Changes for page 1 Communication
Last modified by Hunter on 2024/07/01 10:54
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 31 added, 0 removed)
- image-20220714143820-1.png
- image-20220714143838-2.png
- image-20220714143849-3.png
- image-20220714160006-1.png
- image-20220714160034-2.png
- image-20220714160120-3.png
- image-20220714160335-4.png
- image-20220714160412-5.png
- image-20220714160439-6.png
- image-20220714160541-7.png
- image-20220714160651-8.png
- image-20220714160843-9.png
- image-20220714160943-10.png
- image-20220714161014-11.png
- image-20220714161120-12.png
- image-20220714161229-13.png
- image-20220714161445-14.png
- image-20220714162600-1.png
- image-20220714162617-2.png
- image-20220714162629-3.png
- image-20220714162652-4.png
- image-20220714162713-5.png
- image-20220714162725-6.png
- image-20220714162737-7.png
- image-20220714162752-8.png
- image-20220714162805-9.png
- image-20220714162814-10.png
- image-20220714162827-11.png
- image-20220714162841-12.png
- image-20220714162856-13.png
- image-20220820164423-1.png
Details
- Page properties
-
- Content
-
... ... @@ -1,7 +1,5 @@ 1 -= ** 1 General communicationwith PLC** =1 += **Modbus RTU** = 2 2 3 -== **Modbus RTU** == 4 - 5 5 === **V-BOX as master** === 6 6 7 7 Select the protocol “(% class="mark" %)Modbus RTU Slave(All Fuction)”, ... ... @@ -47,79 +47,298 @@ 47 47 |(% rowspan="2" %)W15|01 (Read coil state to obtain the current state of a set of logic coils) 48 48 |0F (Write multiple bits) 49 49 50 -= =**WECONLX3VPLC** ==48 += **WECON PLC** = 51 51 52 -S elect theprotocol(% class="mark"%)"WECON LX3V"50 +Supported series: WECON LX2V/ LX2E/ LX3V/LX3VP/LX3VE/LX3VM 53 53 54 - (%class="mark" %)then setBaudRate,Port,Stop Bit,Data Bit,Paritysame with PLC.52 +**HMI Settings** 55 55 56 -(% class="mark" %)WECON PLC RS422 port,default communication parameters is 9600,1,7,ZEVEN 54 +|**Item**|**Settings**|**Note** 55 +|Protocol|WECON LX2V/ LX2E/ LX3V/LX3VP/LX3VE/LX3VM| 56 +|Connection|RS422/RS485| 57 +|Baud rate|9600| 58 +|Data bit|7| 59 +|Parity|EVEN| 60 +|Stop bit|1| 61 +|PLC station No.|1| 57 57 63 +**Address List** 64 + 65 +|**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note** 66 +|(% rowspan="6" %)Bit|X|X|Xo|0~~303237| 67 +|Y|Y|Y o|0~~303237| 68 +|M|M|M d|0~~99999| 69 +|T|T|T d|0~~99999| 70 +|C|C|C d|0~~99999| 71 +|S|S|S d|0~~99999| 72 +|(% rowspan="8" %)Word|X|X|Xo|0~~303237| 73 +|Y|Y|Y o|0~~303237| 74 +|M|M|M d|0~~99999| 75 +|T|T|T d|0~~99999| 76 +|C|C|C d|0~~199| 77 +|D|D|D d|0~~7999| 78 +|S|S|S d|0~~99999| 79 +|SD|SD|SD d|8000~~9999| 80 + 81 +**Cable Wiring** 82 + 83 +* **RS485** 84 + 58 58 (% style="text-align:center" %) 59 -[[image:1 624348978863-771.png||queryString="width=812&height=494" height="487" width="800" class="img-thumbnail"]]86 +[[image:12.PLC Protocol_html_1897d92be6948d58.png||data-xwiki-image-style-alignment="center" height="223" width="393" class="img-thumbnail"]] 60 60 61 -(% class="wikigeneratedid" %) 62 -== == 88 +* **RS422** 63 63 64 -(% class="wikigeneratedid" %)65 - == **Communicationh Allen-Bradley CompactLogixL1769**==90 +(% style="text-align:center" %) 91 +[[image:12.PLC Protocol_html_5c7fca9a70da2ee8.png||data-xwiki-image-style-alignment="center" height="247" width="389" class="img-thumbnail"]] 66 66 67 - ===**Overview**===93 +**✎Note:** 68 68 95 +* HMI COM3 is available in PI8000 series and COM3 is in COM2(hardware PIN 7 and PIN 8) . 96 +* If PLC <= 20 points,such as LX3V-1208/LX3V-0806 PLC,PLC RS485A and RS485B mean PLC COM2 RS485+ and RS485- .PLC COM2 can support modbus. Please refer to PLC COM2 setting manual. 