... ... @@ -907,12 +907,8 @@
907 907  |Word|ZR|ZR|ZR h|0~~FFFF|
908 908  |Word|D|D|D d|0~~99999|
909 909  
910 -**3)Configure the communication protocol**
910 +**3)PLC Settings (GX Works2 )**
911 911  
912 -[[image:image-20220825142659-1.png]]
913 -
914 -**4)PLC Settings (GX Works2 )**
915 -
916 916  Create a project
917 917  
918 918  Set PLC IP, subnet mask and gateway;
... ... @@ -931,6 +931,10 @@
931 931  
932 932  Restart PLC device;
933 933  
930 +**4)Configure the communication protocol**
931 +
932 +[[image:image-20220825142659-1.png]]
933 +
934 934  **5)Cable Wiring**
935 935  
936 936  [[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_2297240b57346b2a.png?width=401&height=170&rev=1.1||alt="12.PLC Protocol_html_2297240b57346b2a.png" height="170" width="401"]]
... ... @@ -939,7 +939,7 @@
939 939  
940 940  Mitsubishi QJ71E71 Ethernet communication module;
941 941  
942 -**V-BOX Settings**
942 +**1)V-BOX Settings**
943 943  
944 944  |**Items**|**Settings**|**Note**
945 945  |Protocol|MIT QJ71E71 MELSEC|
... ... @@ -947,7 +947,7 @@
947 947  |Port No.|1025|Must be the same as the PLC setting
948 948  |PLC station No.|0|Must be the same as the PLC setting
949 949  
950 -**Address List**
950 +**2)Address List**
951 951  
952 952  |**Type**|**Device registers**|**HMI registers**|**Format**|**Range**|**Note**
953 953  |(% rowspan="18" %)Bit|X|X|X h|0~~1FFF|
... ... @@ -979,17 +979,8 @@
979 979  |Z|Z|Z d|0~~15|
980 980  |ZR|ZR|ZR h|0~~FE7FF|
981 981  
982 -**HMI Communication Settings**
982 +**3)PLC Settings(GX Works2)**
983 983  
984 -1) Enable HMI Ethernet in [Project Settings];
985 -
986 -
987 -2) Set PLC IP in [Device IP] settings;
988 -
989 -[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_2d566cb5ffb2618c.png?width=554&height=190&rev=1.1||alt="12.PLC Protocol_html_2d566cb5ffb2618c.png"]]
990 -
991 -**PLC Settings(GX Works2)**
992 -
993 993  * Click [Ethernet/CC IE/MELSECNET];
994 994  * Please select [Ethernet] as network type;
995 995  * Set station I/O number according to situation (For example, 0000 means that the module is connected to PLC CPU in first order);
... ... @@ -1006,11 +1006,14 @@
1006 1006  * Save settings;
1007 1007  * Download project into PLC and restart it
1008 1008  
1009 -**Cable Wiring**
1000 +**4)Configure the communication protocol**
1010 1010  
1011 -[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_2297240b57346b2a.png?width=401&height=170&rev=1.1||alt="12.PLC Protocol_html_2297240b57346b2a.png"]]
1002 +[[image:image-20220825143728-1.png]]
1012 1012  
1004 +**5)Cable Wiring**
1013 1013  
1006 +[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_2297240b57346b2a.png?width=401&height=170&rev=1.1||alt="12.PLC Protocol_html_2297240b57346b2a.png"]]
1007 +
1014 1014  = **台达 PLC** =
1015 1015  
1016 1016  == **DVP 以太网协议** ==
image-20220825143728-1.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Ben
Size
... ... @@ -1,0 +1,1 @@
1 +124.7 KB
Content