-alignment="center" height="593" width="300" class="img-thumbnail"]] 669 - 670 -Select [Own Node Settings] in the [Setting Item List]; 671 - 672 -Set [IP Address], [Subnet Mask], [Default Gateway]; 673 - 674 -Click [Detailed Settings] into [Ethernet Configuration (Built-in Ethernet Port)] windows; 675 - 676 -(% style="text-align:center" %) 677 -[[image:12.PLC Protocol_html_5d98495052c8c10e.png||data-xwiki-image-style-alignment="center" height="339" width="600" class="img-thumbnail"]] 678 - 679 -Select [SLMP Connection Module] and add into host station as below picture shows; 680 - 681 -Set Port number as 5002 (this is necessary settings); 682 - 683 -Click [Close with Reflecting the Setting] to save and close window; 684 - 685 -(% style="text-align:center" %) 686 -[[image:12.PLC Protocol_html_14b489fdc6c6589d.png||data-xwiki-image-style-alignment="center" height="350" width="600" class="img-thumbnail"]] 687 - 688 -Click [Apply] to completed Etherenet settings; 689 - 690 -Switch to the [On line data operation] interface as below, check the item and click [Execute] to download. 691 - 692 -(% style="text-align:center" %) 693 -[[image:12.PLC Protocol_html_c93025a968a8a9e7.png||data-xwiki-image-style-alignment="center" height="434" width="600" class="img-thumbnail"]] 694 - 695 -**Cable Wiring** 696 - 697 -(% style="text-align:center" %) 698 -[[image:12.PLC Protocol_html_2297240b57346b2a.png||data-xwiki-image-style-alignment="center" height="170" width="401" class="img-thumbnail"]] 699 - 700 700 = **Delta PLC** = 701 701 702 702 == **DVP Ethernet Protocol** ==
- image-20220824164346-1.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Ben - Size
-
... ... @@ -1,1 +1,0 @@ 1 -43.2 KB - Content