... ... @@ -1,10 +1,10 @@
1 -= (% style="color:inherit; font-family:inherit" %)**WECON PLC**(%%) =
1 += Create communication with WECON PLC =
2 2  
3 -== **LX3V Serial Protocol** ==
3 +== **LX3V Serial Protocol** ==
4 4  
5 -Supported series: WECON LX2V/ LX2E/ LX3V/LX3VP/LX3VE/LX3VM
5 +Supported series: Wecon LX2V/ LX2E/ LX3V/LX3VP/LX3VE/LX3VM
6 6  
7 -**1)PLC Settings**
7 +**1)V-BOX setting**
8 8  
9 9  |**Item**|**Settings**|**Note**
10 10  |Protocol|WECON LX2V/ LX2E/ LX3V/LX3VP/LX3VE/LX3VM|
... ... @@ -15,8 +15,9 @@
15 15  |Stop bit|1|
16 16  |PLC station No.|1|
17 17  
18 -**2)PLC Address List**
18 +**2)Address List**
19 19  
20 +
20 20  |**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note**
21 21  |(% rowspan="6" %)Bit|X|X|Xo|0~~303237|
22 22  |Y|Y|Y o|0~~303237|
... ... @@ -35,9 +35,9 @@
35 35  
36 36  **3)Configure the communication protocol**
37 37  
38 -[[image:image-20220824152217-1.png]]
39 +[[image:image-20220824152217-1.png||alt="图片-20220824152217-1.png"]]
39 39  
40 -**4)hardware connection**
41 +**4)Cable Wiring**
41 41  
42 42  * **RS422**
43 43  
... ... @@ -175,16 +175,112 @@
175 175  
176 176  The above are all the steps for establishing ethernet communication between V-BOX with LX5V PLC.
177 177  
178 -= **Rockwell PLC** =
179 += Create communication with **Rockwell PLC** =
179 179  
181 +== **DF1 Advanced Protocol** ==
182 +
183 +MicroLogix 1000/1100/1200/1400/1500; SLC 5/03 5/04 5/05; PLC-5
184 +
185 +**1) V-Box Settings**
186 +
187 +|=Item|=Recommended |=Note
188 +|=Protocol|Allen Bradley DF1 Advanced|
189 +|=Connection|RS232|
190 +|=Baud rate|19200|
191 +|=Stop bits|1|
192 +|=Data bits|8|
193 +|=Parity|None|
194 +|=PLC Station No.|1|
195 +|=HMI Station No.|0|
196 +
197 +**2) Address List**
198 +
199 +|=**Type**|=**Device registers**|=**Format**|=**Range**|=Note
200 +|(% colspan="1" rowspan="7" %)Bit|I1|I1ddd.dd|0.0~~255.15|Only able to communicate with file number I1
201 +|O0|O0ddd.dd|0.0~~255.15|Only able to communicate with file number O0
202 +|S2|S2ddd.dd|0.0~~255.15|Only able to communicate with file number S2
203 +|B3|B3ddd.dd|0.0~~255.15|Only able to communicate with file number B3
204 +|BN|BNddddd.dd|0.0~~99255.15|(((
205 +Bit data file B0~~B99
206 +
207 +First two digits is for file number
208 +
209 +For example, BN13001.00 represents file number B13, address 001, the 0th bit.
210 +)))
211 +|N7|N7ddd.dd|0.0~~255.15|Only able to communicate with file number N7
212 +|NN|NNddddd.dd|0.0~~99255.15|(((
213 +Integer data file bit format N0~~N99
214 +
215 +First two digits is for file number
216 +
217 +For example, NN13001.00 represents file number N13, address 001, the 0th bit.
218 +)))
219 +|(% rowspan="11" %)Word|S2|S2ddd|0~~255|Only able to communicate with file number S2
220 +|T4S|T4Sddd|0~~255|Only able to communicate with file number T4 (Timer Preset Value)
221 +|T4P|T4Pddd|0~~255|Only able to communicate with file number T4 (Timer Accumulator Value)
222 +|TNS|TNSddddd|0~~99255|(((
223 +Timer Preset Value
224 +
225 +First two digits is for file number
226 +
227 +For example, TNS99255 represents file number T99, address 255.
228 +)))
229 +|TNP|TNPddddd|0~~99255|(((
230 +Timer Accumulator Value
231 +
232 +First two digits is for file number
233 +
234 +For example, TNP99255 represents file number T99, address 255.
235 +)))
236 +|C5S|C5Sddd|0~~255|Only able to communicate with file number C5 (Counter Preset Value)
237 +|C5P|C5Pddd|0~~255|Only able to communicate with file number C5 (Counter Accumulator Value)
238 +|CNS|CNSddddd|0~~99255|(((
239 +Counter Preset Value
240 +
241 +First two digits is for file number
242 +
243 +For example, CNS99255 represents file number C99, address 255.
244 +)))
245 +|CNP|CNPddddd|0~~99255|(((
246 +Counter Accumulator Value
247 +
248 +First two digits is for file number
249 +
250 +For example, CNP99255 represents file number C99, address 255.
251 +)))
252 +|N7|N7ddd|0~~255|Only able to communicate with file number N7
253 +|NN|NNddd|0~~99255|(((
254 +Integer data file
255 +
256 +First two digits is for file number
257 +
258 +For example, NN99255 represents file number N99, address 255.
259 +)))
260 +|(% colspan="1" rowspan="3" %)Double Word|F8|F8ddd|0~~255|(((
261 +Only able to communicate with file number N7
262 +)))
263 +|FN|FNddddd|0~~99255|(((
264 +Floating point data file
265 +
266 +First two digits is for file number
267 +
268 +For example, FN99255 represents file number F99, address 255.
269 +)))
270 +|LN|LNddddd|0~~99255|Long
271 +
272 +**3) Cable Wiring**
273 +
274 +(% style="text-align:center" %)
275 +[[image:ABRS232.gif]]
276 +
180 180  == (% id="cke_bm_5621S" style="display:none" %)** **(%%)**MicroLogix Protocol** ==
181 181  
182 182  MicroLogix 1000/1100/1200/1400/1500; SLC 5/03 5/04 5/05 PLC-5
183 183  
184 -**1)PLC Settings**
281 +**1)V-BOX setting**
185 185  
186 186  |**Item**|**Settings**|**Note**
187 -|Protocol|Allen-Bradlley DF1 Advanced|
284 +|Protocol|Allen-Bradley DF1 Advanced|
188 188  |Connection|RS232|
189 189  |Baud rate|19200|
190 190  |Data bit|8|
... ... @@ -216,7 +216,7 @@
216 216  
217 217  [[image:image-20220824110724-1.png]]
218 218  
219 -== **CompactLogix Protocol** ==
316 +== **Micro850_FreeTag Protocol** ==
220 220  
221 221  (((
222 222  (((
... ... @@ -355,7 +355,7 @@
355 355  
356 356  (((
357 357  (((
358 -Open VNET client software → add device. As shown in the figure below, click "+" in the order of steps, and the Add Device window will pop up, enter the device machine code/product code, device password, and device alias to add the device.   [[image:image-20220714162752-8.png]]
455 +Open VNET client software → add device. As shown in the figure below, click "+" in the order of steps, and the Add Device window will pop up, enter the device machine code/product code, device password, and device alias to add the device.   [[image:image-20220714162752-8.png]]
359 359  )))
360 360  
361 361  
... ... @@ -419,12 +419,12 @@
419 419  The above are all the steps for establishing Ethernet communication between Wecon V-box with CompactLogix L1769 PLC.