97 + 98 +[[https:~~/~~/drive.google.com/drive/folders/13rgso7oUlatZQN_SNEcJCcN4toEdDPoP?usp=sharing>>url:https://drive.google.com/drive/folders/13rgso7oUlatZQN_SNEcJCcN4toEdDPoP?usp=sharing]] 99 + 100 + 101 +== **V-BOX and Wecon LX5V serial communication** == 102 + 103 +This example introduces the establishment of serial port communication between Wecon HMI and LX5V. It is introduced through three parts: PLC software configuration, HMI software configuration, and hardware wiring. 104 + 105 +**Software configuration of PLC** 106 + 107 +**1)PLC programming software** 108 + 109 +[[image:image-20220810164710-1.png]] 110 + 111 + 112 +**2)New PLC project** 113 + 114 +Click New Project and select the PLC model. 115 + 116 +[[image:image-20220810172412-1.png]] 117 + 118 + 119 +**3)Set Serial port parameters** 120 + 121 +Follow the steps below to configure Serial port parameters 122 + 123 +Baud rate:115200 124 + 125 +Data bit:8 126 + 127 +Stop bit:1 128 + 129 +Parity:No verification 130 + 131 +[[image:image-20220810165759-3.png]] 132 + 133 + 134 +**4)Registers list** 135 + 136 +[[image:image-20220811102219-3.png]] 137 + 138 + 139 +**HMI software configuration** 140 + 141 +**1)HMI programming software** 142 + 143 + [[image:image-20220810171237-4.png]] 144 + 145 +**2)New HMI project** 146 + 147 +Click New Project and select the HMI model. 148 + 149 +[[image:image-20220810172010-5.png]] 150 + 151 + 152 +**3)Set communication port parameters** 153 + 154 +Click the communication configuration button on the left to find the communication protocol with LX5V. After selecting the protocol, configure the communication parameters of the COM port. 155 + 156 +Baud rate:115200 157 + 158 +Data bit:8 159 + 160 +Stop bit:1 161 + 162 +Parity:No verification 163 + 164 +[[image:image-20220811104012-1.png]] 165 + 166 + 167 +**hardware connection** 168 + 169 +**1)Hardware wiring diagram** 170 + 171 +This example introduces WeconHMI with LX5V PLC to establish communication through serial port. The connection diagram is as follows: 172 + 173 + 174 + 175 +[[image:image-20220811103005-4.png]] 176 + 177 +[[image:image-20220811103227-7.png]] 178 + 179 +The above are all the steps for establishing serial port communication between Wecon HMI with LX5V PLC. 180 + 181 +== **HMI and Wecon LX5V-N Ethernet communication** == 182 + 183 + This example introduces the establishment of Ethernet communication between Wecon HMI and LX5V. It is introduced through three parts: PLC software configuration, HMI software configuration, and hardware wiring. 184 + 185 +**Software configuration of PLC** 186 + 187 +**1)PLC programming software** 188 + 189 +[[image:image-20220810164710-1.png]] 190 + 191 +**2)New PLC project** 192 + 193 +Click New Project and select the PLC model. 194 + 195 +[[image:image-20220811115454-1.png]] 196 + 197 +**3)Set Ethernet port parameters** 198 + 199 +Follow the steps below to configure Ethernet parameters 200 + 201 +PLC IP address:192.168.39.200 202 + 203 +default gateway:192.168.39.1 204 + 205 +subnet mask:255.255.255.0 206 + 207 +[[image:image-20220811140530-2.png]] 208 + 209 +**4)Registers list** 210 + 211 +[[image:image-20220811102219-3.png]] 212 + 213 +**HMI software configuration** 214 + 215 +**1)HMI programming software** 216 + 217 + [[image:image-20220810171237-4.png]] 218 + 219 +**2)New HMI project** 220 + 221 +Click New Project and select the HMI model. 222 + 223 +[[image:image-20220810172010-5.png]] 224 + 225 +**3)Set communication port parameters** 226 + 227 +Click the project setting button on the left to configure the IP address of the HMI machine to ensure that the HMI and PLC IP remain in a local area network. 228 + 229 +HMI IP address:192.168.39.201 230 + 231 +default gateway:192.168.39.1 232 + 233 +subnet mask:255.255.255.0 234 + 235 +[[image:image-20220811170753-2.png]] 236 + 237 +Next, click Communication Settings to configure the IP of the HMI communication object. 