Changes for page 1 Communication

Last modified by Hunter on 2024/07/01 10:54

From version 11.1
edited by Ben
on 2022/07/14 12:00
Change comment: There is no comment for this version
To version 15.1
edited by Ben
on 2022/07/14 14:50
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -61,38 +61,38 @@
61 61  (% class="wikigeneratedid" %)
62 62  == ==
63 63  
64 -(% class="wikigeneratedid" %)
65 -== **Communication with Allen-Bradley CompactLogix L1769** ==
64 +== **2 Communication with Allen-Bradley CompactLogix L1769** ==
66 66  
67 -=== **Overview** ===
68 -
69 69  (((
70 70  This example introduces the establishment of Ethernet communication between Wecon V-box and Allen-Bradley L1769. It is introduced through three parts: PLC software configuration, V-box software configuration, and hardware wiring.
68 +
69 +
71 71  )))
72 72  
73 73  (((
74 -
73 +(% class="wikigeneratedid" id="HSoftwareconfigurationofPLC" %)
74 +(((
75 +**Software configuration of PLC**
75 75  )))
76 76  
78 +(% class="wikigeneratedid" id="HPLCprogrammingsoftware" %)
77 77  (((
78 -== **1 Software configuration of PLC** ==
80 +**1)PLC programming software**
81 +)))
79 79  
80 -=== **1.1 PLC programming software** ===
83 +[[image:image-20220714113935-3.png||height="324" width="270"]]
81 81  
82 - [[image:image-20220714113935-3.png]]
83 -
84 -=== **1.2 New PLC project** ===
85 -
85 +(% class="wikigeneratedid" id="HNewPLCproject" %)
86 86  (((
87 -Click New Project and select the PLC model.
87 +**2)New PLC project**
88 88  )))
89 89  
90 90  (((
91 - [[image:image-20220714114247-4.png]]
91 +Click New Project and select the PLC model.
92 92  )))
93 93  
94 94  (((
95 - [[image:image-20220714114257-5.png]]
95 +[[image:image-20220714114247-4.png||height="298" width="552"]] [[image:image-20220714114257-5.png||height="445" width="551"]]
96 96  )))
97 97  
98 98  (((
... ... @@ -100,26 +100,37 @@
100 100  )))
101 101  
102 102  (((
103 -=== **1.3 Set Ethernet parameters** ===
103 +(% class="wikigeneratedid" id="HSetEthernetparameters" %)
104 +(((
105 +**3)Set Ethernet parameters**
106 +)))
104 104  
105 105  (((
109 +(((
106 106  Follow the steps below to configure Ethernet parameters
107 107  )))
112 +)))
108 108  
109 109  (((
115 +(((
110 110  PLC IP address:192.168.40.101
111 111  )))
118 +)))
112 112  
113 113  (((
121 +(((
114 114  default gateway:192.168.40.1
115 115  )))
124 +)))
116 116  
117 117  (((
127 +(((
118 118  subnet mask:255.255.255.0
119 119  )))
130 +)))
120 120  
121 121  (((
122 - [[image:image-20220714115012-6.png]]
133 +[[image:image-20220714115012-6.png]]
123 123  )))
124 124  
125 125  (((
... ... @@ -127,36 +127,48 @@
127 127  )))
128 128  
129 129  (((
130 -== **2.V-box software configuration** ==
141 +(% class="wikigeneratedid" id="HV-boxsoftwareconfiguration" %)
142 +(((
143 +**V-box software configuration**
144 +)))
131 131  
132 -=== **2.1. V-box programming software** ===
146 +(% class="wikigeneratedid" id="HV-boxprogrammingsoftware" %)
147 +(((
148 +**1)V-box programming software**
149 +)))
133 133  
134 - [[image:image-20220714115214-7.png]]
151 +(% class="wikigeneratedid" %)
152 +(((
153 + [[image:image-20220714115214-7.png||height="276" width="456"]]
154 +)))
135 135  
156 +(% class="wikigeneratedid" id="HConfiguredevicenetwork" %)
157 +(((
158 +**2)Configure device network**
159 +)))
136 136  
137 -=== **2.2. Configure device network** ===
138 -
139 139  (((
162 +(((
140 140  Click the Configuration Download button[[image:image-20220714115308-8.png||height="22" width="15"]], It is used to configure the device network, update the device time, obtain the device machine code, check the device network, etc.
141 141  )))
165 +)))
142 142  
143 143  (((
144 -In the example below, the IP address of V-Box is configured as 192.168.40.66, and the networking method is 4G connection.
168 +(((
169 +In the example below, the IP address of V-Box is configured as 192.168.40.66, and the networking method is 4G connection [[image:image-20220714115440-9.png||height="425" width="791"]]
145 145  )))
146 -
147 - [[image:image-20220714115440-9.png||height="425" width="791"]]
148 148  )))
149 149  )))
150 -
151 -== **2.3. V-net add device** ==
152 152  )))
153 153  
175 +(% class="wikigeneratedid" id="HV-netadddevice" %)
154 154  (((
155 -Open VNET client software → add device. As shown in the figure below, click "+" in the order of steps, and the Add Device window will pop up, enter the device machine code/product code, device password, and device alias to add the device. 
177 +**3)V-net add device**
156 156  )))
179 +)))
157 157  
158 158  (((
159 - [[image:image-20220714115640-10.png||height="430" width="797"]]
182 +Open VNET client software → add device. As shown in the figure below, click "+" in the order of steps, and the Add Device window will pop up, enter the device machine code/product code, device password, and device alias to add the device.   [[image:image-20220714115640-10.png||height="430" width="797"]]
160 160  )))
161 161  
162 162  (((
... ... @@ -164,18 +164,26 @@
164 164  )))
165 165  
166 166  (((
167 -=== **2.4. Set communication port parameters** ===
190 +(% class="wikigeneratedid" id="HSetcommunicationportparameters" %)
191 +(((
192 +**4)Set communication port parameters**
193 +)))
168 168  
169 -In the device list on the left, find the Vbox that communicates with the L1769, click it and select configuration,communication port configuration in the main interface to add a communication protocol.
170 -
171 - [[image:image-20220714115848-11.png||height="432" width="802"]]
195 +In the device list on the left, find the Vbox that communicates with the L1769, click it and select configuration,communication port configuration in the main interface to add a communication protocol. [[image:image-20220714115848-11.png||height="432" width="802"]]
172 172  )))
173 173  
174 -
175 175  The communication port is selected as Ethernet, the device type is selected as Allen-Bradley, the protocol is Allen-BradleyMicro850_FreeTag EthemetIP, and the IP is the internal IP address of the L1769 PLC. The port number is 44818.
176 176  
200 +[[image:image-20220714143820-1.png]]
177 177  
202 +After adding the protocol Allen-BradleyMicro850_FreeTag, click[[image:image-20220714143838-2.png]]icon add label.
178 178  
204 +[[image:image-20220714143849-3.png]]
205 +
206 +
207 +== Engineering production ==
208 +
209 +
179 179  == **Siemens S7-1200** ==
180 180  
181 181  [[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communicate%20with%20S7-1200%20via%20Ehernet.zip]]
image-20220714143820-1.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +1.4 MB
Content
image-20220714143838-2.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +520 bytes
Content
image-20220714143849-3.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +1.3 MB
Content