Changes for page 1 Communication

Last modified by Hunter on 2024/07/01 10:54

From version 112.1
edited by Ben
on 2022/08/25 13:36
Change comment: There is no comment for this version
To version 108.1
edited by Ben
on 2022/08/25 10:56
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -216,7 +216,7 @@
216 216  
217 217  [[image:image-20220824110724-1.png]]
218 218  
219 -== **Micro850_FreeTag** ==
219 +== **CompactLogix Protocol** ==
220 220  
221 221  (((
222 222  (((
... ... @@ -790,7 +790,7 @@
790 790  
791 791  Mitsubishi FX5U series PLC
792 792  
793 -**1)V-BOX Settings**
793 +**HMI Settings**
794 794  
795 795  |**Items**|**Settings**|**Note**
796 796  |Protocol|Mitsubishi FX5U|
... ... @@ -798,7 +798,7 @@
798 798  |Port No.|5002|Must be the same as the PLC setting
799 799  |PLC station No.|0|
800 800  
801 -**2)Address List**
801 +**Address List**
802 802  
803 803  |**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note**
804 804  |(% rowspan="15" %)Bit|X|X|X o|0~~303237|
... ... @@ -826,11 +826,12 @@
826 826  |D|D|D d|0~~7999|
827 827  |SD|SD|SD d|0~~11999|
828 828  
829 -**3)PLC Settings (GX Works 3)**
829 +**PLC Settings (GX Works 3)**
830 830  
831 831  Find the [Ethernet port] in the navigation area.
832 832  
833 -[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_8e8f85ace087346c.png?width=300&height=593&rev=1.1||alt="12.PLC Protocol_html_8e8f85ace087346c.png" height="593" width="300"]]
833 +(% style="text-align:center" %)
834 +[[image:12.PLC Protocol_html_8e8f85ace087346c.png||data-xwiki-image-style-alignment="center" height="593" width="300" class="img-thumbnail"]]
834 834  
835 835  Select [Own Node Settings] in the [Setting Item List];
836 836  
... ... @@ -838,7 +838,8 @@
838 838  
839 839  Click [Detailed Settings] into [Ethernet Configuration (Built-in Ethernet Port)] windows;
840 840  
841 -[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_5d98495052c8c10e.png?width=600&height=339&rev=1.1||alt="12.PLC Protocol_html_5d98495052c8c10e.png" height="339" width="600"]]
842 +(% style="text-align:center" %)
843 +[[image:12.PLC Protocol_html_5d98495052c8c10e.png||data-xwiki-image-style-alignment="center" height="339" width="600" class="img-thumbnail"]]
842 842  
843 843  Select [SLMP Connection Module] and add into host station as below picture shows;
844 844  
... ... @@ -846,22 +846,21 @@
846 846  
847 847  Click [Close with Reflecting the Setting] to save and close window;
848 848  
849 -[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_14b489fdc6c6589d.png?width=600&height=350&rev=1.1||alt="12.PLC Protocol_html_14b489fdc6c6589d.png" height="350" width="600"]]
851 +(% style="text-align:center" %)
852 +[[image:12.PLC Protocol_html_14b489fdc6c6589d.png||data-xwiki-image-style-alignment="center" height="350" width="600" class="img-thumbnail"]]
850 850  
851 851  Click [Apply] to completed Etherenet settings;
852 852  
853 853  Switch to the [On line data operation] interface as below, check the item and click [Execute] to download.
854 854  
855 -[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_c93025a968a8a9e7.png?width=600&height=434&rev=1.1||alt="12.PLC Protocol_html_c93025a968a8a9e7.png" height="434" width="600"]]
858 +(% style="text-align:center" %)
859 +[[image:12.PLC Protocol_html_c93025a968a8a9e7.png||data-xwiki-image-style-alignment="center" height="434" width="600" class="img-thumbnail"]]
856 856  
857 -**4)Configure the communication protocol**
861 +**Cable Wiring**
858 858  
859 -[[image:image-20220825112403-1.png]]
863 +(% style="text-align:center" %)
864 +[[image:12.PLC Protocol_html_2297240b57346b2a.png||data-xwiki-image-style-alignment="center" height="170" width="401" class="img-thumbnail"]]
860 860  
861 -**5)Cable Wiring**
862 -
863 -[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_2297240b57346b2a.png?width=401&height=170&rev=1.1||alt="12.PLC Protocol_html_2297240b57346b2a.png" height="170" width="401"]]
864 -
865 865  = **Delta PLC** =
866 866  
867 867  == **DVP Ethernet Protocol** ==
image-20220825112403-1.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Ben
Size
... ... @@ -1,1 +1,0 @@
1 -128.1 KB
Content