Changes for page 1 Communication
Last modified by Hunter on 2024/07/01 10:54
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 2 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -1,43 +1,43 @@ 1 -= (% style="color:inherit; font-family:inherit" %)** WECON PLC**(%%) =1 += (% style="color:inherit; font-family:inherit" %)**维控公司**(%%) = 2 2 3 -== **LX3V SerialProtocol** ==3 +== **LX3V 串行协议** == 4 4 5 - Supportedseries: WECONLX2V/ LX2E/ LX3V/LX3VP/LX3VE/LX3VM5 +支持系列:维控 LX2V/ LX2E/ LX3V/LX3VP/LX3VE/LX3VM 6 6 7 -**1) PLC Settings**7 +**1)可编程逻辑控制器设置** 8 8 9 -|** Item**|**Settings**|**Note**10 -| Protocol|WECONLX2V/ LX2E/ LX3V/LX3VP/LX3VE/LX3VM|11 -| Connection|RS422/RS485|12 -| Baud rate|9600|13 -| Data bit|7|14 -| Parity|EVEN|15 -| Stop bit|1|16 -|PLC station No.|1|9 +|**项目**|**设置**|**注意** 10 +|协议|维控 LX2V/ LX2E/ LX3V/LX3VP/LX3VE/LX3VM| 11 +|连接|RS422/RS485| 12 +|波特率|9600| 13 +|数据位|7| 14 +|平价|甚至| 15 +|停止位|1| 16 +|PLC站号|1| 17 17 18 -**2) PLC Address List**18 +**2)可编程逻辑控制器地址列表** 19 19 20 -|** Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note**21 -|(% rowspan="6" %) Bit|X|X|Xo|0~~303237|20 +|**类型**|**设备寄存器**|**人机界面寄存器**|**格式**|**范围**|**注意** 21 +|(% rowspan="6" %)位|X|X|断续器|0~~303237| 22 22 |Y|Y|Y o|0~~303237| 23 23 |M|M|M d|0~~99999| 24 -|T|T| Td|0~~99999|25 -|C|C| C d|0~~99999|26 -|S|S| S d|0~~99999|27 -|(% rowspan="8" %) Word|X|X|Xo|0~~303237|24 +|T|T|S C|0~~99999| 25 +|C|C|断续器|0~~99999| 26 +|S|S|断续器|0~~99999| 27 +|(% rowspan="8" %)词|X|X|断续器|0~~303237| 28 28 |Y|Y|Y o|0~~303237| 29 29 |M|M|M d|0~~99999| 30 -|T|T| Td|0~~99999|31 -|C|C| C d|0~~199|32 -|D|D| Dd|0~~7999|33 -|S|S| S d|0~~99999|34 -| SD|SD|SDd|8000~~9999|30 +|T|T|S C|0~~99999| 31 +|C|C|断续器|0~~199| 32 +|D|D|C C|0~~7999| 33 +|S|S|断续器|0~~99999| 34 +|标清|标清|标清 d|8000~~9999| 35 35 36 -**3) Configure the communication protocol**36 +**3)配置通信协议** 37 37 38 -[[image:image-20220824152217-1.png]] 38 +[[image:image-20220824152217-1.png||alt="图片-20220824152217-1.png"]] 39 39 40 -**4) hardware connection**40 +**4)硬件连接** 41 41 42 42 * **RS422** 43 43 ... ... @@ -216,7 +216,7 @@ 216 216 217 217 [[image:image-20220824110724-1.png]] 218 218 219 -== ** CompactLogix Protocol** ==219 +== **Micro850_FreeTag** == 220 220 221 221 ((( 222 222 ((( ... ... @@ -355,7 +355,7 @@ 355 355 356 356 ((( 357 357 ((( 358 -Open VNET client software → add device. As shown in the figure below, click "+" in the order of steps, and the Add Device window will pop up, enter the device machine code/product code, device password, and device alias to add the device. 