420 420  
421 421  
422 -== **Allen-Bradley Ethernet DF1** ==
519 += **Allen-Bradley Ethernet DF1** =
423 423  
424 424  [[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Allen-Bradley%20Ethernet%20DF1.zip]]
425 425  
426 426  
427 -= **Siemens PLC** =
524 += Create communication with **Siemens PLC** =
428 428  
429 429  == **S7-200 Smart Ethernet Protocol** ==
430 430  
... ... @@ -435,7 +435,7 @@
435 435  
436 436  Supported Series: Siemens S7-300 series PLC
437 437  
438 -**1)PLC Setting**
535 +**1)V-BOX setting**
439 439  
440 440  |**Items**|**Settings**|**Note**
441 441  |Protocol|Simens S7-300 Ethernet|
... ... @@ -497,7 +497,7 @@
497 497  
498 498  Supported Series: Siemens S7-400, S7-1200 and S7-1500
499 499  
500 -**1)PLC Setting**
597 +**1)V-BOX setting**
501 501  
502 502  |=**Items**|=**Settings**|=**Note**
503 503  |Protocol|Siemens S7-XXX|
... ... @@ -607,9 +607,88 @@
607 607  
608 608  [[image:image-20220824162342-2.png]]
609 609  
707 +== **LOGO Ethernet Protocol** ==
610 610  
611 -= **Mitsubishi PLC** =
709 +Supported Series: Siemens Logo 0BA0, 0BA1 series
612 612  
711 +**V-BOX Settings**
712 +
713 +
714 +|**Items**|**Settings**|**Note**
715 +|Protocol|Siemens LOGO|
716 +|Connection|Ethernet|
717 +|Port No.|102|
718 +|PLC station No.|2|
719 +
720 +**Address List**
721 +
722 +
723 +|**Number**|**Address Type**|**Data Type**|**Range**|**DB Address**|**PLC Address**
724 +|1|RTC|Word|1-7|DB1.DBX984.0|0x001ec0
725 +|2|VB|Byte|0-1469|DB1.DBX0.0|0x000000
726 +|3|VD|Double Word|0-1466|DB1.DBX0.0|0x000000
727 +|4|VW|Word|0-1468|DB1.DBX0.0|0x000000
728 +|5|NAQ|Word|1-32|DB1.DBX1406.0|0x002bf0
729 +|6|NAI|Word|1-64|DB1.DBX1262.0|0x002770
730 +|7|AM|Word|1-64|DB1.DBX1118.0|0x0022f0
731 +|8|AQ|Word|1-16|DB1.DBX1072.0|0x002180
732 +|9|AI|Word|1-16|DB1.DBX1032.0|0x002040
733 +|10|I|Bit|1-64|DB1.DBX1024.0|0x002000
734 +|11|Q|Bit|1-64|DB1.DBX1064.0|0x002140
735 +|12|M|Bit|1-112|DB1.DBX1104.0|0x002280
736 +|13|NI|Bit|1-128|DB1.DBX1246.0|0x0026f0
737 +|14|NQ|Bit|1-128|DB1.DBX1390.0|0x002b70
738 +|15|V|Bit|0-14697|DB1.DBX0.0|0x000000
739 +
740 +**PLC Settings in LOGO Software:**
741 +
742 +Click [Tools]~-~-[Ethernet Connections],shown as below.
743 +
744 +(% style="text-align:center" %)
745 +[[image:PIStudio.12\.PLC protocols.WebHome@12.PLC Protocol_html_8b9d2322edf89519.png]]
746 +
747 +Set Ethernet connection parameter. IP, Subnet Mask, shown as below.
748 +
749 +(% style="text-align:center" %)
750 +[[image:PIStudio.12\.PLC protocols.WebHome@image-20221228142937-4.png]]
751 +
752 +**TSAP set**:The value set by local TSAP is the remote TSAP set in HMI. PLC's remote TSAP is the opposite,shown as below.
753 +
754 +(% style="text-align:center" %)
755 +[[image:PIStudio.12\.PLC protocols.WebHome@image-20221228143047-5.png]]
756 +
757 + **Download Project**: Click "Address book" to add the IP address to be downloaded (fi."Detect" to check whether the IP address can be detected. Then click “ok”, and the system will prompt that PLC will be "STOP" mode. Click “YES” to start download.
758 +
759 +(% style="text-align:center" %)
760 +[[image:PIStudio.12\.PLC protocols.WebHome@image-20221228143246-6.png]]
761 +
762 +**V-BOX Communication Settings**
763 +
764 +Set PLC IP in [IP Address] settings;
765 +
766 +(% style="text-align:center" %)
767 +[[image:LldwDGntf4.png]]
768 +
769 +Enable V-BOX Ethernet in [Network];
770 +
771 +(% style="text-align:center" %)
772 +[[image:WgvjfWbQif.png]]
773 +
774 +TSAP setting
775 +
776 +* The initialization script needs to set the source TSAP address and the target TSAP address, otherwise the communication will not be successful.
777 +
778 +{{code language="LUA"}}
779 +function init.main()
780 +    addr_setword("@W_0#HSW1200",8192) -- Set the source TSAP address
781 +
782 +    addr_setword("@W_0#HSW1201",4096) -- Set the destination TSAP address
783 +
784 +end
785 +{{/code}}
786 +
787 += Create communication with **Mitsubishi PLC** =
788 +
613 613  == **FX1S,1N,2N Serial Protocol** ==
614 614  
615 615  Supported Series: Mitsubishi FX1S, FX1N, FX2N series
... ... @@ -704,6 +704,101 @@
704 704  [[image:image-20220825100845-4.png]]
705 705  
706 706  
883 +== **FX3U Ethernet Protocol** ==
884 +
885 +Supported Modules: FX3U-ENET-ADP, FX3U-ENET-L
886 +
887 +**1)V-BOX Settings**
888 +
889 +|Items|Settings|Note
890 +|Protocol|Mitsubishi FX3U|
891 +|Connection|Ethernet|
892 +|Port No.|5009|Must be the same as the PLC setting
893 +|PLC station No.|0|
894 +
895 +**2)Address List**
896 +
897 +|**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note**
898 +|(% colspan="1" rowspan="7" %)Bit|X|X|X OOO|0~~377|
899 +|Y|Y|Y OOO|0~~377|
900 +|M|M|M DDDD|0~~7679|
901 +|SM|SM|SM DDDD|8000~~8511|
902 +|S|S|S DDDD|0~~4095|
903 +|TS|TS|TS DDD|0~~511|
904 +|CS|CS|CS DDD|0~~255|
905 +|(% colspan="1" rowspan="9" %)Word|CN|CN|CN DDD|0~~199|
906 +|TN|TN|TN DDD|0~~511|
907 +|D|D|D DDDD|0~~7999|
908 +|SD|SD|SD DDDD|8000~~8511|
909 +|R|R|R DDDDD|0~~32767|
910 +
911 +**3)Ethernet Module Settings**
912 +
913 +FX3U-ENET-L module configuration
914 +Set up the FX3U-ENET-L Ethernet module settings as follows.
915 +Select the module location, which in this document is Module 0.
916 +
917 +[[image:image-20221116105850-1.png]]
918 +
919 +Select "Operational setting" to enter the following screen.
920 +
921 +The Ethernet module IP is set to 192.168.39.254 in this document, and other options are default.
922 +
923 +[[image:image-20221116105947-1.png]]
924 +
925 +Select "Open setting" to enter the setting interface, the settings are as follows.
926 +
927 +The third item "Protocol" selects TCP, and "Open system" selects MELSOFT connection, which allows the
928 +
929 +Mitsubishi programming software GX works2 to communicate with the FX3U via the Ethernet module.
930 +
931 +[[image:image-20221116110802-1.png]]
932 +
933 +Click on "transter setup" - "PC side I/F setting", see the following figure.
934 +
935 +After setting, the first download must use the programming cable, as shown in the figure; after that, can
936 +
937 +use the IP set in the "Ethernet board" to communicate directly with the network cable.
938 +
939 +[[image:image-20221116110832-2.png||height="423" width="708"]]
940 +
941 +Read and write data from the Ethernet module
942 +
943 +[[image:image-20221116110907-3.png]]
944 +
945 +Set "Transter setup" to COM communication, and read or write operation as shown below
946 +
947 +[[image:image-20221116110917-4.png]]
948 +
949 +**4)PLC Settings (GX Works 2)**
950 +
951 +Create a blank FX5U project
952 +
953 +Find Current Connection in the navigation
954 +
955 +[[image:image-20221116111427-1.png||height="421" width="705"]]
956 +
957 +Select Connection Channel List
958 +
959 +Select Ethernet board communication
960 +
961 +[[image:image-20221116111451-2.png||height="421" width="705"]]
962 +
963 +Select Ethernet Module
964 +Set the IP address of the PLC
965 +
966 +[[image:image-20221116111509-3.png||height="666" width="699"]]
967 +
968 +Read or write PLC data, in this document is read
969 +
970 +[[image:image-20221116111651-4.png||height="416" width="697"]]
971 +
972 +[[image:image-20221116111727-5.png||height="416" width="697"]]
973 +
974 +**4)Configure the communication protocol**
975 +
976 +[[image:image-20221119101946-2.png||height="395" width="695"]]
977 +
707 707  == **FX5U Serial Protocol** ==
708 708  
709 709  Mitsubishi FX5U series PLC
... ... @@ -854,60 +854,863 @@
854 854  
855 855  [[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_c93025a968a8a9e7.png?width=600&height=434&rev=1.1||alt="12.PLC Protocol_html_c93025a968a8a9e7.png" height="434" width="600"]]
856 856  
857 -
858 858  **4)Configure the communication protocol**
859 859  
1130 +[[image:image-20220825112403-1.png||alt="图片-20220825112403-1.png"]]
860 860  
1132 +**5)Cable Wiring**
861 861  
1134 +[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_2297240b57346b2a.png?width=401&height=170&rev=1.1||alt="12.可编程逻辑控制器Protocol_html_2297240b57346b2a.png" height="170" width="401"]]
862 862  
1136 +== **L02 Serial Protocol** ==
1137 +
1138 +Mitsubishi L02 series CPU built-in serial port.
