... ... @@ -966,11 +966,11 @@
966 966  
967 967  [[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_2297240b57346b2a.png?width=401&height=170&rev=1.1||_mstalt="40720498" alt="12.可编程逻辑控制器Protocol_html_2297240b57346b2a.png" height="170" width="401"]]
968 968  
969 -== **L02 Ethernet Protocol** ==
969 +== **L02 MELSEC Ethernet** ==
970 970  
971 971  Mitsubishi L series CPU built-in Ethernet port.
972 972  
973 -**1)V-BOX Settings**
973 +**V-BOX Settings**
974 974  
975 975  |**Items**|**Settings**|**Note**
976 976  |Protocol|MIT L02 CPU MELSEC|
... ... @@ -978,7 +978,7 @@
978 978  |Port No.|1025|Must be the same as the PLC setting
979 979  |PLC station No.|0|Must be the same as the PLC setting
980 980  
981 -**2)Address List**
981 +**Address List**
982 982  
983 983  |**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note**
984 984  |Bit|X|X|X h|0~~FFFF|
... ... @@ -1011,12 +1011,17 @@
1011 1011  |Word|ZR|ZR|ZR h|0~~FFFF|
1012 1012  |Word|D|D|D d|0~~99999|
1013 1013  
1014 -**3)Configure the communication protocol**
1014 +**Communication Settings**
1015 1015  
1016 -[[image:image-20220825142659-1.png]]
1016 +Enable HMI Ethernet in [Project Settings];
1017 1017  
1018 -**4)PLC Settings (GX Works2 )**
1019 1019  
1019 +Set PLC IP in [Device IP] settings;
1020 +
1021 +[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_38189fae42f6caa7.png?width=600&height=206&rev=1.1||alt="12.PLC Protocol_html_38189fae42f6caa7.png" height="206" width="600"]]
1022 +
1023 +**PLC Settings (GX Works2 )**
1024 +
1020 1020  Create a project
1021 1021  
1022 1022  Set PLC IP, subnet mask and gateway;
... ... @@ -1035,7 +1035,7 @@
1035 1035  
1036 1036  Restart PLC device;
1037 1037  
1038 -**5)Cable Wiring**
1043 +**Cable Wiring**
1039 1039  
1040 1040  [[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_2297240b57346b2a.png?width=401&height=170&rev=1.1||alt="12.PLC Protocol_html_2297240b57346b2a.png" height="170" width="401"]]
1041 1041  