... ... @@ -1,10 +1,10 @@
1 -= (% style="color:inherit; font-family:inherit" %)**WECON PLC**(%%) =
1 += Create communication with WECON PLC =
2 2  
3 -== **LX3V Serial Protocol** ==
3 +== **LX3V Serial Protocol** ==
4 4  
5 -Supported series: WECON LX2V/ LX2E/ LX3V/LX3VP/LX3VE/LX3VM
5 +Supported series: Wecon LX2V/ LX2E/ LX3V/LX3VP/LX3VE/LX3VM
6 6  
7 -**1)PLC Settings**
7 +**1)V-BOX setting**
8 8  
9 9  |**Item**|**Settings**|**Note**
10 10  |Protocol|WECON LX2V/ LX2E/ LX3V/LX3VP/LX3VE/LX3VM|
... ... @@ -15,8 +15,9 @@
15 15  |Stop bit|1|
16 16  |PLC station No.|1|
17 17  
18 -**2)PLC Address List**
18 +**2)Address List**
19 19  
20 +
20 20  |**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note**
21 21  |(% rowspan="6" %)Bit|X|X|Xo|0~~303237|
22 22  |Y|Y|Y o|0~~303237|
... ... @@ -35,9 +35,9 @@
35 35  
36 36  **3)Configure the communication protocol**
37 37  
38 -[[image:image-20220824152217-1.png]]
39 +[[image:image-20220824152217-1.png||alt="图片-20220824152217-1.png"]]
39 39  
40 -**4)hardware connection**
41 +**4)Cable Wiring**
41 41  
42 42  * **RS422**
43 43  
... ... @@ -175,7 +175,7 @@
175 175  
176 176  The above are all the steps for establishing ethernet communication between V-BOX with LX5V PLC.
177 177  
178 -= **Rockwell PLC** =
179 += Create communication with **Rockwell PLC** =
179 179  
180 180  == (% id="cke_bm_5621S" style="display:none" %)** **(%%)**MicroLogix Protocol** ==
181 181  
... ... @@ -216,7 +216,7 @@
216 216  
217 217  [[image:image-20220824110724-1.png]]
218 218  
219 -== **CompactLogix Protocol** ==
220 +== **Micro850_FreeTag Protocol** ==
220 220  
221 221  (((
222 222  (((
... ... @@ -355,7 +355,7 @@
355 355  
356 356  (((
357 357  (((
358 -Open VNET client software → add device. As shown in the figure below, click "+" in the order of steps, and the Add Device window will pop up, enter the device machine code/product code, device password, and device alias to add the device.   [[image:image-20220714162752-8.png]]
359 +Open VNET client software → add device. As shown in the figure below, click "+" in the order of steps, and the Add Device window will pop up, enter the device machine code/product code, device password, and device alias to add the device.   [[image:image-20220714162752-8.png]]
359 359  )))
360 360  
361 361  
... ... @@ -424,7 +424,7 @@
424 424  [[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Allen-Bradley%20Ethernet%20DF1.zip]]
425 425  
426 426  
427 -= **Siemens PLC** =
428 += Create communication with **Siemens PLC** =
428 428  
429 429  == **S7-200 Smart Ethernet Protocol** ==
430 430  
... ... @@ -607,9 +607,8 @@
607 607  
608 608  [[image:image-20220824162342-2.png]]
609 609  
611 += Create communication with **Mitsubishi PLC** =
610 610  
611 -= **Mitsubishi PLC** =
612 -
613 613  == **FX1S,1N,2N Serial Protocol** ==
614 614  
615 615  Supported Series: Mitsubishi FX1S, FX1N, FX2N series
... ... @@ -708,7 +708,7 @@
708 708  
709 709  Mitsubishi FX5U series PLC
710 710  
711 -**HMI Settings**
711 +**1)V-BOX Settings**
712 712  
713 713  |**Item**|**Settings**|**Note**
714 714  |Protocol|Mitsubishi FX5U|
... ... @@ -719,7 +719,7 @@
719 719  |Stop bit|1|
720 720  |PLC station No.|1~~255|Need to be the same as PLC settings
721 721  
722 -**Address List**
722 +**2)Address List**
723 723  
724 724  |**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note**
725 725  |(% rowspan="15" %)Bit|X|X|X o|0~~303237|
... ... @@ -747,7 +747,7 @@
747 747  |D|D|D d|0~~7999|
748 748  |SD|SD|SD d|0~~11999|
749 749  
750 -**PLC Settings (GX Works 3)**
750 +**3)PLC Settings (GX Works 3)**
751 751  
752 752  Create a blank FX5U project
753 753  
... ... @@ -773,24 +773,24 @@
773 773  
774 774  Done.