1139 +
1140 +**1)V-BOX Settings**
1141 +
1142 +|**Item**|**Settings**|**Note**
1143 +|Protocol|Mitsubishi L02|
1144 +|Connection|RS422|
1145 +|Baud rate|115200|
1146 +|Data bit|8|
1147 +|Parity|Odd|
1148 +|Stop bit|1|
1149 +|PLC station No.|1~~255|Need to be the same as PLC settings
1150 +
1151 +**2)Address List**
1152 +
1153 +|**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note**
1154 +|Bit|X|X|X h|0~~FFFF|
1155 +|Bit|Y|Y|Y h|0~~FFFF|
1156 +|Bit|M|M|M d|0~~9999|
1157 +|Bit|L|L|L d|0~~9999|
1158 +|Bit|F|F|F d|0~~9999|
1159 +|Bit|B|B|B h|0~~FFFF|
1160 +|Bit|V|V|V d|0~~2047|
1161 +|Bit|TC|TC|TC d|0~~9999|
1162 +|Bit|SS|SS|SS d|0~~9999|
1163 +|Bit|SC|SC|SC d|0~~9999|
1164 +|Bit|CS|CS|CS d|0~~9999|
1165 +|Bit|CC|CC|CC d|0~~9999|
1166 +|Bit|SB|SB|SB h|0~~FFFF|
1167 +|Bit|SM|SM|SM d|0~~2047|
1168 +|Bit|STS|STS|STS d|0~~1023|
1169 +|Bit|S|S|S d|0~~9999|
1170 +|Bit|DX|DX|DX h|0~~FFFF|
1171 +|Bit|DY|DY|DY h|0~~FFFF|
1172 +|Bit|TS|TS|TS d|0~~9999|
1173 +|Bit|Dbit|Dbit|Dbit d.d|0~~99999.0~~15|
1174 +|Word|W|W|W h|0~~FFFF|
1175 +|Word|TN|TN|TN d|0~~99999|
1176 +|Word|SN|SN|SN d|0~~99999|
1177 +|Word|CN|CN|CN d|0~~99999|
1178 +|Word|R|R|R d|0~~99999|
1179 +|Word|SW|SW|SW h|0~~FFFF|
1180 +|Word|Z|Z|Z d|0~~99999|
1181 +|Word|ZR|ZR|ZR h|0~~FFFF|
1182 +|Word|D|D|D d|0~~99999|
1183 +
1184 +**3)Communication Settings**
1185 +
1186 +[[image:image-20220825160648-3.png]]
1187 +
1188 +**4)Cable Wiring**
1189 +
1190 +* **RS422**
1191 +
1192 +[[image:image-20220825161612-8.png]]
1193 +
1194 +[[image:image-20220825160820-4.png]]
1195 +
1196 +== **L02 Ethernet Protocol** ==
1197 +
1198 +Mitsubishi L series CPU built-in Ethernet port.
1199 +
1200 +**1)V-BOX Settings**
1201 +
1202 +|**Items**|**Settings**|**Note**
1203 +|Protocol|MIT L02 CPU MELSEC|
1204 +|Connection|Ethernet|
1205 +|Port No.|1025|Must be the same as the PLC setting
1206 +|PLC station No.|0|Must be the same as the PLC setting
1207 +
1208 +**2)Address List**
1209 +
1210 +|**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note**
1211 +|Bit|X|X|X h|0~~FFFF|
1212 +|Bit|Y|Y|Y h|0~~FFFF|
1213 +|Bit|M|M|M d|0~~9999|
1214 +|Bit|L|L|L d|0~~9999|
1215 +|Bit|F|F|F d|0~~9999|
1216 +|Bit|B|B|B h|0~~FFFF|
1217 +|Bit|V|V|V d|0~~2047|
1218 +|Bit|TC|TC|TC d|0~~9999|
1219 +|Bit|SS|SS|SS d|0~~9999|
1220 +|Bit|SC|SC|SC d|0~~9999|
1221 +|Bit|CS|CS|CS d|0~~9999|
1222 +|Bit|CC|CC|CC d|0~~9999|
1223 +|Bit|SB|SB|SB h|0~~FFFF|
1224 +|Bit|SM|SM|SM d|0~~2047|
1225 +|Bit|STS|STS|STS d|0~~1023|
1226 +|Bit|S|S|S d|0~~9999|
1227 +|Bit|DX|DX|DX h|0~~FFFF|
1228 +|Bit|DY|DY|DY h|0~~FFFF|
1229 +|Bit|TS|TS|TS d|0~~9999|
1230 +|Bit|Dbit|Dbit|Dbit d.d|0~~99999.0~~15|
1231 +|Word|W|W|W h|0~~FFFF|
1232 +|Word|TN|TN|TN d|0~~99999|
1233 +|Word|SN|SN|SN d|0~~99999|
1234 +|Word|CN|CN|CN d|0~~99999|
1235 +|Word|R|R|R d|0~~99999|
1236 +|Word|SW|SW|SW h|0~~FFFF|
1237 +|Word|Z|Z|Z d|0~~99999|
1238 +|Word|ZR|ZR|ZR h|0~~FFFF|
1239 +|Word|D|D|D d|0~~99999|
1240 +
1241 +**3)PLC Settings (GX Works2 )**
1242 +
1243 +Create a project
1244 +
1245 +Set PLC IP, subnet mask and gateway;
1246 +
1247 +Select [Binary Code] as communication data code;
1248 +
1249 +[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_776e17505f3fc6c0.png?width=600&height=524&rev=1.1||alt="12.PLC Protocol_html_776e17505f3fc6c0.png" height="524" width="600"]]
1250 +
1251 +Set PLC port number, for example 1025
1252 +
1253 +[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_8d0d1a22d388f70b.png?width=600&height=524&rev=1.1||alt="12.PLC Protocol_html_8d0d1a22d388f70b.png" height="524" width="600"]]
1254 +
1255 +Save settings;
1256 +
1257 +Download project into PLC device;
1258 +
1259 +Restart PLC device;
1260 +
1261 +**4)Configure the communication protocol**
1262 +
1263 +[[image:image-20220825142659-1.png]]
1264 +
863 863  **5)Cable Wiring**
864 864  
865 865  [[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_2297240b57346b2a.png?width=401&height=170&rev=1.1||alt="12.PLC Protocol_html_2297240b57346b2a.png" height="170" width="401"]]
866 866  
867 -= **Delta PLC** =
1269 +== **Q12H Serial Protocol** ==
868 868  
1271 +This Demo shows V-BOX communicate with Q12H PLC by Q02H serial Protocol
1272 +
1273 +[[**Download link**>>https://ftp.we-con.com.cn/Download/WIKI/PI%20HMI/Demo/Communication/V-Box%20connect%20PLC%20Q12H.rar]]
1274 +
1275 +== **QJ71E71 Ethernet Protocol** ==
1276 +
1277 +Mitsubishi QJ71E71 Ethernet communication module;
1278 +
1279 +**1)V-BOX Settings**
1280 +
1281 +|**Items**|**Settings**|**Note**
1282 +|Protocol|MIT QJ71E71 MELSEC|
1283 +|Connection|Ethernet|
1284 +|Port No.|1025|Must be the same as the PLC setting
1285 +|PLC station No.|0|Must be the same as the PLC setting
1286 +
1287 +**2)Address List**
1288 +
1289 +|**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note**
1290 +|(% rowspan="18" %)Bit|X|X|X h|0~~1FFF|
1291 +|Y|Y|Y h|0~~1FFF|
1292 +|M|M|M d|0~~99999|
1293 +|L|L|L d|0~~8191|
1294 +|F|F|F d|0~~2047|
1295 +|B|B|B h|0~~1FFF|
1296 +|V|V|V d|0~~2047|
1297 +|TS|TS|TS d|0~~2047|
1298 +|TC|TC|TC d|0~~2047|
1299 +|SS|SS|SS d|0~~2047|
1300 +|SC|SC|SC d|0~~2047|
1301 +|CS|CS|CS d|0~~1023|
1302 +|CC|CC|CC d|0~~1023|
1303 +|SB|SB|SB h|0~~7FF|
1304 +|S|S|S d|0~~8191|
1305 +|DX|DX|DX h|0~~1FFF|
1306 +|DY|DY|DY h|0~~1FFF|
1307 +|SM|SM|SM d|8000~~9999|
1308 +|(% rowspan="10" %)Word|SD|SD|SD d|0~~2047|
1309 +|D|D|D d|0~~12287|
1310 +|W|W|W h|0~~1FFF|
1311 +|TN|TN|TN d|0~~2047|
1312 +|SN|SN|SN d|0~~2047|
1313 +|CN|CN|CN d|0~~1023|
1314 +|R|R|R d|0~~32767|
1315 +|SW|SW|SW h|0~~7FF|
1316 +|Z|Z|Z d|0~~15|
1317 +|ZR|ZR|ZR h|0~~FE7FF|
1318 +
1319 +**3)PLC Settings(GX Works2)**
1320 +
1321 +* Click [Ethernet/CC IE/MELSECNET];
1322 +* Please select [Ethernet] as network type;
1323 +* Set station I/O number according to situation (For example, 0020 means that the module is connected to PLC CPU in first order);
1324 +* Select [Online] as Mode;
1325 +* [[image:image-20221119171343-2.png||height="341" width="587"]]
1326 +* Click [Operation setting] to set IP;
1327 +* Select [Binary Code] as [Communication Data Code];
1328 +* [[image:image-20221119171436-3.png||height="354" width="588"]]
1329 +* Click [Open setting]
1330 +* Set protocol: TCP;
1331 +* Set [unpassive] in [Open system];
1332 +* Set [receive] in [Fixed buffer];
1333 +* Set [procedure Exist] in [Fixed buffer communication];
1334 +* Disable [Pairing open];
1335 +* Set [No confirm] in [Existence confirmation];
1336 +* Host station port number: 5009;
1337 +* Save settings;