358 +Open VNET client software → add device. As shown in the figure below, click "+" in the order of steps, and the Add Device window will pop up, enter the device machine code/product code, device password, and device alias to add the device. [[image:image-20220714162752-8.png]] 359 359 ))) 360 360 361 361 ... ... @@ -856,57 +856,206 @@ 856 856 857 857 **4)Configure the communication protocol** 858 858 859 -[[image:image-20220825112403-1.png]] 859 +[[image:image-20220825112403-1.png||alt="图片-20220825112403-1.png"]] 860 860 861 +**5)电缆布线** 862 + 863 +[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_2297240b57346b2a.png?width=401&height=170&rev=1.1||alt="12.可编程逻辑控制器Protocol_html_2297240b57346b2a.png" height="170" width="401"]] 864 + 865 +== **L02 Ethernet Protocol** == 866 + 867 +Mitsubishi L series CPU built-in Ethernet port. 868 + 869 +**1)V-BOX Settings** 870 + 871 +|**Items**|**Settings**|**Note** 872 +|Protocol|MIT L02 CPU MELSEC| 873 +|Connection|Ethernet| 874 +|Port No.|1025|Must be the same as the PLC setting 875 +|PLC station No.|0|Must be the same as the PLC setting 876 + 877 +**2)Address List** 878 + 879 +|**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note** 880 +|Bit|X|X|X h|0~~FFFF| 881 +|Bit|Y|Y|Y h|0~~FFFF| 882 +|Bit|M|M|M d|0~~9999| 883 +|Bit|L|L|L d|0~~9999| 884 +|Bit|F|F|F d|0~~9999| 885 +|Bit|B|B|B h|0~~FFFF| 886 +|Bit|V|V|V d|0~~2047| 887 +|Bit|TC|TC|TC d|0~~9999| 888 +|Bit|SS|SS|SS d|0~~9999| 889 +|Bit|SC|SC|SC d|0~~9999| 890 +|Bit|CS|CS|CS d|0~~9999| 891 +|Bit|CC|CC|CC d|0~~9999| 892 +|Bit|SB|SB|SB h|0~~FFFF| 893 +|Bit|SM|SM|SM d|0~~2047| 894 +|Bit|STS|STS|STS d|0~~1023| 895 +|Bit|S|S|S d|0~~9999| 896 +|Bit|DX|DX|DX h|0~~FFFF| 897 +|Bit|DY|DY|DY h|0~~FFFF| 898 +|Bit|TS|TS|TS d|0~~9999| 899 +|Bit|Dbit|Dbit|Dbit d.d|0~~99999.0~~15| 900 +|Word|W|W|W h|0~~FFFF| 901 +|Word|TN|TN|TN d|0~~99999| 902 +|Word|SN|SN|SN d|0~~99999| 903 +|Word|CN|CN|CN d|0~~99999| 904 +|Word|R|R|R d|0~~99999| 905 +|Word|SW|SW|SW h|0~~FFFF| 906 +|Word|Z|Z|Z d|0~~99999| 907 +|Word|ZR|ZR|ZR h|0~~FFFF| 908 +|Word|D|D|D d|0~~99999| 909 + 910 +**3)Configure the communication protocol** 911 + 912 +[[image:image-20220825142659-1.png]] 913 + 914 +**4)PLC Settings (GX Works2 )** 915 + 916 +Create a project 917 + 918 +Set PLC IP, subnet mask and gateway; 919 + 920 +Select [Binary Code] as communication data code; 921 + 922 +[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_776e17505f3fc6c0.png?width=600&height=524&rev=1.1||alt="12.PLC Protocol_html_776e17505f3fc6c0.png" height="524" width="600"]] 923 + 924 +Set PLC port number, for example 1025 925 + 926 +[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_8d0d1a22d388f70b.png?width=600&height=524&rev=1.1||alt="12.PLC Protocol_html_8d0d1a22d388f70b.png" height="524" width="600"]] 927 + 928 +Save settings; 929 + 930 +Download project into PLC device; 931 + 932 +Restart PLC device; 933 + 861 861 **5)Cable Wiring** 862 862 863 863 [[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_2297240b57346b2a.png?width=401&height=170&rev=1.1||alt="12.PLC Protocol_html_2297240b57346b2a.png" height="170" width="401"]] 864 864 865 -= ** DeltaPLC** =938 +== **QJ71E71 Ethernet Protocol** == 866 866 867 - ==**DVPEthernetProtocol** ==940 +Mitsubishi QJ71E71 Ethernet communication module; 868 868 869 - [[download link>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Delta%20DVP%20Ethernet.zip]]942 +**V-BOX Settings** 870 870 871 -== **DVP Serial Protocol** == 944 +|**Items**|**Settings**|**Note** 945 +|Protocol|MIT QJ71E71 MELSEC| 946 +|Connection|Ethernet| 947 +|Port No.