775 775  
776 -**Cable Wiring**
776 +**4)Configure the communication protocol**
777 777  
778 -* **RS485**
778 +[[image:image-20220825104904-1.png]]
779 779  
780 -[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_d4012bdeb4ce4aae.png?width=394&height=244&rev=1.1||alt="12.PLC Protocol_html_d4012bdeb4ce4aae.png" height="244" width="394"]]
780 +**5)Cable Wiring**
781 781  
782 -[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_4bf57ad8d44eacc4.png?width=394&height=244&rev=1.1||alt="12.PLC Protocol_html_4bf57ad8d44eacc4.png" height="244" width="394"]]
783 783  
784 784  * **RS422**
785 785  
786 -[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_f8a6bebc5792960d.png?width=402&height=253&rev=1.1||alt="12.PLC Protocol_html_f8a6bebc5792960d.png" height="253" width="402"]]
785 +[[image:image-20220825105105-2.png]]
787 787  
787 +[[image:image-20220825105533-3.png]]
788 788  
789 789  == **FX5U Ethernet Protocol** ==
790 790  
791 791  Mitsubishi FX5U series PLC
792 792  
793 -**HMI Settings**
793 +**1)V-BOX Settings**
794 794  
795 795  |**Items**|**Settings**|**Note**
796 796  |Protocol|Mitsubishi FX5U|
... ... @@ -798,7 +798,7 @@
798 798  |Port No.|5002|Must be the same as the PLC setting
799 799  |PLC station No.|0|
800 800  
801 -**Address List**
801 +**2)Address List**
802 802  
803 803  |**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note**
804 804  |(% rowspan="15" %)Bit|X|X|X o|0~~303237|
... ... @@ -826,12 +826,11 @@
826 826  |D|D|D d|0~~7999|
827 827  |SD|SD|SD d|0~~11999|
828 828  
829 -**PLC Settings (GX Works 3)**
829 +**3)PLC Settings (GX Works 3)**
830 830  
831 831  Find the [Ethernet port] in the navigation area.
832 832  
833 -(% style="text-align:center" %)
834 -[[image:12.PLC Protocol_html_8e8f85ace087346c.png||data-xwiki-image-style-alignment="center" height="593" width="300" class="img-thumbnail"]]
833 +[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_8e8f85ace087346c.png?width=300&height=593&rev=1.1||alt="12.PLC Protocol_html_8e8f85ace087346c.png" height="593" width="300"]]
835 835  
836 836  Select [Own Node Settings] in the [Setting Item List];
837 837  
... ... @@ -839,8 +839,7 @@
839 839  
840 840  Click [Detailed Settings] into [Ethernet Configuration (Built-in Ethernet Port)] windows;
841 841  
842 -(% style="text-align:center" %)
843 -[[image:12.PLC Protocol_html_5d98495052c8c10e.png||data-xwiki-image-style-alignment="center" height="339" width="600" class="img-thumbnail"]]
841 +[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_5d98495052c8c10e.png?width=600&height=339&rev=1.1||alt="12.PLC Protocol_html_5d98495052c8c10e.png" height="339" width="600"]]
844 844  
845 845  Select [SLMP Connection Module] and add into host station as below picture shows;
846 846  
... ... @@ -848,66 +848,379 @@
848 848  
849 849  Click [Close with Reflecting the Setting] to save and close window;
850 850  
851 -(% style="text-align:center" %)
852 -[[image:12.PLC Protocol_html_14b489fdc6c6589d.png||data-xwiki-image-style-alignment="center" height="350" width="600" class="img-thumbnail"]]
849 +[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_14b489fdc6c6589d.png?width=600&height=350&rev=1.1||alt="12.PLC Protocol_html_14b489fdc6c6589d.png" height="350" width="600"]]
853 853  
854 854  Click [Apply] to completed Etherenet settings;
855 855  
856 856  Switch to the [On line data operation] interface as below, check the item and click [Execute] to download.