238 + 239 +[[image:image-20220811163047-1.png]] 240 + 241 +**hardware connection** 242 + 243 +**1)Hardware wiring diagram** 244 + 245 +This example introduces WeconHMI with LX5V-N PLC to establish communication through ethernet. The connection diagram is as follows: 246 + 247 +[[image:image-20220811170248-1.png]] 248 + 249 +The above are all the steps for establishing ethernet communication between Wecon HMI with LX5V PLC. 250 + 251 +(% style="text-align:center" %) 252 +[[image:1624348978863-771.png||queryString="width=812&height=494" height="487" width="800" class="img-thumbnail"]] 253 + 254 += **Rockwell PLC** = 255 + 256 +== **Communication with AB CompactLogix L1769** == 257 + 69 69 ((( 259 +((( 70 70 This example introduces the establishment of Ethernet communication between Wecon V-box and Allen-Bradley L1769. It is introduced through three parts: PLC software configuration, V-box software configuration, and hardware wiring. 71 71 ))) 72 72 73 -((( 74 74 75 75 ))) 76 76 77 77 ((( 78 -== **1 Software configuration of PLC** == 267 +(% class="wikigeneratedid" id="HSoftwareconfigurationofPLC" %) 268 +((( 269 +**Software configuration of PLC** 270 +))) 79 79 80 -=== **1.1 PLC programming software** === 272 +(% class="wikigeneratedid" id="HPLCprogrammingsoftware" %) 273 +((( 274 +**1)PLC programming software** 275 +))) 81 81 82 - 13935-3.png]]277 +[[image:image-20220714162600-1.png]] 83 83 84 -=== **1.2 New PLC project** === 85 - 279 +(% class="wikigeneratedid" id="HNewPLCproject" %) 86 86 ((( 87 - ClickNew Projectand select the PLC model.281 +**2)New PLC project** 88 88 ))) 89 89 90 90 ((( 91 - [[image:image-20220714114247-4.png]] 285 +((( 286 +Click New Project and select the PLC model. 92 92 ))) 288 +))) 93 93 94 94 ((( 95 - 14257-5.png]]291 +[[image:image-20220714162617-2.png]] 96 96 ))) 97 97 98 98 ((( 99 99 296 + 297 +[[image:image-20220714162652-4.png]] 100 100 ))) 101 101 102 102 ((( 103 -=== **1.3 Set Ethernet parameters** === 301 +(% class="wikigeneratedid" id="HSetEthernetparameters" %) 302 +((( 303 +**3)Set Ethernet parameters** 304 +))) 104 104 105 105 ((( 307 +((( 308 +((( 106 106 Follow the steps below to configure Ethernet parameters 107 107 ))) 311 +))) 312 +))) 108 108 109 109 ((( 315 +((( 316 +((( 110 110 PLC IP address:192.168.40.101 111 111 ))) 319 +))) 320 +))) 112 112 113 113 ((( 323 +((( 324 +((( 114 114 default gateway:192.168.40.1 115 115 ))) 327 +))) 328 +))) 116 116 117 117 ((( 331 +((( 332 +((( 118 118 subnet mask:255.255.255.0 119 119 ))) 335 +))) 336 +))) 120 120 121 121 ((( 122 - 15012-6.png]]339 +[[image:image-20220714162713-5.png]] 123 123 ))) 124 124 125 125 ((( ... ... @@ -127,67 +127,139 @@ 127 127 ))) 128 128 129 129 ((( 130 -== **2.V-box software configuration** == 347 +(% class="wikigeneratedid" id="HV-boxsoftwareconfiguration" %) 348 +((( 349 +**V-box software configuration** 350 +))) 131 131 132 -=== **2.1. V-box programming software** === 352 +(% class="wikigeneratedid" id="HV-boxprogrammingsoftware" %) 353 +((( 354 +**1)V-box programming software** 355 +))) 133 133 134 - [[image:image-20220714115214-7.png]] 357 +(% class="wikigeneratedid" %) 358 +((( 359 + [[image:image-20220714162725-6.png]] 360 +))) 135 135 362 +(% class="wikigeneratedid" id="HConfiguredevicenetwork" %) 363 +((( 364 +**2)Configure device network** 365 +))) 136 136 137 -=== **2.2. Configure device network** === 138 - 139 139 ((( 368 +((( 369 +((( 140 140 Click the Configuration Download button[[image:image-20220714115308-8.png||height="22" width="15"]], It is used to configure the device network, update the device time, obtain the device machine code, check the device network, etc. 141 141 ))) 142 142 143 143 ((( 144 -In the example below, the IP address of V-Box is configured as 192.168.40.66, and the networking method is 4G connection .374 +In the example below, the IP address of V-Box is configured as 192.168.40.66, and the networking method is 4G connection 145 145 ))) 146 - 147 - [[image:image-20220714115440-9.png||height="425" width="791"]] 148 148 ))) 149 149 ))) 150 150 151 -== **2.3. V-net add device** == 379 +((( 380 +((( 381 +[[image:image-20220714162737-7.png]] 382 + 383 + 152 152 ))) 385 +))) 386 +))) 387 +))) 153 153 389 +(% class="wikigeneratedid" id="HV-netadddevice" %) 154 154 ((( 155 - OpenVNET client software→ add device. As shown inthe figure below, click "+" in the order of steps,andthe AddDevicewindow will pop up, enter the device machine code/product code, device password, and device alias to add the device.391 +**3)V-net add device** 156 156 ))) 393 +))) 157 157 158 158 ((( 159 - [[image:image-20220714115640-10.png||height="430" width="797"]] 396 +((( 397 +Open VNET client software → add device. As shown in the figure below, click "+" in the order of steps, and the Add Device window will pop up, enter the device machine code/product code, device password, and device alias to add the device. [[image:image-20220714162752-8.png]] 160 160 ))) 161 161 162 -((( 163 163 164 164 ))) 165 165 166 166 ((( 167 -=== **2.4. Set communication port parameters** === 404 +(% class="wikigeneratedid" id="HSetcommunicationportparameters" %) 405 +((( 406 +**4)Set communication port parameters** 407 +))) 168 168 409 +((( 169 169 In the device list on the left, find the Vbox that communicates with the L1769, click it and select configuration,communication port configuration in the main interface to add a communication protocol. 411 +))) 170 170 171 - 15848-11.png||height="432" width="802"]]413 +[[image:image-20220714162805-9.png]] 172 172 ))) 173 173 174 - 416 +((( 175 175 The communication port is selected as Ethernet, the device type is selected as Allen-Bradley, the protocol is Allen-BradleyMicro850_FreeTag EthemetIP, and the IP is the internal IP address of the L1769 PLC. The port number is 44818. 418 +))) 176 176 420 +[[image:image-20220714162814-10.png]] 177 177 178 178 179 -== **Siemens S7-1200** == 423 +((( 424 +After adding the protocol Allen-BradleyMicro850_FreeTag, click[[image:image-20220714143838-2.png]]icon add label.[[image:image-20220714162827-11.png]] 425 +))) 180 180 181 -[[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communicate%20with%20S7-1200%20via%20Ehernet.zip]] 427 +(% class="wikigeneratedid" id="HEngineeringproduction" %) 428 +((( 429 +**5)Engineering production** 430 +))) 182 182 432 +(% class="wikigeneratedid" %) 433 +((( 434 +((( 435 +According to your own needs, use the V-NET client software to edit the required data monitoring points. 436 +))) 437 + 438 +[[image:image-20220714162841-12.png]] 439 + 440 + 441 +((( 442 +**hardware connection** 443 +))) 444 +))) 445 + 446 +((( 447 +**1)Hardware wiring diagram** 448 +))) 449 + 450 +((( 451 +((( 452 +This example introduces Wecon V-box with Allen-Bradley L1769 PLC to establish communication through Ethernet. The connection diagram is as follows: 453 +))) 454 + 455 +[[image:image-20220714162856-13.png]] 456 + 457 +((( 458 +The above are all the steps for establishing Ethernet communication between Wecon V-box with Allen-Bradley L1769 PLC. 459 + 460 + 183 183 == **Allen-Bradley Ethernet DF1** == 184 184 185 185 [[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Allen-Bradley%20Ethernet%20DF1.zip]] 186 186 465 + 466 += **Siemens PLC** = 467 +))) 468 +))) 469 + 470 +== **Siemens S7-1200** == 471 + 472 +[[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communicate%20with%20S7-1200%20via%20Ehernet.zip]] 473 + 187 187 == **Communication with S7-200 Smart** == 188 188 189 189 [[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communication%20with%20S7-200%20Smart.zip]] 190 190 478 += **Delta PLC** = 479 + 191 191 == **Delta DVP Ethernet** == 192 192 193 193 [[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Delta%20DVP%20Ethernet.zip]] ... ... @@ -214,7 +214,7 @@ 214 214 215 215 = **2 User define protocol** = 216 216 217 -More serial port script instruction,please refer manual:[[Lua script function>>doc:V-BOX.V-Net. 1\.UserManual.04 Lua Script.01 Lua Functions.WebHome]]~-~-->[[3.Serial port operation>>url:http://docs.we-con.com.cn/wiki/vbox/view/HMI/04.Lua%20script%20%20function%20and%20operation/01.Lua%20script%20function/#H3.Serialportoperation]]506 +More serial port script instruction,please refer manual:[[Lua script function>>doc:V-BOX.V-Net.Manual.04 Lua Script.01 Lua Functions.WebHome]]~-~-->[[3.Serial port operation>>url:http://docs.we-con.com.cn/wiki/vbox/view/HMI/04.Lua%20script%20%20function%20and%20operation/01.Lua%20script%20function/#H3.Serialportoperation]] 218 218 219 219 == **Read the temperature sensor.** == 220 220
- image-20220714143820-1.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +1.4 MB - Content
- image-20220714143838-2.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +520 bytes - Content
- image-20220714143849-3.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +1.3 MB - Content
- image-20220714160006-1.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +1.3 MB - Content
- image-20220714160034-2.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +135.2 KB - Content
- image-20220714160120-3.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +58.8 KB - Content
- image-20220714160335-4.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +264.1 KB - Content
- image-20220714160412-5.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +58.5 KB - Content
- image-20220714160439-6.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +104.0 KB - Content
- image-20220714160541-7.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +13.7 KB - Content
- image-20220714160651-8.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +135.2 KB - Content
- image-20220714160843-9.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +165.9 KB - Content
- image-20220714160943-10.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +50.2 KB - Content
- image-20220714161014-11.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +94.3 KB - Content
- image-20220714161120-12.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +94.3 KB - Content
- image-20220714161229-13.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +62.5 KB - Content
- image-20220714161445-14.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +131.2 KB - Content
- image-20220714162600-1.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +58.8 KB - Content
- image-20220714162617-2.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +1.3 MB - Content
- image-20220714162629-3.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +58.5 KB - Content
- image-20220714162652-4.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +58.5 KB - Content
- image-20220714162713-5.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +104.0 KB - Content
- image-20220714162725-6.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +13.7 KB - Content
- image-20220714162737-7.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +135.2 KB - Content
- image-20220714162752-8.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +135.2 KB - Content
- image-20220714162805-9.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +165.9 KB - Content
- image-20220714162814-10.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +50.2 KB - Content
- image-20220714162827-11.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +94.3 KB - Content
- image-20220714162841-12.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +62.5 KB - Content
- image-20220714162856-13.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +131.6 KB - Content
- image-20220820164423-1.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +18.4 KB - Content