1338 +* [[image:image-20221119171611-4.png||height="354" width="588"]]
1339 +* Download project into PLC and restart it
1340 +
1341 +**4)Configure the communication protocol**
1342 +
1343 +[[image:image-20221119171832-5.png||height="354" width="625"]]
1344 +
1345 +
1346 +**5)Cable Wiring**
1347 +
1348 +[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_2297240b57346b2a.png?width=401&height=170&rev=1.1||alt="12.PLC Protocol_html_2297240b57346b2a.png"]]
1349 +
1350 += Create communication with **Delta PLC** =
1351 +
869 869  == **DVP Ethernet Protocol** ==
870 870  
871 -[[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Delta%20DVP%20Ethernet.zip]]
1354 +Supoort Series: DELTA DVP20/32/40/60ES200RE/200TE or any DVP models with built-in Ethernet port, DELTA DVPEN01-SL module
872 872  
873 -== **DVP Serial Protocol** ==
1356 +**1)V-BOX Settings**
874 874  
875 -[[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Delta%20DVP%20Ethernet.zip]]
1358 +|=**Items**|=**Settings**|=**Note**
1359 +|Protocol|DELTA DVP MODBUS TCP|
1360 +|Connection|Ethernet|
1361 +|Port No.|502|
1362 +|Device No.|1|
1363 +|VBox Device No.|0|
876 876  
877 -= **Omron PLC** =
1365 +**2)Address List **
878 878  
879 -== **CP1 Series Protocol** ==
1367 +|=**Type**|=(% style="width: 191px;" %)**Device registers**|=(% style="width: 217px;" %)**VBox registers**|=(% style="width: 168px;" %)**Format**|=(% style="width: 225px;" %)**Range**|=**Note**
1368 +|Bit|(% style="width:191px" %)X|(% style="width:217px" %)X|(% style="width:168px" %)X OOO|(% style="width:225px" %)0~~377|
1369 +|Bit|(% style="width:191px" %)Y|(% style="width:217px" %)Y|(% style="width:168px" %)Y OOO|(% style="width:225px" %)0~~377|
1370 +|Bit|(% style="width:191px" %)M0|(% style="width:217px" %)M0|(% style="width:168px" %)M0DDDD|(% style="width:225px" %)0~~1535|
1371 +|Bit|(% style="width:191px" %)M1|(% style="width:217px" %)M1|(% style="width:168px" %)M1DDDD|(% style="width:225px" %)1536~~4096|
1372 +|Bit|(% style="width:191px" %)T|(% style="width:217px" %)T|(% style="width:168px" %)TDDD|(% style="width:225px" %)0~~255|
1373 +|Bit|(% style="width:191px" %)C|(% style="width:217px" %)C|(% style="width:168px" %)CDDD|(% style="width:225px" %)0~~255|
1374 +|Bit|(% style="width:191px" %)S|(% style="width:217px" %)S|(% style="width:168px" %)SDDDD|(% style="width:225px" %)0~~1023|
1375 +|Word|(% style="width:191px" %)D0|(% style="width:217px" %)D0|(% style="width:168px" %)D0DDDD|(% style="width:225px" %)0~~4095|
1376 +|Word|(% style="width:191px" %)D1|(% style="width:217px" %)D1|(% style="width:168px" %)D1DDDD|(% style="width:225px" %)4096~~11999|
1377 +|Word|(% style="width:191px" %)T|(% style="width:217px" %)T|(% style="width:168px" %)TDDD|(% style="width:225px" %)0~~255|
1378 +|Word|(% style="width:191px" %)C|(% style="width:217px" %)C|(% style="width:168px" %)CDDD|(% style="width:225px" %)0~~199|
1379 +|Double Word|(% style="width:191px" %)HC|(% style="width:217px" %)HC|(% style="width:168px" %)HCDDD|(% style="width:225px" %)200~~255|
880 880  
881 -[[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communication%20with%20ORMON%20CP1%20Series.zip]]
1381 +**3) PLC Setting:**
882 882  
883 -== **CJ2M Series Protocol** ==
1383 +~1. Create new project in Delta WPL Soft, and click Setting to open the communication settings:
884 884  
885 -[[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communication%20with%20ORMON%20CJ2M.zip]]
1385 +(% style="text-align:center" %)
1386 +[[image:DVPEthernetWPLSoft2.png]]
886 886  
887 -= **Modbus RTU** =
1388 +2. Set up the communication type and PLC IP:
888 888  
889 -== **V-BOX as master** ==
1390 +(% style="text-align:center" %)
1391 +[[image:DVPEthernetSetup.png]]
890 890  
891 -Select the protocol “(% class="mark" %)Modbus RTU Slave(All Fuction)”,
1393 +(% class="wikigeneratedid" %)
1394 +3. Click OK and save the settings. Then click Communication on toolbar, then click Transfer Setup to open new window:
892 892  
893 -(% class="mark" %)then set BaudRate,Port,Stop Bit,Data Bit,Parity
1396 +(% style="text-align:center" %)
1397 +[[image:DVPEthernetTransfer.png]]
894 894  
1399 +(% class="wikigeneratedid" %)
1400 +4. Select Communication Mode as PC => PLC to download or select PC <=PLC to upload:
1401 +
895 895  (% style="text-align:center" %)
1403 +[[image:DVPEthernetPLCtoPC.png]]
1404 +
1405 +5. Click Auto-Search Ethernet Module to find the PLC on the same LAN network:
1406 +
1407 +(% style="text-align:center" %)
1408 +[[image:DVPEthernetAutoSearch.png]]
1409 +
1410 +**4) V-BOX Setting:**
1411 +
1412 +Set the same IP address according to the setting from WPL Soft:
1413 +
1414 +(% style="text-align:center" %)
1415 +[[image:DVPEthernetVNETPortocol.png]]
1416 +
1417 +== **DVP serial protocol** ==
1418 +
1419 +Supoort Series: DELTA DVP EH/ES/SS/EX/EH2/SV/SA/SC/SX
1420 +
1421 +**1)V-BOX Settings**
1422 +
1423 +|=**Items**|=**Settings**|=**Note**
1424 +|Protocol|DELTA DVP PROTOCOL|
1425 +|Connection|RS232|
1426 +|Baud Rate|9600|
1427 +|Stop Bit|1|
1428 +|Data Bit|7|
1429 +|Parity|EVEN|
1430 +|Device No.|1|
1431 +
1432 +(% class="wikigeneratedid" %)
1433 +**2)Address List**
1434 +
1435 +|=**Type**|=(% style="width: 191px;" %)**Device registers**|=(% style="width: 217px;" %)**VBox registers**|=(% style="width: 168px;" %)**Format**|=(% style="width: 225px;" %)**Range**|=**Note**
1436 +|Bit|(% style="width:191px" %)X|(% style="width:217px" %)X|(% style="width:168px" %)X OOOOOO|(% style="width:225px" %)0~~303237|
1437 +|Bit|(% style="width:191px" %)Y|(% style="width:217px" %)Y|(% style="width:168px" %)Y OOOOOO|(% style="width:225px" %)0~~303237|
1438 +|Bit|(% style="width:191px" %)M|(% style="width:217px" %)M|(% style="width:168px" %)MDDDDD|(% style="width:225px" %)0~~99999|
1439 +|Bit|(% style="width:191px" %)T|(% style="width:217px" %)T|(% style="width:168px" %)TDDDDD|(% style="width:225px" %)0~~99999|
1440 +|Bit|(% style="width:191px" %)C|(% style="width:217px" %)C|(% style="width:168px" %)CDDDDD|(% style="width:225px" %)0~~99999|
1441 +|Bit|(% style="width:191px" %)S|(% style="width:217px" %)S|(% style="width:168px" %)SDDDDD|(% style="width:225px" %)0~~99999|
1442 +|Word|(% style="width:191px" %)D|(% style="width:217px" %)D|(% style="width:168px" %)D DDDDD|(% style="width:225px" %)0~~99999|
1443 +|Word|(% style="width:191px" %)T|(% style="width:217px" %)T|(% style="width:168px" %)TDDDDD|(% style="width:225px" %)0~~99999|