857 857  
858 -(% style="text-align:center" %)
859 -[[image:12.PLC Protocol_html_c93025a968a8a9e7.png||data-xwiki-image-style-alignment="center" height="434" width="600" class="img-thumbnail"]]
855 +[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_c93025a968a8a9e7.png?width=600&height=434&rev=1.1||alt="12.PLC Protocol_html_c93025a968a8a9e7.png" height="434" width="600"]]
860 860  
861 -**Cable Wiring**
857 +**4)Configure the communication protocol**
862 862  
863 -(% style="text-align:center" %)
864 -[[image:12.PLC Protocol_html_2297240b57346b2a.png||data-xwiki-image-style-alignment="center" height="170" width="401" class="img-thumbnail"]]
859 +[[image:image-20220825112403-1.png||alt="图片-20220825112403-1.png"]]
865 865  
866 -= **Delta PLC** =
861 +**5)电缆布线**
867 867  
863 +[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_2297240b57346b2a.png?width=401&height=170&rev=1.1||alt="12.可编程逻辑控制器Protocol_html_2297240b57346b2a.png" height="170" width="401"]]
864 +
865 +
866 +== **L02 Serial Protocol** ==
867 +
868 +Mitsubishi L02 series CPU built-in serial port.
869 +
870 +**1)V-BOX Settings**
871 +
872 +|**Item**|**Settings**|**Note**
873 +|Protocol|Mitsubishi L02|
874 +|Connection|RS422|
875 +|Baud rate|115200|
876 +|Data bit|8|
877 +|Parity|Odd|
878 +|Stop bit|1|
879 +|PLC station No.|1~~255|Need to be the same as PLC settings
880 +
881 +**2)Address List**
882 +
883 +|**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note**
884 +|Bit|X|X|X h|0~~FFFF|
885 +|Bit|Y|Y|Y h|0~~FFFF|
886 +|Bit|M|M|M d|0~~9999|
887 +|Bit|L|L|L d|0~~9999|
888 +|Bit|F|F|F d|0~~9999|
889 +|Bit|B|B|B h|0~~FFFF|
890 +|Bit|V|V|V d|0~~2047|
891 +|Bit|TC|TC|TC d|0~~9999|
892 +|Bit|SS|SS|SS d|0~~9999|
893 +|Bit|SC|SC|SC d|0~~9999|
894 +|Bit|CS|CS|CS d|0~~9999|
895 +|Bit|CC|CC|CC d|0~~9999|
896 +|Bit|SB|SB|SB h|0~~FFFF|
897 +|Bit|SM|SM|SM d|0~~2047|
898 +|Bit|STS|STS|STS d|0~~1023|
899 +|Bit|S|S|S d|0~~9999|
900 +|Bit|DX|DX|DX h|0~~FFFF|
901 +|Bit|DY|DY|DY h|0~~FFFF|
902 +|Bit|TS|TS|TS d|0~~9999|
903 +|Bit|Dbit|Dbit|Dbit d.d|0~~99999.0~~15|
904 +|Word|W|W|W h|0~~FFFF|
905 +|Word|TN|TN|TN d|0~~99999|
906 +|Word|SN|SN|SN d|0~~99999|
907 +|Word|CN|CN|CN d|0~~99999|
908 +|Word|R|R|R d|0~~99999|
909 +|Word|SW|SW|SW h|0~~FFFF|
910 +|Word|Z|Z|Z d|0~~99999|
911 +|Word|ZR|ZR|ZR h|0~~FFFF|
912 +|Word|D|D|D d|0~~99999|
913 +
914 +**3)Communication Settings**
915 +
916 +[[image:image-20220825160648-3.png]]
917 +
918 +**4)Cable Wiring**
919 +
920 +* **RS422**
921 +
922 +[[image:image-20220825161612-8.png]]
923 +
924 +[[image:image-20220825160820-4.png]]
925 +
926 +== **L02 Ethernet Protocol** ==
927 +
928 +Mitsubishi L series CPU built-in Ethernet port.