|1025|Must be the same as the PLC setting 948 +|PLC station No.|0|Must be the same as the PLC setting 872 872 873 - [[downloadlink>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Delta%20DVP%20Ethernet.zip]]950 +**Address List** 874 874 875 -= **Omron PLC** = 952 +|**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note** 953 +|(% rowspan="18" %)Bit|X|X|X h|0~~1FFF| 954 +|Y|Y|Y h|0~~1FFF| 955 +|M|M|M d|0~~99999| 956 +|L|L|L d|0~~8191| 957 +|F|F|F d|0~~2047| 958 +|B|B|B h|0~~1FFF| 959 +|V|V|V d|0~~2047| 960 +|TS|TS|TS d|0~~2047| 961 +|TC|TC|TC d|0~~2047| 962 +|SS|SS|SS d|0~~2047| 963 +|SC|SC|SC d|0~~2047| 964 +|CS|CS|CS d|0~~1023| 965 +|CC|CC|CC d|0~~1023| 966 +|SB|SB|SB h|0~~7FF| 967 +|S|S|S d|0~~8191| 968 +|DX|DX|DX h|0~~1FFF| 969 +|DY|DY|DY h|0~~1FFF| 970 +|SM|SM|SM d|8000~~9999| 971 +|(% rowspan="10" %)Word|SD|SD|SD d|0~~2047| 972 +|D|D|D d|0~~12287| 973 +|W|W|W h|0~~1FFF| 974 +|TN|TN|TN d|0~~2047| 975 +|SN|SN|SN d|0~~2047| 976 +|CN|CN|CN d|0~~1023| 977 +|R|R|R d|0~~32767| 978 +|SW|SW|SW h|0~~7FF| 979 +|Z|Z|Z d|0~~15| 980 +|ZR|ZR|ZR h|0~~FE7FF| 876 876 877 - ==**CP1SeriesProtocol**==982 +**HMI Communication Settings** 878 878 879 - [[downloadlink>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communication%20with%20ORMON%20CP1%20Series.zip]]984 +1) Enable HMI Ethernet in [Project Settings]; 880 880 881 -== **CJ2M Series Protocol** == 882 882 883 - [[downloadlink>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communication%20with%20ORMON%20CJ2M.zip]]987 +2) Set PLC IP in [Device IP] settings; 884 884 989 +[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_2d566cb5ffb2618c.png?width=554&height=190&rev=1.1||alt="12.PLC Protocol_html_2d566cb5ffb2618c.png"]] 990 + 991 +**PLC Settings(GX Works2)** 992 + 993 +* Click [Ethernet/CC IE/MELSECNET]; 994 +* Please select [Ethernet] as network type; 995 +* Set station I/O number according to situation (For example, 0000 means that the module is connected to PLC CPU in first order); 996 +* Select [Online] as Mode; 997 +* Click [Operation setting] to set IP; 998 +* Select [Binary Code] as [Communication Data Code]; 999 +* Set protocol: TCP; 1000 +* Set [unpassive] in [Open system]; 1001 +* Set [receive] in [Fixed buffer]; 1002 +* Set [procedure Exist] in [Fixed buffer communication]; 1003 +* Disable [Pairing open]; 1004 +* Set [No confirm] in [Existence confirmation]; 1005 +* Host station port number: 1025; 1006 +* Save settings; 1007 +* Download project into PLC and restart it 1008 + 1009 +**Cable Wiring** 1010 + 1011 +[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_2297240b57346b2a.png?width=401&height=170&rev=1.1||alt="12.PLC Protocol_html_2297240b57346b2a.png"]] 1012 + 1013 + 1014 += **台达 PLC** = 1015 + 1016 +== **DVP 以太网协议** == 1017 + 1018 +[[下载链接>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Delta%20DVP%20Ethernet.zip]] 1019 + 1020 +== **DVP 串行协议** == 1021 + 1022 +[[下载链接>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Delta%20DVP%20Ethernet.zip]] 1023 + 1024 += **欧姆龙可编程逻辑控制器** = 1025 + 1026 +== **CP1 系列协议** == 1027 + 1028 +[[下载链接>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communication%20with%20ORMON%20CP1%20Series.zip]] 1029 + 1030 +== **CJ2M 系列协议** == 1031 + 1032 +[[下载链接>>https://ftp.we-con.com.cn/Download/WIKI/V-BOX/Demo/%E9%80%9A%E8%AE%AF%E6%A1%88%E4%BE%8B/Communication%20with%20ORMON%20CJ2M.zip]] 1033 + 885 885 = **Modbus RTU** = 886 886 887 -== **V-BOX as master** ==1036 +== **V-BOX 作为主** == 888 888 889 - Selectthe protocol“(%class="mark" %)Modbus RTU Slave(All Fuction)”,1038 +选择协议“(% _istranslated="1" class="mark" %)Modbus RTU Slave(All Fuction)”, 890 890 891 -(% class="mark" %) then set BaudRate,Port,Stop Bit,Data Bit,Parity1040 +(% class="mark" %)然后设置波特率,端口,停止位,数据位,奇偶校验 892 892 893 893 (% style="text-align:center" %) 894 894 [[image:1624342015914-382.png||height="486" width="800" class="img-thumbnail"]] 895 895 896 -== **V-BOX as slave** ==1045 +== **V-BOX 作为从站** == 897 897 898 - Selectthe protocol“(%class="mark" %)**Modbus RTU Master”**,1047 +选择协议“(% _istranslated="1" class="mark" %)**Modbus RTU Master”**, 899 899 900 -(% class="mark" %) then set BaudRate,Port,Stop Bit,Data Bit,Parity1049 +(% class="mark" %)然后设置波特率,端口,停止位,数据位,奇偶校验 901 901 902 902 (% style="text-align:center" %) 903 903 [[image:1624348709622-711.png||queryString="width=809&height=493" height="488" width="800" class="img-thumbnail"]] 904 904 905 -** Address List**1054 +**地址列表** 906 906 907 907 (% class="table-bordered" %) 908 -|** Type**|**Register**|**Function code & Description**909 -|(% rowspan="11" %) Word|(% rowspan="3" %)3|04(read input register: read current binary value in one or more input registers)1057 +|**类型**|**注册**|**函数代码和描述** 1058 +|(% rowspan="11" %)词|(% rowspan="3" %)3|04(读取输入寄存器:读取一个或多个输入寄存器中的当前二进制值) 910 910 |06 (write single register: write a binary value to a holding register) 911 911 |10 (write values to multiple addresses ) 912 912 |(% rowspan="3" %)4|03 (read holding register: read current binary value in one or more holding registers)
- image-20220825142437-1.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +126.5 KB - Content
- image-20220825142659-1.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Ben - Size
-
... ... @@ -1,0 +1,1 @@ 1 +124.2 KB - Content