1444 +|Word|(% style="width:191px" %)C|(% style="width:217px" %)C|(% style="width:168px" %)CDDD|(% style="width:225px" %)0~~199|
1445 +|Double Word|(% style="width:191px" %)C|(% style="width:217px" %)C|(% style="width:168px" %)CDDDDD|(% style="width:225px" %)200~~99999|
1446 +
1447 +(% class="wikigeneratedid" %)
1448 +**3)Wiring Diagram**
1449 +
1450 +(% style="text-align:center" %)
1451 +[[image:Delta DVP PROTOCOLSerial232.png]]
1452 +
1453 +== **AS Ethernet Protocol** ==
1454 +
1455 +**1)V-BOX Settings**
1456 +
1457 +|=**Items**|=**Settings**|=**Note**
1458 +|Protocol|DELTA AS300 MODBUS TCP|
1459 +|Connection|Ethernet|
1460 +|Port No.|502|
1461 +|Device No.|1|
1462 +|HMI No.|0|
1463 +
1464 +**2)Address List**
1465 +
1466 +|**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note**
1467 +|Bit|X|X|X d|0~~63|
1468 +|Bit|Y|Y|Y d|0~~63|
1469 +|Bit|D|D|D d|0~~29999|
1470 +|Bit|M|M|M d|0~~8191|
1471 +|Bit|SM|SM|SM d|0~~4095|
1472 +|Bit|S|S|S h|0~~2047|
1473 +|Bit|T|T|T d|0~~511|
1474 +|Bit|C|C|C d|0~~511|
1475 +|Bit|HC|HC|HC d|0~~255|
1476 +|Word|X|X|X h|0~~63|
1477 +|Word|Y|Y|Y d|0~~63|
1478 +|Word|SR|SR|SR d|0~~2047|
1479 +|Word|D|D|D d|0~~29999|
1480 +|Word|T|T|T d|0~~511|
1481 +|Word|C|C|C h|0~~511|
1482 +|Word|E|E|E d|0~~9|
1483 +
1484 +**3)Configure the communication protocol**
1485 +
1486 +[[image:image-20220831160010-4.png]]
1487 +
1488 +**4)Cable Wiring**
1489 +
1490 +Figure
1491 +
1492 +[[image:image-20220831155101-1.png]][[image:image-20220831160055-5.png]]
1493 +
1494 +Pin Definition Diagram
1495 +
1496 +[[image:image-20220831155157-3.png]]
1497 +
1498 += Create communication with **Omron PLC** =
1499 +
1500 +== **CP1 Series Protocol ** ==
1501 +
1502 +[[下载链接>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communication%20with%20ORMON%20CP1%20Series.zip]]
1503 +
1504 +== **CP2M Series Protocol** ==
1505 +
1506 +[[下载链接>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communication%20with%20ORMON%20CJ2M.zip]]
1507 +
1508 +
1509 +== **EC55 Series Protocol** ==
1510 +
1511 +Supported device: EC55 temperature instrument
1512 +
1513 +**1)V-BOX Settings**
1514 +
1515 +|**Items**|**Settings**|**Note**
1516 +|Protocol|Omron EC55|
1517 +|Connection|RS485 (9600, 2, 7, EVEN)|
1518 +|Port No.|None|
1519 +|PLC station No.|0|
1520 +
1521 +**2)Address List**
1522 +
1523 +|**Type**|**Register**|**Device range**|**HMI range**|**Function**
1524 +|(% rowspan="3" %)Double word|C0|0-13 (Hex)|0-19|Set read only parameter for area 0
1525 +|C1|0-4D(Hex)|0-77|Set Read/Write parameter for area 0
1526 +|C3|0-CD(Hex)|0-205|Set Read/Write parameter for area 1
1527 +|(% rowspan="6" %)Word|80|0-13(Hex)|0-19|Set read only parameter in area 0
1528 +|81|0-4D(Hex)|0-77|Set Read/Write parameter in area 0
1529 +|83|0-CD(Hex)|0-205|Set Read/Write parameter in area 1
1530 +|CP|-|0-6|Read controller intrinsic property
1531 +|CS|-|0-2|Read controller states
1532 +|CA|-|0-17|Action command
1533 +
1534 +**3)Device Settings**
1535 +
1536 +Omron E5CC PLC configuration
1537 +
1538 +After entering the Communication Settings menu, please set the parameters to the default values for the following table. Press the cycle key of the instrument to enter the next setting.
1539 +
1540 +[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_3d95e093792ba98a.png?width=550&height=229&rev=1.1||alt="12.PLC Protocol_html_3d95e093792ba98a.png" height="229" width="550"]]
1541 +
1542 +According to PLC configuration and communication port configuration information of the HMI, provide the corresponding steps and configuration screenshots. This configuration needs to communicate properly with the above PLC configuration. The project settings are as follows
1543 +
1544 +[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_be583aa69dd6cf4c.png?width=550&height=242&rev=1.1||alt="12.PLC Protocol_html_be583aa69dd6cf4c.png" height="242" width="550"]]
1545 +
1546 +**✎Note:** The communication settings for HMI should be consistent with this setting.
1547 +
1548 +**4)Configure the communication protocol**
1549 +
1550 +[[image:image-20220831161041-1.png]]
1551 +
1552 +**5)Cable Wiring**
1553 +
1554 +[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_5e9a81a14106da9e.png?width=392&height=223&rev=1.1||alt="12.PLC Protocol_html_5e9a81a14106da9e.png" height="223" width="392"]]
1555 +
1556 +[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_1897d92be6948d58.png?width=393&height=223&rev=1.1||alt="12.PLC Protocol_html_1897d92be6948d58.png" height="223" width="393"]]
1557 +
1558 +**✎Note:**
1559 +
1560 +* COM3 only available in PI8000/PI9000 series.
1561 +* CA address could not support continuous writing function;
1562 +* Because of CP address intrinsic property: read control intrinsic property, so please place the character input part in use. Set address with CP0 and character length 10, used to display controller type. And place a number input part, set address with CP5 (cache size). Do not place other CP type address without CP0 in screen, otherwise CP type address is invalid
1563 +* When set value into read & write address, it is necessary to switch the temperature instrument meter to the corresponding interface according to the menu of the instrument where the address locates, so that the value could be written, otherwise, the value could not be written; When the communication write setting of the instrument is turned off, the writing function is invalid. Writing function could be opened by using the 00 address of the CA register, which write 01 value.
1564 +* When continuous writing of a value to a read-write address, please make sure all continuous writing address could be written. Otherwise, if one of these addresses could not be written, then all continuous writing commands will fail.
1565 +* Because of the mechanism problem, this protocol could not support CompoWay/F function that is read-write function of variables in protocol document.
1566 +* When using double-word address, set the data format to 32 bits, otherwise the read/write function is unable.
1567 +* Please set the communication delay time of 10ms in setting, to avoid that the instrument may not be able to communicate in a short time due to too fast data access and too much connection requests.
1568 +* [[image:image-20220831161356-1.png]]Because of the particularity of the instrument, it is necessary to write the value of the address in the menu interface corresponding to the address, and to enter the menu where the address locates, so that the value could be written.