929 +
930 +**1)V-BOX Settings**
931 +
932 +|**Items**|**Settings**|**Note**
933 +|Protocol|MIT L02 CPU MELSEC|
934 +|Connection|Ethernet|
935 +|Port No.|1025|Must be the same as the PLC setting
936 +|PLC station No.|0|Must be the same as the PLC setting
937 +
938 +**2)Address List**
939 +
940 +|**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note**
941 +|Bit|X|X|X h|0~~FFFF|
942 +|Bit|Y|Y|Y h|0~~FFFF|
943 +|Bit|M|M|M d|0~~9999|
944 +|Bit|L|L|L d|0~~9999|
945 +|Bit|F|F|F d|0~~9999|
946 +|Bit|B|B|B h|0~~FFFF|
947 +|Bit|V|V|V d|0~~2047|
948 +|Bit|TC|TC|TC d|0~~9999|
949 +|Bit|SS|SS|SS d|0~~9999|
950 +|Bit|SC|SC|SC d|0~~9999|
951 +|Bit|CS|CS|CS d|0~~9999|
952 +|Bit|CC|CC|CC d|0~~9999|
953 +|Bit|SB|SB|SB h|0~~FFFF|
954 +|Bit|SM|SM|SM d|0~~2047|
955 +|Bit|STS|STS|STS d|0~~1023|
956 +|Bit|S|S|S d|0~~9999|
957 +|Bit|DX|DX|DX h|0~~FFFF|
958 +|Bit|DY|DY|DY h|0~~FFFF|
959 +|Bit|TS|TS|TS d|0~~9999|
960 +|Bit|Dbit|Dbit|Dbit d.d|0~~99999.0~~15|
961 +|Word|W|W|W h|0~~FFFF|
962 +|Word|TN|TN|TN d|0~~99999|
963 +|Word|SN|SN|SN d|0~~99999|
964 +|Word|CN|CN|CN d|0~~99999|
965 +|Word|R|R|R d|0~~99999|
966 +|Word|SW|SW|SW h|0~~FFFF|
967 +|Word|Z|Z|Z d|0~~99999|
968 +|Word|ZR|ZR|ZR h|0~~FFFF|
969 +|Word|D|D|D d|0~~99999|
970 +
971 +**3)PLC Settings (GX Works2 )**
972 +
973 +Create a project
974 +
975 +Set PLC IP, subnet mask and gateway;
976 +
977 +Select [Binary Code] as communication data code;
978 +
979 +[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_776e17505f3fc6c0.png?width=600&height=524&rev=1.1||alt="12.PLC Protocol_html_776e17505f3fc6c0.png" height="524" width="600"]]
980 +
981 +Set PLC port number, for example 1025
982 +
983 +[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_8d0d1a22d388f70b.png?width=600&height=524&rev=1.1||alt="12.PLC Protocol_html_8d0d1a22d388f70b.png" height="524" width="600"]]
984 +
985 +Save settings;
986 +
987 +Download project into PLC device;
988 +
989 +Restart PLC device;
990 +
991 +**4)Configure the communication protocol**
992 +
993 +[[image:image-20220825142659-1.png]]
994 +
995 +**5)Cable Wiring**
996 +
997 +[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_2297240b57346b2a.png?width=401&height=170&rev=1.1||alt="12.PLC Protocol_html_2297240b57346b2a.png" height="170" width="401"]]
998 +
999 +== **QJ71E71 Ethernet Protocol** ==
1000 +
1001 +Mitsubishi QJ71E71 Ethernet communication module;
1002 +
1003 +**1)V-BOX Settings**
1004 +
1005 +|**Items**|**Settings**|**Note**
1006 +|Protocol|MIT QJ71E71 MELSEC|
1007 +|Connection|Ethernet|
1008 +|Port No.|1025|Must be the same as the PLC setting
1009 +|PLC station No.|0|Must be the same as the PLC setting
1010 +
1011 +**2)Address List**
1012 +
1013 +|**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note**
1014 +|(% rowspan="18" %)Bit|X|X|X h|0~~1FFF|
1015 +|Y|Y|Y h|0~~1FFF|
1016 +|M|M|M d|0~~99999|
1017 +|L|L|L d|0~~8191|
1018 +|F|F|F d|0~~2047|
1019 +|B|B|B h|0~~1FFF|
1020 +|V|V|V d|0~~2047|
1021 +|TS|TS|TS d|0~~2047|
1022 +|TC|TC|TC d|0~~2047|
1023 +|SS|SS|SS d|0~~2047|
1024 +|SC|SC|SC d|0~~2047|
1025 +|CS|CS|CS d|0~~1023|
1026 +|CC|CC|CC d|0~~1023|
1027 +|SB|SB|SB h|0~~7FF|
1028 +|S|S|S d|0~~8191|
1029 +|DX|DX|DX h|0~~1FFF|
1030 +|DY|DY|DY h|0~~1FFF|
1031 +|SM|SM|SM d|8000~~9999|
1032 +|(% rowspan="10" %)Word|SD|SD|SD d|0~~2047|
