Changes for page 1 Communication
Last modified by Hunter on 2024/07/01 10:54
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 3 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -61,38 +61,38 @@ 61 61 (% class="wikigeneratedid" %) 62 62 == == 63 63 64 -(% class="wikigeneratedid" %) 65 -== **Communication with Allen-Bradley CompactLogix L1769** == 64 +== **2 Communication with Allen-Bradley CompactLogix L1769** == 66 66 67 -=== **Overview** === 68 - 69 69 ((( 70 70 This example introduces the establishment of Ethernet communication between Wecon V-box and Allen-Bradley L1769. It is introduced through three parts: PLC software configuration, V-box software configuration, and hardware wiring. 68 + 69 + 71 71 ))) 72 72 73 73 ((( 74 - 73 +(% class="wikigeneratedid" id="HSoftwareconfigurationofPLC" %) 74 +((( 75 +**Software configuration of PLC** 75 75 ))) 76 76 78 +(% class="wikigeneratedid" id="HPLCprogrammingsoftware" %) 77 77 ((( 78 -== **1 Software configuration of PLC** == 80 +**1)PLC programming software** 81 +))) 79 79 80 - === **1.1PLCprogrammingsoftware**===83 +[[image:image-20220714113935-3.png||height="324" width="270"]] 81 81 82 - [[image:image-20220714113935-3.png]] 83 - 84 -=== **1.2 New PLC project** === 85 - 85 +(% class="wikigeneratedid" id="HNewPLCproject" %) 86 86 ((( 87 - ClickNew Projectand select the PLC model.87 +**2)New PLC project** 88 88 ))) 89 89 90 90 ((( 91 - [[image:image-20220714114247-4.png]]91 +Click New Project and select the PLC model. 92 92 ))) 93 93 94 94 ((( 95 - 95 +[[image:image-20220714114247-4.png||height="298" width="552"]] [[image:image-20220714114257-5.png||height="445" width="551"]] 96 96 ))) 97 97 98 98 ((( ... ... @@ -100,26 +100,37 @@ 100 100 ))) 101 101 102 102 ((( 103 -=== **1.3 Set Ethernet parameters** === 103 +(% class="wikigeneratedid" id="HSetEthernetparameters" %) 104 +((( 105 +**3)Set Ethernet parameters** 106 +))) 104 104 105 105 ((( 109 +((( 106 106 Follow the steps below to configure Ethernet parameters 107 107 ))) 112 +))) 108 108 109 109 ((( 115 +((( 110 110 PLC IP address:192.168.40.101 111 111 ))) 118 +))) 112 112 113 113 ((( 121 +((( 114 114 default gateway:192.168.40.1 115 115 ))) 124 +))) 116 116 117 117 ((( 127 +((( 118 118 subnet mask:255.255.255.0 119 119 ))) 130 +))) 120 120 121 121 ((( 122 - 133 +[[image:image-20220714115012-6.png]] 123 123 ))) 124 124 125 125 ((( ... ... @@ -127,36 +127,48 @@ 127 127 ))) 128 128 129 129 ((( 130 -== **2.V-box software configuration** == 141 +(% class="wikigeneratedid" id="HV-boxsoftwareconfiguration" %) 142 +((( 143 +**V-box software configuration** 144 +))) 131 131 132 -=== **2.1. V-box programming software** === 146 +(% class="wikigeneratedid" id="HV-boxprogrammingsoftware" %) 147 +((( 148 +**1)V-box programming software** 149 +))) 133 133 134 - [[image:image-20220714115214-7.png]] 151 +(% class="wikigeneratedid" %) 152 +((( 153 + [[image:image-20220714115214-7.png||height="276" width="456"]] 154 +))) 135 135 156 +(% class="wikigeneratedid" id="HConfiguredevicenetwork" %) 157 +((( 158 +**2)Configure device network** 159 +))) 136 136 137 -=== **2.2. Configure device network** === 138 - 139 139 ((( 162 +((( 140 140 Click the Configuration Download button[[image:image-20220714115308-8.png||height="22" width="15"]], It is used to configure the device network, update the device time, obtain the device machine code, check the device network, etc. 141 141 ))) 165 +))) 142 142 143 143 ((( 144 -In the example below, the IP address of V-Box is configured as 192.168.40.66, and the networking method is 4G connection. 168 +((( 169 +In the example below, the IP address of V-Box is configured as 192.168.40.66, and the networking method is 4G connection [[image:image-20220714115440-9.png||height="425" width="791"]] 145 145 ))) 146 - 147 - [[image:image-20220714115440-9.png||height="425" width="791"]] 148 148 ))) 149 149 ))) 150 - 151 -== **2.3. V-net add device** == 152 152 ))) 153 153 175 +(% class="wikigeneratedid" id="HV-netadddevice" %) 154 154 ((( 155 - OpenVNET client software→ add device. As shown inthe figure below, click "+" in the order of steps,andthe AddDevicewindow will pop up, enter the device machine code/product code, device password, and device alias to add the device.177 +**3)V-net add device** 156 156 ))) 179 +))) 157 157 158 158 ((( 159 - 182 +Open VNET client software → add device. As shown in the figure below, click "+" in the order of steps, and the Add Device window will pop up, enter the device machine code/product code, device password, and device alias to add the device. [[image:image-20220714115640-10.png||height="430" width="797"]] 160 160 ))) 161 161 162 162 ((( ... ... @@ -164,18 +164,26 @@ 164 164 ))) 165 165 166 166 ((( 167 -=== **2.4. Set communication port parameters** === 190 +(% class="wikigeneratedid" id="HSetcommunicationportparameters" %) 191 +((( 192 +**4)Set communication port parameters** 193 +))) 168 168 169 -In the device list on the left, find the Vbox that communicates with the L1769, click it and select configuration,communication port configuration in the main interface to add a communication protocol. 170 - 171 - [[image:image-20220714115848-11.png||height="432" width="802"]] 195 +In the device list on the left, find the Vbox that communicates with the L1769, click it and select configuration,communication port configuration in the main interface to add a communication protocol. [[image:image-20220714115848-11.png||height="432" width="802"]] 172 172 ))) 173 173 174 - 175 175 The communication port is selected as Ethernet, the device type is selected as Allen-Bradley, the protocol is Allen-BradleyMicro850_FreeTag EthemetIP, and the IP is the internal IP address of the L1769 PLC. The port number is 44818. 176 176 200 +[[image:image-20220714143820-1.png]] 177 177 202 +After adding the protocol Allen-BradleyMicro850_FreeTag, click[[image:image-20220714143838-2.png]]icon add label. 178 178 204 +[[image:image-20220714143849-3.png]] 205 + 206 + 207 +== Engineering production == 208 + 209 + 179 179 == **Siemens S7-1200** == 180 180 181 181 [[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communicate%20with%20S7-1200%20via%20Ehernet.zip]]
- image-20220714143820-1.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +1.4 MB - Content
- image-20220714143838-2.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +520 bytes - Content
- image-20220714143849-3.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +1.3 MB - Content