1569 +
1570 += Create communication with Xinje** PLC** =
1571 +
1572 +== **XC serial protocol** ==
1573 +
1574 +**1)V-BOX Settings**
1575 +
1576 +|**Item**|**Settings**|**Note**
1577 +|Protocol|XINJE XC MODBUS|
1578 +|Connection|RS232|
1579 +|Baud rate|19200|
1580 +|Data bit|8|
1581 +|Parity|EVEN|
1582 +|Stop bit|1|
1583 +|PLC station No.|1|
1584 +
1585 +**2)Address List**
1586 +
1587 +|**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note**
1588 +|Bit|M|M|M d|0~~8511|
1589 +|Bit|X|X|X o|0~~1747|
1590 +|Bit|Y|Y|Y o|0~~1747|
1591 +|Bit|S|S|S d|0~~1023|
1592 +|Bit|T|T|T d|0~~4095|
1593 +|Bit|C|C|C d|0~~634|
1594 +|Word|D|D|D d|0~~8511|
1595 +|Word|TD|TD|TD d|0~~618|
1596 +|Word|CD|CD|CD d|0~~634|
1597 +|Word|FD|FD|FD d|0~~8511|
1598 +
1599 +**3)Configure the communication protocol**
1600 +
1601 +
1602 +[[image:image-20220831163041-1.png]]
1603 +
1604 +**4)Cable Wiring**
1605 +
1606 +Figure
1607 +
1608 +[[image:image-20220831163406-2.png]][[image:image-20220831163422-3.png]]
1609 +
1610 +Pin Definition Diagram
1611 +
1612 +[[image:image-20220831163441-4.png]]
1613 +
1614 +== **XD serial protocol** ==
1615 +
1616 +**1)V-BOX Settings**
1617 +
1618 +Supported Series: Xinjie XD/XE Series PLC
1619 +
1620 +|**Item**|**Settings**|**Note**
1621 +|Protocol|XINJE XD/XC MODBUS|
1622 +|Connection|RS232|
1623 +|Baud rate|19200|
1624 +|Data bit|8|
1625 +|Parity|EVEN|
1626 +|Stop bit|1|
1627 +|PLC station No.|1|
1628 +
1629 +**2)Address List**
1630 +
1631 +|**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note**
1632 +|Bit|M|M|M d|0~~74999|
1633 +|Bit|X1xx|X1xx|X1xx o|0~~1177|
1634 +|Bit|X2xx|X2xx|X2xx o|0~~277|
1635 +|Bit|X|X|X o|0~~77|
1636 +|Bit|Y1xx|Y1xx|Y1xx o|0~~1177|
1637 +|Bit|Y2xx|Y2xx|Y2xx o|0~~277|
1638 +|Bit|Y|Y|Y o|0~~4095|
1639 +|Bit|SM|SM|SM d|0~~4999|(((
1640 +
1641 +)))
1642 +|Bit|T|T|T d|0~~4999|
1643 +|Bit|C|C|C d|0~~4999|
1644 +|Bit|ET|ET|ET d|0~~31|
1645 +|Bit|SE|SE|SE d|0~~31|
1646 +|Bit|HM|HM|HM d|0~~11999|
1647 +|Bit|HSC|HSC|HSC d|0~~39|
1648 +|Bit|HS|HS|HS d|0~~999|
1649 +|Bit|HT|HT|HT d|0~~1999|
1650 +|Bit|HC|HC|HC d|0~~1999|
1651 +|Bit|S|S|S d|0~~7999|
1652 +|Word|D|D|D d|0~~69999|
1653 +|Word|ID|ID|ID d|0~~99|
1654 +|Word|ID1xx|ID1xx|ID1xx d|0~~999|
1655 +|Word|ID2xx|ID2xx|ID2xx d|0~~299|
1656 +|Word|QD|QD|QD d|0~~99|
1657 +|Word|QD1xx|QD1xx|QD1xx d|0~~999|
1658 +|Word|QD2xx|QD2xx|QD2xx d|0~~299|
1659 +|Word|SD|SD|SD d|0~~4999|
1660 +|Word|TD|TD|TD d|0~~575|
1661 +|Word|CD|CD|CD d|0~~575|
1662 +|Word|ETD|ETD|ETD d|0~~31|
1663 +|Word|HD|HD|HD d|0~~24999|
1664 +|Word|HSD|HSD|HSD d|0~~1023|
1665 +|Word|HTD|HTD|HTD d|0~~95|
1666 +|Word|HCD|HCD|HCD d|0~~95|
1667 +|Word|HSCD|HSCD|HSCD d|0~~31|
1668 +|Word|FD|FD|FD d|0~~8191|
1669 +|Word|SFD|SFD|SFD d|0~~5999|
1670 +|Word|FS|FS|FS d|0~~47|
1671 +
1672 +**3)Configure the communication protocol**
1673 +
1674 +[[image:image-20220831163923-7.png]]
1675 +
1676 +
1677 +
1678 +**4)Cable Wiring**
1679 +
1680 +Figure
1681 +
1682 +[[image:image-20220831163406-2.png]][[image:image-20220831163553-6.png]]
1683 +
1684 +Pin Definition Diagram
1685 +
1686 +[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/image-20220830160232-3.png?rev=1.1||alt="image-20220830160232-3.png"]]
1687 +
1688 += Create communication with **Schneider PLC** =
1689 +
1690 +== **Schneider MODBUS RTU** ==
1691 +
1692 +**1)V-BOX Setting**
1693 +
1694 +|=**Parameters**|=**Recommended**|=**Notes**
1695 +|**Protocol**|(% colspan="1" %)Schneider MODBUS RTU|
1696 +|**Connection**|RS485|
1697 +|**Baud rate**|19200|
1698 +|**Data bit**|8|
1699 +|**Parity**|Even|
1700 +|**Stop bit**|1|
1701 +|**PLC station No.**|1|
1702 +
1703 +**2)Address List**
1704 +
1705 +|=**Bit/Word**|=**Device type**|=**Format**|=**Range**|=**Memo**
1706 +|B|IX|DDDDDo|0 ~~ 655357|Input bit (read only)
1707 +|B|QX|DDDDDo|0 ~~ 655357|Write multiple coils
1708 +|B|MX|DDDDDDo|0 ~~ 9999997|Output register bit (octal)
1709 +|W|MW|DDDDDD|0 ~~ 999999|Output register
1710 +|DW|MD|DDDDDD|0 ~~ 999999|Output register
1711 +
1712 +**3)Configure the communication protocol**
1713 +
1714 +[[image:image-20220902104329-1.png]]
1715 +
1716 +**4)Cable Wiring**
1717 +
1718 +**RS-485 2W **(RJ45 Connector): The following is the view from the soldering point of a connector.