1033 +|D|D|D d|0~~12287|
1034 +|W|W|W h|0~~1FFF|
1035 +|TN|TN|TN d|0~~2047|
1036 +|SN|SN|SN d|0~~2047|
1037 +|CN|CN|CN d|0~~1023|
1038 +|R|R|R d|0~~32767|
1039 +|SW|SW|SW h|0~~7FF|
1040 +|Z|Z|Z d|0~~15|
1041 +|ZR|ZR|ZR h|0~~FE7FF|
1042 +
1043 +**3)PLC Settings(GX Works2)**
1044 +
1045 +* Click [Ethernet/CC IE/MELSECNET];
1046 +* Please select [Ethernet] as network type;
1047 +* Set station I/O number according to situation (For example, 0000 means that the module is connected to PLC CPU in first order);
1048 +* Select [Online] as Mode;
1049 +* Click [Operation setting] to set IP;
1050 +* Select [Binary Code] as [Communication Data Code];
1051 +* Set protocol: TCP;
1052 +* Set [unpassive] in [Open system];
1053 +* Set [receive] in [Fixed buffer];
1054 +* Set [procedure Exist] in [Fixed buffer communication];
1055 +* Disable [Pairing open];
1056 +* Set [No confirm] in [Existence confirmation];
1057 +* Host station port number: 1025;
1058 +* Save settings;
1059 +* Download project into PLC and restart it
1060 +
1061 +**4)Configure the communication protocol**
1062 +
1063 +[[image:image-20220825143728-1.png]]
1064 +
1065 +**5)Cable Wiring**
1066 +
1067 +[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_2297240b57346b2a.png?width=401&height=170&rev=1.1||alt="12.PLC Protocol_html_2297240b57346b2a.png"]]
1068 +
1069 += Create communication with **Delta PLC** =
1070 +
868 868  == **DVP Ethernet Protocol** ==
869 869  
870 -[[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Delta%20DVP%20Ethernet.zip]]
1073 +[[下载链接>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Delta%20DVP%20Ethernet.zip]]
871 871  
872 -== **DVP Serial Protocol** ==
1075 +== **DVP serial protocol** ==
873 873  
874 -[[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Delta%20DVP%20Ethernet.zip]]
1077 +[[下载链接>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Delta%20DVP%20Ethernet.zip]]
875 875  
876 -= **Omron PLC** =
1079 +== **AS Ethernet Protocol** ==
877 877  
878 -== **CP1 Series Protocol** ==
1081 +**1)V-BOX Settings**
879 879  
880 -[[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communication%20with%20ORMON%20CP1%20Series.zip]]
1083 +|=**Items**|=**Settings**|=**Note**
1084 +|Protocol|DELTA AS300 MODBUS TCP|
1085 +|Connection|Ethernet|
1086 +|Port No.|502|
1087 +|Device No.|1|
1088 +|HMI No.|0|
881 881  
882 -== **CJ2M Series Protocol** ==
1090 +**2)Address List**
883 883  
884 -[[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communication%20with%20ORMON%20CJ2M.zip]]
1092 +|**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note**
1093 +|Bit|X|X|X d|0~~63|
1094 +|Bit|Y|Y|Y d|0~~63|
1095 +|Bit|D|D|D d|0~~29999|
1096 +|Bit|M|M|M d|0~~8191|
1097 +|Bit|SM|SM|SM d|0~~4095|
1098 +|Bit|S|S|S h|0~~2047|
1099 +|Bit|T|T|T d|0~~511|
1100 +|Bit|C|C|C d|0~~511|
1101 +|Bit|HC|HC|HC d|0~~255|
1102 +|Word|X|X|X h|0~~63|
1103 +|Word|Y|Y|Y d|0~~63|
1104 +|Word|SR|SR|SR d|0~~2047|
1105 +|Word|D|D|D d|0~~29999|
1106 +|Word|T|T|T d|0~~511|
1107 +|Word|C|C|C h|0~~511|
1108 +|Word|E|E|E d|0~~9|
885 885  
886 -= **Modbus RTU** =
1110 +**3)Configure the communication protocol**
887 887  
888 -== **V-BOX as master** ==
889 889  
890 -Select the protocol “(% class="mark" %)Modbus RTU Slave(All Fuction)”,
1113 +[[image:image-20220831160010-4.png]]
891 891  