1719 +
1720 +[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/image-20220817154212-1.jpeg?width=554&height=315&rev=1.1||alt="image-20220817154212-1.jpeg" height="315" width="554"]]
1721 +
1722 += Create communication with Inovance** PLC** =
1723 +
1724 +== **H3U serial protocol** ==
1725 +
1726 +**1)V-BOX Settings**
1727 +
1728 +|**Item**|**Settings**|**Note**
1729 +|Protocol|INOVANCE H3U PLC|
1730 +|Connection|RS422|
1731 +|Baud rate|9600|
1732 +|Data bit|7|
1733 +|Parity|EVEN|
1734 +|Stop bit|1|
1735 +|PLC station No.|0|
1736 +
1737 +**2)Address List**
1738 +
1739 +|**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note**
1740 +|Bit|X|X|X o|0~~303237|
1741 +|Bit|Y|Y|Y o|0~~303237|
1742 +|Bit|M|M|M d|0~~99999|
1743 +|Bit|T|T|T d|0~~99999|
1744 +|Bit|C|C|C d|0~~99999|
1745 +|Bit|SM|SM|SM d|8000~~999|
1746 +|Bit|S|T|S d|0~~99999|
1747 +|Bit|Lamp|Lamp|Lamp d|0~~0|
1748 +|Word|X|X|X o|0~~303237|
1749 +|Word|Y|Y|Y o|0~~303237|
1750 +|Word|M|M|M d|0~~99999|
1751 +|Word|T|T|T d|0~~99999|
1752 +|Word|C|C|C d|0~~199|
1753 +|Word|D|D|D d|0~~7999|
1754 +|Word|S|S|S d|0~~99999|
1755 +|Word|SD|SD|SD d|8000~~9999|
1756 +|Word|R|R|R d|0~~32767|
1757 +
1758 +**3)Configure the communication protocol**
1759 +
1760 +[[image:image-20220831164626-1.png]]
1761 +
1762 +
1763 +
1764 +**4)Cable Wiring**
1765 +
1766 +Figure
1767 +
1768 +[[image:image-20220831164646-2.png]][[image:image-20220831164700-3.png]]
1769 +
1770 +Pin Definition Diagram
1771 +
1772 +[[image:image-20220831164731-4.png]]
1773 +
1774 += Create communication with Panasonic** PLC** =
1775 +
1776 +== **FP serial protocol** ==
1777 +
1778 +**1)V-BOX Settings**
1779 +
1780 +|**Item**|**Settings**|**Note**
1781 +|Protocol|Panasonic FP MFWTOCOL|
1782 +|Connection|RS232|
1783 +|Baud rate|9600|
1784 +|Data bit|8|
1785 +|Parity|ODD|
1786 +|Stop bit|1|
1787 +|PLC station No.|1|
1788 +
1789 +**2)Address List**
1790 +
1791 +|**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note**
1792 +|Bit|X|X|X d|0~~9999|
1793 +|Bit|Y|Y|Y d|0~~9999|
1794 +|Bit|R|R|R d|0~~9999|
1795 +|Bit|T|T|T d|0~~9999|
1796 +|Bit|C|C|C d|0~~9999|
1797 +|Bit|L|L|L d|0~~9999|
1798 +|Word|WX|WX|WX d|0~~9999|
1799 +|Word|WY|WY|WY d|0~~9999|
1800 +|Word|WR|WR|WR d|0~~9999|
1801 +|Word|WL|WL|WL d|0~~9999|
1802 +|Word|LD|LD|LD d|0~~9999|
1803 +|Word|DT|DT|DT d|0~~65535|
1804 +|Word|FL|FL|FL d|0~~9999|
1805 +|Word|EV|EV|EV d|0~~9999|
1806 +|Word|SV|SV|SV d|0~~9999|
1807 +
1808 +**3)Configure the communication protocol**
1809 +
1810 +[[image:image-20220831165238-4.png]]
1811 +
1812 +
1813 +
1814 +**4)Cable Wiring**
1815 +
1816 +Figure
1817 +
1818 +[[image:image-20220831165031-3.png]][[image:image-20220831165017-2.png]]
1819 +
1820 +Pin Definition Diagram
1821 +
1822 +[[image:image-20220831165008-1.png]]
1823 +
1824 += Create communication with LS** PLC** =
1825 +
1826 +== **XBC serial protocol** ==
1827 +
1828 +**1)V-BOX Settings**
1829 +
1830 +|**Item**|**Settings**|**Note**
1831 +|Protocol|LS XBC CNet|
1832 +|Connection|RS232|
1833 +|Baud rate|115200|
1834 +|Data bit|8|
1835 +|Parity|NONE|
1836 +|Stop bit|1|
1837 +|PLC station No.|1|
1838 +
1839 +**2)Address List**
1840 +
1841 +|**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note**
1842 +|Bit|P|P|P d|0~~2047|
1843 +|Bit|M|M|M d|0~~2047|
1844 +|Bit|L|L|L d|0~~11263|
1845 +|Bit|K|K|K d|0~~16183|
1846 +|Bit|F|F|F d|0~~2047|
1847 +|Bit|D|D|D d|0~~32767|
1848 +|Bit|R|R|R d|0~~32767|
1849 +|Bit|U|U|U d|0~~4095|
1850 +|Word|P|P|P d|0~~2047|
1851 +|Word|M|M|M d|0~~2047|
1852 +|Word|L|L|L d|0~~11263|
1853 +|Word|K|K|K d|0~~16183|
1854 +|Word|F|F|F d|0~~2047|
1855 +|Word|C|C|C d|0~~2047|
1856 +|Word|T|T|T d|0~~2047|
1857 +|Word|D|D|D d|0~~32767|
1858 +|Word|N|N|N d|0~~21503|
1859 +|Word|R|R|R d|0~~32767|
1860 +|Word|U|U|U d|0~~4095|
1861 +|Word|Z|Z|Z d|0~~127|
1862 +|Word|S|S|S d|0~~127|
1863 +
1864 +**3)Configure the communication protocol**
1865 +
1866 +[[image:image-20220831170147-1.png]]
1867 +
1868 +**4)Cable Wiring**
1869 +
1870 +Figure
1871 +
1872 +[[image:image-20220831170306-4.png]][[image:image-20220831170254-3.png]]
1873 +
1874 +Pin Definition Diagram
1875 +
1876 +[[image:image-20220831170215-2.png]]
1877 +
1878 +== **XGK FEnet Ethernet protocol** ==
1879 +
1880 +Supported Series: LS XGT series XGK CPU with XGL-EFMT Ethernet module
1881 +
1882 +**1)V-BOX Settings**
1883 +
1884 +|**Items**|**Settings**|**Note**
1885 +|Protocol|LG XGK FEnet(Ethernet)|
1886 +|Connection|Ethernet|
1887 +|Port No.|2004|
1888 +
1889 +**2)Address List**
1890 +
1891 +|**Type**|**Register**|**Range**|**Format**|**Note**
1892 +|(% rowspan="14" %)Word|P|0~~2047|P d|
1893 +|M|0~~2047|M d|
1894 +|K|0~~2047|K d|
1895 +|F|0~~2047|F d|
1896 +|T|0~~2047|T d|
1897 +|C|0~~2047|C d|
1898 +|Z|0~~127|Z d|
1899 +|S|0~~127|S d|
1900 +|L|0~~11263|L d|
1901 +|N|0~~21503|N d|
1902 +|D|0~~32767|D d|
1903 +|R|0~~32767|R d|
1904 +|ZR|0~~65535|ZR d|
1905 +|UxDD|0~~6331|UxDD nndd|nn: 0~~63, dd: 0~~31
1906 +
1907 +**✎Note:**
1908 +
1909 +* In addition to the "UxDD" register, the others correspond to the PLC register one by one. UxDD corresponds to U in the PLC;
1910 +* The [UxDD] register, defined in the PLC is Ux.dd, x represents the block, and dd represents 0-31 of each block. There are 64 blocks in the PLC;
1911 +* All bit registers are in the form of bits in word, and the range is the same as the word register;
1912 +
1913 +**3)Communication Settings**
1914 +
1915 +[[image:image-20220831171127-1.png]]
1916 +
1917 +**4)Cable Wiring**
1918 +
1919 +[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_2297240b57346b2a.png?width=401&height=170&rev=1.1||alt="12.可编程逻辑控制器Protocol_html_2297240b57346b2a.png" height="170" width="401"]]
1920 +
1921 += Create communication with **Modbus ** =
1922 +
1923 +== **MODBUS RTU Slave (All function)** ==
1924 +
1925 +Select the protocol "Modbus RTU Slave (All Fuction)",
1926 +
1927 +Then set baud rate, port, stop bits, data bits, parity.
1928 +
1929 +(% style="text-align:center" %)
896 896  [[image:1624342015914-382.png||height="486" width="800" class="img-thumbnail"]]
897 897  
898 -== **V-BOX as slave** ==
1932 +== **MODBUS RTU Master** ==
899 899  
900 -Select the protocol “(% class="mark" %)**Modbus RTU Master”**,
1934 +Select the protocol "Modbus RTU Master",
901 901  
902 -(% class="mark" %)then set BaudRate,Port,Stop Bit,Data Bit,Parity
1936 +Then set baud rate, port, stop bits, data bits, parity
903 903  
904 904  (% style="text-align:center" %)
905 905  [[image:1624348709622-711.png||queryString="width=809&height=493" height="488" width="800" class="img-thumbnail"]]
906 906  
907 -**Address List**
1941 +**address list**
908 908  
909 909  (% class="table-bordered" %)
910 -|**Type**|**Register**|**Function code & Description**
1944 +|=(% scope="row" %)**Type**|=**Data Type**|=**Function code and description**
1945 +|(% rowspan="11" %)Word|(% rowspan="3" %)3|04 (Read Input Registers: Read the current binary value in one or more input registers)
1946 +|06 (write single register: write a binary value to a holding register)
1947 +|10 (write values to multiple addresses )
1948 +|(% rowspan="3" %)4|03 (read holding register: read current binary value in one or more holding registers)
1949 +|06 (write single register: write a binary value to a holding register)
1950 +|10 (write values to multiple addresses )
1951 +|(% rowspan="3" %)W6|03 (read holding register: read current binary value in one or more holding registers)
1952 +|06 (write single register: write a binary value to a holding register)
1953 +|10 (write values to multiple addresses )
1954 +|(% rowspan="2" %)W16|03 (read holding register: read current binary value in one or more holding registers)
1955 +|10 (write values to multiple addresses )
1956 +|(% rowspan="11" %)Bit|(% rowspan="3" %)0|01 (Read coil state)
1957 +|05 (Force a single coil to force the on/off state of a logic coil)
1958 +|0F (Write multiple bits, ie write continuously)
1959 +|(% rowspan="3" %)1|02 (Read the input state)
1960 +|05 (Force a single coil to force the on/off state of a logic coil)
1961 +|0F (Write multiple bits)
1962 +|(% rowspan="3" %)W5|01 (Read coil state to obtain the current state of a set of logic coils)
1963 +|05 (Force a single coil to force the on/off state of a logic coil)
1964 +|0F (Write multiple bits)
1965 +|(% rowspan="2" %)W15|01 (Read coil state to obtain the current state of a set of logic coils)
1966 +|0F (Write multiple bits)
1967 +
1968 +== **MODBUS TCP Slave (All function)** ==
1969 +
1970 +Supported series: MODBUS TCP controller
1971 +
1972 +V-B0X works as MODBUS TCP MASTER connecting with TCP SLAVE
1973 +
1974 +**1)V-BOX Setting**
1975 +
1976 +|**Items**|**Settings**|**Note**
1977 +|Protocol|MODBUS TCP Slave (All function)|
1978 +|Connection|Ethernet|
1979 +|Port No.|502|
1980 +|PLC station No.|1
1981 +
1982 +**2)Address List**
1983 +
1984 +|=**Type**|=**Data Type**|=**Function code & Description**
911 911  |(% rowspan="11" %)Word|(% rowspan="3" %)3|04 (read input register: read current binary value in one or more input registers)
912 912  |06 (write single register: write a binary value to a holding register)
913 913  |10 (write values to multiple addresses )
... ... @@ -931,6 +931,21 @@
931 931  |(% rowspan="2" %)W15|01 (Read coil state to obtain the current state of a set of logic coils)
932 932  |0F (Write multiple bits)
933 933  
2008 +**3)Communication Settings**
2009 +
2010 +Configure V-BOX Ethernet IP in Networking Settings
2011 +
2012 +[[image:image-20220902111833-3.png]]
2013 +
2014 +
2015 +Configure PLC Ethernet IP in Communication;
2016 +
2017 +[[image:image-20220902111121-1.png]]
2018 +
2019 +**4)Cable Wiring**
2020 +
2021 +[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_2297240b57346b2a.png?width=401&height=170&rev=1.1||alt="12.PLC Protocol_html_2297240b57346b2a.png" height="170" width="401"]]
2022 +
934 934  == **communicate with VB inverter** ==
935 935  
936 936  [[download link>>url:https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communicate%20with%20VB%20inverter.zip]]
0Il1q9GZgk.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Bob
Size
... ... @@ -1,0 +1,1 @@
1 +24.6 KB
Content
AB.gif
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Hunter
Size
... ... @@ -1,0 +1,1 @@
1 +7.3 KB
Content
ABRS232.gif
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Hunter
Size
... ... @@ -1,0 +1,1 @@
1 +7.3 KB
Content
DVPEthernetAutoSearch.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Hunter
Size
... ... @@ -1,0 +1,1 @@
1 +43.6 KB
Content
DVPEthernetPLCtoPC.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Hunter
Size
... ... @@ -1,0 +1,1 @@
1 +8.9 KB
Content
DVPEthernetSetup.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Hunter
Size
... ... @@ -1,0 +1,1 @@
1 +19.9 KB
Content
DVPEthernetTransfer.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Hunter
Size
... ... @@ -1,0 +1,1 @@
1 +59.9 KB
Content
DVPEthernetVNETPortocol.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Hunter
Size
... ... @@ -1,0 +1,1 @@
1 +21.4 KB
Content
DVPEthernetWPLSoft.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Hunter
Size
... ... @@ -1,0 +1,1 @@
1 +97.5 KB
Content
DVPEthernetWPLSoft2.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Hunter
Size
... ... @@ -1,0 +1,1 @@
1 +45.2 KB
Content
Delta DVP PROTOCOLSerial232.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Hunter
Size
... ... @@ -1,0 +1,1 @@
1 +10.7 KB
Content
LldwDGntf4.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Bob
Size
... ... @@ -1,0 +1,1 @@
1 +24.3 KB
Content
WgvjfWbQif.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Bob
Size
... ... @@ -1,0 +1,1 @@
1 +36.3 KB
Content
image-20220825112403-1.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +128.1 KB
Content
image-20220825142437-1.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +126.5 KB
Content
image-20220825142659-1.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +124.2 KB
Content
image-20220825143728-1.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +124.7 KB
Content
image-20220825160227-1.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +148.8 KB
Content
image-20220825160341-2.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +121.7 KB
Content
image-20220825160648-3.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +122.7 KB
Content
image-20220825160820-4.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +24.9 KB
Content
image-20220825160925-5.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +31.0 KB
Content
image-20220825160929-6.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +31.0 KB
Content
image-20220825161440-7.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +90.7 KB
Content
image-20220825161612-8.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +86.3 KB
Content
image-20220831155101-1.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +34.6 KB
Content
image-20220831155129-2.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +44.9 KB
Content
image-20220831155157-3.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +20.8 KB
Content
image-20220831160010-4.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +59.6 KB
Content
image-20220831160055-5.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +51.5 KB
Content
image-20220831161041-1.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +58.1 KB
Content
image-20220831161356-1.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +27.0 KB
Content
image-20220831163041-1.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +58.6 KB
Content
image-20220831163406-2.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +28.4 KB
Content
image-20220831163422-3.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +53.9 KB
Content
image-20220831163441-4.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +13.7 KB
Content
image-20220831163548-5.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +37.1 KB
Content
image-20220831163553-6.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +37.1 KB
Content
image-20220831163923-7.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +57.3 KB
Content
image-20220831164626-1.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +56.1 KB
Content
image-20220831164646-2.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +28.4 KB
Content
image-20220831164700-3.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +66.6 KB
Content
image-20220831164731-4.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +12.3 KB
Content
image-20220831165008-1.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +13.3 KB
Content
image-20220831165017-2.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +36.2 KB
Content
image-20220831165031-3.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +28.3 KB
Content
image-20220831165238-4.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +57.4 KB
Content
image-20220831170147-1.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +57.1 KB
Content
image-20220831170215-2.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +14.3 KB
Content
image-20220831170254-3.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +43.5 KB
Content
image-20220831170306-4.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +28.5 KB
Content
image-20220831171127-1.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +60.1 KB
Content
image-20220902104329-1.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +58.7 KB
Content
image-20220902111121-1.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +60.9 KB
Content
image-20220902111754-2.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +57.6 KB
Content
image-20220902111833-3.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +56.1 KB
Content
image-20221116105850-1.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Bob
Size
... ... @@ -1,0 +1,1 @@
1 +18.9 KB
Content
image-20221116105947-1.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Bob
Size
... ... @@ -1,0 +1,1 @@
1 +18.7 KB
Content
image-20221116110802-1.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Bob
Size
... ... @@ -1,0 +1,1 @@
1 +16.4 KB
Content
image-20221116110832-2.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Bob
Size
... ... @@ -1,0 +1,1 @@
1 +42.2 KB
Content
image-20221116110907-3.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Bob
Size
... ... @@ -1,0 +1,1 @@
1 +17.8 KB
Content
image-20221116110917-4.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Bob
Size
... ... @@ -1,0 +1,1 @@
1 +23.2 KB
Content
image-20221116111427-1.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Bob
Size
... ... @@ -1,0 +1,1 @@
1 +63.4 KB
Content
image-20221116111451-2.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Bob
Size
... ... @@ -1,0 +1,1 @@
1 +225.5 KB
Content
image-20221116111509-3.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Bob
Size
... ... @@ -1,0 +1,1 @@
1 +34.1 KB
Content
image-20221116111651-4.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Bob
Size
... ... @@ -1,0 +1,1 @@
1 +74.3 KB
Content
image-20221116111727-5.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Bob
Size
... ... @@ -1,0 +1,1 @@
1 +106.2 KB
Content
image-20221116114106-1.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Bob
Size
... ... @@ -1,0 +1,1 @@
1 +99.5 KB
Content
image-20221119101759-1.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Bob
Size
... ... @@ -1,0 +1,1 @@
1 +62.1 KB
Content
image-20221119101946-2.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Bob
Size
... ... @@ -1,0 +1,1 @@
1 +68.7 KB
Content
image-20221119171318-1.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Bob
Size
... ... @@ -1,0 +1,1 @@
1 +90.3 KB
Content
image-20221119171343-2.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Bob
Size
... ... @@ -1,0 +1,1 @@
1 +90.3 KB
Content
image-20221119171436-3.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Bob
Size
... ... @@ -1,0 +1,1 @@
1 +43.4 KB
Content
image-20221119171611-4.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Bob
Size
... ... @@ -1,0 +1,1 @@
1 +23.1 KB
Content
image-20221119171832-5.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Bob
Size
... ... @@ -1,0 +1,1 @@
1 +69.6 KB
Content