892 -(% class="mark" %)then set BaudRate,Port,Stop Bit,Data Bit,Parity
1115 +**4)Cable Wiring**
893 893  
1117 +Figure
1118 +
1119 +[[image:image-20220831155101-1.png]][[image:image-20220831160055-5.png]]
1120 +
1121 +Pin Definition Diagram
1122 +
1123 +[[image:image-20220831155157-3.png]]
1124 +
1125 += Create communication with **Omron PLC** =
1126 +
1127 +== **CP1 Series Protocol ** ==
1128 +
1129 +[[下载链接>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communication%20with%20ORMON%20CP1%20Series.zip]]
1130 +
1131 +== **CP2M Series Protocol** ==
1132 +
1133 +[[下载链接>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communication%20with%20ORMON%20CJ2M.zip]]
1134 +
1135 +
1136 +== **EC55 Protocol** ==
1137 +
1138 +Supported device: EC55 temperature instrument
1139 +
1140 +**1)V-BOX Settings**
1141 +
1142 +|**Items**|**Settings**|**Note**
1143 +|Protocol|Omron EC55|
1144 +|Connection|RS485 (9600, 2, 7, EVEN)|
1145 +|Port No.|None|
1146 +|PLC station No.|0|
1147 +
1148 +**2)Address List**
1149 +
1150 +|**Type**|**Register**|**Device range**|**HMI range**|**Function**
1151 +|(% rowspan="3" %)Double word|C0|0-13 (Hex)|0-19|Set read only parameter for area 0
1152 +|C1|0-4D(Hex)|0-77|Set Read/Write parameter for area 0
1153 +|C3|0-CD(Hex)|0-205|Set Read/Write parameter for area 1
1154 +|(% rowspan="6" %)Word|80|0-13(Hex)|0-19|Set read only parameter in area 0
1155 +|81|0-4D(Hex)|0-77|Set Read/Write parameter in area 0
1156 +|83|0-CD(Hex)|0-205|Set Read/Write parameter in area 1
1157 +|CP|-|0-6|Read controller intrinsic property
1158 +|CS|-|0-2|Read controller states
1159 +|CA|-|0-17|Action command
1160 +
1161 +**3)Device Settings**
1162 +
1163 +Omron E5CC PLC configuration
1164 +
1165 +After entering the Communication Settings menu, please set the parameters to the default values for the following table. Press the cycle key of the instrument to enter the next setting.
1166 +
1167 +[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_3d95e093792ba98a.png?width=550&height=229&rev=1.1||alt="12.PLC Protocol_html_3d95e093792ba98a.png" height="229" width="550"]]
1168 +
1169 +According to PLC configuration and communication port configuration information of the HMI, provide the corresponding steps and configuration screenshots. This configuration needs to communicate properly with the above PLC configuration. The project settings are as follows
1170 +
1171 +[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_be583aa69dd6cf4c.png?width=550&height=242&rev=1.1||alt="12.PLC Protocol_html_be583aa69dd6cf4c.png" height="242" width="550"]]
1172 +
1173 +**✎Note:** The communication settings for HMI should be consistent with this setting.
1174 +
1175 +**4)Configure the communication protocol**
1176 +
1177 +[[image:image-20220831161041-1.png]]
1178 +
1179 +**5)Cable Wiring**
1180 +
1181 +[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_5e9a81a14106da9e.png?width=392&height=223&rev=1.1||alt="12.PLC Protocol_html_5e9a81a14106da9e.png" height="223" width="392"]]
1182 +
1183 +[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_1897d92be6948d58.png?width=393&height=223&rev=1.1||alt="12.PLC Protocol_html_1897d92be6948d58.png" height="223" width="393"]]
1184 +
1185 +**✎Note:**
1186 +
1187 +* COM3 only available in PI8000/PI9000 series.
1188 +* CA address could not support continuous writing function;
1189 +* Because of CP address intrinsic property: read control intrinsic property, so please place the character input part in use. Set address with CP0 and character length 10, used to display controller type. And place a number input part, set address with CP5 (cache size). Do not place other CP type address without CP0 in screen, otherwise CP type address is invalid
1190 +* When set value into read & write address, it is necessary to switch the temperature instrument meter to the corresponding interface according to the menu of the instrument where the address locates, so that the value could be written, otherwise, the value could not be written; When the communication write setting of the instrument is turned off, the writing function is invalid. Writing function could be opened by using the 00 address of the CA register, which write 01 value.
1191 +* When continuous writing of a value to a read-write address, please make sure all continuous writing address could be written. Otherwise, if one of these addresses could not be written, then all continuous writing commands will fail.
1192 +* Because of the mechanism problem, this protocol could not support CompoWay/F function that is read-write function of variables in protocol document.
1193 +* When using double-word address, set the data format to 32 bits, otherwise the read/write function is unable.
1194 +* Please set the communication delay time of 10ms in setting, to avoid that the instrument may not be able to communicate in a short time due to too fast data access and too much connection requests.
1195 +* [[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_d428cad280fdefb3.png?width=347&height=276&rev=1.1||alt="12.PLC Protocol_html_d428cad280fdefb3.png" height="276" width="347"]]Because of the particularity of the instrument, it is necessary to write the value of the address in the menu interface corresponding to the address, and to enter the menu where the address locates, so that the value could be written.
1196 +
1197 += Create communication with **Modbus RTU** =
1198 +
1199 +== **V-BOX as Slave** ==
1200 +
1201 +Select the protocol "Modbus RTU Slave (All Fuction)",
1202 +
1203 +Then set baud rate, port, stop bits, data bits, parity.
1204 +
894 894  (% style="text-align:center" %)
895 895  [[image:1624342015914-382.png||height="486" width="800" class="img-thumbnail"]]
896 896  
897 -== **V-BOX as slave** ==
1208 +== **V-BOX as Master** ==
898 898  
899 -Select the protocol “(% class="mark" %)**Modbus RTU Master”**,
1210 +Select the protocol "Modbus RTU Master",
900 900  
901 -(% class="mark" %)then set BaudRate,Port,Stop Bit,Data Bit,Parity
1212 +Then set baud rate, port, stop bits, data bits, parity
902 902  
903 903  (% style="text-align:center" %)
904 904  [[image:1624348709622-711.png||queryString="width=809&height=493" height="488" width="800" class="img-thumbnail"]]
905 905  
906 -**Address List**
1217 +**address list**
907 907  
908 908  (% class="table-bordered" %)
909 -|**Type**|**Register**|**Function code & Description**
910 -|(% rowspan="11" %)Word|(% rowspan="3" %)3|04 (read input register: read current binary value in one or more input registers)
1220 +|**type**|**register**|**Function code and description**
1221 +|(% rowspan="11" %)|(% rowspan="3" %)3|04 (Read Input Registers: Read the current binary value in one or more input registers)
911 911  |06 (write single register: write a binary value to a holding register)
912 912  |10 (write values to multiple addresses )
913 913  |(% rowspan="3" %)4|03 (read holding register: read current binary value in one or more holding registers)
image-20220825104904-1.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +123.5 KB
Content
image-20220825105105-2.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +78.5 KB
Content
image-20220825105533-3.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +23.8 KB
Content
image-20220825112403-1.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +128.1 KB
Content
image-20220825142437-1.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +126.5 KB
Content
image-20220825142659-1.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +124.2 KB
Content
image-20220825143728-1.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +124.7 KB
Content
image-20220825160227-1.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +148.8 KB
Content
image-20220825160341-2.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +121.7 KB
Content
image-20220825160648-3.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +122.7 KB
Content
image-20220825160820-4.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +24.9 KB
Content
image-20220825160925-5.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +31.0 KB
Content
image-20220825160929-6.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +31.0 KB
Content
image-20220825161440-7.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +90.7 KB
Content
image-20220825161612-8.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +86.3 KB
Content
image-20220831155101-1.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +34.6 KB
Content
image-20220831155129-2.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +44.9 KB
Content
image-20220831155157-3.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +20.8 KB
Content
image-20220831160010-4.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@